TCD normal velocities: MCA 58 ± 15.6 cm/s by conventional TCD (106 volunteers, falling with age); women-only MCA ≈68 cm/s falling to ≈60 after 50; angle-corrected duplex MCA range 37.7–112.5 cm/s

Shelf #7508 · Brain, stroke & mind

PHYSIOLOGY — EMERGING

Stamped: 2026-11-28.

Evidence published: 1990–2020.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In healthy adults, what are the normal transcranial Doppler (TCD) blood-flow velocities — mean velocities in the middle cerebral, anterior and posterior cerebral, carotid siphon and basilar arteries — by age and sex, and how much do insonation-angle correction (transcranial colour-coded duplex) and age move them?

Balance of the evidence

Textbook framing: Boron & Boulpaep / Guyton & Hall, cerebral circulation sections — the framing is brief, and this shelf rests chiefly on the primary normative ultrasound literature, and says so. Three independent adult datasets, carded PER METHOD because conventional transcranial Doppler (uncorrected insonation angle) and transcranial colour-coded duplex (angle-corrected) velocities are not interchangeable: the 1990 conventional-TCD dataset of 106 normal volunteers (middle cerebral artery M1 mean 58 ± 15.6 cm/s, posterior cerebral 39 ± 9.9, carotid siphon 47 ± 13.8, basilar trunk 41 ± 10, with a marked decrease with age and low side-to-side differences); a women-only dataset of 100 healthy Italian women (middle cerebral mean ≈67–68 cm/s overall, falling from ≈81–83 cm/s under 20 years to ≈59–61 cm/s over 50 — labelled women-only on its card); and a 2020 colour-coded-duplex dataset (195 enrolled, 162 analysed) whose angle-corrected 2.5th–97.5th percentile ranges (middle cerebral 37.7–112.5 cm/s; anterior cerebral 25.6–71.2; posterior cerebral 29.2–80.8) differ widely from its own 0° values. The paediatric dataset and the normative-ranges book chapter named at mining are NOT carded — a secondary source and a different population, respectively. The stamp is graded down because the total base is three datasets, one is women-only, one predates colour-coded duplex, and the method split means there is no single method-free normal velocity. PHYSIOLOGY — EMERGING.

MeSH: Adolescent · Adult · Aged · Blood Flow Velocity/physiology · Brain/anatomy & histology,blood supply · Cephalometry · Cerebral Arteries/anatomy & histology,diagnostic imaging,physiology · Child · Echoencephalography · Humans · Middle Aged · Reference Values · Skull/anatomy & histology,diagnostic imaging · Vertebral Artery/anatomy & histology,diagnostic imaging,physiology

Cards (4)

Card 1 — First normative dataset, conventional TCD (Ringelstein 1990, 106 normal volunteers): mean flow velocities — MCA M1 segment 58 ± 15.6 cm/s, posterior cerebral 39 ± 9.9, carotid siphon 47 ± 13.8, basilar trunk 41 ± 10 — with a marked decrease with age and low side-to-side differences

Study: Primary human physiology dataset (conventional transcranial Doppler normative velocities and insonation landmarks, 106 normal volunteers)

Population: 106 normal volunteers examined by transcranial Doppler sonography, within a study that also elaborated anatomical landmarks from 64 carotid and 42 vertebral angiograms, 40 contrast-enhanced CT scans, 122 normal sagittal MRI scans, 40 cadaver skulls and 38 fresh cadavers, plus 59 patients with subclavian steal mechanisms. Insonation depths are part of the normative data: inner internal carotid bifurcation 60.4 ± 7 mm, M1 segment 40 ± 8 to 60.4 ± 7 mm, carotid siphon C3 segment 62 ± 4 mm, vertebral artery junction 84 ± 8 mm, top of the basilar artery 108 ± 8 mm.

Summary: First normative dataset, conventional TCD (Ringelstein 1990, 106 normal volunteers): mean flow velocities — MCA M1 segment 58 ± 15.6 cm/s, posterior cerebral 39 ± 9.9, carotid siphon 47 ± 13.8, basilar trunk 41 ± 10 — with a marked decrease with age and low side-to-side differences

Result: Normal mean flow velocities were 58 ± 15.6 cm/s in the M1 segment of the middle cerebral artery, 39 ± 9.9 cm/s in the posterior cerebral artery, 47 ± 13.8 cm/s in the carotid siphon and 41 ± 10 cm/s in the basilar trunk, and revealed a marked decrease with age. Intraindividual side-to-side differences were low. Vertebrobasilar data from neuroradiological material closely matched the in-vivo findings in normals and patients, and the paper provides criteria for identifying the various vessel segments.

