SourceMed · Shelf #7753 in the ask interface

Nu-DESC delirium screening on wards: sensitivity 0.98 and NPV 1.00 in the largest validation but PPV only 0.43 at 9% prevalence, and the cut-off is unsettled (Italian optimum 3, not the derivation cut-off)

Shelf #7753 · Geriatrics, frailty & deprescribing

PREDICTIVE PERFORMANCE — high sensitivity on wards (0.98 in the largest validation, NPV 1.00) but PPV only 0.43 at 9% prevalence and the cut-off unsettled (derivation vs Italian optimum of 3, sensitivity 100% / specificity 76%); derivation sensitivity was 85.7% in oncology inpatients; a diagnostic-accuracy stamp, not a treatment stamp

Stamped: 2026-11-28.

Evidence published: 2005–2020.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

On hospital wards, how accurately does the Nu-DESC (Nursing Delirium Screening Scale; five nurse-observed items) detect delirium against CAM / DSM reference standards — what sensitivity and specificity did its derivation study deliver, and what do the general-medical-ward and translated-version validations find, including the cut-off disagreement?

Balance of the evidence

MEASUREMENT PERFORMANCE — high sensitivity in the ward validations, with two numbers that must travel with it: the positive predictive value and the unsettled cut-off. At derivation (the originators' own report, oncology inpatients, CAM reference) sensitivity was 85.7% and specificity 86.8%. On German general medical wards (698 patients aged ≥65, DSM-5 reference, delirium occurrence 9.0%) sensitivity was 0.98 and specificity 0.87 — but PPV was only 0.43 at that prevalence, so most positive screens were not delirium. The Italian validation (101 elderly inpatients, CAM reference) found its optimum at a cut-off of 3, not the derivation cut-off, with sensitivity 100% and specificity 76% and AUC 0.946. No card prints one cut-off as universal. This is a diagnostic-accuracy shelf: no card claims Nu-DESC screening improves outcomes.

MeSH: Adolescent · Adult · Aged · Aged, 80 and over · Cohort Studies · Delirium · Female · Hospitalization · Humans · Male · Mass Screening · Mental Status Schedule · Middle Aged · Nursing Diagnosis · Psychiatric Status Rating Scales · Psychometrics · Reproducibility of Results · Sensitivity and Specificity · Severity of Illness Index · Single-Blind Method

Cards (4)

Card 1 — Nu-DESC derivation (Gaudreau 2005 — the originators' own report, oncology inpatient units): sensitivity 85.7% and specificity 86.8% against 59 blinded CAM ratings, with DSM-IV and MDAS co-ratings, in 146 consecutively assessed hospitalised patients

Study: Derivation study — the Nu-DESC originators' own report (programme-labelled), oncology inpatients, CAM reference standard

Population: 146 consecutive hospitalised patients on oncology inpatient units, continuously assessed for delirium symptoms by bedside nurses using the five-item Nu-DESC, against 59 blinded Confusion Assessment Method (CAM) ratings by research nurses and psychiatrists, with DSM-IV criteria and the Memorial Delirium Assessment Scale (MDAS) rated alongside.

Summary: Nu-DESC derivation (Gaudreau 2005 — the originators' own report, oncology inpatient units): sensitivity 85.7% and specificity 86.8% against 59 blinded CAM ratings, with DSM-IV and MDAS co-ratings, in 146 consecutively assessed hospitalised patients

Result: Nu-DESC sensitivity was 85.7% and specificity 86.8%, values the authors describe as comparable to the longer MDAS; Nu-DESC and DSM-IV sensitivities were similar. The authors concluded Nu-DESC is psychometrically valid and well-suited to widespread clinical use in busy oncology inpatient settings.

Watch out: Derivation population was oncology inpatients and the reference was CAM in 59 ratings — the derivation sensitivity (85.7%) sits well below the later German ward figure (0.98), and the gradient prints rather than being averaged away. The derivation cut-off is not the Italian optimum (next cards).

Source: Gaudreau et al. Fast, systematic, and continuous delirium assessment in hospitalized patients: the nursing delirium screening scale. Journal of pain and symptom management. 2005. PMID: 15857740. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Aged, 80 and over · Cohort Studies · Delirium · Female · Hospitalization · Humans · Male · Mass Screening · Mental Status Schedule · Middle Aged · Nursing Diagnosis · Psychiatric Status Rating Scales · Psychometrics · Reproducibility of Results · Sensitivity and Specificity · Severity of Illness Index · Single-Blind Method

Card 2 — German general-ward validation (Bergjan 2020, N = 698 aged ≥65, DSM-5 reference): Nu-DESC sensitivity 0.98, specificity 0.87, NPV 1.00 — but PPV only 0.43 at a delirium occurrence of 9.0%, so most positive screens were false positives at ward prevalence

Study: Prospective validation in general medical wards (N = 698), DSM-5 reference standard

Population: 698 patients aged 65 and older on general medical wards (two neurology wards and one cardiology ward) of a German tertiary care hospital, assessed during nursing shifts with Nu-DESC and the Delirium Observation Screening Scale (DOS), with delirium diagnosed against DSM-5 criteria by neurologists.

