SourceMed · Shelf #7719 in the ask interface
Serum anion gap reference interval: 3–11 mmol/L on ion-selective-electrode analysers, 5–10 / 9–14 / 8–13 mmol/L across three 1997 analysers, and 10–18 mmol/L in a contemporary screening population — the interval is analyser property, not a biological constant (5 datasets)
Shelf #7719 · Kidney, fluids & electrolytes
PHYSIOLOGY — ESTABLISHED — five independent datasets consistently establish that the serum anion gap reference interval is analyser- and derivation-specific (3–11 mmol/L on ion-selective-electrode analysers; 10–18 mmol/L in a contemporary health-screening derivation; 7–18 mmol/L in a large indirect derivation), so no interval prints without its analyser and derivation, and the intervals are never merged into one normal range
Stamped: 2026-11-28.
Evidence published: 1997–2022.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In healthy adults, what is the reference interval for the serum anion gap — the central range by analyser / method — how far apart do the published intervals sit (3–11 mmol/L on ion-selective-electrode analysers against 10–18 mmol/L in a contemporary screening population), how much of that spread is instrument and derivation method rather than biology, and how often does an outdated interval misclassify healthy people as having a high gap?
Balance of the evidence
PHYSIOLOGY — ESTABLISHED, as an instrument property. Textbook framing (Guyton & Hall; Boron & Boulpaep, acid–base sections) is brief — this shelf rests chiefly on the primary reference literature, and says so. Five datasets: three direct healthy-volunteer derivations (Roberts 1997: 5–10, 9–14 and 8–13 mmol/L on three analysers in the same volunteers; Lolekha 2001: 3–11 mmol/L on four ion-selective-electrode analysers in 124 volunteers, against 8–16 or 9–18 mmol/L on the older continuous-flow methods; Chionh 2022: 10–18 mmol/L in 284 screening volunteers) and two indirect derivations from patient populations with healthy or normal-electrolyte subgroups (Ayala-Lopez 2020: 7–18 mmol/L, median 13, in a 17,137-patient derivation, with 5% of healthy adults misclassified as high by the previous 6–16 mmol/L interval; Pratumvinit 2020: all-patient intervals 9–19, 5–15 and 5–15 mmol/L across three hospitals, with albumin shifting the gap). The 3–11 and 10–18 mmol/L intervals may never be merged: the spread is method, not biology. Values print in mmol/L, numerically equal to mEq/L for this monovalent calculated quantity. The potassium-inclusive gap (AGK, 14.6–22.5 mmol/L) is a different calculated quantity and is carded separately on its own card line.
MeSH: Acid-Base Equilibrium/physiology · Adult · Autoanalysis/instrumentation,standards · Blood Chemical Analysis/instrumentation,standards · Blood Specimen Collection · Calibration · Carbon Dioxide/blood · Chlorides/blood · Humans · Laboratories/standards · Middle Aged · Normal Distribution · Outcome Assessment, Health Care · Quality Control · Reference Values · Reproducibility of Results · Sodium/blood · Specimen Handling · Anions/standards · Clinical Chemistry Tests/standards · Electrolytes/standards · Acid-Base Imbalance/blood,diagnosis · Age Factors · Analysis of Variance · Biological Variation, Population · Child · Female · Male · Retrospective Studies · Acidosis/blood · Adolescent · Aged · Aged, 80 and over · Blood Chemical Analysis/standards · Serum Albumin/analysis · Young Adult · Acid-Base Equilibrium · Acidosis · Electrolytes
Cards (6)
Card 1 — Three-analyser volunteer study (Roberts 1997): the same healthy volunteers (aged 20–60) gave parametric intervals of 5–10 mmol/L (numerically equal to mEq/L for this monovalent calculated quantity) (Beckman Synchron CX3), 9–14 (Hitachi 717) and 8–13 (Vitros 950) — volunteer N not documented in the record
Study: Direct healthy-volunteer reference-interval derivation on three analysers (N not documented in the record)
Population: Healthy volunteers aged 20–60 recruited from within a clinical laboratory, with serum sodium, chloride and total carbon dioxide measured on aliquoted specimens across three clinical laboratories of one university medical centre; the volunteer N is not documented in the abstract and this card prints 'N not documented' per the standing reference-floor labelling rule.