Watch out: Conventional (blind, angle-uncorrected) TCD from 1990: these means are the reference for that technique only. The colour-coded card below shows how far angle correction moves the numbers, so a 1990 mean must never be applied as a cut-off to an angle-corrected duplex measurement.

Source: Ringelstein EB et al. Transcranial Doppler sonography: anatomical landmarks and normal velocity values. Ultrasound in medicine & biology. 1990. PMID: 2095006. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Blood Flow Velocity/physiology · Brain/anatomy & histology,blood supply · Cephalometry · Cerebral Arteries/anatomy & histology,diagnostic imaging,physiology · Child · Echoencephalography · Humans · Middle Aged · Reference Values · Skull/anatomy & histology,diagnostic imaging · Vertebral Artery/anatomy & histology,diagnostic imaging,physiology

Card 2 — Women-only normative dataset (Liboni 2006, 100 healthy Italian women): MCA mean velocity 68.06 ± 9.22 cm/s (left) and 66.71 ± 8.79 (right) overall, falling with age from 82.55 ± 6.85 (left, under 20 years) to 60.67 ± 6.85 (over 50 years) — labelled women-only

Study: Primary human physiology dataset (transcranial Doppler MCA normative ranges across the lifespan, women only)

Population: 100 healthy women (mean age 38 ± 15.14 years, range 12–78) in Italy, examined by transcranial Doppler of the middle cerebral artery and subdivided into four age groups: under 20 years, 20–34, 35–50, and over 50 years. A women-only dataset, labelled as such; it includes adolescents at the youngest end, and the adult age bands are the carded content.

Summary: Women-only normative dataset (Liboni 2006, 100 healthy Italian women): MCA mean velocity 68.06 ± 9.22 cm/s (left) and 66.71 ± 8.79 (right) overall, falling with age from 82.55 ± 6.85 (left, under 20 years) to 60.67 ± 6.85 (over 50 years) — labelled women-only

Result: There was no statistically significant difference between mean blood-flow velocity in the left and right middle cerebral arteries (left 68.06 ± 9.22 cm/s; right 66.71 ± 8.79 cm/s). Velocities decreased significantly with increasing age: left/right MCA 82.55 ± 6.85 / 80.27 ± 4.13 cm/s in the youngest group; 72.15 ± 6.37 / 70.68 ± 6.79 cm/s at 20–34 years; 63.85 ± 7.08 / 63.06 ± 7.29 cm/s at 35–50 years; and 60.67 ± 6.85 / 59.10 ± 5.36 cm/s over 50 years. The study defines a normal age-related range of MCA velocities for comparison with pathological female subjects.

Watch out: Women only, one vessel (the middle cerebral artery), and one national population: it cannot supply male norms or norms for the anterior/posterior cerebral, siphon or basilar arteries. Its overall MCA mean (≈67–68 cm/s) sits above the 1990 mixed-sex M1 mean (58 cm/s) — a sex-, era- and technique-bound difference, not a contradiction to be averaged away.

Source: Liboni W et al. Transcranial Doppler for monitoring the cerebral blood flow dynamics: normal ranges in the Italian female population. Panminerva medica. 2006. PMID: 17122755. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Aging/physiology · Blood Flow Velocity · Cerebrovascular Circulation · Child · Female · Humans · Italy · Middle Aged · Reference Values · Ultrasonography, Doppler, Transcranial

Card 3 — Angle-corrected colour-coded duplex norms (Barrientos-Guerra 2020, 195 healthy adults enrolled, 162 analysed): after insonation-angle correction, 2.5th–97.5th percentile velocity ranges were MCA 37.7–112.5 cm/s, ACA 25.6–71.2 and PCA 29.2–80.8 — with wide discrepancies from the uncorrected 0° values

Study: Primary human physiology dataset (transcranial colour-coded duplex normative values with insonation-angle correction, three age groups)

Population: 195 healthy adults equally allocated to three age groups (18–40, 41–60, ≥61 years), studied by conventional pulsed transcranial Doppler and transcranial colour-coded sonography (TCCS) through the temporal window; 33 were excluded (inadequate acoustic window 10.3%, carotid disease 2.1%, embryonic variants 4.6%), leaving 162 for the final analysis (50% female, median age 48 years). Peak systolic, end-diastolic and mean velocities and pulsatility/resistance indices were registered at 0° and after angle correction.

