SourceMed · Shelf #7313 in the ask interface
Barbed vs conventional sutures: closure 4–16 minutes faster and cheaper in arthroplasty and spine syntheses, complications split by layer — full-layer barbed closure raised complications to 19.7%
Shelf #7313 · Emergency & first hours
SPLIT — closure time and cost consistently favour barbed suture in every synthesis and primary RCT carded, and pooled wound complications do not differ, but primary RCTs split on complications by layer: full-layer barbed closure raised incision complications to 19.7% in a 582-patient three-arm trial while capsule-only barbed closure (7.2%) matched traditional closure, and one TKA RCT found fewer complications with barbed suture (2 vs 11)
Stamped: 2026-11-28.
Evidence published: 2014–2024.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In adults having wound closure with sutures — total knee and hip arthroplasty, spine surgery and other fields as tested — do knotless barbed sutures shorten closure and operating time versus conventional sutures, and do they differ in wound complications, dehiscence and cost?
Balance of the evidence
SPLIT. The time benefit is consistent everywhere it was randomised: the TKA synthesis (6 RCTs, 826 knees) found closure 4.41 minutes faster with barbed suture, the hip/knee synthesis (4 level-I trials, 588 patients) found 6.3 minutes faster, and the spine synthesis (7 studies, 8,645 patients) found closure 16.36 minutes and operating time 20.13 minutes shorter. Cost follows time in most reports (synthesis cost difference −282.61 in the units reported; $298 per case in the hip/knee synthesis; $324 vs $419 in the largest TKA RCT). Wound complications are where the record splits: the syntheses find no significant difference, and two TKA RCTs found fewer complications with barbed suture, but a 582-patient three-arm TKA RCT found full-layer barbed closure RAISED incision complications to 19.7% versus 7.2% for capsule-only barbed and 9.3% for traditional capsule closure, and an early TJA RCT reported more frequent and severe wound complications with barbed suture. The defensible reading is layer-specific: barbed suture for the capsule/deep layer saves time without a complication penalty in the randomised record; full-layer (including skin) barbed closure is the limb with a harm signal. Stop-condition check: at least three primary RCTs from inside the syntheses are carded per field for arthroplasty (Gililland 2014, Chan 2017, Sah 2015, Feng 2020) and one primary spine RCT from inside the spine synthesis (Shi 2022) — the spine primary base is one RCT, stated on the face. The retracted TKA synthesis PMID 37519132 is NOT carded, per the row fence. Tested products are named where the publication gives them (Stratafix in Chan 2017); where the record names no brand, the card says so.
MeSH: Arthroplasty, Replacement, Knee/instrumentation,methods · Equipment Design · Humans · Randomized Controlled Trials as Topic · Sutures · Arthroplasty, Replacement, Hip/adverse effects,methods · Arthroplasty, Replacement, Knee/adverse effects,methods · Female · Male · Postoperative Complications · Suture Techniques/instrumentation · Treatment Outcome · Length of Stay · Operative Time · Postoperative Complications/epidemiology · Spine/surgery · Surgical Wound Infection/epidemiology · Suture Techniques · Wound Healing/physiology · Costs and Cost Analysis · Single-Blind Method · Cost-Benefit Analysis · Knee Joint/surgery · Osteoarthritis, Knee/surgery · Range of Motion, Articular · Suture Techniques/economics · Blood Loss, Surgical · California · Disability Evaluation · Health Care Costs · Joint Capsule/surgery · Surgical Wound/complications · Suture Techniques/adverse effects · Prospective Studies
Cards (9)
Card 1 — TKA synthesis (Li 2020): barbed vs traditional suture in primary total knee arthroplasty — closure 4.41 minutes faster and cheaper, no significant rise in complications across 6 RCTs (826 knees)
Study: Systematic review and meta-analysis of RCTs (barbed vs traditional suture, primary TKA)
Population: Systematic review and meta-analysis of randomised controlled trials of barbed versus conventional suture for incision closure after primary total knee arthroplasty; 6 RCTs totalling 826 knees were included.
