SourceMed · Shelf #7386 in the ask interface

Carotid IMT reference intervals by method and population: UK 97.5th percentile 0.60 mm at 35-39 rising to 0.81 mm at 60+; Chinese IMT rises 5.5-5.8 micrometres/year

Shelf #7386 · Heart, vessels, blood pressure & clotting

PHYSIOLOGY — ESTABLISHED — carotid IMT reference intervals are established in four primary datasets across three ultrasound methods (echotracking percentiles in 4,234 healthy people; B-mode norms in Andean-Hispanic and UK populations; RF-ultrasound values in 3,053 Han Chinese adults), with age-, sex-, segment- and population-specific limits printed per dataset

Stamped: 2026-11-28.

Evidence published: 2008–2024.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In healthy adults, what is common carotid intima-media thickness — its mean, spread and age-, sex- and ethnicity-specific reference intervals / percentiles measured by B-mode ultrasound (manual, semiautomated and echotracking methods) — and how much do measurement method and population move the values that define 'increased' cIMT?

Balance of the evidence

Textbook framing: Boron & Boulpaep, vascular physiology / arterial wall mechanics — the framing is general, and this shelf rests chiefly on the primary normative imaging literature, and says so. Four primary datasets, carded PER METHOD and PER POPULATION as the measurement demands: echotracking in 24,871 pooled individuals (healthy sub-population 4,234) generating age- and sex-specific percentile equations; B-mode ultrasound in 1,448 Andean-Hispanic adults (healthy reference sample 472) with age- and sex-dependent 95th percentiles; semiautomated border detection in 137 strictly healthy UK adults, whose 97.5th-percentile common carotid limits rise from 0.60 mm at age 35-39 to 0.81 mm at age 60+ (bifurcation limits are higher, to 1.05 mm); and radiofrequency-signal ultrasound in 3,053 healthy Han Chinese adults, with IMT rising 5.5 micrometres/year in women and 5.8 in men. Near-wall vs far-wall and mean vs maximum IMT are different numbers, and ethnicity-specific intervals are content, not caveat. PHYSIOLOGY — ESTABLISHED.

MeSH: Carotid Intima-Media Thickness · Reference Values · Female · Humans · Male · Middle Aged · Adult · Aged · Risk Factors · Ultrasonography/methods · Vascular Stiffness/physiology · China · Peru

Cards (5)

Card 1 — Echotracking reference intervals (Engelen 2013): pooled 24,871 individuals from 24 centres; percentile equations built in 4,234 healthy people — risk factors shift a person's Z-score independently of age and sex

Study: Primary human physiology study (echotracking common carotid IMT reference intervals, pooled multicentre)

Population: Common carotid IMT data obtained by echotracking on 24,871 individuals (53% men; age range 15-101 years) from 24 research centres worldwide. Individuals without cardiovascular disease, cardiovascular risk factors or blood-pressure-, lipid- or glucose-lowering medication formed the healthy sub-population (n=4,234) used to establish sex-specific percentile equations across age; a broader no-CVD/no-treatment sub-population numbered 14,609.

Summary: Echotracking reference intervals (Engelen 2013): pooled 24,871 individuals from 24 centres; percentile equations built in 4,234 healthy people — risk factors shift a person's Z-score independently of age and sex

Result: Age- and sex-specific percentiles of common carotid IMT were estimated in the healthy population, allowing an observed value to be expressed as a Z-score against the value predicted for a person of the same age and sex. In the no-CVD/no-treatment sub-population, IMT Z-scores were independently associated with systolic blood pressure (standardised beta 0.19 in men, 0.18 in women), smoking (0.25 and 0.11), diabetes (0.19 and 0.19), total-to-HDL cholesterol ratio (0.07 and 0.05) and body mass index (0.14 and 0.07). The fetched record does not print the percentile values in millimetres, and this card claims none.

Watch out: Method-bound: echotracking values are the reference for that technique, not interchangeable with conventional B-mode measurements (cards below); the healthy percentile population (4,234) is a selected subset of the 24,871 pooled individuals.

