Renin and aldosterone reference intervals: six healthy-population datasets — intervals belong to their assay (RIA reads aldosterone 59% higher than LC-MS/MS), sex and age; healthy ratio limits 14.2–25.5

Shelf #7582 · Diabetes, glucose & metabolism

PHYSIOLOGY — ESTABLISHED — six independent healthy-population datasets across four assay approaches consistently establish that plasma renin and aldosterone reference intervals are assay-, sex- and age-specific (including a 59% radioimmunoassay-versus-LC-MS/MS aldosterone bias in plasma), even though each interval belongs to its own method and population and several datasets' numeric limits are not printed in their fetched records

Stamped: 2026-11-28.

Evidence published: 2010–2025.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In healthy adults, what are the reference intervals for plasma renin (activity and direct concentration) and plasma aldosterone concentration — the central 95% ranges by age, sex, assay method (radioimmunoassay, chemiluminescence immunoassay, LC-MS/MS) and population — how far do method-specific intervals sit from one another, what sampling influences (including posture) are recognised, and what upper limit for the aldosterone-to-renin ratio follows from healthy-population distributions rather than from hypertensive referral cohorts?

Balance of the evidence

Textbook framing: Guyton & Hall, adrenal / renin–angiotensin–aldosterone sections, and Boron & Boulpaep, adrenal gland chapter — the framing is brief, and this shelf rests chiefly on the primary reference-interval literature, and says so. Six independent healthy-population datasets (1,347 German population-based subjects; 328 Chinese Han chemiluminescence subjects; 282 Belgian LC-MS/MS volunteers, aldosterone limb only; 170 Hong Kong normotensive volunteers; 309 northern Chinese Han volunteers; 5,200 rigorously screened Yunnan individuals) agree on the structure: intervals are specific to assay, sex and age band, renin activity and direct renin concentration are different measurements with different intervals, and healthy-population aldosterone-to-renin ratio upper limits (14.2–25.5 by sex and age) sit clearly below hypertensive-referral cut-offs. The single most important number is a bias: radioimmunoassay reads plasma aldosterone on average 59% higher than LC-MS/MS. Intervals are never merged across methods on this shelf. PHYSIOLOGY — ESTABLISHED.

MeSH: Adult · Aged · Aldosterone/blood,standards · Cohort Studies · Diagnostic Techniques, Endocrine/standards · Female · Germany · Health · Humans · Longitudinal Studies · Male · Middle Aged · Population · Reference Values · Renin/blood,standards · Young Adult

Cards (7)

Card 1 — Population-based intervals, north-east Germany (Hannemann 2010; SHIP-1): upper aldosterone-to-renin ratio limits of 14.2 and 20.3 (younger) and 22.4 and 25.5 (older) in men and women — clearly below referral-cohort cut-offs

Study: Primary human physiology dataset 1 of 6 (population-based reference intervals, radioimmunometric assay, Germany)

Population: Reference population of 1,347 healthy subjects selected from 3,300 participants in the first follow-up of the population-based Study of Health in Pomerania (SHIP-1), north-east Germany; plasma aldosterone and renin concentration measured by radioimmunometric procedures. Reference intervals are the central 95% range (2.5th to 97.5th percentiles), presented by sex and age band (25–54 and 55–74 years). The fetched record does not print the numeric aldosterone or renin interval limits themselves, so none are claimed for those analytes on this card.

Summary: Population-based intervals, north-east Germany (Hannemann 2010; SHIP-1): upper aldosterone-to-renin ratio limits of 14.2 and 20.3 (younger) and 22.4 and 25.5 (older) in men and women — clearly below referral-cohort cut-offs

Result: The upper reference limit for the aldosterone-to-renin ratio was 14.2 in younger men and 20.3 in younger women, and 22.4 in older men and 25.5 in older women — clearly lower than previously reported values from hypertensive patients in primary care or hypertension referral centres. Time of blood sampling had no influence on the ratio, while beta blockers and agents acting on the renin–angiotensin system were associated with higher and lower ratios respectively; aldosterone and renin were also associated with sex, age and estrogen intake.

Watch out: Radioimmunometric-era intervals from one German region: the ratio limits are this assay's and this population's, and the medication associations mean a 'healthy-population' interval still shifts with common antihypertensive drugs.

