24-h ABPM normal values vs outcome thresholds: normotensive 95th percentiles 129/80 (24-h), 137/88 (day), 121/72 (night); IDACO hypertension thresholds 130/80, 140/85, 120/70

Shelf #7390 · Heart, vessels, blood pressure & clotting

PHYSIOLOGY — ESTABLISHED — normal 24-hour ambulatory values are established by population reference datasets (Belgian 95th percentiles 129/80 mmHg 24-hour, 137/88 daytime, 121/72 night-time; British means 115/72 awake and 97/58 asleep) and outcome-driven thresholds by IDACO (ambulatory hypertension 130/80, 140/85 and 120/70 mmHg), with the two kinds of number distinguished on the face and the row's third-dataset condition met by the verified Belgian dataset

Stamped: 2026-11-28.

Evidence published: 1979–2007.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In adults without hypertension, what are normal 24-hour ambulatory blood-pressure values — daytime, night-time and 24-hour means and upper reference limits (95th percentiles) — how large is the normal night-time dip, and how do statistically derived reference limits compare with outcome-driven ambulatory thresholds?

Balance of the evidence

Textbook framing: Guyton & Hall, long-term blood-pressure control chapters — the framing is brief, and this shelf rests chiefly on the primary population-monitoring literature, and says so. Two KINDS of number are carded and never presented as interchangeable: (1) statistical reference limits from normotensive population samples — the Belgian Population Study (1,057 people; normotensive 95th percentiles 129/80 mmHg over 24 hours, 137/88 daytime, 121/72 night-time) and a normal British sample (282 people; awake mean 115/72, asleep mean 97/58, with 2-standard-deviation upper limits of 136/86 awake and 121/73 asleep — a normal night-time dip of about 18/14 mmHg between the printed means); and (2) outcome-driven thresholds from IDACO (5,682 participants), whose rounded ambulatory-hypertension thresholds (130/80 for 24 hours, 140/85 daytime, 120/70 night-time) sit close to, but are derived differently from, the statistical limits. A companion subject-level analysis (5,018 untreated participants) found home/conventional thresholds did not need to differ by sex or age. The row's third-dataset stop condition is MET: alongside PAMELA and IDACO, the Belgian Population Study was verified from its fetched record as a third primary reference dataset (the British sample is a fourth). The PAMELA card is transparent that its fetched record is the study's design report and prints no values. PHYSIOLOGY — ESTABLISHED.

MeSH: Blood Pressure Monitoring, Ambulatory · Reference Values · Blood Pressure/physiology · Circadian Rhythm · Female · Humans · Male · Middle Aged · Adult · Aged · Hypertension/diagnosis/epidemiology · Risk Factors

Cards (6)

Card 1 — Belgian Population Study (Staessen 1996): 1,057 randomly sampled adults — in normotensive participants the 95th percentiles were 129/80 mmHg (24-hour), 137/88 (daytime) and 121/72 (night-time)

Study: Primary human physiology study (population-based 24-hour ABPM reference distributions, Belgian Population Study) — third primary reference dataset verified at build

Population: A random population sample of 1,057 persons aged 20-88 years in a geographically defined area of Belgium (328 hypertensive by conventional pressure above 140/90 mmHg or treatment; 729 normotensive), with 24-hour ambulatory pressure recorded at 20-minute intervals from 0800 to 2200 h and 45-minute intervals overnight, plus conventional pressures at home and (in 532) at a clinic.

Summary: Belgian Population Study (Staessen 1996): 1,057 randomly sampled adults — in normotensive participants the 95th percentiles were 129/80 mmHg (24-hour), 137/88 (daytime) and 121/72 (night-time)

Result: In the whole sample, 24-hour, daytime and night-time pressures averaged 119/71, 125/77 and 108/62 mmHg respectively. In the normotensive subgroup, the 95th percentiles of the 24-hour, daytime and night-time pressures were 129/80, 137/88 and 121/72 mmHg respectively; restricting to the 275 participants normotensive both at home and at the clinic barely moved them (127/79, 135/87 and 118/72 mmHg). Pooling with other large cohorts, the authors placed the likely normotension-to-hypertension transition at 130-135/80-85 (24-hour), 135-140/85-90 (daytime) and 120-125/70-75 mmHg (night-time), while noting these percentile-based definitions still needed outcome validation.

