SourceMed · Shelf #7578 in the ask interface

STOP-Bang in surgical patients: sensitivity 85–90% for OSA at low specificity — and no adjusted association with mortality, cardiac complications or stay in 26,068 patients

Shelf #7578 · Emergency & first hours

PREDICTIVE PERFORMANCE — high, severity-graded sensitivity for detecting OSA in surgical patients (pooled 85–90%, specificity only 27–47%) but no adjusted association with postoperative mortality, cardiac complications or length of stay in the largest surgical cohort — a prognostic-accuracy stamp, not a treatment stamp

Stamped: 2026-11-28.

Evidence published: 2008–2022.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In adults attending preoperative clinics and having surgery, how accurately does the STOP-Bang questionnaire detect obstructive sleep apnoea against polysomnography — sensitivity and the probability of severe apnoea at each score — in surgical populations, and does a high score predict postoperative complications, mortality or length of stay?

Balance of the evidence

PREDICTIVE PERFORMANCE — split by limb. As a detector of obstructive sleep apnoea against polysomnography, STOP-Bang is highly sensitive in surgical populations: 83.6%, 92.9% and 100% at AHI cut-offs above 5, 15 and 30 at derivation, and pooled preoperative sensitivities of 85%, 88% and 90% — at specificities of only 47%, 29% and 27%, with the probability of severe OSA in surgical patients rising from 15% at a score of 3 to 65% at 7/8. As a prognostic tool, the largest surgical cohort (26,068 patients) found its strata were NOT associated, after adjustment, with 30-day mortality, cardiac complications or length of stay, even though diagnosed OSA rose from 4% to 44% across strata. No card implies screening changes outcomes.

MeSH: Body Mass Index · Body Size · Female · Humans · Male · Mass Screening/methods · Polysomnography · Sleep Apnea, Obstructive/epidemiology,physiopathology · Surveys and Questionnaires

Cards (5)

Card 1 — Derivation and validation (Chung 2008): adding BMI, age, neck circumference and sex to the STOP questions raised sensitivity to 83.6%, 92.9% and 100% at apnoea–hypopnoea index cut-offs above 5, above 15 and above 30

Study: Derivation and validation study of the STOP and STOP-Bang questionnaires in preoperative patients, against polysomnography

Population: Preoperative patients aged 18 years or older without previously diagnosed obstructive sleep apnoea: the STOP questionnaire was given to 2,467 patients (27.5% classified high-risk), and 211 underwent polysomnography — 34 in a pilot test and 177 in the validation group on which the sensitivities below rest.

Summary: Derivation and validation (Chung 2008): adding BMI, age, neck circumference and sex to the STOP questions raised sensitivity to 83.6%, 92.9% and 100% at apnoea–hypopnoea index cut-offs above 5, above 15 and above 30

Result: The four STOP questions concern snoring, tiredness during daytime, observed apnoea and high blood pressure. STOP alone had sensitivities of 65.6%, 74.3% and 79.5% at apnoea–hypopnoea index cut-offs above 5, above 15 and above 30. Adding body-mass index, age, neck circumference and gender (STOP-Bang) raised sensitivities to 83.6%, 92.9% and 100% at the same cut-offs — sensitivities are cut-off-specific and are never printed as a single number on this shelf.

Watch out: Only 177 of 2,467 questionnaire respondents contributed validation polysomnography — a selected validation subset, so these sensitivities come from patients who completed sleep studies, not from the whole preoperative clinic.

Source: Chung F et al. STOP questionnaire: a tool to screen patients for obstructive sleep apnea. Anesthesiology. 2008. PMID: 18431116. Registry ID: none in the record. MeSH: Body Mass Index · Body Size · Female · Humans · Male · Mass Screening/methods · Polysomnography · Sleep Apnea, Obstructive/epidemiology,physiopathology · Surveys and Questionnaires

Card 2 — Systematic review and meta-analysis (Nagappa 2015): in surgical patients the probability of severe OSA rose from 15% at a STOP-Bang score of 3 to 25%, 35%, 45% and 65% at scores 4, 5, 6 and 7/8

Study: Systematic review and meta-analysis of STOP-Bang validation studies (17 studies, 9,206 patients)

Population: 17 studies including 9,206 patients in which STOP-Bang was validated against polysomnography, across sleep-clinic and surgical populations.