Summary: Three-analyser volunteer study (Roberts 1997): the same healthy volunteers (aged 20–60) gave parametric intervals of 5–10 mmol/L (numerically equal to mEq/L for this monovalent calculated quantity) (Beckman Synchron CX3), 9–14 (Hitachi 717) and 8–13 (Vitros 950) — volunteer N not documented in the record
Result: Mean and standard deviations were calculated per method and parametric reference intervals (±2 SD) were 5 to 10 mmol/L for the Beckman Synchron CX3 analyser, 9 to 14 mmol/L for the Boehringer Mannheim Hitachi 717 analyser and 8 to 13 mmol/L for the Johnson & Johnson Vitros 950 analyser. The authors conclude that lowering the interval to 5–10 mmol/L may suit some analysers while 9–14 mmol/L suits others, and that laboratories must establish or verify the interval for their own instrumentation.
Watch out: Same volunteers, three intervals spanning 5–14 mmol/L: the cleanest demonstration on this shelf that the interval belongs to the analyser. N not documented — the card is a method comparison, never a population norm on its own.
Source: Roberts WL et al. The serum anion gap. Has the reference interval really fallen? Archives of pathology & laboratory medicine. 1997. PMID: 9199620. Registry ID: none in the record. MeSH: Acid-Base Equilibrium/physiology · Adult · Autoanalysis/instrumentation,standards · Blood Chemical Analysis/instrumentation,standards · Blood Specimen Collection · Calibration · Carbon Dioxide/blood · Chlorides/blood · Humans · Laboratories/standards · Middle Aged · Normal Distribution · Outcome Assessment, Health Care · Quality Control · Reference Values · Reproducibility of Results · Sodium/blood · Specimen Handling
Card 2 — Ion-selective-electrode derivation (Lolekha 2001): 124 healthy volunteers on four analysers — anion gap reference range 3–11 mmol/L (numerically equal to mEq/L for this monovalent calculated quantity), against 8–16 or 9–18 on the older continuous-flow analysers; the outdated range misinterprets values
Study: Direct healthy-volunteer reference-interval derivation on four ion-selective-electrode analysers (124 volunteers)
Population: 124 healthy volunteers; clotted and lithium-heparinised blood measured on the Beckman E4A and Beckman Synchron CX5 (serum), the Nova CRT (serum and plasma) and the Nova Stat Profile Ultra; anion gap calculated as [Na+ − (Cl− + HCO3−)]; reference ranges set by non-parametric percentile estimation.
Summary: Ion-selective-electrode derivation (Lolekha 2001): 124 healthy volunteers on four analysers — anion gap reference range 3–11 mmol/L (numerically equal to mEq/L for this monovalent calculated quantity), against 8–16 or 9–18 on the older continuous-flow analysers; the outdated range misinterprets values
Result: Electrolyte reference values were similar across analysers, with Nova bicarbonate ranges higher than Beckman values. For the anion gap, the reference ranges were low but similar to other ion-selective-electrode studies (3–11 mmol/L), and lower than the previous continuous-flow ranges (8–16 or 9–18 mmol/L) obtained with flame photometry and colorimetry. The authors warn that the widespread use of ion-selective electrodes has lowered the anion gap range and that using the outdated 8–16 mmol/L range leads to misinterpretation — an analyser-specific range must be used.
Watch out: The 3–11 mmol/L interval is the low anchor of this shelf and belongs to ion-selective-electrode measurement; printing it beside a modern screening interval (10–18) without the method note would manufacture a contradiction that is really a method change.
Source: Lolekha PH et al. Reference ranges of electrolyte and anion gap on the Beckman E4A, Beckman Synchron CX5, Nova CRT, and Nova Stat Profile Ultra. Clinica chimica acta; international journal of clinical chemistry. 2001. PMID: 11369341. Registry ID: none in the record. MeSH: Anions/standards · Clinical Chemistry Tests/standards · Electrolytes/standards · Humans · Reference Values · Reproducibility of Results
Card 3 — Large indirect derivation (Ayala-Lopez 2020): 17,137 adult and paediatric patients at Yale–New Haven — healthy-adult interval 7–18 mmol/L (numerically equal to mEq/L for this monovalent calculated quantity), median 13, and 5% of healthy adults misclassified as high by the previous 6–16 interval
Study: Indirect (retrospective patient-population) reference-interval derivation, 17,137 patients with a healthy-adult interval
Population: Retrospective derivation from 17,137 adult and paediatric patients presenting to Yale–New Haven Hospital outpatient clinics, emergency department or intensive care units, 2012–2017; the healthy-adult interval was derived within that population, with workup patterns, repeat-testing variation and a subgroup with annual testing also examined. Derivation kind: indirect (patient-population derivation with a healthy-adult interval), stated here per the shelf's derivation rule.