Summary: TKA synthesis (Li 2020): barbed vs traditional suture in primary total knee arthroplasty — closure 4.41 minutes faster and cheaper, no significant rise in complications across 6 RCTs (826 knees)
Result: Barbed suture shortened wound closure time (mean difference −4.41 minutes, 95% CI −5.11 to −3.72; P<.00001), reduced total wound-closure cost (mean difference −282.61, 95% CI −445.36 to −119.85; P=.0007, currency as reported in the source trials) and reduced needle-stick injury (risk ratio 0.14, 95% CI 0.03 to 0.78; P=.02). Complications did not differ significantly (risk ratio 0.80; P=.38) and neither did suture breakage (risk ratio 4.58, 95% CI 0.16 to 128.29; P=.37), range of motion at 6 weeks and 3 months, or Knee Society Score at 6 weeks. The authors concluded barbed suture is fast, low-cost, safe and effective in TKA while calling for more literature and longer follow-up.
Watch out: A synthesis card: its numbers pool the primary RCTs carded separately below and must not be counted as independent of them. The complication confidence interval printed in the record is internally inconsistent with its P value, so this card reports the risk ratio and P value as printed and claims no more.
Source: Li P et al. Barbed suture versus traditional suture in primary total knee arthroplasty: A systematic review and meta-analysis of randomized controlled studies. Medicine. 2020. PMID: 32481258. Registry ID: none in the record. MeSH: Arthroplasty, Replacement, Knee/instrumentation,methods · Equipment Design · Humans · Randomized Controlled Trials as Topic · Sutures
Card 2 — Hip and knee synthesis (Borzio 2016): 4 level-I trials, 588 patients — barbed closure 6.3 minutes faster, $298 saved per case, minor and major complication odds not significantly different
Study: Meta-analysis of level-I trials (barbed vs conventional suture, total hip and knee arthroplasty)
Population: Meta-analysis of all level-I trials of bidirectional barbed suture in total joint arthroplasty: 4 studies, 588 randomised patients — barbed closure 290 joint replacements (268 knees, 22 hips) versus conventional closure 298 (279 knees, 19 hips).
Summary: Hip and knee synthesis (Borzio 2016): 4 level-I trials, 588 patients — barbed closure 6.3 minutes faster, $298 saved per case, minor and major complication odds not significantly different
Result: Wound closure with barbed suture was 6.3 minutes faster than conventional closure (P<0.05). Odds of a minor complication were nearly identical (odds ratio 1.04, P=0.95) and odds of a major complication were not significantly different (odds ratio 2.94, P=0.27). Mean overall saving, counting the higher suture price, was USD 298 per case across hip and knee arthroplasty.
Watch out: Only 4 trials and only 41 hips in total: this synthesis is really a knee-arthroplasty synthesis with a small hip limb, and the major-complication odds ratio of 2.94, though non-significant, is imprecise and points the wrong way — the primary hip RCTs are carded on the companion hip records, not here.
Source: Borzio RW et al. Barbed sutures in total hip and knee arthroplasty: what is the evidence? A meta-analysis. International orthopaedics. 2016. PMID: 26572888. Registry ID: none in the record. MeSH: Arthroplasty, Replacement, Hip/adverse effects,methods · Arthroplasty, Replacement, Knee/adverse effects,methods · Female · Humans · Male · Postoperative Complications · Suture Techniques/instrumentation · Sutures · Treatment Outcome
Card 3 — Spine synthesis (Sarhan 2024): barbed vs conventional closure in spine surgery — operating time 20.13 minutes and closure time 16.36 minutes shorter; complications, infection, stay and reintervention not significantly different (7 studies, 8,645 patients)
Study: Systematic review and meta-analysis (barbed vs conventional suture, spine surgery)
Population: Systematic review and meta-analysis of barbed versus conventional sutures for wound closure in spine surgery: 7 eligible studies totalling 8,645 patients (search to 5 May 2024).
Summary: Spine synthesis (Sarhan 2024): barbed vs conventional closure in spine surgery — operating time 20.13 minutes and closure time 16.36 minutes shorter; complications, infection, stay and reintervention not significantly different (7 studies, 8,645 patients)
Result: Barbed sutures gave shorter operative time (mean difference −20.13 minutes, 95% CI −28.47 to −11.78; P<0.001) and shorter wound closure time (mean difference −16.36 minutes, 95% CI −20.9 to −11.82; P<0.001). Overall postoperative wound complications (risk ratio 0.83, 95% CI 0.60 to 1.14; P=0.25), postoperative infection (risk ratio 0.59, 95% CI 0.33 to 1.06; P=0.08), length of stay (mean difference −0.26 days, 95% CI −0.75 to 0.22; P=0.28) and reintervention (risk ratio 0.99, 95% CI 0.48 to 2.05; P=0.98) did not differ significantly. The authors called for high-quality RCTs with long-term follow-up and cost-effectiveness assessment.