Source: Hannemann A et al. Reference intervals for aldosterone, renin, and the aldosterone-to-renin ratio in the population-based Study of Health in Pomerania (SHIP-1). Hormone and metabolic research = Hormon- und Stoffwechselforschung = Hormones et metabolisme. 2010. PMID: 20157876. Registry ID: none in the record. MeSH: Adult · Aged · Aldosterone/blood,standards · Cohort Studies · Diagnostic Techniques, Endocrine/standards · Female · Germany · Health · Humans · Longitudinal Studies · Male · Middle Aged · Population · Reference Values · Renin/blood,standards · Young Adult

Card 2 — Chinese Han chemiluminescence intervals (Deng 2018): men — aldosterone 76–722 pmol/L (about 2.7–26.0 ng/dL), direct renin 3.3–92.7 mIU/L; women — aldosterone 85–1,010 pmol/L (about 3.1–36.4 ng/dL), renin 3.7–99.8 mIU/L

Study: Primary human physiology dataset 2 of 6 (chemiluminescence reference intervals, Chinese Han population)

Population: 328 healthy Chinese Han individuals, with plasma aldosterone and direct renin concentration measured on a fully automated chemiluminescence analyser (DiaSorin LIAISON XL); within-laboratory imprecision was 5.6–6.7% for aldosterone and 3.0–3.3% for renin, and the limits of quantitation were 72.2 pmol/L and 1.27 mIU/L respectively.

Summary: Chinese Han chemiluminescence intervals (Deng 2018): men — aldosterone 76–722 pmol/L (about 2.7–26.0 ng/dL), direct renin 3.3–92.7 mIU/L; women — aldosterone 85–1,010 pmol/L (about 3.1–36.4 ng/dL), renin 3.7–99.8 mIU/L

Result: Central 95% reference intervals for men: aldosterone 76–722 pmol/L (about 2.7–26.0 ng/dL in US units), direct renin 3.3–92.7 mIU/L, aldosterone-to-renin ratio 2.2–46.0 pmol/mIU. For women: aldosterone 85–1,010 pmol/L (about 3.1–36.4 ng/dL), renin 3.7–99.8 mIU/L, ratio 3.6–68.4 pmol/mIU. Upper ratio limits for younger and older men were lower than for women, and the authors recommend sex- and age-specific intervals. The chemiluminescence ratio and the radioimmunoassay (activity-based) ratio showed almost perfect agreement for primary-aldosteronism screening in their comparison set (kappa 0.815).

Watch out: Direct renin concentration (mIU/L) is not plasma renin activity — intervals for the two renin measures are not interchangeable, and this dataset's ratio units (pmol/mIU) differ from activity-based ratios elsewhere on this shelf.

Source: Deng L et al. Analytical validation and investigation on reference intervals of aldosterone and renin in Chinese Han population by using fully automated chemiluminescence immunoassays. Clinical biochemistry. 2018. PMID: 29684370. Registry ID: none in the record. MeSH: Adult · Age Factors · Aged · Aldosterone/blood · Asian People · Automation, Laboratory · Biomarkers/blood · China · Cohort Studies · Female · Humans · Hyperaldosteronism/blood,diagnosis,ethnology · Hypertension/blood,diagnosis,ethnology · Immunoassay · Limit of Detection · Luminescent Measurements · Male · Middle Aged · Renin/blood · Reproducibility of Results · Sensitivity and Specificity · Sex Characteristics · Young Adult

Card 3 — Belgian LC-MS/MS aldosterone intervals (Le Goff 2018 — aldosterone limb only): women 0.07–0.73 nmol/L (about 2.5–26.3 ng/dL), men 0.04–0.41 nmol/L (about 1.4–14.8 ng/dL) — and radioimmunoassay read on average 59% higher than LC-MS/MS in plasma

Study: Primary human physiology dataset 3 of 6 (LC-MS/MS plasma and urine aldosterone intervals, Belgium — aldosterone limb only, no renin interval)

Population: 282 healthy Belgian Caucasian volunteers (114 men, mean age 35 years; 168 women, mean age 42 years) for the plasma reference-interval study, with a subset of 139 providing 24-hour urine collections; a laboratory-developed LC-MS/MS method was validated against the existing radioimmunoassay (RIA), with 68 plasma and 23 urine samples in the method comparison. This record carries no MeSH terms (see source line).

Summary: Belgian LC-MS/MS aldosterone intervals (Le Goff 2018 — aldosterone limb only): women 0.07–0.73 nmol/L (about 2.5–26.3 ng/dL), men 0.04–0.41 nmol/L (about 1.4–14.8 ng/dL) — and radioimmunoassay read on average 59% higher than LC-MS/MS in plasma

Result: The proposed LC-MS/MS reference interval for plasma aldosterone is 0.07–0.73 nmol/L in women (about 2.5–26.3 ng/dL in US units) and 0.04–0.41 nmol/L in men (about 1.4–14.8 ng/dL); the urinary aldosterone reference interval was below 60.94 nmol/day, with no sex difference. Regression comparison showed RIA results on average 59% higher than LC-MS/MS in plasma and 11% higher in urine — the assay bias is itself a card-level finding: an RIA-era interval cannot be applied to an LC-MS/MS result.