Summary: German general-ward validation (Bergjan 2020, N = 698 aged ≥65, DSM-5 reference): Nu-DESC sensitivity 0.98, specificity 0.87, NPV 1.00 — but PPV only 0.43 at a delirium occurrence of 9.0%, so most positive screens were false positives at ward prevalence

Result: Overall delirium occurrence was 9.0%. For Nu-DESC, sensitivity was 0.98, specificity 0.87, PPV 0.43 and NPV 1.00; for DOS, sensitivity was 0.94, specificity 0.86, PPV 0.40 and NPV 0.99. Predisposing risk factors raised delirium probability (pressure ulcer risk relative OR 17.3; falls risk relative OR 14.0; immobility relative OR 12.7; dementia relative OR 5.38 — relative odds ratios, as published). The authors concluded Nu-DESC is an efficient screening tool that can be integrated into routine care.

Watch out: PPV 0.43 at 9% prevalence is content, not a footnote: a positive Nu-DESC on a general ward is more likely false than true, while NPV 1.00 makes a negative screen the informative direction. This record carries no MeSH terms in PubMed ('none in the record' on its source line).

Source: Bergjan et al. Validation of two nurse-based screening tools for delirium in elderly patients in general medical wards. BMC nursing. 2020. PMID: 32760215. Registry ID: none in the record. MeSH: none in the record

Card 3 — Italian validation (Spedale 2017, N = 101 hospitalised elderly, CAM reference): inter-rater kappa 0.87 and AUC 0.946, with the optimum at a cut-off of 3 — not the derivation cut-off — giving sensitivity 100% and specificity 76%

Study: Translation and validation study, Italian Nu-DESC in hospitalised elderly patients, CAM reference standard

Population: 101 hospitalised elderly patients admitted to wards of the San Gerardo Hospital in Monza, Italy, assessed with the Italian translation of Nu-DESC (translation and back-translation), with inter-rater reliability tested in 20 patients rated concurrently by two examiners and accuracy measured against the Confusion Assessment Method (CAM).

Summary: Italian validation (Spedale 2017, N = 101 hospitalised elderly, CAM reference): inter-rater kappa 0.87 and AUC 0.946, with the optimum at a cut-off of 3 — not the derivation cut-off — giving sensitivity 100% and specificity 76%

Result: Inter-rater reliability was Cohen's kappa 0.87. The ROC curve gave an AUC of 0.9461. Using 3 as the cut-off value, Nu-DESC showed sensitivity 100% and specificity 76%, and the authors identified 3 as the optimal cut-off in the Italian context, calling for further research in larger samples.

Watch out: The cut-off disagreement is the finding: sensitivity 100% / specificity 76% belongs to a cut-off of 3 in this sample and may not be quoted as the performance of the derivation cut-off. The reliability subsample was 20 patients.

Source: Spedale et al. Delirium assessment in hospitalized elderly patients: Italian translation and validation of the nursing delirium screening scale. Aging clinical and experimental research. 2017. PMID: 27568017. Registry ID: none in the record. MeSH: Aged · Aged, 80 and over · Comorbidity · Delirium · Female · Hospitalization · Humans · Italy · Male · Mental Status Schedule · Nursing Assessment · ROC Curve · Reproducibility of Results · Surveys and Questionnaires · Translations

Card 4 — Synthesis: Nu-DESC sensitivity was 85.7% at derivation (oncology inpatients, CAM reference; originators' report), 0.98 on German general medical wards (DSM-5 reference; PPV only 0.43 at 9% prevalence) and 100% in the Italian validation — but only at a cut-off of 3 rather than the derivation cut-off, with specificity 76%

Study: Synthesis

Population: All reports carded on this shelf: derivation (146 patients, oncology units), German ward validation (698 patients aged ≥65) and Italian validation (101 hospitalised elderly patients) — each with its own reference standard (CAM, DSM-5, CAM) printed on its card and never pooled into one accuracy pair.

Summary: Synthesis: Nu-DESC sensitivity was 85.7% at derivation (oncology inpatients, CAM reference; originators' report), 0.98 on German general medical wards (DSM-5 reference; PPV only 0.43 at 9% prevalence) and 100% in the Italian validation — but only at a cut-off of 3 rather than the derivation cut-off, with specificity 76%

Result: A negative Nu-DESC is the strong direction (NPV 1.00 in the largest validation); a positive screen at ward prevalence is more often false than true, and the operating cut-off is not settled between studies. This is a diagnostic-accuracy shelf: no card claims screening changes outcomes.

Watch out: See the individual cards for each report's limits; this synthesis adds no new data.

Source: Synthesis of the reports carded above; no additional source.