SourceMed · Shelf #7391 in the ask interface

Brachial-ankle PWV reference ranges: healthy mean 13.90 m/s; decade upper limits rise to 17.98 m/s (men) and 19.15 m/s (women) by the sixties — not a cfPWV scale

Shelf #7391 · Heart, vessels, blood pressure & clotting

PHYSIOLOGY — EMERGING — brachial-ankle PWV reference ranges are established in three large East-Asian datasets (21,094 Chinese subjects; 7,881 healthy Japanese subjects; 974 healthy Northern Chinese subjects with decade upper limits), graded down because all datasets are East-Asian and single-device-family, so ranges beyond those populations are not established; the row's third-dataset condition was met at build

Stamped: 2026-11-28.

Evidence published: 2003–2012.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In healthy adults, what is brachial-ankle pulse wave velocity — its distribution and age- and sex-specific reference ranges — and how do its values relate to (without being interchangeable with) carotid-femoral PWV?

Balance of the evidence

Textbook framing: Boron & Boulpaep, arterial mechanics (framing). Three primary datasets, all East-Asian and all using volume-plethysmographic baPWV devices, carded per dataset: 21,094 Chinese subjects whose healthy subgroup (no cardiovascular disease or risk factors) averaged 1,389.9 +/- 288.4 cm/s (13.90 m/s), with discrimination cut-offs of 1,450-1,566 cm/s; 12,517 Japanese subjects without medication or cardiovascular history, from whom 7,881 healthy subjects showed baPWV lower in women than men until age 60 and converging thereafter, rising on a quadratic curve with age; and — the third dataset whose verification the row made a build condition, VERIFIED from its fetched record — 974 healthy Northern Chinese subjects with decade upper limits rising from 1,394/1,264 cm/s (men/women, twenties) to 1,798/1,915 cm/s (sixties). baPWV includes a long peripheral muscular-artery path and runs systematically higher than carotid-femoral PWV (the aortic measure, pack #7065): the two scales must never be interchanged, and that contrast is this shelf's core teaching point. The stamp is graded down because every dataset is East-Asian and one device family — reference ranges outside those populations are not established by this base. PHYSIOLOGY — EMERGING.

MeSH: Ankle Brachial Index · Reference Values · Adult · Aged · Female · Humans · Male · Middle Aged · Age Factors · Sex Factors · Asian People · Cross-Sectional Studies

Cards (4)

Card 1 — Chinese distribution study (Wu 2012): 21,094 subjects — healthy subgroup baPWV averaged 1,389.9 +/- 288.4 cm/s (13.90 m/s); a cut-off of 1,450 cm/s discriminated cardiovascular disease or risk factors

Study: Primary human physiology study (baPWV distribution and age/sex reference ranges, Chinese population)

Population: 21,094 subjects recruited in a cross-sectional study in China (June 2007 to June 2008), divided into subgroup 1 (atherosclerotic cardiovascular disease), subgroup 2 (atherosclerotic risk factors) and subgroup 3 ('healthy subjects' with neither).

Summary: Chinese distribution study (Wu 2012): 21,094 subjects — healthy subgroup baPWV averaged 1,389.9 +/- 288.4 cm/s (13.90 m/s); a cut-off of 1,450 cm/s discriminated cardiovascular disease or risk factors

Result: Mean baPWV was 1,724.3 +/- 429.1 cm/s (17.24 m/s) in subgroup 1, 1,603.5 +/- 358.8 cm/s (16.04 m/s) in subgroup 2 and 1,389.9 +/- 288.4 cm/s (13.90 m/s) in healthy subgroup 3; baPWV was not normally distributed in either sex and rose significantly with age in both. In healthy subgroup 3 baPWV was lower in women than men (the reverse held in subgroup 2, and there was no sex difference in subgroup 1). Receiver-operating analysis gave a baPWV of 1,450 cm/s (14.50 m/s) to discriminate either cardiovascular disease or risk factors (sensitivity 62.1%, specificity 69.5%), 1,551 cm/s for cardiovascular disease and 1,566 cm/s for disease or chronic kidney disease.

Watch out: A mixed clinical population: only subgroup 3 is a healthy reference group, and the 1,450-1,566 cm/s figures are discrimination cut-offs against disease/risk status, not upper reference limits — do not quote them as normal limits.

Source: Wu L et al. Distribution of brachial-ankle pulse wave velocity values and optimal cut-off in distinguishing subjects with clinical condition in Chinese population. International angiology : a journal of the International Union of Angiology. 2012. PMID: 22634980. Registry ID: none in the record. MeSH: Adult · Aged · Ankle Brachial Index · Asian People · Atherosclerosis/diagnosis/physiopathology · Cross-Sectional Studies · Female · Humans · Male · Middle Aged · Reference Values

Card 2 — Japanese survey (Tomiyama 2003): 12,517 subjects without medication or cardiovascular history — in 7,881 healthy subjects baPWV was lower in women until age 60, then converged; the age relation was quadratic and steeper in women

Study: Primary human physiology study (baPWV age and sex influences, Japanese population survey)

Population: 12,517 subjects with no medication and no history of cardiovascular disease; from them, 7,881 'healthy subjects' (4,488 men and 3,393 women, aged 25-87 years) without any atherogenic risk factors were extracted and analysed in 5-year age intervals.