Summary: Large indirect derivation (Ayala-Lopez 2020): 17,137 adult and paediatric patients at Yale–New Haven — healthy-adult interval 7–18 mmol/L (numerically equal to mEq/L for this monovalent calculated quantity), median 13, and 5% of healthy adults misclassified as high by the previous 6–16 interval
Result: The new reference interval was 7 to 18 mmol/L with a median of 13 mmol/L in healthy adults, with no significant differences by sex or age partitioning. Against the previous interval of 6 to 16 mmol/L, 5% of healthy adults, 23% of emergency-department adults and 18% of intensive-care adults were misclassified as having high values. Most increased gaps that were repeated normalised by 12 hours, and in the annual-testing subgroup the median within-person change from 2015 to 2016 was about 13%. The authors argue for an appropriate interval and note a moderate degree of individuality.
Watch out: An indirect derivation: the 'healthy adult' interval is extracted from a hospital population, not measured in recruited volunteers — derivation kind prints with the interval. The 5% misclassification figure is the practical cost of an outdated interval.
Source: Ayala-Lopez N et al. Interpreting Anion Gap Values in Adult and Pediatric Patients: Examining the Reference Interval. The journal of applied laboratory medicine. 2020. PMID: 32445342. Registry ID: none in the record. MeSH: Acid-Base Equilibrium/physiology · Acid-Base Imbalance/blood,diagnosis · Adult · Age Factors · Analysis of Variance · Biological Variation, Population · Child · Female · Humans · Male · Reference Values · Retrospective Studies
Card 4 — Three-hospital instrument study (Pratumvinit 2020): all-patient intervals 9–19, 5–15 and 5–15 mmol/L (numerically equal to mEq/L for this monovalent calculated quantity) on two platforms; normal-electrolyte subgroup intervals 10–17, 6–14 and 5–12; hypoalbuminaemia lowered and hyperalbuminaemia raised the gap
Study: Indirect multi-hospital instrument-comparison derivation (consecutive adults, three hospitals, two platforms)
Population: Consecutive adults (≥18 years) with samples sent for electrolytes and creatinine at three Southeast Asian hospitals — one using the cobas 8000 and two the Architect c16000; intervals derived for all patients and for the subgroup with normal electrolytes, and compared by albumin group. Derivation kind: indirect (consecutive patient samples), stated per the shelf's rule.
Summary: Three-hospital instrument study (Pratumvinit 2020): all-patient intervals 9–19, 5–15 and 5–15 mmol/L (numerically equal to mEq/L for this monovalent calculated quantity) on two platforms; normal-electrolyte subgroup intervals 10–17, 6–14 and 5–12; hypoalbuminaemia lowered and hyperalbuminaemia raised the gap
Result: Anion gap means differed significantly (P < 0.001) between the three hospitals in all patients and in the normal-electrolyte subgroup. Reference intervals from all patients were 9–19, 5–15 and 5–15 mmol/L, and for the normal-electrolyte subgroup 10–17, 6–14 and 5–12 mmol/L respectively. Compared with the normal-albumin group, hypoalbuminaemia patients showed lower anion gaps in two hospitals (P < 0.001, P = 0.03), while hyperalbuminaemia patients showed higher gaps in all three (P < 0.001). The authors conclude different instruments produce different gaps, with a weak correlation between albumin and the gap.
Watch out: Two hospitals on the same platform (Architect c16000) still produced different subgroup intervals — population and derivation sit alongside instrument as sources of spread. Albumin shifts the gap, so an interval derived in low-albumin patients does not transfer to healthy adults.
