Shelf #7614 · Critical care & sepsis

PREDICTIVE PERFORMANCE — the rapid shallow breathing index (f/VT) at the classic <105 threshold has moderate pooled sensitivity (0.83) and poor pooled specificity (0.58) for extubation success across 48 studies and 10,946 patients, down from the founding study's sensitivity 0.97 in 100 patients; thresholds <80 and 80–105 perform similarly, so 105 is a permissive criterion, not a stand-alone pass–fail extubation rule

Stamped: 2026-11-28.

Evidence published: 1991–2022.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In mechanically ventilated adults being assessed for liberation from the ventilator, how accurately does the rapid shallow breathing index (RSBI — respiratory frequency divided by tidal volume, f/VT) predict successful weaning and extubation, what does the classic threshold of 105 breaths/min/L actually deliver in sensitivity and specificity on modern pooled evidence, and how far does the threshold (105 vs 80 vs 65, and the measurement conditions) move the answer?

Balance of the evidence

PREDICTIVE PERFORMANCE — a founding near-perfect result settling to moderate sensitivity and poor specificity. The rapid shallow breathing index (f/VT) began with sensitivity 0.97 and the largest ROC area (0.89) among weaning indexes in Yang & Tobin's 100-patient founding study. On modern pooled evidence — 48 studies, 10,946 patients — RSBI <105 breaths/min/L has sensitivity 0.83 (95% CI 0.78 to 0.87) and specificity only 0.58 (95% CI 0.49 to 0.66) for extubation success, with thresholds <80 and 80–105 performing similarly; the 2001 evidence review already showed the asymmetry (positive likelihood ratios ≤2.23; negative 0.09 to 0.23). The index is permissive / rule-out-flavoured, not a pass–fail extubation rule, and no card implies acting on it improves outcomes.

MeSH: Arteries · Female · Humans · Male · Middle Aged · Oxygen · Partial Pressure · Prognosis · Prospective Studies · Respiration · Sensitivity and Specificity · Thorax · Tidal Volume · Ventilator Weaning · APACHE · Coronary Care Units · Postoperative Care · Predictive Value of Tests · Pulmonary Disease, Chronic Obstructive · Respiration, Artificial · Treatment Outcome · Airway Extubation · Clinical Decision Rules · Clinical Decision-Making · Respiratory Rate

Cards (4)

Card 1 — Founding study (Yang & Tobin 1991): f/VT derived in 36 patients and tested prospectively in 64 — largest ROC area of the indexes tested (0.89), sensitivity 0.97 and specificity 0.64 at its best threshold

Study: Prospective derivation and validation cohort (founding RSBI study, 36 + 64 patients)

Population: Mechanically ventilated patients being assessed for weaning: index thresholds were derived in 36 patients and then tested prospectively in an additional 64 patients; the rapid shallow breathing index (f/VT, respiratory frequency divided by tidal volume) was compared with minute ventilation, maximal inspiratory pressure and the CROP index.

Summary: Founding study (Yang & Tobin 1991): f/VT derived in 36 patients and tested prospectively in 64 — largest ROC area of the indexes tested (0.89), sensitivity 0.97 and specificity 0.64 at its best threshold

Result: Sensitivity was highest for maximal inspiratory pressure (1.00), followed closely by f/VT (0.97); specificity was highest for f/VT (0.64) and lowest for maximal inspiratory pressure (0.11). The area under the ROC curve for f/VT (0.89) was larger than for CROP (0.78; P < 0.05), maximal inspiratory pressure (0.61; P < 0.001) and minute ventilation (0.40; P < 0.001). The authors concluded rapid shallow breathing was the most accurate predictor of weaning failure, and its absence the most accurate predictor of success.

Watch out: A founding result from 100 patients in total at one centre in 1991: the near-perfect sensitivity of 0.97 is the derivation-era figure, and the pooled modern estimate on the next cards is materially lower — both ends of that arc are the content of this shelf.

Source: Yang KL et al. A prospective study of indexes predicting the outcome of trials of weaning from mechanical ventilation. The New England journal of medicine. 1991. PMID: 2023603. Registry ID: none in the record. MeSH: Arteries · Female · Humans · Male · Middle Aged · Oxygen · Partial Pressure · Prognosis · Prospective Studies · Respiration · Sensitivity and Specificity · Thorax · Tidal Volume · Ventilator Weaning

Card 2 — Evidence-based weaning review (65 observational studies, 70 publications): pooled positive likelihood ratios for RSBI were limited (highest 2.23) while negative results carried substantial weight (likelihood ratios 0.09 to 0.23)

Study: Systematic evidence review of weaning predictors (65 observational studies)

Population: 65 observational studies of weaning predictors reported in 70 publications, grouped across heterogeneous populations, COPD patients and cardiovascular ICU patients; predictors for stepwise reduction of support, trials of unassisted breathing, and successful extubation were assessed separately.