Summary: Japanese survey (Tomiyama 2003): 12,517 subjects without medication or cardiovascular history — in 7,881 healthy subjects baPWV was lower in women until age 60, then converged; the age relation was quadratic and steeper in women

Result: Multiple regression showed age, blood pressure, body mass index, triglycerides, blood glucose and uric acid were significant variables for baPWV in both sexes. In healthy subjects, baPWV was lower in women than in men until age 60 and became similar in both sexes over age 60; the effect of age on baPWV (both the explained variance and the regression coefficient) was larger in women than in men, and the age-baPWV relation followed a quadratic curve in both sexes. The authors suggest menopause is the crucial phenomenon behind the augmented rise in arterial stiffness with ageing in women. The fetched record does not print the 5-year-interval values in cm/s, and this card claims none.

Watch out: The oldest dataset on this shelf (2003, first-generation baPWV devices): its age/sex pattern is the content here, and its absolute values should be read beside the later Chinese datasets rather than pooled with them.

Source: Tomiyama H et al. Influences of age and gender on results of noninvasive brachial-ankle pulse wave velocity measurement--a survey of 12517 subjects. Atherosclerosis. 2003. PMID: 12535743. Registry ID: none in the record. MeSH: Adult · Age Factors · Aged · Aged, 80 and over · Anthropometry · Blood Pressure Determination · Cohort Studies · Data Collection · Female · Humans · Male · Middle Aged · Multivariate Analysis · Probability · Pulsatile Flow · Pulse · Reference Values · Regression Analysis · Sensitivity and Specificity · Sex Factors

Card 3 — Northern Chinese reference values (Wang 2009) — third dataset verified at build: 974 healthy subjects; upper limits by decade rose from 1,394/1,264 cm/s (men/women in their twenties) to 1,798/1,915 cm/s in their sixties

Study: Primary human physiology study (baPWV reference values by age and sex, Northern Chinese) — third primary dataset verified at build under the row's stop condition

Population: 974 identified healthy subjects recruited in an epidemiological study in north China, with baPWV measured noninvasively with an automatic (volume-plethysmographic) device; mean baPWV was higher in men overall (P<0.001), higher in men than women below age 50 but not in the older group.

Summary: Northern Chinese reference values (Wang 2009) — third dataset verified at build: 974 healthy subjects; upper limits by decade rose from 1,394/1,264 cm/s (men/women in their twenties) to 1,798/1,915 cm/s in their sixties

Result: Multiple regression showed age and systolic blood pressure were positively associated with baPWV in both sexes (P<0.001), and the effect of age on baPWV augmentation was greater in women. The upper limits of baPWV for healthy men/women at 10-year intervals (age range 20-70 years) were 1,394/1,264 cm/s (13.94/12.64 m/s), 1,435/1,361, 1,552/1,433, 1,597/1,609 and 1,798/1,915 cm/s (17.98/19.15 m/s) — women overtaking men in the oldest bands, consistent with the Japanese pattern above.

Watch out: The smallest of the three datasets (974 healthy subjects) and, like the others, East-Asian and single-device-family: these upper limits are references for comparable populations and devices, not universal baPWV limits.

Source: Wang X et al. Reference values of brachial-ankle pulse wave velocity for Northern Chinese. Chinese medical journal. 2009. PMID: 19781292. Registry ID: none in the record. MeSH: Adult · Age Factors · Aged · Ankle Brachial Index · Asian People · Female · Humans · Male · Middle Aged · Reference Values · Regression Analysis · Sex Factors

Card 4 — Synthesis: baPWV rises with age on a curve that steepens in women after midlife — healthy means near 13.9 m/s and decade upper limits to about 19 m/s in the oldest band — and baPWV is NOT carotid-femoral PWV

Study: Synthesis

Population: Synthesis of the three primary datasets carded above.

Summary: Synthesis: baPWV rises with age on a curve that steepens in women after midlife — healthy means near 13.9 m/s and decade upper limits to about 19 m/s in the oldest band — and baPWV is NOT carotid-femoral PWV

Result: Framed by Boron & Boulpaep (arterial mechanics). The three datasets agree: baPWV increases with age in both sexes (quadratically in the Japanese survey of 7,881 healthy subjects), is lower in women than men until about age 60 and then converges or overtakes (Northern Chinese upper limits 1,798 cm/s in men vs 1,915 cm/s in women in the sixties band), and is driven by age and systolic pressure above other factors. Absolute scale: the healthy Chinese subgroup averaged 1,389.9 cm/s (13.90 m/s). The row's stop condition was discharged at build: a third primary adult dataset (Wang 2009, PMID 19781292) was verified from its fetched record. Downgrade reason, on the face: all three datasets are East-Asian and use volume-plethysmographic baPWV devices, so ranges are EMERGING beyond those populations. Cross-point: carotid-femoral PWV reference values (pack #7065) measure the aortic path only and run systematically lower — never card baPWV values on cfPWV scales.

Watch out: Device must be named per dataset; a baPWV in cm/s converted to m/s is the same measurement, but a baPWV is never a cfPWV.

Source: Synthesis of the reports carded above; no additional source.