SourceMed · Shelf #7690 in the ask interface
Serum ceruloplasmin reference values: upper limit ~25 mg/dL in men vs ~45 mg/dL in young women (1,706 donors); oral contraceptives raise the mean ~65% (181 vs 110 IU/ml, 1987)
Shelf #7690 · Heart, vessels, blood pressure & clotting
PHYSIOLOGY — EMERGING — serum ceruloplasmin reference values are established as sex-, age- and oestrogen-dependent across four datasets (modern curves in mg/dL: upper reference ~25 mg/dL in men vs ~45 mg/dL in young women; oral contraceptives raised the mean ~65% in IU/ml in 1987), but the datasets span incompatible assay eras and units that are never converted or pooled, three are women-only or women-predominant, and two print no numeric values in their records
Stamped: 2026-11-28.
Evidence published: 1987–2024.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In healthy adults, what are the reference values for serum ceruloplasmin — the central range by sex and age — how large is the sex difference, how strongly do oestrogen exposure (oral contraceptives, pregnancy, lactation) and population move the values, and why do the published datasets report in different units (mg/dL vs IU/ml) that cannot be merged?
Balance of the evidence
Textbook framing: Guyton & Hall and Boron & Boulpaep have no ceruloplasmin reference chapter — this shelf rests on the primary reference literature alone, with the textbooks framing copper transport and acute-phase biology only, and says so. Four independent datasets, never pooled: the modern anchor (1,706 healthy Italian blood donors, 2024) derives quantile-regression reference curves in mg/dL — the upper reference value plateauing at about 25 mg/dL around age 25 in men, while in women it rose to about 45 mg/dL in young adults before falling below 30 mg/dL after the fifties. The oestrogen effect is large: in 200 healthy young women (1987), oral-contraceptive users averaged 181 ± 43.9 IU/ml against 110 ± 22.7 IU/ml in non-users — a ~65% higher mean, a relative comparison labelled as such. Units are assay-era property (IU/ml in 1987 vs mg/dL in 2024) and are never converted or merged. Three of the four datasets are women-only or women-predominant, so sex and hormonal status print on every card and no mixed 'adult range' is offered. The Zairean dataset's non-pregnant / non-lactating subgroup is small (N = 27) and prints as such; the Omani dataset's N is not documented in its record and prints as such. This shelf gives reference values only — Wilson-disease diagnostic accuracy is a different question and is not asked here. PHYSIOLOGY — EMERGING (see proposedStamp).
MeSH: Humans · Ceruloplasmin/analysis,metabolism · Male · Female · Adult · Reference Values · Middle Aged · Italy · Adolescent · Young Adult · Aged · Healthy Volunteers · Biomarkers/blood · Age Factors · Iron/blood · Sex Factors · Ceruloplasmin/analysis · Contraceptive Agents, Female/pharmacology · Copper/blood · Parity · Zinc/blood · Breast Feeding · C-Reactive Protein/analysis · Confidence Intervals · Democratic Republic of the Congo · Evaluation Studies as Topic · Haptoglobins/analysis · Immunodiffusion · Inflammation/blood · Orosomucoid/analysis · Pregnancy/blood · Albumins · Ceruloplasmin · Cholesterol/blood · Oman · Prevalence · Smoking · Vitamin A/blood · alpha-Tocopherol/blood
Cards (5)
Card 1 — Italian blood-donor reference curves (Pelucchi 2024): 1,706 healthy donors — upper reference value plateaus at ~25 mg/dL in men, but reaches ~45 mg/dL in young women before falling below 30 mg/dL after the fifties
Study: Primary human physiology dataset (quantile-regression reference curves, healthy blood donors)
Population: 1,706 consecutive healthy Italian blood donors (1,285 men and 421 women) aged 18 to 65 years, enrolled May 2019 to July 2022; serum ceruloplasmin reference intervals identified through quantile regression, with relationships to age, sex, iron and metabolic status examined by linear regression.
Summary: Italian blood-donor reference curves (Pelucchi 2024): 1,706 healthy donors — upper reference value plateaus at ~25 mg/dL in men, but reaches ~45 mg/dL in young women before falling below 30 mg/dL after the fifties
Result: Mean serum ceruloplasmin was influenced by sex and slightly by age. The lower reference value rose slightly with increasing age in both men and women and did not appear to be influenced by sex. The upper reference value differed by sex and age: in men it increased to a plateau of about 25 mg/dL around 25 years of age, while in women it initially increased to around 45 mg/dL in young adults and then fell sharply to below 30 mg/dL for adults after their fifties — a pattern the authors suggest possibly reflects differing hormonal status. The study's product is sex- and age-specific reference curves, not a single adult interval.
Watch out: Blood donors are a screened-healthy population and the female curve's high young-adult upper value (~45 mg/dL) is precisely why a single mixed-sex interval would mislead; the record reports the curves' shape and plateau values, and this card claims no single 2.5th–97.5th percentile pair from it.
