SourceMed · Shelf #7393 in the ask interface

Coagulation screening intervals: a common adult interval fits PT/INR, thrombin time and fibrinogen — minor age/sex variation in 1.78M data-mined samples — but aPTT is reagent- and analyser-specific

Shelf #7393 · Heart, vessels, blood pressure & clotting

PHYSIOLOGY — ESTABLISHED — four primary datasets (two very large indirect derivations, an over-60 verification study and an athlete verification study) agree the screening panel needs no sex partitioning and only minor age adjustment, while aPTT remains reagent/analyser-specific and no universal aPTT range is claimed

Stamped: 2026-11-28.

Evidence published: 2019–2025.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In healthy non-pregnant adults, what are the reference intervals for the coagulation screening tests — prothrombin time / INR, activated partial thromboplastin time, thrombin time and fibrinogen — by age (including older adults), sex, analyser and reagent, and how much do data-mined (indirect) intervals agree with directly recruited healthy-volunteer intervals?

Balance of the evidence

PHYSIOLOGY — ESTABLISHED. Textbook framing: Guyton & Hall, haemostasis chapters, and Boron & Boulpaep, blood sections (framing brief — this shelf rests chiefly on the primary reference-interval literature, and says so). Four datasets converge on the same practical picture: directly and indirectly derived intervals for PT/INR, aPTT, thrombin time and fibrinogen show only minor age and sex variation, supporting a common adult interval (Zierk 2019: 1,778,738 samples from 116,754 patients, data-mined; Wu 2025: 630,946 records, cross-platform), BUT aPTT intervals are batch-, reagent- and analyser-specific to a degree unusual among routine tests, so no universal aPTT range is printed here. In healthy people over 60 a proportion of aPTT and TEG results fell outside adult intervals while derived fibrinogen stayed inside them (Donkin 2020, n=60), and in 121 healthy young female athletes the fibrinogen interval ran higher (1.9–4.4 g/L (190–440 mg/dL)) than the national non-athlete interval (1.8–3.5 g/L (180–350 mg/dL)) while PT and aPTT-ratio intervals were confirmed (HemSter 2021). Pregnancy-specific intervals are a separate literature and are NOT this shelf.

MeSH: Adult · Aged · Aged, 80 and over · Blood Coagulation Tests/standards · Data Mining · Female · Germany · Humans · Male · Middle Aged · Reference Values · Young Adult · Australia · Blood Coagulation · Blood Coagulation Factors/analysis,standards · Blood Coagulation Tests/methods · Blood Transfusion · Fibrinogen/metabolism · Partial Thromboplastin Time · Prothrombin Time/methods · Thrombelastography/methods · Algorithms · Retrospective Studies · Age Factors · Adolescent · Child · Child, Preschool · Infant · Athletes · Biomarkers/blood · Fibrin Fibrinogen Degradation Products · Leukocyte Count · Prothrombin Time · Sports · Venous Thromboembolism/blood

Cards (5)

Card 1 — Data-mined intervals from 1,778,738 samples (116,754 adults): age- and sex-specific PT, INR, aPTT, thrombin time and fibrinogen intervals show only minor age/sex variation — a common adult interval is supported (Zierk 2019)

Study: Primary physiology / reference-interval study (indirect data-mining, single university hospital)

Population: Measurements of aPTT, PT, INR, thrombin time and fibrinogen performed during clinical care at University Hospital Erlangen, Germany — 1,778,738 samples from 116,754 adult patients (45,577–509,859 samples per analyte); the healthy proportion was identified statistically with the Reference Limit Estimator.

Summary: Data-mined intervals from 1,778,738 samples (116,754 adults): age- and sex-specific PT, INR, aPTT, thrombin time and fibrinogen intervals show only minor age/sex variation — a common adult interval is supported (Zierk 2019)

Result: Age- and sex-specific reference intervals were established for all five tests, plus batch- and reagent-specific aPTT intervals, and the sensitivity of the aPTT intervals for detecting factor VIII, IX, XI and XII deficiencies was evaluated. The established intervals showed only minor variation with sex and age, supporting a common reference interval for adult women and men. The authors stress the intervals are specific to the population, analytical framework and reagent examined. The fetched record does not print the numeric interval limits, and this card claims none.

