SourceMed · Shelf #7714 in the ask interface

STRATIFY falls tool: pooled sensitivity 67.2% and specificity 51.2% in geriatric rehabilitation — but sensitivity collapsed to 11.3% after stroke at the same ≥2 cut-off, so its accuracy is a property of the setting, not the tool

Shelf #7714 · Geriatrics, frailty & deprescribing

PREDICTIVE PERFORMANCE — STRATIFY at the standard ≥2 cut-off predicts falls only modestly where it performs best (pooled geriatric-rehabilitation sensitivity 67.2%, specificity 51.2%, positive predictive value 23.1%) and collapses in transport (stroke rehabilitation sensitivity 11.3%; nursing-home sensitivity 50%; 93,347-record acute-care validation sensitivity 0.672, specificity 0.612, AUC 0.69); no card implies that scoring, or any bundle a high score triggers, prevents falls

Stamped: 2026-11-28.

Evidence published: 2006–2023.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In hospitalised adults, how well does the STRATIFY falls risk-assessment tool (recent falls, agitation, visual impairment, frequent toileting, impaired transfer / mobility; standard high-risk cut-off ≥2) predict who will fall during the admission — what pooled sensitivity and specificity does it deliver in geriatric rehabilitation, and how far does its accuracy collapse in stroke rehabilitation, nursing-home and general acute-care validations?

Balance of the evidence

PREDICTIVE PERFORMANCE — modest at best, and setting-bound. The pooled geriatric-rehabilitation figures (Oliver 2008: sensitivity 67.2%, specificity 51.2%, PPV 23.1%, NPV 86.5%) are the tool's best case, and even there three of four flagged patients do not fall. Transport is the story: after stroke, sensitivity was 11.3% in the first 28 days (Smith 2006) — the tool missed almost nine of ten fallers; in a nursing home, sensitivity was 50% with a relative risk of falling of 2.35 at ≥2 (Wijnia 2006, a relative measure); and in 93,347 general acute-care records, sensitivity was 0.672 and specificity 0.612 with an AUC of 0.69 (Cortés 2023). A single sensitivity/specificity pair for STRATIFY does not exist; every pair on this shelf prints with its setting and cut-off. This is a prognostic-accuracy shelf, not a treatment shelf: nothing here shows that scoring patients, or acting on a high score, prevents a fall. Distinct instruments, distinct shelves: Morse is #7650 and Hendrich II is a separate row — no anchor is shared.

MeSH: Accidental Falls/prevention & control · Aged · Forecasting · Geriatric Assessment/methods · Humans · Inpatients · Middle Aged · Probability · Reproducibility of Results · Sensitivity and Specificity · Accidental Falls/prevention & control,statistics & numerical data · Acute Disease · Adult · Aged, 80 and over · Cohort Studies · Female · Follow-Up Studies · Male · Mobility Limitation · Predictive Value of Tests · Prospective Studies · ROC Curve · Risk Assessment · Stroke/complications · Stroke Rehabilitation · Netherlands · Nursing Homes · Proportional Hazards Models · Risk Assessment/methods · Retrospective Studies · Tertiary Care Centers · Colombia · Risk Factors

Cards (5)

Card 1 — Meta-analysis (Oliver 2008): in geriatric rehabilitation, STRATIFY pooled sensitivity 67.2%, specificity 51.2%, PPV 23.1%, NPV 86.5% — with significant heterogeneity for specificity and predictive values

Study: Systematic review and meta-analysis of prospective STRATIFY validations (8 studies reviewed; 4 geriatric-rehabilitation studies pooled)

Population: Systematic review of prospective STRATIFY validation studies in hospital inpatients: 8 studies eligible for the review and 4 conducted in geriatric rehabilitation settings pooled in the meta-analysis (precision-weighted fixed- and random-effects models).