Source: Pelucchi S et al. Reference Values of Ceruloplasmin across the Adult Age Range in a Large Italian Healthy Population. The journal of applied laboratory medicine. 2024. PMID: 39239918. Registry ID: none in the record. MeSH: Humans · Ceruloplasmin/analysis,metabolism · Male · Female · Adult · Reference Values · Middle Aged · Italy · Adolescent · Young Adult · Aged · Healthy Volunteers · Biomarkers/blood · Age Factors · Iron/blood · Sex Factors
Card 2 — Oestrogen effect in young women (Heese 1987): ceruloplasmin 181 ± 43.9 IU/ml in oral-contraceptive users vs 110 ± 22.7 IU/ml in non-users — a ~65% higher mean (relative comparison)
Study: Primary human physiology dataset (reference values partitioned by oral-contraceptive use, women only)
Population: 200 healthy nulliparous female students aged 18–23 years resident in Cape Town: 100 who had been taking low-dosage triphasic oral contraceptives for a minimum of 3 months, and 100 not taking contraceptives; reference values established for serum copper, ceruloplasmin, zinc and haematological indices.
Summary: Oestrogen effect in young women (Heese 1987): ceruloplasmin 181 ± 43.9 IU/ml in oral-contraceptive users vs 110 ± 22.7 IU/ml in non-users — a ~65% higher mean (relative comparison)
Result: Mean ceruloplasmin was 181 ± 43.9 IU/ml in contraceptive users versus 110 ± 22.7 IU/ml in non-users — users' mean about 65% higher, a relative comparison labelled as such; both differences from non-users were statistically significant. Mean serum copper showed the same pattern (26.5 ± 4.2 µmol/L in users versus 16.9 ± 2.7 µmol/L in non-users), while serum zinc did not differ (14.1 ± 2.1 vs 14.7 ± 2.0 µmol/L). There were no differences in haematological parameters except a significantly higher mean corpuscular volume in contraceptive users.
Watch out: Units are IU/ml (1987 assay era) and are never converted to or merged with the mg/dL values of the 2024 dataset; the population is women aged 18–23 only, and the contraceptive formulations of 1987 are not today's — the card establishes the size and direction of the oestrogen effect, not a current pill-specific value.
Source: Heese HD et al. Reference values for serum copper, ceruloplasmin and zinc and haematological indices for healthy nulliparous females. South African medical journal = Suid-Afrikaanse tydskrif vir geneeskunde. 1987. PMID: 3660157. Registry ID: none in the record. MeSH: Adult · Ceruloplasmin/analysis · Contraceptive Agents, Female/pharmacology · Copper/blood · Female · Humans · Iron/blood · Parity · Reference Values · Zinc/blood
Card 3 — Zairean women's reference levels (Kuvibidila 1994): ceruloplasmin and CRP means higher in pregnancy; non-pregnant women's ceruloplasmin sat within published Western ranges (non-pregnant subgroup N = 27)
Study: Primary human physiology dataset (reference levels by pregnancy / lactation status, women only)
Population: 419 healthy Zairean women of reproductive age (15–45 years): 180 lactating (Group I), 212 pregnant (Group II) and 27 neither pregnant nor lactating (Group III); acute-phase proteins including ceruloplasmin measured by radial immunodiffusion. The non-pregnant / non-lactating subgroup — the group comparable to a general reference population — is small (N = 27) and prints as such.
Summary: Zairean women's reference levels (Kuvibidila 1994): ceruloplasmin and CRP means higher in pregnancy; non-pregnant women's ceruloplasmin sat within published Western ranges (non-pregnant subgroup N = 27)
Result: The ranges for the acute-phase proteins were wider than for Western adults. The means and medians of alpha 1-acid glycoprotein were lower in pregnant than non-pregnant women, and those of C-reactive protein and ceruloplasmin were higher in pregnancy. In non-pregnant women, the mean levels and 95% confidence limits of CRP, ceruloplasmin and haptoglobin were within published ranges for healthy Western adults, while those of alpha 1-acid glycoprotein were higher; in pregnant women only alpha 1-acid glycoprotein and haptoglobin were within published ranges. The fetched record prints no numeric ceruloplasmin values, and this card claims none — its content is the pregnancy elevation and the Western-range concordance in non-pregnant women.
Watch out: Women only, an acute-phase-reactant panel measured by radial immunodiffusion in 1994, and the key comparison subgroup has N = 27: the dataset supports 'pregnancy raises ceruloplasmin; non-pregnant values concord with Western ranges' and nothing more precise.
