SourceMed · Shelf #7456 in the ask interface
CMR chamber reference ranges: LV end-diastolic volume 160 ± 29 mL in men vs 135 ± 26 mL in women (SSFP), UK Biobank LV ejection fraction 61% women vs 58% men — ranges must be normalised to sex, body size and age
Shelf #7456 · Heart, vessels, blood pressure & clotting
PHYSIOLOGY — EMERGING — three independent SSFP CMR cohorts agree on the sex, age and indexing structure of normal chamber values, but contouring conventions move the limits materially, one record prints no numeric ranges in its abstract, and the largest cohort is Caucasian and aged 45-74 only
Stamped: 2026-11-28.
Evidence published: 2005–2017.
Last source check: 2026-11-26.
Source correction status: no correction or retraction found at the last source check (2026-11-26).
Question
In healthy adults, what are the cardiovascular magnetic resonance (CMR) reference ranges for cardiac chamber structure and function — left- and right-ventricular volumes, mass and ejection fraction, and atrial dimensions, indexed to body surface area — by age and sex, and how much do cohort, contouring convention and indexing move the limits of normal?
Balance of the evidence
Textbook framing: Guyton & Hall, cardiac muscle and circulation chapters — the framing is brief, and this shelf rests chiefly on the primary CMR reference literature, and says so. Three independent steady-state free-precession (SSFP) cohorts: 108 healthy volunteers with manually analysed LV, RV and left-atrial dimensions (Hudsmith 2005 — LV end-diastolic volume 160 ± 29 mL in men vs 135 ± 26 mL in women); a normalised-range modelling study whose fetched abstract prints no cohort N and no numeric ranges, carded for its normalisation principle only (Maceira 2006); and the UK Biobank cohort (Petersen 2017 — 5,065 scanned at 1.5 T, 804 in the healthy Caucasian reference cohort aged 45-74, LV ejection fraction 61 ± 5% in women vs 58 ± 5% in men, indexed LV mass 42 ± 7 vs 53 ± 9 g/m2). Contouring convention (papillary muscles and trabeculations) and indexing move the limits materially and are stated per card; SSFP CMR values are not interchangeable with echocardiographic volumes — the speckle-tracking strain shelf #7163 is the echo cross-point, a different modality and measure. The stamp is graded down: one of three records prints no numbers in its abstract, and the largest cohort is Caucasian and aged 45-74 only. PHYSIOLOGY — EMERGING.
MeSH: Adult · Age Factors · Aged · Female · Humans · Magnetic Resonance Imaging · Male · Middle Aged · Reference Values · Sex Factors · Stroke Volume · Ventricular Function, Left · Ventricular Function, Right
Cards (4)
Card 1 — Hudsmith 2005: SSFP CMR in 108 healthy volunteers — LV end-diastolic volume 160 ± 29 mL in men vs 135 ± 26 mL in women; RV end-diastolic volume 190 ± 33 vs 148 ± 35 mL
Study: Primary human physiology study (SSFP CMR reference database, healthy volunteers)
Population: 108 healthy volunteers (63 men, 45 women) across a wide age range, imaged with steady-state free-precession CMR; manual analysis by two experienced observers, covering left- and right-ventricular volumes, LV mass and left-atrial dimensions.
Summary: Hudsmith 2005: SSFP CMR in 108 healthy volunteers — LV end-diastolic volume 160 ± 29 mL in men vs 135 ± 26 mL in women; RV end-diastolic volume 190 ± 33 vs 148 ± 35 mL
Result: Ventricular volumes and LV mass were larger in men: LV end-diastolic volume 160 ± 29 mL vs 135 ± 26 mL, LV end-systolic volume 50 ± 16 vs 42 ± 12 mL, RV end-diastolic volume 190 ± 33 vs 148 ± 35 mL and RV end-systolic volume 78 ± 20 vs 56 ± 18 mL (p<0.05 for all). Normalising to body surface area removed the statistical sex differences for LV volumes, but not for LV mass or RV volumes. With age, men showed significant decreases in volume and mass indices for both ventricles, while women's values remained unchanged. Maximal left-atrial volume was 103 ± 30 mL in men vs 89 ± 21 mL in women (p=0.01) and left-atrial stroke volume 58 ± 23 vs 48 ± 15 mL (p=0.01), with no sex difference in left-atrial ejection fraction.
Watch out: Manual contouring by two observers in the early SSFP era: whether papillary muscles and trabeculations are included in mass or volume moves both, so these ranges travel with their contouring convention and are not interchangeable with later automated or echocardiographic values.
Source: Hudsmith LE et al. Normal human left and right ventricular and left atrial dimensions using steady state free precession magnetic resonance imaging. Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance. 2005. PMID: 16353438. Registry ID: none in the record. MeSH: Adult · Age Factors · Aged · Atrial Function, Left · Female · Heart Atria/anatomy & histology · Heart Ventricles/anatomy & histology · Humans · Hypertrophy, Left Ventricular/pathology · Image Processing, Computer-Assisted · Magnetic Resonance Imaging · Male · Middle Aged · Observer Variation · Reproducibility of Results · Sex Factors · Stroke Volume · Ventricular Function
Card 2 — Maceira 2006: normalised LV ranges must be modelled against sex, body surface area AND age together — the fetched record prints no cohort N and no numeric ranges, and none are claimed
Study: Primary human physiology study (SSFP CMR normalised LV reference ranges — modelling report)
Population: Healthy volunteers imaged with state-of-the-art SSFP cardiovascular magnetic resonance to define normal left-ventricular volumes and systolic and diastolic function; the cohort size is not printed in the fetched abstract.