Watch out: Statistical (percentile) limits from a 1990s Belgian sample with its own day/night definitions: they describe a distribution, not a risk threshold — the outcome-driven numbers are the IDACO card below, and the two kinds must not be interchanged.

Source: Staessen JA et al. An epidemiological approach to ambulatory blood pressure monitoring:the Belgian Population Study. Blood pressure monitoring. 1996. PMID: 10226197. Registry ID: none in the record. MeSH: none in the record

Card 2 — Normal British sample (Manning 1998): 282 people without hypertension — awake mean 115/72 and asleep mean 97/58 mmHg; 2-standard-deviation upper limits 136/86 awake, 121/73 asleep, 131/82 overall

Study: Primary human physiology study (24-hour ABPM levels and upper limits in a normal British population sample)

Population: 282 Caucasian subjects with no known hypertension or cardiovascular disease, recruited from local light industry and a general practice population in Britain, with office and 24-hour ambulatory blood pressures measured.

Summary: Normal British sample (Manning 1998): 282 people without hypertension — awake mean 115/72 and asleep mean 97/58 mmHg; 2-standard-deviation upper limits 136/86 awake, 121/73 asleep, 131/82 overall

Result: Mean office pressure was 120/75 mmHg, ambulatory mean awake pressure 115/72 and mean asleep pressure 97/58 mmHg — the printed means imply a normal asleep dip of about 18 mmHg systolic and 14 mmHg diastolic below awake values. Men had slightly higher office and awake pressures, with no sex difference asleep. Age was the best predictor of variation but explained only a small amount of it. The two-standard-deviation upper limits for this population were 136/86 mmHg (awake), 121/73 (asleep) and 131/82 (overall).

Watch out: A convenience sample of 282 (light industry and one general practice), all Caucasian: supportive beside the larger population studies, and its upper limits are mean + 2 standard deviations — a different construction from the Belgian 95th percentiles.

Source: Manning G et al. Twenty-four hour ambulatory blood pressure: a sample from a normal British population. Journal of human hypertension. 1998. PMID: 9504353. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Blood Pressure · Blood Pressure Monitoring, Ambulatory · Female · Humans · Male · Middle Aged · Reference Values

Card 3 — PAMELA programme (Cesana 1991): the population-based reference programme as designed — 2,400 randomly selected Monza residents aged 25-64; the fetched record is the design report and prints no reference values

Study: Programme design report (PAMELA population ABPM reference programme) — design record only, no values printed in the fetched record

Population: The PAMELA Study as designed: 2,400 subjects aged 25-64 years randomly selected in the city of Monza, Italy, within sex and age strata by WHO-MONICA criteria, to undergo clinic pressure, random-zero pressure, 24-hour ambulatory monitoring (SpaceLabs 90207), home pressure, electrocardiographic and echocardiographic indices and risk-factor measurement.

Summary: PAMELA programme (Cesana 1991): the population-based reference programme as designed — 2,400 randomly selected Monza residents aged 25-64; the fetched record is the design report and prints no reference values

Result: The record carded here is the programme's design paper: it sets out the epidemiological approach — comparing 24-hour ambulatory values with clinic values in a random sample of a large population — and prints no ambulatory means, percentiles or limits, and this card claims none. It is carded, transparently labelled, because PAMELA is one of the two programmes named in the commissioning row; the numerical reference content of this shelf is carried by the Belgian, British and IDACO cards.