Watch out: Indirect method: intervals are modelled out of routine clinical samples, not measured in recruited healthy volunteers, and are explicitly reagent- and framework-specific — especially for aPTT.

Source: Zierk J et al. Data mining of reference intervals for coagulation screening tests in adult patients. Clinica chimica acta; international journal of clinical chemistry. 2019. PMID: 31513787. Registry ID: none in the record. MeSH: Adult · Aged · Aged, 80 and over · Blood Coagulation Tests/standards · Data Mining · Female · Germany · Humans · Male · Middle Aged · Reference Values · Young Adult

Card 2 — Healthy donors over 60 (n=60): all derived-fibrinogen results fell inside adult intervals (higher in women), but a proportion of aPTT and TEG 6s results fell outside them (Donkin 2020)

Study: Primary physiology / reference-interval verification study (healthy donors over 60)

Population: Healthy blood donors aged over 60 years (30 men, 30 women), tested by TEG 6s, prothrombin time, activated partial thromboplastin time and derived fibrinogen, compared against adult reference intervals with no upper age limit.

Summary: Healthy donors over 60 (n=60): all derived-fibrinogen results fell inside adult intervals (higher in women), but a proportion of aPTT and TEG 6s results fell outside them (Donkin 2020)

Result: All older-donor derived fibrinogen results were within the adult reference intervals, although levels were significantly higher in females. A proportion of TEG 6s and aPTT results were NOT within the reference intervals. The authors question whether older adults require age-specific coagulation reference intervals.

Watch out: Small verification sample (n=60) and a proportion-outside finding without printed percentages in the fetched record — it raises the age-specific question, it does not settle new elderly limits.

Source: Donkin R et al. Investigating Age Appropriate Coagulation Reference Intervals to Support Patient Blood Management in the Elderly: A Verification Study. Annals of clinical and laboratory science. 2020. PMID: 32826254. Registry ID: none in the record. MeSH: Aged · Aged, 80 and over · Australia · Blood Coagulation · Blood Coagulation Factors/analysis,standards · Blood Coagulation Tests/methods · Blood Transfusion · Female · Fibrinogen/metabolism · Humans · Male · Middle Aged · Partial Thromboplastin Time · Prothrombin Time/methods · Reference Values · Thrombelastography/methods

Card 3 — 630,946 Chinese records, 11 indirect algorithms, two platforms: Z-Score and Tukey performed best for 8 coagulation parameters; sex stratification unnecessary, age stratification needed for D-dimer at ≥60 years (Wu 2025)

Study: Primary physiology / reference-interval study (indirect multi-algorithm framework, cross-platform)

Population: 630,946 coagulation test records from Shenzhen Hospital of Southern Medical University, analysed retrospectively with eleven outlier-detection algorithms; validated across Mindray CX-9000 and Stago STA R Max platforms against manufacturer standards.

Summary: 630,946 Chinese records, 11 indirect algorithms, two platforms: Z-Score and Tukey performed best for 8 coagulation parameters; sex stratification unnecessary, age stratification needed for D-dimer at ≥60 years (Wu 2025)

Result: Z-Score and Tukey algorithms showed optimal performance for 8 coagulation parameters, yielding intervals with minimal deviation from manufacturer standards. Sex differences were minimal (standard deviation ratio <0.40, Cohen's d <0.50), eliminating the need for sex stratification. Age stratification WAS required for D-dimer (≥60-year subgroup: SDR 0.62, Cohen's d 0.54). Cross-platform consistency confirmed the algorithms generalise.

Watch out: An algorithm-comparison study: its 'universal' claim is about the derivation method, not about one set of limits fitting every analyser — D-dimer is carded here only as the age-stratification limb of the panel, not as a standalone D-dimer norms claim.

