SourceMed · Shelf #7655 in the ask interface

Chromogranin A reference intervals are assay- and sample-type-bound: serum 21.0–108.0 vs plasma 31.0–153.0 ng/mL; second serum interval 30.3–94.4 ng/mL; 44% decay at 48 hours

Shelf #7655 · Heart, vessels, blood pressure & clotting

PHYSIOLOGY — EMERGING — three independent datasets (145 male donors, paired serum/plasma; 120 healthy individuals; 60 + 60 healthy volunteers in an assay evaluation) establish intervals only within assay- and sample-type-specific cells, with a 9.05 cross-assay slope and 44% 48-hour storage decay documented on the face

Stamped: 2026-11-28.

Evidence published: 2014–2019.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In healthy adults, what are the reference intervals for chromogranin A — the central 95% range in serum and in EDTA plasma — how far apart are the intervals given by different assays measuring nominally the same protein, how large are within-person and between-person biological variation, and how fast does the measured value decay in a stored sample?

Balance of the evidence

PHYSIOLOGY — EMERGING, on three independent datasets. Guyton & Hall / Boron & Boulpaep have no chromogranin A reference chapter — this shelf rests on the primary reference literature alone, with the textbooks framing neuroendocrine secretion biology only. The intervals are assay- and sample-type-specific to an unusual degree, and that specificity is the content: in paired samples from 145 healthy male donors, EDTA plasma ran a median 26% higher than serum (reference ranges 31.0–153.0 vs 21.0–108.0 ng/mL, immunoradiometric assay); a second serum dataset (120 healthy individuals) gave 30.3–94.4 ng/mL, with within-person variation 11.9% vs between-person 50.2% and measured values decaying 44% by 48 hours at 4 °C; and an ELISA evaluation found a cross-assay slope of 9.05 against the reference-laboratory method. No interval is printed without its assay and sample type.

MeSH: Adrenal Cortex Neoplasms/blood · Adrenal Gland Neoplasms/blood · Adult · Biomarkers, Tumor/blood · Chromogranin A/blood · Enzyme-Linked Immunosorbent Assay · Humans · Immunoradiometric Assay · Male · Plasma/chemistry · Reference Values · Young Adult · Aged · Artifacts · Blood Chemical Analysis/methods · Fasting · Female · Immunoassay · Middle Aged · Aged, 80 and over · Enzyme-Linked Immunosorbent Assay/methods · Follow-Up Studies · Neuroendocrine Tumors/blood,diagnosis · Reproducibility of Results · Retrospective Studies

Cards (4)

Card 1 — Serum vs EDTA plasma in 145 healthy male blood donors (Glinicki 2015): plasma chromogranin A runs 15–75% higher (median 26%) — separate reference ranges 21.0–108.0 ng/mL (serum) and 31.0–153.0 ng/mL (plasma) by immunoradiometric assay

Study: Primary human physiology study (paired serum / plasma reference ranges, immunoradiometric assay)

Population: 145 healthy male blood donors aged 19–61 years (mean 35.7); paired blood collected into EDTA2K (plasma) and clot-activator (serum) tubes; chromogranin A measured by immunoradiometric kit (CIS bio, France). Men only — printed as such.

Summary: Serum vs EDTA plasma in 145 healthy male blood donors (Glinicki 2015): plasma chromogranin A runs 15–75% higher (median 26%) — separate reference ranges 21.0–108.0 ng/mL (serum) and 31.0–153.0 ng/mL (plasma) by immunoradiometric assay

Result: Median chromogranin A was 42.0 ng/mL in serum (range 16–108) vs 58.0 ng/mL in EDTA plasma (range 23–153); plasma values were 15–75% higher than paired serum values (median difference 26%; P < 0.0001), with a serum–plasma correlation of r = 0.8493. The 2.5th–97.5th percentile reference ranges were 21.0–108.0 ng/mL for serum and 31.0–153.0 ng/mL for plasma. The authors conclude the serum–plasma difference demands separate reference ranges by sample type, and that each laboratory should recommend only one sample material.

Watch out: Men only, one assay: the serum and plasma intervals are not interchangeable, and neither interval transfers to a different assay — see the cross-assay bias card below.

Source: Glinicki P et al. Comparison of chromogranin A (CgA) levels in serum and plasma (EDTA2K) and the respective reference ranges in healthy males. Endokrynologia Polska. 2015. PMID: 25754282. Registry ID: none in the record. MeSH: Adrenal Cortex Neoplasms/blood · Adrenal Gland Neoplasms/blood · Adult · Biomarkers, Tumor/blood · Chromogranin A/blood · Enzyme-Linked Immunosorbent Assay · Humans · Immunoradiometric Assay · Male · Plasma/chemistry · Reference Values · Young Adult

Card 2 — Reference interval and stability in 120 healthy individuals (Pedersen 2014): median 41.2 ng/mL, interval 30.3–94.4 ng/mL — but measured values decayed 15.6% at 24 hours and 44% at 48 hours at 4 °C

Study: Primary human physiology study (reference interval, biological variation and sample stability)

Population: Serum samples from 120 healthy individuals for the reference interval; a separate preanalytical study in 10 healthy subjects sampled at three time points over three days, fasting and non-fasting, with re-measurement after storage at 4 °C.