Watch out: Do not cite this card for any PAMELA number: none appears in its fetched record. Later PAMELA publications report values but were not the record verified for this shelf.

Source: Cesana G et al. Ambulatory blood pressure normalcy: the PAMELA Study. Journal of hypertension. Supplement : official journal of the International Society of Hypertension. 1991. PMID: 1797995. Registry ID: none in the record. MeSH: Adult · Blood Pressure/physiology · Blood Pressure Determination/methods · Blood Pressure Monitors · Circadian Rhythm/physiology · Female · Humans · Hypertension/diagnosis/epidemiology · Italy/epidemiology · Male · Middle Aged · Reference Values · Sampling Studies

Card 4 — IDACO outcome-driven thresholds (Kikuya 2007): 5,682 participants — rounded thresholds for ambulatory hypertension were 130/80 mmHg (24-hour), 140/85 (daytime) and 120/70 (night-time); optimal 115/75, 120/80 and 100/65

Study: Primary human physiology / outcomes study (outcome-driven ABPM diagnostic thresholds, IDACO consortium)

Population: 5,682 participants (mean age 59.0 years; 43.3% women) with 24-hour ambulatory monitoring in prospective population studies in Copenhagen (Denmark), Noorderkempen (Belgium), Ohasama (Japan) and Uppsala (Sweden), followed for a median 9.7 years, during which 814 cardiovascular endpoints occurred (377 strokes, 435 cardiac events).

Summary: IDACO outcome-driven thresholds (Kikuya 2007): 5,682 participants — rounded thresholds for ambulatory hypertension were 130/80 mmHg (24-hour), 140/85 (daytime) and 120/70 (night-time); optimal 115/75, 120/80 and 100/65

Result: Thresholds were derived to yield 10-year cardiovascular risks equivalent to office pressures of 120/80 (optimal), 130/85 (normal) and 140/90 mmHg (high). Unrounded systolic/diastolic thresholds for ambulatory hypertension were 131.0/79.4 mmHg (24-hour), 138.2/86.4 (daytime) and 119.5/70.8 (night-time). After rounding, optimal ambulatory pressure was 115/75 (24-hour), 120/80 (daytime) and 100/65 (night-time); normal was 125/75, 130/85 and 110/70; and ambulatory hypertension was 130/80, 140/85 and 120/70 mmHg respectively. The authors note these outcome-driven thresholds for optimal and normal pressure are lower than those proposed by then-current guidelines.

Watch out: These are risk-equivalence thresholds anchored to office-pressure risk levels — a different kind of number from the statistical percentile limits above, even where the values nearly coincide; the derivation cohorts were older (mean 59) population samples, not screened normotensive volunteers.

Source: Kikuya M et al. Diagnostic thresholds for ambulatory blood pressure monitoring based on 10-year cardiovascular risk. Circulation. 2007. PMID: 17420350. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Aged, 80 and over · Alcohol Drinking/epidemiology · Antihypertensive Agents/therapeutic use · Auscultation · Belgium/epidemiology · Blood Pressure Monitoring, Ambulatory/instrumentation/methods · Body Mass Index · Cardiovascular Diseases/epidemiology · Circadian Rhythm · Cohort Studies · Coronary Disease/epidemiology · Denmark/epidemiology · Diabetes Mellitus/epidemiology · Dyslipidemias/epidemiology · Female · Heart Failure/epidemiology/etiology · Humans · Hypertension/diagnosis/drug therapy/epidemiology/physiopathology · Japan/epidemiology · Male · Middle Aged · Myocardial Ischemia/mortality · Myocardial Revascularization/statistics & numerical data · Oscillometry · Predictive Value of Tests · Proportional Hazards Models · Prospective Studies · Reference Values · Reproducibility of Results · Risk Factors · Smoking/epidemiology · Sphygmomanometers/classification · Stroke/epidemiology · Sweden/epidemiology

Card 5 — Companion thresholds (Nomura 2014): subject-level meta-analysis of 5,018 untreated participants from 5 populations — home and conventional BP thresholds did not differ significantly by sex or by age (under 60 vs 60+)

Study: Supporting limb: subject-level meta-analysis of outcome-driven conventional and home BP thresholds by sex and age

Population: 5,018 people untreated for hypertension, randomly recruited from 5 populations (56.7% women; 42.3% aged 60 or over), followed for a median 8.3 years with 414 cardiovascular events; conventional and home blood-pressure thresholds were derived from each other by outcome equivalence, stratified by sex and age.

