SourceMed · Shelf #7616 in the ask interface

4AT for delirium: pooled sensitivity 0.88 / specificity 0.88 on 2 anchors + 1 supporting validation — ROC 0.89 even with dementia, weaker in severe cognitive impairment

Shelf #7616 · Geriatrics, frailty & deprescribing

PREDICTIVE PERFORMANCE — the 4AT detects delirium in hospitalised older adults with pooled sensitivity 0.88 and specificity 0.88 (17 studies, 3,702 observations; founding validation ROC 0.93, 0.89 with dementia), on a stated base of 2 anchors + 1 verified supporting validation (3 reports in total), with the supporting Swedish validation weaker (sensitivity 0.70) in severe cognitive impairment — a diagnostic-accuracy finding, not evidence that detection improves outcomes

Stamped: 2026-11-28.

Evidence published: 2014–2021.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In hospitalised older adults on wards, in the emergency department and after surgery, how accurately does the 4AT (the 4 'A's Test — alertness, AMT-4, attention, acute change or fluctuating course) detect delirium against a reference standard, how does it perform in patients with dementia and after stroke, and how long does it take at the bedside?

Balance of the evidence

PREDICTIVE PERFORMANCE — good pooled accuracy on a stated base of 2 anchors + 1 verified supporting validation (3 reports in total). The founding validation (236 patients aged ≥70) gave sensitivity 89.7%, specificity 84.1% and ROC area 0.93 — 0.89 in patients with dementia, the population where the test is hardest. The anchor meta-analysis (17 studies, 3,702 observations) pooled sensitivity 0.88 and specificity 0.88 at 24.2% prevalence (ex-stroke 0.86 / 0.89). The one supporting independent validation (Swedish, 200 patients) was weaker — sensitivity 0.70, specificity 0.92, AUROC 0.808, worst on the severe-cognitive-impairment ward. The test takes under 2 minutes. No card implies detection improves outcomes.

MeSH: Aged · Aged, 80 and over · Delirium · Female · Geriatric Assessment · Humans · Inpatients · Male · Mass Screening · Outcome Assessment, Health Care · Prospective Studies · ROC Curve · Sensitivity and Specificity · Surveys and Questionnaires · Emergency Service, Hospital · Reproducibility of Results · Sweden

Cards (4)

Card 1 — Founding validation (Bellelli 2014): 236 patients aged ≥70 on a geriatrics ward and in rehabilitation — sensitivity 89.7%, specificity 84.1%, ROC area 0.93 overall, 0.92 without dementia and 0.89 with dementia

Study: Prospective validation study (founding 4AT study, 236 patients aged ≥70)

Population: 236 consecutively admitted patients aged ≥70 years (mean 83.9 ± 6.1 years; 64% women) on an acute geriatrics ward and in a rehabilitation department over 4 months; the 4AT was given by a geriatrician within 24 h of admission and the DSM-IV-TR reference diagnosis within 30 min by a different, blinded geriatrician; delirium in 12.3% (29 patients), dementia in 31.2% (74) and both in 7.2% (17). (The fetched record's article title says 234 hospitalised older people; its abstract reports 236 patients studied — the abstract's number is used here.)

Summary: Founding validation (Bellelli 2014): 236 patients aged ≥70 on a geriatrics ward and in rehabilitation — sensitivity 89.7%, specificity 84.1%, ROC area 0.93 overall, 0.92 without dementia and 0.89 with dementia

Result: The 4AT had sensitivity 89.7% and specificity 84.1% for delirium. Areas under the ROC curve were 0.93 in the whole population, 0.92 in patients without dementia and 0.89 in patients with dementia. The authors conclude the 4AT is a sensitive and specific screening method for delirium in hospitalised older people whose brevity and simplicity support routine use.

Watch out: Performance in dementia (ROC area 0.89) is core content, not a caveat — dementia is the commonest reason the test is hard — and the founding setting was geriatrics / rehabilitation with geriatrician assessors, not an undifferentiated emergency department.

Source: Bellelli G et al. Validation of the 4AT, a new instrument for rapid delirium screening: a study in 234 hospitalised older people. Age and ageing. 2014. PMID: 24590568. Registry ID: none in the record. MeSH: Aged · Aged, 80 and over · Delirium · Female · Geriatric Assessment · Humans · Inpatients · Male · Mass Screening · Outcome Assessment, Health Care · Prospective Studies · ROC Curve · Sensitivity and Specificity · Surveys and Questionnaires

Card 2 — Meta-analysis (17 studies, 3,702 observations): pooled sensitivity 0.88 and specificity 0.88 at a delirium prevalence of 24.2%, across acute medicine, surgery, a care home and the emergency department

Study: Systematic review and meta-analysis of 4AT diagnostic accuracy (17 studies, 3,702 observations) — anchor synthesis

Population: 17 diagnostic-accuracy studies (3,702 observations) in older adults (≥65 years) across acute medicine, surgery, a care home and the emergency department, searched to 21 December 2019; 3 studies assessed the 4AT in stroke; methodological quality assessed with QUADAS-2 and rated moderate to good overall; pooled estimates from a bivariate random-effects model.