Summary: Systematic review and meta-analysis (Nagappa 2015): in surgical patients the probability of severe OSA rose from 15% at a STOP-Bang score of 3 to 25%, 35%, 45% and 65% at scores 4, 5, 6 and 7/8

Result: In the sleep-clinic population, sensitivity was 90%, 94% and 96% to detect any OSA (AHI at least 5), moderate-to-severe OSA (AHI at least 15) and severe OSA (AHI at least 30), with corresponding negative predictive values of 46%, 75% and 90%; a similar trend was found in the surgical population. The probability of severe OSA at a STOP-Bang score of 3 was 25% in sleep-clinic patients and 15% in surgical patients, rising stepwise in surgical patients to 25%, 35%, 45% and 65% at scores 4, 5, 6 and 7/8.

Watch out: High sensitivity is bought with low specificity — a score of 3 or more labels many patients high-risk who do not have severe apnoea; the score-by-score probabilities, not the sensitivity alone, are what a preoperative clinic actually uses.

Source: Nagappa M et al. Validation of the STOP-Bang Questionnaire as a Screening Tool for Obstructive Sleep Apnea among Different Populations: A Systematic Review and Meta-Analysis. PloS one. 2015. PMID: 26658438. Registry ID: none in the record. MeSH: Humans · Mass Screening/methods,standards · Polysomnography/methods · Reproducibility of Results · Severity of Illness Index · Sleep Apnea, Obstructive/diagnosis · Surveys and Questionnaires/standards

Card 3 — Preoperative-specific meta-analysis (Hwang 2022): pooled sensitivity 85%, 88% and 90% for any, moderate-to-severe and severe OSA in surgical patients, with specificity of only 47%, 29% and 27%

Study: Systematic review and meta-analysis of STOP-Bang in the preoperative setting (10 studies, 3,247 surgical participants)

Population: 10 studies with 3,247 surgical participants (mean age 57.3 years, mean BMI 32.5 kg/m², 47.4% male), identified from 4,641 articles, in a systematic review and meta-analysis restricted to STOP-Bang as a preoperative screening tool (searches to May 2021, surveillance to October 2021).

Summary: Preoperative-specific meta-analysis (Hwang 2022): pooled sensitivity 85%, 88% and 90% for any, moderate-to-severe and severe OSA in surgical patients, with specificity of only 47%, 29% and 27%

Result: Prevalence of any, moderate-to-severe and severe OSA was 65.2%, 37.7% and 17.0%. Pooled sensitivity of STOP-Bang was 85%, 88% and 90% for the three severity levels, with pooled specificities of 47%, 29% and 27%; areas under the curve were 0.84, 0.67 and 0.63. The authors report a negative predictive value of 93.2% for reasonably excluding severe OSA.

Watch out: The AUC gradient (0.84 for any OSA but 0.63 for severe OSA) sits oddly beside the sensitivity gradient and reflects the included studies' thresholds and spectra — read the severity-specific numbers separately, never as one accuracy figure.