Watch out: An aldosterone-only limb: this dataset contributes no renin interval, and its volunteers were younger (means 35 and 42 years) than several other datasets on this shelf.

Source: Le Goff CM et al. Migration from RIA to LC-MS/MS for aldosterone determination: Implications for clinical practice and determination of plasma and urine reference range intervals in a cohort of healthy Belgian subjects. Clinical mass spectrometry (Del Mar, Calif.). 2018. PMID: 39193352. Registry ID: none in the record. MeSH: none in the record

Card 4 — Hong Kong LC-MS/MS intervals (Cheng 2022): age-specific renin-activity and aldosterone intervals from 170 normotensive volunteers — a renin-activity difference below versus above age 45, and no sex difference

Study: Primary human physiology dataset 4 of 6 (LC-MS/MS normotensive reference intervals, Hong Kong — renin activity, not direct renin concentration)

Population: 170 normotensive healthy volunteers recruited to establish the normotensive reference intervals for plasma renin activity and plasma aldosterone concentration by LC-MS/MS in a Hong Kong teaching-hospital laboratory. A further 362 essential-hypertensive patients were also analysed in the same report; that hypertensive limb is NOT a healthy-population dataset and is not counted among this shelf's six. The fetched record does not print the numeric interval limits, so none are claimed here.

Summary: Hong Kong LC-MS/MS intervals (Cheng 2022): age-specific renin-activity and aldosterone intervals from 170 normotensive volunteers — a renin-activity difference below versus above age 45, and no sex difference

Result: There was no sex-specific difference in renin activity or aldosterone for normotensive (or hypertensive) reference subjects. Differences in both analytes were noted between normotensive subjects aged below 45 and their older counterparts, so age-specific central 95% reference intervals were established accordingly; in the hypertensive group the age difference held for renin activity but not aldosterone.

Watch out: Renin ACTIVITY intervals (this card) and direct renin CONCENTRATION intervals (the chemiluminescence and Pomerania cards) measure different things and their limits must never be interchanged; the absence of a sex difference here, against sex partitioning in other datasets, is itself part of the cross-population picture.

Source: Cheng JY et al. Chinese normotensive and essential hypertensive reference intervals for plasma aldosterone and renin activity by liquid chromatography-tandem mass spectrometry. Clinical chemistry and laboratory medicine. 2022. PMID: 35922153. Registry ID: none in the record. MeSH: Aged · Aldosterone · Blood Pressure · China · Chromatography, Liquid · Humans · Hypertension · Renin · Tandem Mass Spectrometry

Card 5 — Northern Chinese Han LC-MS/MS intervals (Yin 2023): intervals for renin activity, aldosterone, angiotensin II and 24-hour urinary aldosterone in 309 healthy volunteers — aldosterone partitioned by sex, angiotensin II by region, urinary aldosterone by urine potassium

Study: Primary human physiology dataset 5 of 6 (LC-MS/MS multi-analyte reference intervals, northern Chinese Han population)

Population: 309 healthy volunteers recruited in three northern-Chinese cities, with plasma renin activity, aldosterone and angiotensin II and 24-hour urinary aldosterone all measured by a laboratory-developed LC-MS/MS method whose performance was verified in the report. The fetched record does not print the numeric interval limits, so none are claimed here.

Summary: Northern Chinese Han LC-MS/MS intervals (Yin 2023): intervals for renin activity, aldosterone, angiotensin II and 24-hour urinary aldosterone in 309 healthy volunteers — aldosterone partitioned by sex, angiotensin II by region, urinary aldosterone by urine potassium

Result: Variance-component analysis showed the aldosterone interval must be partitioned by sex (standard deviation ratio 0.466), the angiotensin II interval by region (0.407), and the 24-hour urinary aldosterone interval by urine potassium (0.579); reference intervals were then determined by the nonparametric percentile method for each analyte. The partitioning structure — which factor splits which analyte — is this dataset's cardable product.

Watch out: Three cities pooled with a region partition for one analyte only: a single 'northern Chinese' interval hides the region effect the authors themselves found for angiotensin II.