Summary: Meta-analysis (17 studies, 3,702 observations): pooled sensitivity 0.88 and specificity 0.88 at a delirium prevalence of 24.2%, across acute medicine, surgery, a care home and the emergency department

Result: Overall delirium prevalence was 24.2% (95% CI 17.8 to 32.1%; range 10.5 to 61.9%). Pooled sensitivity was 0.88 (95% CI 0.80 to 0.93) and pooled specificity 0.88 (95% CI 0.82 to 0.92). Excluding the stroke studies, pooled sensitivity was 0.86 (95% CI 0.77 to 0.92) and specificity 0.89 (95% CI 0.83 to 0.93) — the stroke subgroup is thus carded separately in the pooled reading, not merged silently. The 4AT takes under 2 minutes.

Watch out: One of this shelf's two anchors (see the count stated on the synthesis card): a pooled pair across settings with prevalence ranging 10.5–61.9% is an average performance, and the stroke studies pull the pooled estimates, which is why the ex-stroke figures are printed beside them.

Source: Tieges Z et al. Diagnostic accuracy of the 4AT for delirium detection in older adults: systematic review and meta-analysis. Age and ageing. 2021. PMID: 33951145. Registry ID: PROSPERO CRD42019133702. MeSH: Aged · Delirium · Emergency Service, Hospital · Geriatric Assessment · Humans · Mass Screening · Sensitivity and Specificity

Card 3 — Supporting validation — Swedish 4AT (200 patients aged ≥65, two hospitals): sensitivity 0.70, specificity 0.92, AUROC 0.808 vs DSM-IV-TR, with weaker performance on the severe-cognitive-impairment ward

Study: Independent-setting validation study (Swedish 4AT, 200 patients) — supporting report, not an anchor synthesis

Population: 200 patients aged ≥65 years at a university hospital and a county hospital in two Swedish regions, across geriatric stroke/neurology, geriatric multimorbidity, severe cognitive impairment, orthopaedic and urology wards; the translated Swedish 4AT was tested against a DSM-IV-TR reference standard based on the Organic Brain Syndrome scale and patient records, assessed simultaneously and independently by two assessors; applicability was also assessed in the 200 patients and 37 assessors.

Summary: Supporting validation — Swedish 4AT (200 patients aged ≥65, two hospitals): sensitivity 0.70, specificity 0.92, AUROC 0.808 vs DSM-IV-TR, with weaker performance on the severe-cognitive-impairment ward

Result: By the reference standard 18% had delirium and by 4AT 19%; overall percent agreement was 88%, AUROC 0.808, sensitivity 0.70 (95% CI 0.51 to 0.84) and specificity 0.92 (95% CI 0.87 to 0.96). On the severe-cognitive-impairment ward (n = 63) the 4AT was less sensitive and less specific; on the other wards (n = 132) sensitivity was 0.77, specificity 0.93 and AUROC 0.848. Interrater reliability was kappa 0.918; the test took a few minutes, was well tolerated by patients and easy for professionals to use.

Watch out: Labelled as what it is: the one further independent validation beyond the two anchors, in a translated version, with the lowest sensitivity on this shelf (0.70) — concentrated on the severe-cognitive-impairment ward, the population where delirium detection is hardest.

Source: Johansson YA et al. Diagnostic accuracy and clinical applicability of the Swedish version of the 4AT assessment test for delirium detection, in a mixed patient population and setting. BMC geriatrics. 2021. PMID: 34663229. Registry ID: none in the record. MeSH: Aged · Delirium · Geriatric Assessment · Humans · Reproducibility of Results · Sensitivity and Specificity · Sweden

Card 4 — Synthesis: the stated base is 2 anchors + 1 verified supporting validation (3 reports in total) — pooled sensitivity 0.88 / specificity 0.88 across 17 studies, founding ROC 0.93 (0.89 with dementia), and a lower Swedish sensitivity of 0.70 where cognitive impairment was severe

Study: Synthesis

Population: All reports carded on this shelf.

Summary: Synthesis: the stated base is 2 anchors + 1 verified supporting validation (3 reports in total) — pooled sensitivity 0.88 / specificity 0.88 across 17 studies, founding ROC 0.93 (0.89 with dementia), and a lower Swedish sensitivity of 0.70 where cognitive impairment was severe

Result: The count is stated exactly as commissioned: this shelf rests on two anchors — the founding validation (236 patients aged ≥70; sensitivity 89.7%, specificity 84.1%, ROC areas 0.93 overall, 0.92 without dementia, 0.89 with dementia) and the 17-study meta-analysis (3,702 observations; pooled sensitivity 0.88, specificity 0.88; ex-stroke 0.86 / 0.89) — plus one verified supporting validation, the Swedish study (200 patients; sensitivity 0.70, specificity 0.92, AUROC 0.808, weaker on the severe-cognitive-impairment ward). Three reports in total, not an inflated base. The 4AT takes under 2 minutes in the meta-analysis's description. This is a diagnostic-accuracy shelf: no card shows detection improves outcomes. Cross-point only: CAM-ICU (shelf #7615) is the ICU / ventilated-patient instrument; the 4AT requires a conversant patient — no PMID is shared.

Watch out: See the individual cards for each report's limits; this synthesis adds no new data.

Source: Synthesis of the reports carded above; no additional source.