Source: Kuvibidila S et al. Reference levels of acute phase reactant proteins in healthy Zairean women in the reproductive age group. The Journal of tropical medicine and hygiene. 1994. PMID: 8064948. Registry ID: none in the record. MeSH: Adolescent · Adult · Age Factors · Breast Feeding · C-Reactive Protein/analysis · Ceruloplasmin/analysis · Confidence Intervals · Democratic Republic of the Congo · Evaluation Studies as Topic · Female · Haptoglobins/analysis · Humans · Immunodiffusion · Inflammation/blood · Middle Aged · Orosomucoid/analysis · Pregnancy/blood · Reference Values
Card 4 — Omani reference ranges (Abiaka 2008): ceruloplasmin by immunonephelometry significantly higher in women than men; N not documented in the record
Study: Primary human physiology dataset (reference ranges in healthy adults, both sexes; N not documented in the record)
Population: Healthy Omani men and women — N not documented in the record (the fetched record does not print the sample size, and none is claimed). Ceruloplasmin ('caeruloplasmin' in the record) was measured by immunonephelometry, alongside copper and zinc by atomic absorption spectrophotometry and albumin and cholesterol by spectrophotometry.
Summary: Omani reference ranges (Abiaka 2008): ceruloplasmin by immunonephelometry significantly higher in women than men; N not documented in the record
Result: Reference ranges of serum micronutrient concentrations and micromineral ratios were established for Omani subjects. Significantly higher (P < 0.0001) copper and ceruloplasmin concentrations, copper:zinc and copper:ceruloplasmin ratios, and lower zinc, retinol, alpha-tocopherol and cholesterol concentrations were present in women compared with men. The copper:caeruloplasmin ratio was 6.99 ± 0.84 µmol/g overall (mean ± SD). Age was associated with ceruloplasmin concentrations in men, and smokers had lower copper:caeruloplasmin ratios than non-smokers (P = 0.002). Deficiency incidence was ≤5% for all investigated parameters. The fetched record prints no numeric ceruloplasmin concentration or interval, and this card claims none — its content is the established ranges' existence and the significant female-higher sex difference.
Watch out: With N not documented in the record and no numeric ceruloplasmin values printed there, this dataset corroborates the sex difference and the practice of population-specific ranges; it cannot be weighted against the 1,706-donor dataset or quoted for a number.
Source: Abiaka C et al. Serum micronutrient and micromineral concentrations and ratios in healthy Omani subjects. Medical principles and practice : international journal of the Kuwait University, Health Science Centre. 2008. PMID: 18523404. Registry ID: none in the record. MeSH: Adolescent · Adult · Albumins · Ceruloplasmin · Cholesterol/blood · Copper/blood · Female · Humans · Male · Middle Aged · Oman · Prevalence · Reference Values · Sex Factors · Smoking · Vitamin A/blood · Zinc/blood · alpha-Tocopherol/blood
Card 5 — Synthesis: ceruloplasmin reference values are sex-, age- and hormone-dependent — upper reference ~25 mg/dL in men vs ~45 mg/dL in young women (2024, mg/dL), with oral contraceptives raising the mean by ~65% (1987, IU/ml, never merged)
Study: Synthesis
Population: Synthesis of the four primary datasets carded above.
Summary: Synthesis: ceruloplasmin reference values are sex-, age- and hormone-dependent — upper reference ~25 mg/dL in men vs ~45 mg/dL in young women (2024, mg/dL), with oral contraceptives raising the mean by ~65% (1987, IU/ml, never merged)
Result: Framed by the primary reference literature alone — Guyton & Hall and Boron & Boulpaep carry no ceruloplasmin reference chapter, and the textbooks frame only copper transport and acute-phase biology. Pelucchi 2024 (1,706 Italian donors) gives the modern curves in mg/dL: upper reference plateau ~25 mg/dL in men from about age 25, ~45 mg/dL in young women falling below 30 mg/dL after the fifties, with the lower reference value rising slightly with age in both sexes. Heese 1987 (200 young women) quantifies the oestrogen effect in IU/ml: 181 ± 43.9 on oral contraceptives versus 110 ± 22.7 off them, a ~65% higher mean (relative comparison). Kuvibidila 1994 (419 Zairean women; non-pregnant subgroup N = 27) found ceruloplasmin higher in pregnancy and non-pregnant values within published Western ranges, printing no numeric values in its record. Abiaka 2008 (Omani adults, N not documented in the record) established ranges with ceruloplasmin significantly higher in women. PHYSIOLOGY — EMERGING: the direction of every modifier (female sex, oestrogen, pregnancy) is consistent across four datasets spanning 1987–2024, but the units and assays are era-bound and unmergeable, three datasets are women-only or women-predominant, and only one dataset is large and modern.
Watch out: Never convert IU/ml (1987) into mg/dL (2024) or pool the datasets into one adult range: sex and hormonal status are part of every value. This shelf is reference values only — it says nothing about ceruloplasmin's diagnostic accuracy for Wilson disease.
Source: Synthesis of the reports carded above; no additional source.