Normal liver stiffness by transient elastography: screened-healthy ranges 2.3–5.9 kPa (Hong Kong) and 3.9–5.3 kPa (Korean donors) vs 3.2–8.5 kPa in a free-living population

Shelf #7545 · Liver & gut

PHYSIOLOGY — ESTABLISHED

Stamped: 2026-11-28.

Evidence published: 2008–2013.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In healthy adults, what are the normal values for liver stiffness measured by transient elastography (FibroScan) — mean, spread and 5th–95th percentile range in kilopascals — by sex, body-mass index and metabolic status, and how far do screened-healthy reference ranges sit below general-population values that include people with the metabolic syndrome?

Balance of the evidence

Textbook framing: Guyton & Hall / Boron & Boulpaep, gastrointestinal / hepatic sections — the framing is brief, and this shelf rests chiefly on the primary elastography reference literature, and says so. Four independent populations, and the reference-population definition moves the upper limit more than the device does. Screened-healthy ranges are tight: 2.3–5.9 kPa in 530 rigorously screened Hong Kong Chinese volunteers (mean 4.1 kPa) and a 5th–95th percentile range of 3.9–5.3 kPa in 69 healthy Korean living donors (mean 4.6 kPa). Less-screened general populations run higher and wider: mean 5.49 kPa in 429 French check-up attendees, with metabolic syndrome at 6.51 kPa after adjustment; and a 5th–95th percentile range of 3.2–8.5 kPa in 437 healthy Indian adults, in whom both lean and obese subjects were stiffer than normal-BMI subjects. The screened Hong Kong ceiling (5.9 kPa) and the unscreened Indian ceiling (8.5 kPa) are different kinds of 'normal' and are never merged on this shelf. All values are transient-elastography (FibroScan) values in kilopascals — not interchangeable with MR-elastography or shear-wave values — and measurement failure rises steeply with BMI (4.6% overall, 88% at BMI >40 in the French cohort). PHYSIOLOGY — ESTABLISHED.

MeSH: Adult · Age Factors · Body Mass Index · Elasticity · Female · Humans · Liver · Male · Metabolic Syndrome · Middle Aged · Prognosis · Prospective Studies · Reference Values · Risk Factors · Sex Factors · Ultrasonography · Adolescent · Asian People · Elasticity Imaging Techniques · Hong Kong · Living Donors · Republic of Korea · Tissue Donors · Young Adult · Case-Control Studies · Developing Countries · India · Liver Cirrhosis · Liver Diseases · Obesity · ROC Curve

Cards (5)

Card 1 — General-population check-up cohort (Roulot 2008): mean liver stiffness 5.49 ± 1.59 kPa in 429 apparently healthy adults — men 5.81 vs women 5.23 kPa; metabolic syndrome 6.51 vs 5.33 kPa after adjustment; measurement failure 88% at BMI >40

Study: Primary human physiology study (transient-elastography liver stiffness, general-population check-up cohort)

Population: 429 consecutive apparently healthy adults with no overt cause of liver disease and normal liver enzymes, undergoing a free medical check-up (prospective study); liver stiffness measured by transient elastography. The metabolic syndrome was present in 59 subjects (13.7%).

Summary: General-population check-up cohort (Roulot 2008): mean liver stiffness 5.49 ± 1.59 kPa in 429 apparently healthy adults — men 5.81 vs women 5.23 kPa; metabolic syndrome 6.51 vs 5.33 kPa after adjustment; measurement failure 88% at BMI >40

Result: Mean liver stiffness was 5.49 ± 1.59 kPa. Values were higher in men than women (5.81 ± 1.54 vs 5.23 ± 1.59 kPa, P = 0.0002) and in subjects with BMI >30 kg/m² (6.26 ± 1.89 vs 5.37 ± 1.51 kPa, P = 0.0003). After adjustment for sex and BMI, stiffness was higher with the metabolic syndrome than without (6.51 ± 1.64 vs 5.33 ± 1.51 kPa, P < 0.0001). Transient elastography failed in 4.6% of cases overall, and the failure rate rose with BMI, reaching 88% above 40 kg/m².

Watch out: 'Apparently healthy' check-up attendees, not a rigorously screened reference population — 13.7% had the metabolic syndrome, which is exactly why this cohort's values sit above the screened cohorts below; its failure rate at high BMI is part of the number.