Watch out: The 7 included studies are NOT all randomised — the record does not restrict eligibility to RCTs, and the large patient total is carried by non-randomised series. The only primary spine RCT carded on this shelf is Shi 2022 below; do not read the pooled time saving as RCT-grade for spine.
Source: Sarhan K et al. Barbed sutures versus conventional sutures for wound closure in spine surgeries: a systematic review and meta-analysis. Neurosurgical review. 2024. PMID: 39384652. Registry ID: none in the record. MeSH: Humans · Length of Stay · Operative Time · Postoperative Complications/epidemiology · Spine/surgery · Surgical Wound Infection/epidemiology · Suture Techniques · Sutures · Wound Healing/physiology
Card 4 — Primary TKA RCT (Gililland 2014): barbed running vs knotted interrupted closure in 411 randomised patients — closure 9.8 vs 14.5 minutes, total closure cost $324 vs $419, early complications similar
Study: Primary multicentre RCT (barbed running vs knotted interrupted closure, primary TKA) — inside the syntheses above
Population: Multicentre prospective randomised trial: 411 patients undergoing primary total knee arthroplasty randomised to barbed running closure (n=191) or knotted interrupted suture closure (n=203) as analysed. This trial sits inside the TKA syntheses carded above. The record names no barbed product brand.
Summary: Primary TKA RCT (Gililland 2014): barbed running vs knotted interrupted closure in 411 randomised patients — closure 9.8 vs 14.5 minutes, total closure cost $324 vs $419, early complications similar
Result: Closure time was shorter with barbed suture (9.8 vs 14.5 minutes; P<0.001) and total closure cost was lower ($324 vs $419; P<0.001), counting suture and operating-room time costs. Early complications and outcomes were similar between groups.
Watch out: Early complications only: a 411-patient trial cannot exclude differences in uncommon events such as deep infection, and no product brand is named in the record, so the result cannot be tied to one manufacturer's barbed suture.
Source: Gililland JM et al. Barbed versus standard sutures for closure in total knee arthroplasty: a multicenter prospective randomized trial. The Journal of arthroplasty. 2014. PMID: 24973931. Registry ID: none in the record. MeSH: Arthroplasty, Replacement, Knee/economics,methods · Costs and Cost Analysis · Equipment Design · Female · Humans · Male · Middle Aged · Operative Time · Prospective Studies · Single-Blind Method · Suture Techniques/economics · Treatment Outcome
Card 5 — Primary TKA RCT (Chan 2017): bidirectional barbed Stratafix vs Vicryl in 109 knees — arthrotomy closure 325 vs 491 seconds, fewer leak tests (2 vs 10) and fewer wound complications (2 vs 11), saving USD 48.7 per case locally
Study: Primary RCT (bidirectional barbed Stratafix vs Vicryl, primary TKA) — inside the syntheses above; tested product named
Population: Randomised controlled trial of 109 knees in primary total knee arthroplasty: bidirectional barbed suture (Stratafix, Ethicon Inc) versus traditional synthetic absorbable suture (Vicryl, Ethicon Inc) for arthrotomy and subcutaneous closure; follow-up to 3 months. This trial sits inside the TKA syntheses carded above.
Summary: Primary TKA RCT (Chan 2017): bidirectional barbed Stratafix vs Vicryl in 109 knees — arthrotomy closure 325 vs 491 seconds, fewer leak tests (2 vs 10) and fewer wound complications (2 vs 11), saving USD 48.7 per case locally
Result: Closure was significantly faster with barbed suture (arthrotomy 325 vs 491 seconds; subcutaneous 306 vs 381 seconds; P<.05). The traditional group had significantly more positive leak tests (10 vs 2; P<.05) and more wound complications (11 vs 2; P<.05). Range of motion and Knee Society Score did not differ. Counting suture material and operating-time cost, barbed suture saved on average USD 48.7 per TKA at the authors' institute.
Watch out: Single-centre and small (109 knees): the complication advantage (2 vs 11) rests on few events, and the cost saving is an institute-specific figure that depends on local operating-room time pricing.