Source: Engelen L et al. Reference intervals for common carotid intima-media thickness measured with echotracking: relation with risk factors. European heart journal. 2013. PMID: 23186808. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Aged, 80 and over · Atherosclerosis/diagnostic imaging · Carotid Intima-Media Thickness/statistics & numerical data · Female · Humans · Male · Middle Aged · Reference Values · Risk Factors · Young Adult

Card 2 — Prevencion Study (Pastorius 2010): normative cIMT in 1,448 Andean-Hispanic adults — 95th-percentile values in the 472-person healthy reference sample were age- and sex-dependent

Study: Primary human physiology study (population-based B-mode cIMT normative values, Andean-Hispanic)

Population: 1,448 adults enrolled in a population-based study in Peru (the Prevencion Study), with carotid IMT and plaque measured by high-resolution ultrasonography. A healthy reference sample (n=472) with no cardiovascular disease, normal weight and normal metabolic parameters was selected to establish normative values.

Summary: Prevencion Study (Pastorius 2010): normative cIMT in 1,448 Andean-Hispanic adults — 95th-percentile values in the 472-person healthy reference sample were age- and sex-dependent

Result: In the reference sample, 95th-percentile cIMT values were both age- and gender-dependent (the fetched record does not print the millimetre cut-offs, and this card claims none). In the whole population, predictors of increasing cIMT were older age, impaired fasting glucose, diabetes, higher systolic blood pressure, higher LDL cholesterol, smoking and male sex; predictors of carotid plaque were older age, male sex, higher systolic and lower diastolic pressure and higher LDL cholesterol. HDL cholesterol and C-reactive protein were not associated with cIMT or plaque.

Watch out: Ethnicity-specific by design: these are Andean-Hispanic reference values from Peru and should not be applied as universal limits; plaque and IMT are reported together in the source but are different measurements.

Source: Pastorius CA et al. Normative values and correlates of carotid artery intima-media thickness and carotid atherosclerosis in Andean-Hispanics: The Prevencion Study. Atherosclerosis. 2010. PMID: 20510418. Registry ID: none in the record. MeSH: Atherosclerosis · Blood Pressure · Cardiovascular Diseases/pathology · Carotid Arteries/pathology · Cholesterol, HDL/metabolism · Cholesterol, LDL/metabolism · Female · Humans · Male · Middle Aged · Peru · Reference Values · Regression Analysis · Risk · Tunica Intima/pathology · Tunica Media/pathology

Card 3 — UK semiautomated B-mode norms (Lim 2008): in 137 strictly healthy adults, 97.5th-percentile common carotid IMT rose from 0.60 mm (age 35-39) to 0.81 mm (age 60+); bifurcation limits were higher, to 1.05 mm

Study: Primary human physiology study (semiautomated B-mode carotid IMT normal values, UK)

Population: 453 asymptomatic men and women aged 35 to 75 years without clinical atherosclerosis underwent B-mode carotid duplex ultrasound (Sonos 7500, Philips) with mean far-wall IMT measured by semiautomated edge-detection software (Q-lab 4, Philips). The healthy population (n=137) had no cardiovascular disease, diabetes or hypertension, body mass index below 30 kg/m2, serum cholesterol below 6 mmol/L (approx. 232 mg/dL) and no carotid plaque.

Summary: UK semiautomated B-mode norms (Lim 2008): in 137 strictly healthy adults, 97.5th-percentile common carotid IMT rose from 0.60 mm (age 35-39) to 0.81 mm (age 60+); bifurcation limits were higher, to 1.05 mm

Result: IMT at the bifurcation was significantly higher than at the common carotid artery, and IMT at both sites increased significantly with age. The upper limits (97.5th percentile) of IMT at the common carotid artery for ages 35-39, 40-49, 50-59 and 60+ were 0.60, 0.64, 0.71 and 0.81 mm respectively, whereas at the bifurcation they were 0.83, 0.77, 0.85 and 1.05 mm respectively.

Watch out: The strictly healthy denominator is small (137 of 453 screened) and the measurement is mean far-wall IMT by one semiautomated system; bifurcation values must never be read against common-carotid limits, and vice versa.