Source: Roulot D et al. Liver stiffness values in apparently healthy subjects: influence of gender and metabolic syndrome. Journal of hepatology. 2008. PMID: 18222014. Registry ID: none in the record. MeSH: Adult · Age Factors · Body Mass Index · Elasticity · Female · Humans · Liver · Male · Metabolic Syndrome · Middle Aged · Prognosis · Prospective Studies · Reference Values · Risk Factors · Sex Factors · Ultrasonography

Card 2 — Rigorously screened Hong Kong cohort (Fung 2013): reference range 2.3–5.9 kPa (mean 4.1 ± 0.89) in the 530 volunteers retained from 2,528 after exclusions; median stiffness fell with age, 4.2 kPa under 25 years to 3.4 kPa over 55

Study: Primary human physiology study (transient-elastography liver stiffness, rigorously screened healthy volunteers)

Population: 2,528 healthy volunteers recruited from the general population and the Red Cross Transfusion Center in Hong Kong, all with questionnaire, anthropometry, fasting blood tests, abdominal ultrasound and transient elastography; 1,998 were excluded (abnormal ultrasound, chronic medical conditions, abnormal blood tests, high BMI, high blood pressure or invalid scans), leaving 530 without known liver disease.

Summary: Rigorously screened Hong Kong cohort (Fung 2013): reference range 2.3–5.9 kPa (mean 4.1 ± 0.89) in the 530 volunteers retained from 2,528 after exclusions; median stiffness fell with age, 4.2 kPa under 25 years to 3.4 kPa over 55

Result: The reference range in the 530 retained subjects was 2.3 to 5.9 kPa (mean 4.1, SD 0.89). Median stiffness was higher in men than women (4.3 vs 4.0 kPa, P < 0.001) and declined with age, from a median of 4.2 kPa in those under 25 years to 3.4 kPa in those over 55 years (P = 0.001).

Watch out: The tightest ceiling on this shelf (5.9 kPa) is a product of the screening: four of five recruited volunteers were excluded. It is a screened-healthy range, not a general-population range, and must not be applied to unscreened patients.

Source: Fung J et al. Defining normal liver stiffness range in a normal healthy Chinese population without liver disease. PloS one. 2013. PMID: 24386446. Registry ID: none in the record. MeSH: Adolescent · Adult · Asian People · Elasticity Imaging Techniques · Female · Hong Kong · Humans · Liver · Male · Middle Aged

Card 3 — Healthy living donors, South Korea (Kim 2010): mean 4.6 ± 0.5 kPa with a 5th–95th percentile normal range of 3.9–5.3 kPa in 69 donors — no age or sex effect

Study: Primary human physiology study (transient-elastography liver stiffness, healthy living donors)

Population: 69 healthy living liver and kidney donors in South Korea (mean age 38.9 ± 11.9 years; 35 men, 34 women), none with diabetes, hypertension, hepatitis B or C, heart dysfunction, liver dysfunction or the metabolic syndrome; liver histology was available in 12 liver donors (8 normal, 4 with steatosis under 5%). Measurement failure rate 2.7%.

Summary: Healthy living donors, South Korea (Kim 2010): mean 4.6 ± 0.5 kPa with a 5th–95th percentile normal range of 3.9–5.3 kPa in 69 donors — no age or sex effect

Result: Mean liver stiffness was 4.6 ± 0.5 kPa (range 3.3–5.6 kPa). Values did not differ significantly between men (4.6 ± 0.6 kPa) and women (4.5 ± 0.5 kPa, P = 0.636), nor by age (P = 0.851). The normal range, from the 5th and 95th percentiles, was 3.9 to 5.3 kPa — the narrowest range on this shelf, from its smallest and most selected population.

Watch out: Only 69 donors — transplant-selected, metabolically clean volunteers; the absence of a sex effect here, against clear sex effects in the larger cohorts, is most plausibly a small-sample finding, and the 3.9–5.3 kPa range should not displace the larger cohorts' ranges.