Summary: Reference interval and stability in 120 healthy individuals (Pedersen 2014): median 41.2 ng/mL, interval 30.3–94.4 ng/mL — but measured values decayed 15.6% at 24 hours and 44% at 48 hours at 4 °C

Result: The median chromogranin A concentration was 41.2 ng/mL with a reference interval of 30.3–94.4 ng/mL (2.5–97.5 percentile). Within-subject biological variation was 11.9% vs between-subject variation of 50.2%; analytical imprecision was 4.3%. Concentrations did not vary with fasting (P = 0.74), sex (P = 0.66) or time of day (P = 0.30). On re-analysis at 4 °C, measured concentrations decayed significantly — a mean decrease of 15.6% after 24 hours and 44% after 48 hours — making sample stability a major preanalytical issue for the assay tested.

Watch out: The storage-decay finding prints beside any interval claim from this shelf: a sample re-measured at 48 hours can read 44% lower, so the interval applies to promptly handled samples on this assay, not to stored ones.

Source: Pedersen L et al. Preanalytical factors of importance for measurement of Chromogranin A. Clinica chimica acta; international journal of clinical chemistry. 2014. PMID: 24804936. Registry ID: none in the record. MeSH: Adult · Aged · Artifacts · Blood Chemical Analysis/methods · Chromogranin A/blood · Fasting · Female · Humans · Immunoassay · Male · Middle Aged · Young Adult

Card 3 — Assay-evaluation dataset (Lim 2019): the CisBio ELISA showed acceptable precision but a large systematic bias against the reference-laboratory assay (slope 9.05) — chromogranin A results are method-specific; preliminary reference study in 60 healthy volunteers in serum and 60 in plasma

Study: Primary human physiology study (assay evaluation with preliminary reference-range study, ELISA)

Population: Analytical evaluation of the CisBio chromogranin A ELISA, including 70 waste serum samples from a clinical laboratory compared with a reference laboratory's proprietary ELISA, paired serum/plasma samples from 24 patients, and a preliminary reference-range study in healthy volunteers (60 in serum, 60 in plasma). The fetched abstract prints no numeric reference-range values from that preliminary study, and this card claims none.

Summary: Assay-evaluation dataset (Lim 2019): the CisBio ELISA showed acceptable precision but a large systematic bias against the reference-laboratory assay (slope 9.05) — chromogranin A results are method-specific; preliminary reference study in 60 healthy volunteers in serum and 60 in plasma

Result: Within-run precision ranged from 3.0% to 5.1% and between-run precision from 4.8% to 12.9%; the limit of blank was 2.4 ng/mL and recovery ranged from 88% to 102%. Against the reference-laboratory assay there was a statistically significant bias: comparison slope 9.05, intercept −18.0, correlation coefficient 0.955. Serum and plasma values correlated well within the CisBio method. The authors conclude analytical performance was acceptable but chromogranin A results are method-specific owing to lack of standardisation and differing antibodies.

Watch out: A slope of 9.05 against another assay is the shelf's central warning: a numeric chromogranin A result — and any interval applied to it — is meaningless without its assay named alongside.

Source: Lim M et al. Evaluation of CisBio ELISA for Chromogranin A Measurement. The journal of applied laboratory medicine. 2019. PMID: 31639703. Registry ID: none in the record. MeSH: Adult · Aged · Aged, 80 and over · Biomarkers, Tumor/blood · Chromogranin A/blood · Enzyme-Linked Immunosorbent Assay/methods · Female · Follow-Up Studies · Humans · Male · Middle Aged · Neuroendocrine Tumors/blood,diagnosis · Reference Values · Reproducibility of Results · Retrospective Studies · Young Adult

Card 4 — Synthesis: chromogranin A intervals are assay- and sample-type-specific to an unusual degree — serum 21.0–108.0 vs plasma 31.0–153.0 ng/mL (immunoradiometric), 30.3–94.4 ng/mL in a second serum dataset, a 9.05 cross-assay slope, and 44% decay by 48 hours

Study: Synthesis

Population: All reports carded on this shelf.

Summary: Synthesis: chromogranin A intervals are assay- and sample-type-specific to an unusual degree — serum 21.0–108.0 vs plasma 31.0–153.0 ng/mL (immunoradiometric), 30.3–94.4 ng/mL in a second serum dataset, a 9.05 cross-assay slope, and 44% decay by 48 hours

Result: Guyton & Hall / Boron & Boulpaep have no chromogranin A reference chapter — this shelf rests on the primary reference literature alone, with the textbooks framing neuroendocrine secretion biology only, and says so. Three independent datasets are carded: 145 healthy male donors with paired serum (median 42.0 ng/mL; range 21.0–108.0) and EDTA-plasma (median 58.0 ng/mL; range 31.0–153.0) intervals by immunoradiometric assay; 120 healthy individuals with a serum interval of 30.3–94.4 ng/mL, within-person variation 11.9% vs between-person 50.2%, and storage decay of 15.6% at 24 hours and 44% at 48 hours at 4 °C; and an ELISA evaluation (60 healthy volunteers per sample type) whose headline result is a cross-assay slope of 9.05. No interval on this shelf may be printed without its assay and sample type. PHYSIOLOGY — EMERGING: the intervals are real within their assay/sample-type cells, but there is no standardisation to unify them, the datasets are modest (60–145 per cell) and one reference study is men only.

Watch out: See the individual cards: sample type, assay and storage time each move the measured value by amounts comparable to the width of the intervals themselves.

Source: Synthesis of the reports carded above; no additional source.