Source: Lim TK et al. Normal value of carotid intima-media thickness--a surrogate marker of atherosclerosis: quantitative assessment by B-mode carotid ultrasound. Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography. 2008. PMID: 17764896. Registry ID: none in the record. MeSH: Adult · Aged · Analysis of Variance · Atherosclerosis/diagnostic imaging/physiopathology · Carotid Artery, Common/diagnostic imaging/pathology · Cohort Studies · Female · Humans · Male · Middle Aged · Observer Variation · Reference Values · Reproducibility of Results · Risk Assessment · Sensitivity and Specificity · Severity of Illness Index · Tunica Intima/diagnostic imaging/pathology · Ultrasonography, Doppler, Duplex/methods · United Kingdom

Card 4 — Nationwide Chinese RF-ultrasound references (Xing 2024): 3,053 healthy Han Chinese adults — carotid IMT rose 5.5 micrometres/year in women and 5.8 in men; women had thinner IMT but larger augmentation pressure and index

Study: Primary human physiology study (radiofrequency-ultrasound carotid IMT and stiffness reference values, nationwide Chinese)

Population: 3,053 healthy Han Chinese adults (1,922 women) aged 18-79 years enrolled at 28 tertiary centres across China (2021-2022); common carotid walls were tracked in real time by a radiofrequency-signal ultrasound system, which automatically reported IMT, diameter, compliance coefficient, beta stiffness, local pulse wave velocity, local systolic pressure, augmented pressure and augmentation index.

Summary: Nationwide Chinese RF-ultrasound references (Xing 2024): 3,053 healthy Han Chinese adults — carotid IMT rose 5.5 micrometres/year in women and 5.8 in men; women had thinner IMT but larger augmentation pressure and index

Result: All carotid parameters showed significantly age-related trajectories. Women had thinner IMT, smaller carotid diameter and larger augmented pressure and augmentation index than men; beta stiffness and local PWV were higher in men before the forties and higher in women after. The increase rate of carotid IMT was 5.5 micrometres/year in women and 5.8 micrometres/year in men, and diameter rose 0.03 mm/year in both sexes. Blood pressure, body mass index and triglyceride levels were the major clinical determinants after adjustment for age and sex. The fetched record does not print the age-band reference tables in millimetres, and this card claims none beyond the rates above.

Watch out: A single-population (Han Chinese), single-technology (RF-signal) reference set: its stiffness and wave-reflection values belong to this carotid-local method and are not carotid-femoral PWV values (a different shelf).

Source: Xing C et al. Reference values of carotid intima-media thickness and arterial stiffness in Chinese adults based on ultrasound radio frequency signal: A nationwide, multicenter study. Chinese medical journal. 2024. PMID: 38958034. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Female · Humans · Male · Middle Aged · Young Adult · Carotid Arteries/diagnostic imaging · Carotid Intima-Media Thickness · China · East Asian People · Pulse Wave Analysis · Reference Values · Ultrasonography/methods · Vascular Stiffness/physiology

Card 5 — Synthesis: carotid IMT reference values are established per method and per population — age and sex move them in every dataset, and the segment measured (common carotid vs bifurcation) changes the limit by up to about 0.24 mm

Study: Synthesis

Population: Synthesis of the four primary datasets carded above.

Summary: Synthesis: carotid IMT reference values are established per method and per population — age and sex move them in every dataset, and the segment measured (common carotid vs bifurcation) changes the limit by up to about 0.24 mm

Result: Framed by Boron & Boulpaep (vascular physiology / arterial wall mechanics; the framing is general, and this shelf rests chiefly on the primary normative imaging literature). Echotracking percentiles from 4,234 healthy people within a 24,871-person pool (Engelen 2013) express IMT as age- and sex-specific Z-scores; B-mode norms in 472 healthy Andean-Hispanics (Prevencion 2010) are age- and sex-dependent at the 95th percentile; semiautomated far-wall limits in 137 strictly healthy UK adults (Lim 2008) rise from 0.60 mm at 35-39 years to 0.81 mm at 60+ at the common carotid, with higher bifurcation limits (to 1.05 mm); and RF-ultrasound values in 3,053 healthy Han Chinese adults (Xing 2024) rise 5.5-5.8 micrometres/year. What counts as 'increased' cIMT is therefore a statement about method, segment, age, sex and population together — never a single universal cut-off.

Watch out: Never pool values across the three ultrasound methods or across segments; where a dataset's record does not print millimetre tables, this shelf claims none.

Source: Synthesis of the reports carded above; no additional source.