Summary: Angle-corrected colour-coded duplex norms (Barrientos-Guerra 2020, 195 healthy adults enrolled, 162 analysed): after insonation-angle correction, 2.5th–97.5th percentile velocity ranges were MCA 37.7–112.5 cm/s, ACA 25.6–71.2 and PCA 29.2–80.8 — with wide discrepancies from the uncorrected 0° values

Result: The 2.5th–97.5th percentiles of the corrected insonation angle were 0°–60° for the middle cerebral artery, 0°–44° for the anterior cerebral artery and 30°–60° for the posterior cerebral artery. After angle correction, the 2.5th–97.5th percentile flow-velocity ranges were 37.7–112.5 cm/s (MCA), 25.6–71.2 cm/s (ACA) and 29.2–80.8 cm/s (PCA). There were wide discrepancies between haemodynamic values obtained at 0° and after angle correction; no differences were found between methods at exactly 0° or between hemispheres, but values differed by age and sex. The authors conclude that specific normative tables should be used in TCCS whenever the corrected angle is greater than 0°.

Watch out: The method lesson is the content: angle correction is not a refinement of the same number but a different number — the corrected MCA range (up to 112.5 cm/s) would read as abnormal against uncorrected norms. One in ten healthy adults (10.3%) had an inadequate temporal acoustic window and contributes no values at all.

Source: Barrientos-Guerra JD et al. Evaluation of Cerebral Hemodynamics with Color-Coded Duplex Sonography: Normative Values with Correction of Insonation Angles. Journal of stroke and cerebrovascular diseases : the official journal of National Stroke Association. 2020. PMID: 31917090. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Anterior Cerebral Artery/diagnostic imaging,physiology · Blood Flow Velocity · Cerebrovascular Circulation · Cross-Sectional Studies · Female · Healthy Volunteers · Hemodynamics · Humans · Male · Middle Aged · Middle Cerebral Artery/diagnostic imaging,physiology · Posterior Cerebral Artery/diagnostic imaging,physiology · Predictive Value of Tests · Prospective Studies · Reference Values · Ultrasonography, Doppler, Color · Ultrasonography, Doppler, Transcranial · Young Adult

Card 4 — Synthesis: normal TCD velocities are method-bound — conventional TCD centres the MCA near 58 cm/s with a clear age decline, women-only MCA data run higher and fall from ≈82 to ≈60 cm/s across adult life, and angle-corrected duplex ranges are far wider and higher

Study: Synthesis

Population: Synthesis of the three primary datasets carded above.

Summary: Synthesis: normal TCD velocities are method-bound — conventional TCD centres the MCA near 58 cm/s with a clear age decline, women-only MCA data run higher and fall from ≈82 to ≈60 cm/s across adult life, and angle-corrected duplex ranges are far wider and higher

Result: Framed by Boron & Boulpaep / Guyton & Hall (cerebral circulation; framing brief — this shelf rests chiefly on the primary normative ultrasound literature). All three datasets agree on the qualitative physiology: velocities fall with age, and side-to-side differences within a person are small. They do not yield one universal number: Ringelstein 1990 (conventional TCD, 106 volunteers) gives MCA M1 58 ± 15.6, PCA 39 ± 9.9, siphon 47 ± 13.8 and basilar 41 ± 10 cm/s; Liboni 2006 (women only, 100) gives an overall MCA mean of ≈67–68 cm/s declining by age band; Barrientos-Guerra 2020 (colour-coded duplex, 162 analysed) shows angle correction widening and raising the ranges (MCA 37.7–112.5 cm/s). PHYSIOLOGY — EMERGING: the adult normative base is three datasets, one women-only and one from the pre-duplex era, and every value is bound to its insonation method, as printed on each card.

Watch out: Never apply an uncorrected-TCD reference range to an angle-corrected duplex study or vice versa, and never use the women-only MCA ranges as male norms.

Source: Synthesis of the reports carded above; no additional source.