Summary: Companion thresholds (Nomura 2014): subject-level meta-analysis of 5,018 untreated participants from 5 populations — home and conventional BP thresholds did not differ significantly by sex or by age (under 60 vs 60+)

Result: Sex differences between derived thresholds were all nonsignificant (P at least 0.24), ranging from -4.6 to 3.6 mmHg systolic and -4.3 to 2.1 mmHg diastolic; age differences were likewise nonsignificant (P at least 0.08) except for home thresholds derived from conventional levels of 140 mmHg systolic and 80 mmHg diastolic. The authors conclude outcome-driven criteria support single blood-pressure thresholds applied in both sexes and across the age range.

Watch out: A companion-threshold study of conventional and HOME pressure, not a 24-hour ABPM reference dataset: it is carded as the supporting limb named in the row, for the sex/age question only, and contributes no ambulatory limits.

Source: Nomura K et al. Thresholds for conventional and home blood pressure by sex and age in 5018 participants from 5 populations. Hypertension (Dallas, Tex. : 1979). 2014. PMID: 24980664. Registry ID: none in the record. MeSH: Adult · Age Factors · Aged · Aged, 80 and over · Blood Pressure/physiology · Blood Pressure Monitoring, Ambulatory/methods · Cardiovascular Diseases/physiopathology · Diastole · Female · Humans · Hypertension/physiopathology · Male · Middle Aged · Population Surveillance/methods · Reference Values · Risk Assessment/methods/statistics & numerical data · Risk Factors · Sex Factors · Systole · Time Factors · Young Adult

Card 6 — Synthesis: normal ambulatory values and outcome thresholds nearly coincide but are different kinds of number — statistical 95th percentiles (129/80 over 24 hours) versus risk-derived hypertension thresholds (130/80 over 24 hours)

Study: Synthesis

Population: Synthesis of the reports carded above.

Summary: Synthesis: normal ambulatory values and outcome thresholds nearly coincide but are different kinds of number — statistical 95th percentiles (129/80 over 24 hours) versus risk-derived hypertension thresholds (130/80 over 24 hours)

Result: Framed by Guyton & Hall (long-term blood-pressure control; framing brief — this shelf rests chiefly on the primary population-monitoring literature). Statistical limb: the Belgian Population Study's normotensive 95th percentiles (129/80 mmHg 24-hour, 137/88 daytime, 121/72 night-time; n=1,057) and the British sample's means and +2SD limits (awake 115/72, asleep 97/58; n=282) describe what ambulatory pressures look like in people without hypertension, including a normal asleep dip of about 18/14 mmHg between the British printed means. Outcome limb: IDACO's risk-equivalent thresholds (n=5,682) round to 130/80 (24-hour), 140/85 (daytime) and 120/70 (night-time) for ambulatory hypertension, and the companion analysis (n=5,018) supports single thresholds across sex and age. The row's stop condition was discharged at build: a third primary reference dataset (Belgian Population Study, PMID 10226197) was verified from its fetched record, in addition to PAMELA (whose fetched record is its design report, carded as such) and IDACO. Orthostatic standing changes are a different measurement (a different shelf) and office-BP treatment shelves presuppose these limits rather than re-carding them.

Watch out: Never present a percentile limit and an outcome threshold as interchangeable, even when the rounded numbers match.

Source: Synthesis of the reports carded above; no additional source.