Summary: Meta-analysis (Oliver 2008): in geriatric rehabilitation, STRATIFY pooled sensitivity 67.2%, specificity 51.2%, PPV 23.1%, NPV 86.5% — with significant heterogeneity for specificity and predictive values

Result: Using a random-effects model in the four geriatric-rehabilitation studies: sensitivity 67.2% (95% CI 60.8 to 73.6), specificity 51.2% (95% CI 43.0 to 59.3), positive predictive value 23.1% (95% CI 14.9 to 31.2) and negative predictive value 86.5% (95% CI 78.4 to 94.6). The homogeneity test was not significant for sensitivity (P = 0.36) but was significant (P < 0.01) for specificity, PPV and NPV; total predictive accuracy across the four studies varied from 43.2% to 60.0%. The authors conclude the relatively high NPV and low PPV and accuracy suggest STRATIFY may not be optimal for identifying high-risk individuals for fall prevention, and that population and setting affect its performance.

Watch out: The pooled pair is a geriatric-rehabilitation figure only. A PPV of 23.1% means most patients flagged high-risk do not fall — print it beside the sensitivity wherever the pooled figures are used.

Source: Oliver D et al. A systematic review and meta-analysis of studies using the STRATIFY tool for prediction of falls in hospital patients: how well does it work? Age and ageing. 2008. PMID: 18829693. Registry ID: none in the record. MeSH: Accidental Falls/prevention & control · Aged · Forecasting · Geriatric Assessment/methods · Humans · Inpatients · Middle Aged · Probability · Reproducibility of Results · Sensitivity and Specificity

Card 2 — Stroke rehabilitation (Smith 2006): STRATIFY sensitivity only 11.3% for falls in the first 28 days (specificity 89.5%) and 16.3% after discharge — the tool performed poorly after stroke

Study: Prospective multicentre cohort validation of STRATIFY in stroke rehabilitation (225 patients, 28-day inpatient study)

Population: Prospective multicentre cohort in six stroke rehabilitation units in the North of England: 225 patients contributed to the 28-day inpatient study (of 387 admitted during the study period) and 234 were followed up at 3 months after discharge; STRATIFY was scored on admission, weekly and before discharge.

Summary: Stroke rehabilitation (Smith 2006): STRATIFY sensitivity only 11.3% for falls in the first 28 days (specificity 89.5%) and 16.3% after discharge — the tool performed poorly after stroke

Result: STRATIFY performed poorly in predicting falls in the first 28 days (sensitivity 11.3% and specificity 89.5%) and after discharge (sensitivity 16.3% and specificity 86.4%). Agreement was 'fair' between baseline and discharge scores (kappa = 0.263) and 'good' between the pre-discharge score and the score from the preceding week (kappa = 0.639). The authors conclude STRATIFY performed poorly in a heterogeneous stroke population and that a disease-specific rather than generic falls tool is needed.

Watch out: High specificity with 11.3% sensitivity is a tool that rarely flags anyone — including almost all eventual fallers. Do not average this pair with the geriatric-rehabilitation pool; the collapse is the finding.

Source: Smith J et al. Use of the 'STRATIFY' falls risk assessment in patients recovering from acute stroke. Age and ageing. 2006. PMID: 16368736. Registry ID: none in the record. MeSH: Accidental Falls/prevention & control,statistics & numerical data · Acute Disease · Adult · Aged · Aged, 80 and over · Cohort Studies · Female · Follow-Up Studies · Humans · Male · Middle Aged · Mobility Limitation · Predictive Value of Tests · Prospective Studies · ROC Curve · Reproducibility of Results · Risk Assessment · Sensitivity and Specificity · Stroke/complications · Stroke Rehabilitation

Card 3 — Nursing home (Wijnia 2006): at STRATIFY ≥2 the relative risk of falling was 2.35 (95% CI 1.22 to 4.52), a relative measure — with sensitivity 50% and specificity 76.2%

Study: Prospective nursing-home validation of STRATIFY (120 newly admitted patients)

Population: Prospective study in one Rotterdam nursing home: 120 newly admitted patients (75 women, 45 men, average age 74.5 years) with a STRATIFY score, followed for falls over a 13-week observation period; 36 patients (30%) fell.

Summary: Nursing home (Wijnia 2006): at STRATIFY ≥2 the relative risk of falling was 2.35 (95% CI 1.22 to 4.52), a relative measure — with sensitivity 50% and specificity 76.2%

Result: The risk of falling in patients with a STRATIFY score of 2 or more was 2.35 (95% confidence interval: 1.22, 4.52) times that of patients with a lower score — a relative risk, printed as published. Sensitivity was 50% (95% CI: 32, 67) and specificity 76.2% (95% CI: 65, 87.5). The authors describe the results in their setting as disappointing. During the 3 months, 24 of the 120 patients (20%) had died and 56 (47%) had been discharged.