Summary: Maceira 2006: normalised LV ranges must be modelled against sex, body surface area AND age together — the fetched record prints no cohort N and no numeric ranges, and none are claimed
Result: Normalised CMR reference ranges were modelled and displayed in graphical form for clinical use, with normalisation for body surface area, sex and age together. The authors' central point is methodological: determination of normality, or of the severity of abnormality, depends on using reference ranges normalised to all three variables. The fetched record states this modelling approach and its purpose; it does not print the cohort N or the numeric range limits, and this card claims none.
Watch out: Carded for the normalisation principle only: a single pooled 'normal LV volume' that ignores sex, body size and age is exactly what this study argues against. Any numeric limit must come from the datasets that print numbers (the other two cards).
Source: Maceira AM et al. Normalized left ventricular systolic and diastolic function by steady state free precession cardiovascular magnetic resonance. Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance. 2006. PMID: 16755827. Registry ID: none in the record. MeSH: Adult · Age Factors · Aged · Aged, 80 and over · Analysis of Variance · Diastole/physiology · Female · Humans · Image Processing, Computer-Assisted · Linear Models · Magnetic Resonance Imaging/methods · Male · Middle Aged · Reference Values · Sex Factors · Statistics, Nonparametric · Systole/physiology · Ventricular Function, Left/physiology
Card 3 — UK Biobank (Petersen 2017): reference ranges for all four chambers from 804 healthy Caucasian adults aged 45-74 (of 5,065 scanned) — LV ejection fraction 61 ± 5% in women vs 58 ± 5% in men; indexed LV mass 42 ± 7 vs 53 ± 9 g/m2
Study: Primary human physiology study (UK Biobank CMR reference ranges, all four chambers)
Population: 5,065 UK Biobank participants underwent SSFP CMR at 1.5 T with manual analysis of all four chambers; after excluding non-Caucasian ethnicity, known cardiovascular disease and other conditions affecting chamber size and function, 804 participants (16.2%, as published) formed the healthy reference cohort, with ranges stratified by sex and age band (45-54, 55-64, 65-74 years).
Summary: UK Biobank (Petersen 2017): reference ranges for all four chambers from 804 healthy Caucasian adults aged 45-74 (of 5,065 scanned) — LV ejection fraction 61 ± 5% in women vs 58 ± 5% in men; indexed LV mass 42 ± 7 vs 53 ± 9 g/m2
Result: LV volumes were larger in men for absolute and indexed values and mostly smaller with advancing age in both sexes. LV ejection fraction was significantly greater in women than men (mean ± SD 61 ± 5% vs 58 ± 5%) and remained static with age. Indexed LV mass was significantly higher in men (53 ± 9 g/m2) than women (42 ± 7 g/m2); in older age groups LV mass was lower in men but virtually unchanged in women. RV volumes were significantly larger in men, absolute and indexed, and smaller with advancing age; RV ejection fraction rose with age in women only. Left-atrial maximal volume and stroke volume were larger in men in absolute values but not indexed values, with similar LA ejection fraction; right-atrial maximal volume was larger in men absolute and indexed, and RA ejection fraction higher in women.
Watch out: The reference cohort is Caucasian and aged 45-74 only — these are not young-adult or multi-ethnic ranges, and the healthy subset (804) is far smaller than the scanned total (5,065); both numbers are printed so the subset is not mistaken for the whole.
Source: Petersen SE et al. Reference ranges for cardiac structure and function using cardiovascular magnetic resonance (CMR) in Caucasians from the UK Biobank population cohort. Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance. 2017. PMID: 28178995. Registry ID: none in the record. MeSH: Age Factors · Aged · Atrial Function, Left · Atrial Function, Right · Biological Specimen Banks · Female · Heart/diagnostic imaging,physiology · Humans · Magnetic Resonance Imaging/standards · Male · Middle Aged · Observer Variation · Predictive Value of Tests · Reference Values · Reproducibility of Results · Sex Factors · Stroke Volume · United Kingdom · Ventricular Function, Left · Ventricular Function, Right · White People
Card 4 — Synthesis: SSFP CMR volumes are larger in men (LV end-diastolic 160 vs 135 mL), indexing to body surface area removes the LV volume sex gap but not the mass or RV gaps, and usable ranges must be normalised to sex, body size and age together
Study: Synthesis
Population: Synthesis of the three cohorts carded above.
Summary: Synthesis: SSFP CMR volumes are larger in men (LV end-diastolic 160 vs 135 mL), indexing to body surface area removes the LV volume sex gap but not the mass or RV gaps, and usable ranges must be normalised to sex, body size and age together
Result: Framed by Guyton & Hall (cardiac muscle / circulation; framing brief — this shelf rests chiefly on the primary CMR reference literature). Hudsmith's 108 volunteers set the absolute scale (LV end-diastolic volume 160 ± 29 mL men, 135 ± 26 mL women; RV end-diastolic 190 ± 33 vs 148 ± 35 mL). Maceira's modelling establishes that ranges must be normalised to sex, body surface area and age jointly. UK Biobank's 804-person healthy reference cohort extends the ranges to all four chambers at ages 45-74 (LV ejection fraction 61 ± 5% women, 58 ± 5% men; indexed LV mass 42 ± 7 vs 53 ± 9 g/m2). Echocardiographic deformation (global longitudinal strain) is homed at pack #7163 and resting pulmonary artery pressures at pack #7165 — neither is re-carded here. PHYSIOLOGY — EMERGING: contouring conventions move volumes and mass materially, one carded record prints no numeric ranges in its abstract, and the largest cohort is single-ethnicity and aged 45-74.
Watch out: Never apply a CMR range across contouring conventions or to echocardiographic volumes; age and sex strata are part of the range, not adjustments after the fact.
Source: Synthesis of the reports carded above; no additional source.