SourceMed · Shelf #7716 in the ask interface
3D-CAM delirium interview: sensitivity 95% and specificity 94% at derivation in 201 inpatients aged ≥75 (sensitivity 96% / specificity 86% in dementia), 94% / 97% for the Chinese version on general units — and 84.6–87.2% / 96.7–97.4% in surgical ICU, at a median 3 minutes
Shelf #7716 · Brain, stroke & mind
DIAGNOSTIC ACCURACY — the 3D-CAM diagnoses CAM-defined delirium accurately in about 3 minutes (derivation sensitivity 95%, specificity 94%; Chinese general-unit version sensitivity 94% / specificity 97%), with sensitivity lower in surgical ICU (84.6–87.2% across two interviewers, specificity 96.7–97.4%); two of three reports validate the Chinese translation, stated on every card
Stamped: 2026-11-28.
Evidence published: 2014–2021.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In hospitalised older adults on general wards and in surgical intensive care, how accurately does the 3D-CAM (the 3-minute diagnostic interview operationalising the Confusion Assessment Method) diagnose delirium against an expert / DSM reference standard — what sensitivity and specificity does it deliver in its derivation population, in patients with dementia, and in translated-version validations, and how long does it take at the bedside?
Balance of the evidence
DIAGNOSTIC ACCURACY — high, with a setting gradient and a translation caveat. At derivation (Marcantonio 2014; the instrument originators' own report, labelled as such), the 3D-CAM reached sensitivity 95% and specificity 94% against an expert-panel reference standard in 201 inpatients aged ≥75, and held up in dementia (96% / 86%). The Chinese version on general units matched it (Ji 2021: 94% / 97% in 204 patients). In surgical ICU the same translated instrument lost sensitivity (Mu 2020: 87.2% and 84.6% for two interviewers; specificity 96.7% and 97.4%; kappa 0.82) — roughly one in seven delirious patients missed. Median administration was about 3 minutes in both ward studies. Two of the three reports validate the Chinese version: independent cohorts and centres, but the derivation figures may not be presented as replicated in the original-language form outside the derivation centre. A diagnostic-accuracy shelf only — nothing here tests whether finding delirium with the 3D-CAM changes treatment or outcomes. Distinct instruments: CAM-ICU (for patients who cannot speak) and 4AT are separate shelves with no shared anchor.
MeSH: Aged · Aged, 80 and over · Algorithms · Confusion · Cross-Sectional Studies · Delirium/diagnosis · Female · Hospitalization · Humans · Interviews as Topic · Male · Neuropsychological Tests · Reproducibility of Results · Sensitivity and Specificity · China · Intensive Care Units · Prospective Studies · Cross-Cultural Comparison · Postoperative Cognitive Complications/diagnosis
Cards (4)
Card 1 — Derivation and validation (Marcantonio 2014 — the instrument originators' own report): 201 inpatients aged ≥75, 21% delirium — sensitivity 95% (95% CI 84% to 99%), specificity 94% (90% to 97%), median administration 3 minutes; in dementia, 96% / 86%
Study: Derivation and prospective validation of the 3D-CAM (originators' report; 201 inpatients aged ≥75)
Population: 201 inpatients aged 75 years or older (mean age 84; 28% with dementia) on 4 general medicine units at one academic medical centre; the 20 items best operationalising the 4 CAM features formed the 3D-CAM, administered prospectively by trained research assistants and compared with an expert-panel reference standard built from clinician assessments, patient and family interviews and record review. Programme-labelled: this is the instrument originators' own derivation / validation report.
Summary: Derivation and validation (Marcantonio 2014 — the instrument originators' own report): 201 inpatients aged ≥75, 21% delirium — sensitivity 95% (95% CI 84% to 99%), specificity 94% (90% to 97%), median administration 3 minutes; in dementia, 96% / 86%
Result: The expert panel identified 21% with delirium, 88% of whom had hypoactive or normal psychomotor features. Median 3D-CAM administration time was 3 minutes (interquartile range 2 to 5). Sensitivity was 95% (95% CI, 84% to 99%) and specificity 94% (CI, 90% to 97%). In patients with dementia, sensitivity was 96% (CI, 82% to 100%) and specificity 86% (CI, 67% to 96%); without dementia, 93% (CI, 66% to 100%) and 96% (CI, 91% to 99%). The authors note the limits: single-centre, cross-sectional, medical patients only.
Watch out: Single-centre derivation by the instrument's own developers, in medical inpatients only — the 95% / 94% pair is a derivation-centre figure until replicated in the original language elsewhere; the dementia specificity interval is wide (67% to 96%).