Watch out: A relative risk of 2.35 on a 30% fall base still leaves the tool missing half of fallers (sensitivity 50%). Single home, 120 patients — the pair belongs to this setting only.

Source: Wijnia JW et al. Validity of the STRATIFY risk score of falls in nursing homes. Preventive medicine. 2006. PMID: 16297975. Registry ID: none in the record. MeSH: Accidental Falls/prevention & control,statistics & numerical data · Aged · Female · Humans · Male · Netherlands · Nursing Homes · Proportional Hazards Models · Prospective Studies · Risk Assessment/methods · Sensitivity and Specificity

Card 4 — General acute care (Cortés 2023): 93,347 hospital records — sensitivity 0.672, specificity 0.612, positive likelihood ratio 1.73, AUC 0.69

Study: Retrospective external validation of STRATIFY in general acute care (93,347 hospital records)

Population: Retrospective external validation in a Colombian tertiary hospital: 93,347 patient hospital records (mean age 56.9 years, 50.2% women), adults admitted 2018–2020 with a STRATIFY score recorded at admission, assessed for falls during the admission.

Summary: General acute care (Cortés 2023): 93,347 hospital records — sensitivity 0.672, specificity 0.612, positive likelihood ratio 1.73, AUC 0.69

Result: Overall sensitivity was 0.672 (95% CI 0.612 to 0.723), specificity 0.612 (95% CI 0.605 to 0.615) and positive likelihood ratio 1.73 (95% CI 1.589 to 1.891) — a likelihood ratio, printed as published. The area under the ROC curve was 0.69 (95% CI 0.66 to 0.72), and age subgroups gave similar results. The authors conclude that applying STRATIFY at admission resulted in lower performance for predicting falls and that individual evaluation of fall risk factors is needed.

Watch out: Retrospective record-based validation: the score was taken as recorded at admission in routine care, not administered for research. Its 0.69 AUC in undifferentiated acute care — not the geriatric-rehabilitation pool — is the figure for general wards.

Source: Cortés OL et al. Validation of the stratify scale for the prediction of falls among hospitalized adults in a tertiary hospital in Colombia: a retrospective cohort study. Scientific reports. 2023. PMID: 38062044. Registry ID: none in the record. MeSH: Adult · Humans · Female · Male · Retrospective Studies · Tertiary Care Centers · Accidental Falls/prevention & control · Colombia · Risk Assessment/methods · Risk Factors

Card 5 — Synthesis: STRATIFY's accuracy is a property of the setting — pooled sensitivity 67.2% / specificity 51.2% in geriatric rehabilitation, sensitivity 11.3% after stroke, 50% in a nursing home (relative risk 2.35 at ≥2, a relative measure), and 0.672 / 0.612 with AUC 0.69 across 93,347 acute-care records; no pooled pair travels

Study: Synthesis

Population: All reports carded on this shelf: one systematic review and meta-analysis (8 studies reviewed, 4 pooled), one prospective stroke-rehabilitation cohort (225 patients), one prospective nursing-home cohort (120 patients) and one retrospective acute-care validation (93,347 records). The modified, re-weighted Canadian version of the tool is a derivative instrument and is not carded as a validation of the original.

Summary: Synthesis: STRATIFY's accuracy is a property of the setting — pooled sensitivity 67.2% / specificity 51.2% in geriatric rehabilitation, sensitivity 11.3% after stroke, 50% in a nursing home (relative risk 2.35 at ≥2, a relative measure), and 0.672 / 0.612 with AUC 0.69 across 93,347 acute-care records; no pooled pair travels

Result: Every validation agrees the tool discriminates weakly (AUC 0.69 where measured; PPV 23.1% in its best setting), and they disagree on where the errors fall: stroke rehabilitation keeps specificity (89.5%) by sacrificing sensitivity (11.3%), while geriatric rehabilitation balances at 67.2% / 51.2%. Print each pair with its setting and the ≥2 cut-off, and never as evidence that fall-prevention action works — no card on this shelf tests an intervention.

Watch out: See the individual cards for each report's limits; this synthesis adds no new data.

Source: Synthesis of the reports carded above; no additional source.