Source: Yin Y et al. Reference intervals for LC-MS /MS measurements of plasma renin activity, aldosterone, angiotensin II, and 24-hour urinary aldosterone in Northern Chinese Han population. Clinica chimica acta; international journal of clinical chemistry. 2023. PMID: 37003517. Registry ID: none in the record. MeSH: Humans · Aldosterone/blood,urine · Angiotensin II/blood · Chromatography, Liquid · East Asian People · Hyperaldosteronism · Hypertension · Peptide Hormones · Renin/blood · Tandem Mass Spectrometry/methods · Reference Values · Healthy Volunteers · Renin-Angiotensin System

Card 6 — Yunnan intervals (Zhang 2025): 5,200 rigorously screened healthy individuals — renin concentration lower in women and falling with age; aldosterone higher in men, lowest at 18–24 years and peaking at 25–64

Study: Primary human physiology dataset 6 of 6 (age- and sex-specific renin and aldosterone intervals, Yunnan, China)

Population: Cross-sectional survey in Yunnan Province, China (multi-stage stratified sampling across four districts/counties, urban and rural): 9,129 ostensibly healthy individuals formed the initial sample, and after exclusions (pregnancy, lactation, contraceptive use, hypertension, hypokalaemia, renal insufficiency, obesity and diagnosed disease) 5,200 individuals were successfully included for age- and sex-specific reference intervals for plasma renin concentration and plasma aldosterone concentration. The fetched record does not print the numeric interval limits, so none are claimed here. The report's background lists body posture among the factors known to influence renin and aldosterone measurement.

Summary: Yunnan intervals (Zhang 2025): 5,200 rigorously screened healthy individuals — renin concentration lower in women and falling with age; aldosterone higher in men, lowest at 18–24 years and peaking at 25–64

Result: Renin and aldosterone levels differed significantly across sex and age groups: plasma renin concentration was significantly lower in women than men and decreased with age, while plasma aldosterone concentration was significantly higher in men than women, lowest in the 18–24 age group and peaking in the 25–64 age group. Age- and sex-specific reference intervals were established within the redefined groups — the largest single dataset on this shelf, and the one whose screening rigour (5,200 retained from 9,129) defines what 'healthy' means for its intervals.

Watch out: The strict exclusions (including obesity and any hypertension) make this a super-healthy reference population; its intervals will sit differently from a general-population sample such as SHIP-1's, and the two sampling frames must not be averaged.

Source: Zhang C et al. Age- and sex-specific reference intervals for renin and aldosterone in healthy individuals in Yunnan Province, China. Journal of human hypertension. 2025. PMID: 40670656. Registry ID: none in the record. MeSH: Humans · Renin/blood · Female · Male · Middle Aged · Adult · China · Aldosterone/blood · Cross-Sectional Studies · Reference Values · Age Factors · Young Adult · Sex Factors · Aged · Adolescent · Biomarkers/blood

Card 7 — Synthesis: six independent healthy-population datasets agree that renin and aldosterone reference intervals are assay-, sex- and age-specific and must never be merged across methods — radioimmunoassay reads aldosterone on average 59% higher than LC-MS/MS in plasma, and healthy-population aldosterone-to-renin ratio limits sit well below hypertensive-referral cut-offs

Study: Synthesis

Population: Synthesis of the six primary datasets carded above (1,347; 328; 282; 170; 309; and 5,200 healthy subjects).

Summary: Synthesis: six independent healthy-population datasets agree that renin and aldosterone reference intervals are assay-, sex- and age-specific and must never be merged across methods — radioimmunoassay reads aldosterone on average 59% higher than LC-MS/MS in plasma, and healthy-population aldosterone-to-renin ratio limits sit well below hypertensive-referral cut-offs

Result: Textbook framing: Guyton & Hall (adrenal / renin–angiotensin–aldosterone sections) and Boron & Boulpaep (adrenal gland chapter) — the framing is brief, and this shelf rests chiefly on the primary reference-interval literature, and says so. Across six populations and four measurement approaches (radioimmunometric, chemiluminescence, and LC-MS/MS for both renin activity and direct renin concentration), the consistent findings are structural: intervals partition by sex (chemiluminescence aldosterone 76–722 pmol/L, about 2.7–26.0 ng/dL, in men versus 85–1,010 pmol/L, about 3.1–36.4 ng/dL, in women; LC-MS/MS aldosterone 0.04–0.41 nmol/L in Belgian men versus 0.07–0.73 nmol/L in women) and by age (a renin-activity split at 45 years in Hong Kong; renin falling with age in Yunnan's 5,200), and they belong to their assay — RIA reads 59% higher than LC-MS/MS in plasma. Healthy-population upper limits for the aldosterone-to-renin ratio (14.2–25.5 by sex and age in SHIP-1) sit clearly below referral-cohort cut-offs. No dataset carded here prints a posture-partitioned interval in its fetched record, so posture is carried as a recognised influence on sampling (named in the Yunnan report's background), not as a carded interval. Aldosterone secretion rate by isotope dilution (pack #6964) and the ratio's diagnostic accuracy in primary-aldosteronism screening (pack #6062) are different measurements and questions — cross-points only, never re-carded here.

Watch out: Never apply one method's interval to another method's result, and never interchange renin activity with direct renin concentration; several datasets' numeric limits are not printed in their fetched records and are claimed nowhere on this shelf.

Source: Synthesis of the reports carded above; no additional source.