Source: Chan VWK et al. Does Barbed Suture Lower Cost and Improve Outcome in Total Knee Arthroplasty? A Randomized Controlled Trial. The Journal of arthroplasty. 2017. PMID: 28089469. Registry ID: none in the record. MeSH: Adult · Aged · Arthroplasty, Replacement, Knee/economics,methods · Cost-Benefit Analysis · Female · Humans · Knee Joint/surgery · Male · Middle Aged · Operative Time · Osteoarthritis, Knee/surgery · Range of Motion, Articular · Suture Techniques/economics · Sutures · Treatment Outcome · Wound Healing
Card 6 — Primary bilateral TKA RCT (Sah 2015): within-patient randomised comparison in 50 patients — barbed closure 11.4 vs 16.1 minutes and $175 cheaper per case, no difference in scores, range of motion or wound appearance at 1 year
Study: Primary within-patient RCT (bidirectional barbed vs standard suture, simultaneous bilateral TKA) — inside the syntheses above
Population: Prospective randomised within-patient controlled trial: 50 consecutive patients having simultaneous bilateral total knee arthroplasties under one anaesthetic, one knee closed with running knotless bidirectional barbed suture and the other with standard interrupted and running sutures, randomly assigned by side; follow-up to 1 year. This trial sits inside the TKA syntheses carded above. The record names no barbed product brand.
Summary: Primary bilateral TKA RCT (Sah 2015): within-patient randomised comparison in 50 patients — barbed closure 11.4 vs 16.1 minutes and $175 cheaper per case, no difference in scores, range of motion or wound appearance at 1 year
Result: Mean wound closure time was 4.7 minutes less with barbed suture (11.4 ± 2.2 vs 16.1 ± 2.2 minutes; P<0.001); overall tourniquet time did not differ. There were no needle disengagements or suture breakages with barbed closure, versus 5 premature needle disengagements and 3 breakages with standard closure (P<0.005). No wound dehiscence or arthrotomy disruption occurred with either technique. One-year range of motion (126.7° vs 125.6°) and Knee Society knee scores (92.8 vs 93.3) did not differ. Counting material against time saved, barbed closure saved a mean USD 175 per case.
Watch out: Fifty patients, however elegant the within-patient design: as the author states, larger numbers are needed to compare uncommon complications, and none were observed in this small series — absence here is not proof of safety.
Source: Sah AP et al. Is There an Advantage to Knotless Barbed Suture in TKA Wound Closure? A Randomized Trial in Simultaneous Bilateral TKAs. Clinical orthopaedics and related research. 2015. PMID: 25631171. Registry ID: none in the record. MeSH: Aged · Arthroplasty, Replacement, Knee/adverse effects,economics,instrumentation · Biomechanical Phenomena · Blood Loss, Surgical · California · Cost-Benefit Analysis · Disability Evaluation · Equipment Design · Female · Health Care Costs · Humans · Knee Joint/physiopathology,surgery · Male · Middle Aged · Operative Time · Postoperative Complications/etiology · Prospective Studies · Range of Motion, Articular · Recovery of Function · Suture Techniques/adverse effects,economics,instrumentation · Sutures/economics · Time Factors · Treatment Outcome
Card 7 — Primary TKA RCT (Feng 2020): the layer matters — full-layer barbed closure RAISED incision complications to 19.7%, while capsule-only barbed closure (7.2%) matched traditional capsule closure (9.3%); both barbed strategies were faster (582 patients, three arms)
Study: Primary three-arm RCT (full-layer barbed vs capsule-only barbed vs traditional capsule closure, TKA)
Population: Single-centre randomised controlled trial, December 2017 to April 2019: 582 patients having total knee arthroplasty assigned to full-layer barbed suture (group A, n=193), barbed suture for the joint capsule only (group B, n=195), or traditional absorbable suture for the joint capsule (group C, n=194); primary endpoint incision complications within 3 months.
Summary: Primary TKA RCT (Feng 2020): the layer matters — full-layer barbed closure RAISED incision complications to 19.7%, while capsule-only barbed closure (7.2%) matched traditional capsule closure (9.3%); both barbed strategies were faster (582 patients, three arms)
Result: Incision complications were significantly higher with full-layer barbed closure: 19.7% in group A versus 7.2% in group B and 9.3% in group C (P<0.0125); capsule-only barbed and traditional capsule closure did not differ. Closure time was shorter in both barbed groups (13.5 ± 2.0 minutes in A and 16.1 ± 1.9 minutes in B) than with traditional closure (25.0 ± 2.0 minutes; P<0.001). The authors concluded full-thickness bidirectional barbed closure is not recommended, while capsule barbed closure is effective and time-saving.