Summary: Evidence-based weaning review (65 observational studies, 70 publications): pooled positive likelihood ratios for RSBI were limited (highest 2.23) while negative results carried substantial weight (likelihood ratios 0.09 to 0.23)

Result: For trials of unassisted breathing, pooled results for the power of a positive RSBI result were limited (highest likelihood ratio 2.23), while the power of a negative result was substantial (likelihood ratios 0.09 to 0.23). For prediction of successful extubation, an RSBI <100 or 105 breaths/min/L had sensitivity ranging 65 to 96% and specificity 0 to 73% across studies. Judged by ROC areas, no variable showed more than modest accuracy for weaning outcome; the authors note clinicians had already considered these results when choosing patients for weaning trials, which may itself depress measured accuracy.

Watch out: A 2001 review of small, heterogeneous observational studies with widely varying thresholds and measurement conditions; its likelihood-ratio framing — a negative (low) RSBI helps, a positive one barely moves probability — is not interchangeable with a single sensitivity / specificity pair.

Source: Meade M et al. Predicting success in weaning from mechanical ventilation. Chest. 2001. PMID: 11742961. Registry ID: none in the record. MeSH: APACHE · Coronary Care Units · Humans · Postoperative Care · Predictive Value of Tests · Pulmonary Disease, Chronic Obstructive · Respiration, Artificial · Treatment Outcome · Ventilator Weaning

Card 3 — Modern pooled estimate (48 studies, 10,946 patients): RSBI <105 gives sensitivity 0.83 and specificity 0.58 for extubation success; thresholds <80 and 80–105 perform similarly

Study: Systematic review and meta-analysis of RSBI diagnostic accuracy (48 studies, 10,946 patients)

Population: 48 studies involving RSBI measurements in 10,946 mechanically ventilated patients, searched to September 2019, with study data extracted and quality assessed independently and in duplicate; subgroup analyses covered differing patient characteristics and operational differences in RSBI measurement.

Summary: Modern pooled estimate (48 studies, 10,946 patients): RSBI <105 gives sensitivity 0.83 and specificity 0.58 for extubation success; thresholds <80 and 80–105 perform similarly

Result: Pooled sensitivity for RSBI <105 breaths/min/L predicting extubation success was moderate at 0.83 (95% CI 0.78 to 0.87; moderate certainty) whereas specificity was poor at 0.58 (95% CI 0.49 to 0.66; moderate certainty), with a diagnostic odds ratio of 5.91 (95% CI 4.09 to 8.52). RSBI thresholds of <80 or 80 to 105 yielded similar sensitivity, specificity and diagnostic odds ratios, consistently across subgroup analyses. The authors conclude the RSBI as a stand-alone test has moderate sensitivity and poor specificity, and propose studying it as a permissive criterion for a spontaneous breathing trial in patients at intermediate pretest probability.

Watch out: The classic threshold of 105 is not a pass–fail extubation rule on this evidence: specificity of 0.58 means many patients below the threshold still fail, and similar performance at <80 shows the exact cut-off matters less than the founding literature implied. Measurement conditions (ventilator vs disconnected, timing relative to the breathing trial) vary across the pooled studies.

Source: Trivedi V et al. The Usefulness of the Rapid Shallow Breathing Index in Predicting Successful Extubation: A Systematic Review and Meta-analysis. Chest. 2022. PMID: 34181953. Registry ID: PROSPERO CRD42020149196. MeSH: Airway Extubation · Clinical Decision Rules · Clinical Decision-Making · Humans · Respiration, Artificial · Respiratory Rate · Tidal Volume · Ventilator Weaning

Card 4 — Synthesis: the founding sensitivity of 0.97 (100 patients, 1991) settles to pooled sensitivity 0.83 and poor specificity 0.58 at <105 on 10,946 patients — the RSBI is a permissive, rule-out-flavoured index, not a stand-alone extubation rule

Study: Synthesis

Population: All reports carded on this shelf.

Summary: Synthesis: the founding sensitivity of 0.97 (100 patients, 1991) settles to pooled sensitivity 0.83 and poor specificity 0.58 at <105 on 10,946 patients — the RSBI is a permissive, rule-out-flavoured index, not a stand-alone extubation rule

Result: The arc is the finding. Yang & Tobin's founding prospective study gave f/VT the largest ROC area (0.89) with sensitivity 0.97 and specificity 0.64; the 2001 evidence review found positive results weak (likelihood ratios up to 2.23) and negative results substantial (0.09 to 0.23); and the 2022 meta-analysis of 48 studies and 10,946 patients gives RSBI <105 a pooled sensitivity of 0.83 (95% CI 0.78 to 0.87) and specificity of 0.58 (95% CI 0.49 to 0.66), with thresholds <80 and 80–105 performing similarly. No card on this shelf shows that acting on the RSBI improves outcomes — this is a prognostic-accuracy shelf. Cross-point only: diaphragm-ultrasound weaning prediction (including diaphragmatic RSBI variants) and spontaneous-breathing-trial method shelves ask different questions and share no PMID with this shelf.

Watch out: See the individual cards for each report's limits; this synthesis adds no new data.

Source: Synthesis of the reports carded above; no additional source.