Source: Wu Y et al. An integrated framework for universal coagulation test reference intervals: Cross-platform validation of eleven indirect algorithms and age-specific hierarchical optimization. Clinica chimica acta; international journal of clinical chemistry. 2025. PMID: 40499770. Registry ID: none in the record. MeSH: Humans · Female · Male · Algorithms · Blood Coagulation Tests/standards · Middle Aged · Adult · Reference Values · Aged · Retrospective Studies · Young Adult · Adolescent · Age Factors · Aged, 80 and over · Child · Child, Preschool · Infant

Card 4 — HemSter verification in 121 healthy young female athletes: PT and aPTT-ratio intervals confirmed, but fibrinogen ran higher — 1.9–4.4 g/L (190–440 mg/dL) vs the national 1.8–3.5 g/L (180–350 mg/dL) (Radišić Biljak 2021)

Study: Supporting limb: reference-interval verification study (healthy young female athletes)

Population: 121 female athletes aged 16–34 from water polo, handball, volleyball, football and basketball; fasting morning samples before activity; intervals determined per CLSI EP28-A3C and compared with common national reference intervals.

Summary: HemSter verification in 121 healthy young female athletes: PT and aPTT-ratio intervals confirmed, but fibrinogen ran higher — 1.9–4.4 g/L (190–440 mg/dL) vs the national 1.8–3.5 g/L (180–350 mg/dL) (Radišić Biljak 2021)

Result: Calculated intervals for white cell count, prothrombin time and aPTT ratio accorded with the common national intervals. The fibrinogen interval was higher (1.9–4.4 g/L (190–440 mg/dL)) than the available interval (1.8–3.5 g/L (180–350 mg/dL)); the CRP interval was lower (<2.9 mg/L vs a <5.0 mg/L healthy cut-off) and the D-dimer cut-off derived was 852 µg/L FEU, above the proposed 500 µg/L FEU for venous thromboembolism exclusion — a value the authors say needs extensive verification before use in athletes.

Watch out: A young athletic female population is not the general adult population: the fibrinogen and D-dimer departures describe athletes, and the D-dimer figure must never be used as a general VTE-exclusion cut-off.

Source: Radišić Biljak V et al. Women in sports: the applicability of common national reference intervals for inflammatory and coagulation biomarkers (HemSter Study). Biochemia medica. 2021. PMID: 33380889. Registry ID: none in the record. MeSH: Adolescent · Adult · Athletes · Biomarkers/blood · Blood Coagulation · Female · Fibrin Fibrinogen Degradation Products · Humans · Leukocyte Count · Partial Thromboplastin Time · Prothrombin Time · Sports · Venous Thromboembolism/blood

Card 5 — Synthesis: coagulation screening intervals are a common adult interval in practice — minor age/sex variation across 1.78 million data-mined samples and 630,946 algorithm-derived records — with aPTT bound to its reagent and analyser, and fibrinogen running higher in older women and in young athletes

Study: Synthesis

Population: All datasets carded on this shelf.

Summary: Synthesis: coagulation screening intervals are a common adult interval in practice — minor age/sex variation across 1.78 million data-mined samples and 630,946 algorithm-derived records — with aPTT bound to its reagent and analyser, and fibrinogen running higher in older women and in young athletes

Result: Framed by Guyton & Hall (haemostasis) and Boron & Boulpaep (blood) — framing brief; the shelf rests on the primary interval literature. Zierk 2019 and Wu 2025, the two very large indirect datasets, agree that sex partitioning is unnecessary and age effects are minor for the screening panel (D-dimer excepted at ≥60 years in Wu). Donkin 2020 (n=60 over-60s) is the caution: a proportion of aPTT results fell outside adult intervals in healthy older donors. HemSter 2021 confirms PT and aPTT-ratio intervals in athletes while fibrinogen runs higher. Fibrinogen is carded only as one limb of this screening panel, on the strength of these panel datasets. PHYSIOLOGY — ESTABLISHED for the panel structure and the common-adult-interval conclusion; no universal numeric aPTT range is asserted, because aPTT is reagent- and analyser-specific.

Watch out: Never print one platform's aPTT limits as universal, and never merge directly recruited healthy-volunteer intervals with data-mined indirect intervals without labelling the method — the two approaches are carded separately here by design.

Source: Synthesis of the reports carded above; no additional source.