Source: Hwang M et al. Validation of the STOP-Bang questionnaire as a preoperative screening tool for obstructive sleep apnea: a systematic review and meta-analysis. BMC anesthesiology. 2022. PMID: 36451106. Registry ID: CRD42021260451. MeSH: Humans · Male · Adult · Middle Aged · Aged · Female · Sleep Apnea, Obstructive/diagnosis · Research · Databases, Factual · Postoperative Complications · Surveys and Questionnaires

Card 4 — Outcome limb (Sankar 2019): in 26,068 patients having major elective noncardiac surgery, diagnosed OSA rose across STOP-Bang strata (4%, 12%, 44%) — but after adjustment the strata were NOT associated with 30-day mortality, cardiac complications or length of stay

Study: Retrospective cohort validity evaluation in major elective noncardiac surgery (n=26,068) — the postoperative-outcome limb

Population: 26,068 patients undergoing major elective noncardiac surgery at the University Health Network, Toronto (2011–2015), in a retrospective cohort study: 58% were in the low-risk STOP-Bang stratum, 23% intermediate and 19% high.

Summary: Outcome limb (Sankar 2019): in 26,068 patients having major elective noncardiac surgery, diagnosed OSA rose across STOP-Bang strata (4%, 12%, 44%) — but after adjustment the strata were NOT associated with 30-day mortality, cardiac complications or length of stay

Result: The proportion with previously diagnosed OSA was 4% in the low-risk stratum, 12% in the intermediate stratum and 44% in the high-risk stratum — the score does track diagnosed apnoea. Correlations with ASA Physical Status (ρ=0.28), the Revised Cardiac Risk Index (ρ=0.24) and the Charlson Comorbidity Index (ρ=0.10) were weak. After risk adjustment, STOP-Bang risk strata were not associated with 30-day mortality, cardiac complications or length of stay — a null outcome limb, printed on the face beside the accuracy limb.

Watch out: Diagnosed OSA in the record is not polysomnography-confirmed OSA in every patient, and a single health network's elective-surgery cohort may under-represent the emergency and high-risk settings where an outcome association would matter most — but as published, the adjusted outcome association is null.

Source: Sankar A et al. Evaluation of validity of the STOP-BANG questionnaire in major elective noncardiac surgery. British journal of anaesthesia. 2019. PMID: 30686311. Registry ID: none in the record. MeSH: Aged · Cohort Studies · Comorbidity · Cross-Sectional Studies · Elective Surgical Procedures/methods,mortality · Female · Heart Diseases/epidemiology · Humans · Length of Stay · Male · Middle Aged · Postoperative Complications/epidemiology · Predictive Value of Tests · Reproducibility of Results · Retrospective Studies · Risk Assessment · Risk Factors · Sleep Apnea, Obstructive/complications,diagnosis · Surveys and Questionnaires

Card 5 — Synthesis: STOP-Bang detects apnoea in surgical patients with high, severity-graded sensitivity (83.6–100% at derivation; pooled 85–90% preoperatively) at low specificity — yet the largest surgical cohort found no adjusted association between its strata and mortality, cardiac complications or length of stay

Study: Synthesis

Population: All reports carded on this shelf: the derivation/validation study (polysomnography in 177), two meta-analyses (9,206 and 3,247 patients) and the Toronto outcome cohort (26,068 patients).

Summary: Synthesis: STOP-Bang detects apnoea in surgical patients with high, severity-graded sensitivity (83.6–100% at derivation; pooled 85–90% preoperatively) at low specificity — yet the largest surgical cohort found no adjusted association between its strata and mortality, cardiac complications or length of stay

Result: The accuracy limb and the outcome limb point in different directions, and both stay on the face. As a detector, STOP-Bang is sensitive and score-graded: in surgical patients the probability of severe OSA rises from 15% at a score of 3 to 65% at 7/8. As a prognostic tool in the largest surgical cohort, its strata carried no adjusted association with 30-day mortality, cardiac complications or length of stay. This is a prognostic-accuracy shelf: no card implies that screening, or any treatment triggered by screening, changes postoperative outcomes. The distribution of the apnoea–hypopnoea index itself in unselected adults is a different question, homed at pack #7176.

Watch out: See the individual cards; this synthesis adds no new data.

Source: Synthesis of the reports carded above; no additional source.

Estimate type: adjusted estimate, as stated in the card.