Source: Pratumvinit B et al. Anion gap reference intervals show instrument dependence and weak correlation with albumin levels. Clinica chimica acta; international journal of clinical chemistry. 2020. PMID: 31669932. Registry ID: none in the record. MeSH: Acidosis/blood · Adolescent · Adult · Aged · Aged, 80 and over · Blood Chemical Analysis/standards · Female · Humans · Male · Middle Aged · Reference Values · Retrospective Studies · Serum Albumin/analysis · Young Adult
Card 5 — Contemporary screening derivation (Chionh 2022): 284 health-screening volunteers — verified interval 10–18 mmol/L (numerically equal to mEq/L for this monovalent calculated quantity) (median 13), unchanged in the 156-person no-suboptimal-indicators subcohort; the potassium-inclusive AGK interval was 14.6–22.5
Study: Direct health-screening-volunteer reference-interval derivation (284 volunteers; 156-person subcohort)
Population: 284 health-screening participants with no major illnesses who volunteered surplus blood, tested in an internationally accredited laboratory (median age 35 years, BMI 23.4 kg/m2, GFR 106 mL/min/1.73 m2); anion gap calculated as [Na+] − [Cl−] − [HCO3−] and AGK as [Na+] + [K+] − [Cl−] − [HCO3−]; intervals at the 2.5th–97.5th percentiles, with a subcohort of 156 individuals with no suboptimal health indicators.
Summary: Contemporary screening derivation (Chionh 2022): 284 health-screening volunteers — verified interval 10–18 mmol/L (numerically equal to mEq/L for this monovalent calculated quantity) (median 13), unchanged in the 156-person no-suboptimal-indicators subcohort; the potassium-inclusive AGK interval was 14.6–22.5
Result: Median anion gap was 13 mmol/L and the reference interval 10–18 mmol/L at a 99% level of confidence; the interval was the same in the 156-person subcohort. Statistically significant differences by sex, race, obesity and serum albumin amounted to 1 mmol/L between subgroups. Median AGK was 17.7 mmol/L with a reference interval of 14.6–22.5 mmol/L. The authors conclude the 10–18 mmol/L interval is valid for laboratories with similar electrolyte intervals, and that the lower values expected with current techniques were not observed.
Watch out: AGK (potassium-inclusive) is a different calculated quantity from the standard gap — its 14.6–22.5 mmol/L interval must never be quoted as an anion-gap interval. This contemporary direct derivation (10–18) sitting above the 2001 ion-selective derivation (3–11) is the shelf's central caution against merging intervals.
Source: Chionh CY et al. Serum anion gap revisited: a verified reference interval for contemporary use. Internal medicine journal. 2022. PMID: 34028972. Registry ID: none in the record. MeSH: Acid-Base Equilibrium · Acidosis · Adult · Electrolytes · Humans · Reference Values · Serum Albumin/analysis
Card 6 — Synthesis: five datasets, one lesson — the anion gap interval belongs to the analyser and the derivation (3–11 mmol/L by ion-selective electrode in 2001; 10–18 mmol/L in 2022 screening volunteers; 7–18 indirect), and an outdated interval misclassifies 5% of healthy adults as high
Study: Synthesis
Population: All datasets carded on this shelf: three direct healthy-volunteer derivations (Roberts 1997, N not documented; Lolekha 2001, 124 volunteers; Chionh 2022, 284 volunteers) and two indirect patient-population derivations (Ayala-Lopez 2020, 17,137 patients; Pratumvinit 2020, three hospitals). Textbook framing: Guyton & Hall and Boron & Boulpaep frame acid–base physiology briefly; this shelf rests chiefly on the primary reference literature, and says so.
Summary: Synthesis: five datasets, one lesson — the anion gap interval belongs to the analyser and the derivation (3–11 mmol/L by ion-selective electrode in 2001; 10–18 mmol/L in 2022 screening volunteers; 7–18 indirect), and an outdated interval misclassifies 5% of healthy adults as high
Result: No single 'normal anion gap' exists on this evidence. Within one 1997 study the same volunteers spanned 5–14 mmol/L across three analysers; across two decades the direct derivations span 3–18 mmol/L. Print every interval with its analyser, its derivation kind (direct volunteer vs indirect patient-population) and its population — and keep AGK (14.6–22.5 mmol/L) separate from the standard gap. Values are in mmol/L, numerically equal to mEq/L for this monovalent calculated quantity.
Watch out: See the individual cards for each report's limits; this synthesis adds no new data.
Source: Synthesis of the reports carded above; no additional source.