Source: Kim SU et al. What are 'true normal' liver stiffness values using FibroScan?: a prospective study in healthy living liver and kidney donors in South Korea. Liver international : official journal of the International Association for the Study of the Liver. 2010. PMID: 19929903. Registry ID: none in the record. MeSH: Adult · Age Factors · Elasticity Imaging Techniques · Female · Humans · Liver · Living Donors · Male · Middle Aged · Prospective Studies · Reference Values · Republic of Korea · Sex Factors · Tissue Donors · Young Adult

Card 4 — Free-living Indian population cohort (Das 2012): 5th–95th percentile range 3.2–8.5 kPa in 437 healthy adults — both lean (BMI <18.5) and obese healthy subjects were stiffer than normal-BMI subjects

Study: Primary human physiology study (transient-elastography liver stiffness, free-living population cohort)

Population: 437 healthy subjects with normal alanine aminotransferase recruited from a free-living population project (the Birbhum Population Project, a health and demographic surveillance system in India); liver stiffness measured by transient elastography (FibroScan). A separate liver-disease clinic group in the same report is not part of this reference card.

Summary: Free-living Indian population cohort (Das 2012): 5th–95th percentile range 3.2–8.5 kPa in 437 healthy adults — both lean (BMI <18.5) and obese healthy subjects were stiffer than normal-BMI subjects

Result: In healthy subjects, the 5th and 95th percentile values — the study's normal range — were 3.2 and 8.5 kPa. Healthy subjects with a BMI below 18.5 kg/m² had higher stiffness than normal-BMI subjects, comparable to obese subjects (6.05 ± 1.78 vs 5.51 ± 1.59 and 6.60 ± 1.21 kPa respectively). Mean stiffness in the healthy group overall was 5.63 ± 1.64 kPa.

Watch out: The widest 'normal' range on this shelf (to 8.5 kPa) comes from the least-screened population: it describes a free-living population including lean, undernourished subjects, and is a different kind of normal from the screened Hong Kong and donor ranges — never merged with them.

Source: Das K et al. "Normal" liver stiffness measure (LSM) values are higher in both lean and obese individuals: a population-based study from a developing country. Hepatology (Baltimore, Md.). 2012. PMID: 21952989. Registry ID: none in the record. MeSH: Adult · Case-Control Studies · Developing Countries · Elasticity · Elasticity Imaging Techniques · Female · Humans · India · Liver · Liver Cirrhosis · Liver Diseases · Male · Middle Aged · Obesity · ROC Curve · Reference Values

Card 5 — Synthesis: screened-healthy transient-elastography ranges sit at 2.3–5.9 kPa (Hong Kong) and 3.9–5.3 kPa (Korean donors), while general-population values run higher and wider (mean 5.49 kPa in France; 3.2–8.5 kPa in India) — the population screened defines the 'normal'

Study: Synthesis

Population: Synthesis of the four primary datasets carded above.

Summary: Synthesis: screened-healthy transient-elastography ranges sit at 2.3–5.9 kPa (Hong Kong) and 3.9–5.3 kPa (Korean donors), while general-population values run higher and wider (mean 5.49 kPa in France; 3.2–8.5 kPa in India) — the population screened defines the 'normal'

Result: Framed by Guyton & Hall / Boron & Boulpaep (gastrointestinal / hepatic sections; the framing is brief, and this shelf rests chiefly on the primary elastography reference literature). Across four independent populations the pattern is consistent: rigorous screening produces low, tight ranges (Fung 2013: 2.3–5.9 kPa, mean 4.1; Kim 2010: 3.9–5.3 kPa, mean 4.6), while check-up and free-living populations produce higher means and higher ceilings (Roulot 2008: mean 5.49 kPa, metabolic syndrome 6.51 kPa after adjustment; Das 2012: 3.2–8.5 kPa). Sex (men stiffer in the two large cohorts), BMI at both extremes, and the metabolic syndrome all shift values; measurement failure rises steeply with BMI. All values are FibroScan transient-elastography kilopascals. PHYSIOLOGY — ESTABLISHED: four independent datasets agree on the structure — a screened-healthy centre near 4–5 kPa with population definition, sex and metabolic status as the movers — while each population's exact limits stay its own.

Watch out: Never print one population's upper limit as the universal normal ceiling: 5.9 kPa (screened) and 8.5 kPa (free-living) answer different questions, and neither transfers to MR elastography or shear-wave elastography.

Source: Synthesis of the reports carded above; no additional source.