Watch out: This is the shelf's principal harm signal and it is layer-specific: it condemns barbed suture carried through every layer including skin, not capsule closure. Single-centre; the record states registration at ClinicalTrials.gov with the ChiCTR number printed in the source line.
Source: Feng S et al. Are There Lower Complication Rates with Bidirectional Barbed Suture in Total Knee Arthroplasty Incision Closure? A Randomized Clinical Trial. Medical science monitor : international medical journal of experimental and clinical research. 2020. PMID: 32753571. Registry ID: ChiCTR-IPR-17013677. MeSH: Aged · Arthroplasty, Replacement, Knee/methods · Body Mass Index · Female · Follow-Up Studies · Humans · Incidence · Joint Capsule/surgery · Knee Joint/surgery · Male · Middle Aged · Operative Time · Postoperative Complications/epidemiology,etiology · Prospective Studies · Surgical Wound/complications · Suture Techniques/adverse effects · Sutures/adverse effects · Treatment Outcome
Card 8 — Primary spine RCT (Shi 2022): knotless barbed vs conventional closure in posterior long-segment lumbar surgery (181 patients) — operating-room and closure times shorter and wound complications (dehiscence and infection) fewer, with no difference in stay, readmission or cost
Study: Primary RCT (knotless barbed vs conventional closure, posterior long-segment lumbar surgery) — inside the spine synthesis above
Population: Prospective randomised controlled trial: 181 patients undergoing posterior long-segment lumbar surgery assigned to barbed suture wound closure (n=91) or conventional suture closure (n=90). This trial sits inside the spine synthesis carded above. The record names no barbed product brand.
Summary: Primary spine RCT (Shi 2022): knotless barbed vs conventional closure in posterior long-segment lumbar surgery (181 patients) — operating-room and closure times shorter and wound complications (dehiscence and infection) fewer, with no difference in stay, readmission or cost
Result: The barbed group had significantly lower operating-room time (P=0.036), wound closure time (P<0.001), average wound closure time (P<0.001) and wound complication rates for dehiscence and infection combined (P=0.031). Incision length (P=0.086), length of stay (P=0.174), 90-day readmission (P=0.232) and costs (P=0.205) did not differ significantly. The fetched record prints P values without the group time or complication numbers, and this card claims none.
Watch out: The spine field's only carded primary RCT: one trial of 181 patients in long-segment lumbar surgery cannot carry the whole spine question, and its abstract reports significance without the underlying numbers.
Source: Shi K et al. The use of novel knotless barbed sutures in posterior long-segment lumbar surgery: a randomized controlled trial. Journal of orthopaedic surgery and research. 2022. PMID: 35585558. Registry ID: none in the record. MeSH: Humans · Length of Stay · Prospective Studies · Suture Techniques · Sutures · Treatment Outcome
Card 9 — Synthesis: barbed suture reliably buys closure time in every randomised field tested, at no pooled complication cost for deep/capsular closure — but full-layer barbed closure raised complications in the largest three-arm TKA trial, so the answer is layer-specific, not blanket
Study: Synthesis
Population: All reports carded on this shelf: 3 syntheses (TKA 6 RCTs / 826 knees; hip+knee 4 level-I trials / 588 patients; spine 7 studies / 8,645 patients) and 5 primary RCTs (411, 109, 50 within-patient, 582 and 181 patients).
Summary: Synthesis: barbed suture reliably buys closure time in every randomised field tested, at no pooled complication cost for deep/capsular closure — but full-layer barbed closure raised complications in the largest three-arm TKA trial, so the answer is layer-specific, not blanket
Result: Closure time falls by roughly 4–6 minutes in arthroplasty syntheses and by about 16 minutes for closure (20 minutes operating time) in the spine synthesis, and cost falls with time in most reports. Pooled complications do not differ in any synthesis. Against that, Feng 2020 (n=582) found full-layer barbed closure caused significantly more incision complications (19.7%) than capsule-only barbed (7.2%) or traditional capsule closure (9.3%), while Chan 2017 found fewer complications with barbed closure (2 vs 11) — a genuine split at primary-trial level, resolved most plausibly by layer: capsule/deep barbed closure is the supported use. The retracted TKA synthesis PMID 37519132 was not carded, per the commissioning row's fence. No randomised evidence here addresses dehiscence as a stand-alone powered endpoint.
Watch out: Synthesis and primary cards overlap by design (the primaries sit inside the syntheses): never add their patient totals together as if independent.
Source: Synthesis of the reports carded above; no additional source.