Source: Marcantonio ER et al. 3D-CAM: derivation and validation of a 3-minute diagnostic interview for CAM-defined delirium: a cross-sectional diagnostic test study. Annals of internal medicine. 2014. PMID: 25329203. Registry ID: none in the record. MeSH: Aged · Aged, 80 and over · Algorithms · Confusion · Cross-Sectional Studies · Delirium/diagnosis · Female · Hospitalization · Humans · Interviews as Topic · Male · Neuropsychological Tests · Reproducibility of Results · Sensitivity and Specificity
Card 2 — Chinese version, general units (Ji 2021): 204 hospitalised older adults, 54 with delirium — sensitivity 94%, specificity 97%, median assessment about 3 minutes
Study: Prospective validation of the Chinese 3D-CAM in general units (204 hospitalised older adults)
Population: 204 hospitalised older adults at a geriatric hospital, assessed prospectively with the Chinese version of the 3D-CAM by nurse researchers; 54 were identified as positive for delirium by the reference process described in the report.
Summary: Chinese version, general units (Ji 2021): 204 hospitalised older adults, 54 with delirium — sensitivity 94%, specificity 97%, median assessment about 3 minutes
Result: The sensitivity and specificity of the 3D-CAM Chinese version were 94% and 97%, respectively. The median duration of assessment was about 3 minutes. The authors conclude the Chinese version had highly acceptable sensitivity and specificity when used by nurse researchers among Chinese older adults on general units.
Watch out: A translation validation: it supports the instrument's performance in Chinese-speaking general-unit patients assessed by nurse researchers, and does not by itself replicate the English-language derivation. The abstract reports no confidence intervals for the 94% / 97% pair.
Source: Ji M et al. Validation of the 3-minute diagnostic interview for CAM-defined Delirium in Chinese older adults. Geriatric nursing (New York, N.Y.). 2021. PMID: 33197703. Registry ID: ChiCTR1900023921. MeSH: Aged · China · Delirium/diagnosis · Humans · Intensive Care Units · Prospective Studies · Reproducibility of Results · Sensitivity and Specificity
Card 3 — Chinese version, surgical ICU (Mu 2020): 245 patients, 647 paired assessments against a DSM-5 psychiatrist panel — sensitivity 87.2% and 84.6%, specificity 96.7% and 97.4% for two interviewers, kappa 0.82
Study: Cross-cultural validation of the Chinese 3D-CAM in surgical ICU (245 patients, 647 paired assessments)
Population: 245 adult surgical-ICU patients assessed on postoperative days 1–3 with the culturally adapted Chinese 3D-CAM (3D-CAM-CN) by two independent interviewers, yielding 647 paired assessments; the reference standard was delirium diagnosis by a psychiatrist panel applying DSM-5 criteria.
Summary: Chinese version, surgical ICU (Mu 2020): 245 patients, 647 paired assessments against a DSM-5 psychiatrist panel — sensitivity 87.2% and 84.6%, specificity 96.7% and 97.4% for two interviewers, kappa 0.82
Result: Against the reference standard, sensitivity and specificity were 87.2% and 96.7% for interviewer A and 84.6% and 97.4% for interviewer B, with good interrater reliability (kappa coefficient = 0.82, P < 0.001). In patients with mild cognitive impairment, sensitivity ranged from 85.7% to 100% and specificity from 95.7% to 96.4%. The authors conclude the 3D-CAM-CN can be used as a reliable and accurate instrument for delirium assessment in surgical patients.
Watch out: Sensitivity fell 8–10 points from the ward validations — in an ICU population that is sicker and harder to interview. The 647 figure is paired assessments in 245 patients; the patient N is the evidence size.
Source: Mu DL et al. Cross-cultural adaptation and validation of the 3D-CAM Chinese version in surgical ICU patients. BMC psychiatry. 2020. PMID: 32204700. Registry ID: ChiCTR-OOC-17011887. MeSH: Aged · Cross-Cultural Comparison · Delirium/diagnosis · Female · Humans · Intensive Care Units · Male · Postoperative Cognitive Complications/diagnosis · Prospective Studies · Reproducibility of Results · Sensitivity and Specificity
Card 4 — Synthesis: the 3D-CAM is a 3-minute interview with derivation accuracy of 95% / 94%, matched by the Chinese version on general wards (94% / 97%) but with sensitivity down to 84.6–87.2% in surgical ICU — and two of the three validations are of the translation, not the original instrument
Study: Synthesis
Population: All reports carded on this shelf: the derivation / validation study (201 inpatients aged ≥75; originators' report, labelled), the Chinese general-unit validation (204 patients) and the Chinese surgical-ICU validation (245 patients, 647 paired assessments).
Summary: Synthesis: the 3D-CAM is a 3-minute interview with derivation accuracy of 95% / 94%, matched by the Chinese version on general wards (94% / 97%) but with sensitivity down to 84.6–87.2% in surgical ICU — and two of the three validations are of the translation, not the original instrument
Result: Read together: specificity is stable across settings (94–97.4%) while sensitivity is the moving part (95% at derivation, 94% on Chinese general units, 84.6–87.2% in surgical ICU). Administration takes a median of about 3 minutes where timed. The translation status prints on every card: performance of the original-language instrument outside its derivation centre is, on this evidence, still a derivation-centre claim.
Watch out: See the individual cards for each report's limits; this synthesis adds no new data.
Source: Synthesis of the reports carded above; no additional source.