SourceMed · Shelf #7754 in the ask interface

Capillary refill time in adults: pooled prognostic accuracy is poor (AUC 0.66, sensitivity 54%), unaided visual assessment shows no agreement with image-derived CRT (κ = 0.00), and quantitative CRT crosses the 3-s threshold in both directions during one inflammatory episode

Shelf #7754 · Critical care & sepsis

PREDICTIVE PERFORMANCE — NOT ESTABLISHED as a stand-alone prognostic test: pooled AUC 0.66 (sensitivity 54%, specificity 72%) for death in acute circulatory failure in the one labelled synthesis (23 studies, 60,656 patients), not significantly different from lactate; single-centre AUCs of 0.84–0.90 (N = 59) do not override the pooled figure, unaided visual CRT showed no agreement with image-derived CRT (κ = 0.00), and quantitative CRT crossed the 3-s threshold in both directions in a healthy-volunteer endotoxemia model; a measurement / prognostic stamp, not a treatment stamp

Stamped: 2026-11-28.

Evidence published: 2014–2026.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

At the bedside, what is capillary refill time (CRT) worth as a perfusion measure in adults — how well does a prolonged CRT predict death or adverse events in acute circulatory failure (and how does it compare with lactate), how much of its unreliability is removed by a standardised timed technique, and what does a controlled human endotoxemia study show about the behaviour of quantitative CRT and its 3-second threshold during acute inflammation?

Balance of the evidence

MEASUREMENT / PROGNOSTIC PERFORMANCE — poor pooled accuracy is the headline, not a caveat. One synthesis is carded beside three primary reports, labelled as such: across 23 studies and 60,656 patients, prolonged CRT predicted death in acute circulatory failure with pooled AUC 0.66, sensitivity 54% and specificity 72% (pooled AUC 0.69 across all at-risk / confirmed-failure analyses), not significantly different from lactate, with accuracy greater when CRT measurement was high-quality. A single-centre septic-shock cohort found much higher AUCs (0.84 index finger, 0.90 knee at 6 hours) — never printed without the pooled figure beside them. Technique moves the value materially: unaided visual CRT showed no agreement with image-derived CRT (κ = 0.00), while a chronograph-standardised method correlated strongly (r = 0.64). And in a controlled human endotoxemia study, quantitative CRT crossed the 3-second threshold in both directions within one inflammatory episode. No card implies CRT-targeted resuscitation improves outcomes — the ANDROMEDA-SHOCK programme asks that different question and is deliberately not carded here.

MeSH: Humans · Adult · Prognosis · Hemodynamics · Shock · Odds Ratio

Cards (5)

Card 1 — Synthesis carded beside primaries, labelled (Jacquet-Lagrèze 2023 — systematic review and meta-analysis, 23 studies, 60,656 patients): for death in acute circulatory failure, pooled AUC 0.66 (95% CI 0.59 to 0.76), sensitivity 54%, specificity 72% and diagnostic odds ratio 3.4 (95% CI 1.4 to 8.3); pooled AUC 0.69 across all at-risk / confirmed-failure analyses; prognostic value not significantly different from lactate

Study: Systematic review and meta-analysis of CRT prognostic value in adults (labelled synthesis, carded beside primary reports)

Population: Adults at risk of or with confirmed acute circulatory failure in 23 studies totalling 60,656 patients (13 studies in the primary analysis of death in acute circulatory failure), drawn from MEDLINE, EMBASE and Google Scholar.

Summary: Synthesis carded beside primaries, labelled (Jacquet-Lagrèze 2023 — systematic review and meta-analysis, 23 studies, 60,656 patients): for death in acute circulatory failure, pooled AUC 0.66 (95% CI 0.59 to 0.76), sensitivity 54%, specificity 72% and diagnostic odds ratio 3.4 (95% CI 1.4 to 8.3); pooled AUC 0.69 across all at-risk / confirmed-failure analyses; prognostic value not significantly different from lactate

Result: Primary analysis: pooled AUC 0.66 (95% CI 0.59 to 0.76), pooled sensitivity 54% (95% CI 43 to 64), pooled specificity 72% (95% CI 55 to 84) and pooled diagnostic odds ratio 3.4 (95% CI 1.4 to 8.3) — a relative odds measure, labelled as such. Secondary analysis across all 23 studies: pooled AUC 0.69 (95% CI 0.65 to 0.74). CRT's prognostic value compared with lactate was not significantly different, and high-quality CRT measurement was associated with greater accuracy. The authors concluded CRT poorly predicted death and adverse events.

Watch out: This is the shelf's one synthesis, not a fourth primary cohort — it is labelled as such and its pooled figures govern the balance. A sensitivity of 54% means a normal CRT misses nearly half of deaths; the single-centre AUCs on the next card may not be read without this pooled figure beside them.

Source: Jacquet-Lagrèze et al. Prognostic value of capillary refill time in adult patients: a systematic review with meta-analysis. Critical care (London, England). 2023. PMID: 38042855. Registry ID: none in the record. MeSH: Humans · Adult · Prognosis · Hemodynamics · Shock · Odds Ratio

Card 2 — Septic-shock cohort (Ait-Oufella 2014, N = 59 after initial resuscitation): 6-hour CRT predicted 14-day mortality with AUC 84% (index finger) and 90% (knee); index threshold 2.4 s gave sensitivity 82% and specificity 73%, knee threshold 4.9 s sensitivity 82% and specificity 84%; inter-rater concordance 80% (index) and 95% (knee)

Study: Prospective observational cohort in septic shock (single centre, N = 59)

Population: 59 consecutive patients with septic shock in a tertiary teaching hospital, assessed after initial resuscitation at 6 hours (H6); median SOFA 10, SAPS II 61, and 14-day mortality 36%. CRT was measured on the index fingertip and the knee.

Summary: Septic-shock cohort (Ait-Oufella 2014, N = 59 after initial resuscitation): 6-hour CRT predicted 14-day mortality with AUC 84% (index finger) and 90% (knee); index threshold 2.4 s gave sensitivity 82% and specificity 73%, knee threshold 4.9 s sensitivity 82% and specificity 84%; inter-rater concordance 80% (index) and 95% (knee)

Result: CRT was higher in non-survivors than survivors at both sites (index 5.6 ± 3.5 vs 2.3 ± 1.8 s; knee 7.6 ± 4.6 vs 2.9 ± 1.7 s; P<0.0001 for both). AUC for 14-day mortality was 84% (index) and 90% (knee); an index threshold of 2.4 s gave sensitivity 82% (95% CI 60 to 95) and specificity 73% (95% CI 56 to 86), and a knee threshold of 4.9 s gave sensitivity 82% and specificity 84% (95% CI 68 to 94). CRT related to arterial lactate and SOFA score, and CRT changes during resuscitation were associated with prognosis.

Watch out: Single-centre, N = 59, one time point (6 hours after resuscitation) and two measurement sites with different thresholds (2.4 s index, 4.9 s knee) — its AUCs of 0.84–0.90 sit far above the pooled 0.66 and are printed only beside it. Site and timing are part of the measurement, not details.

Source: Ait-Oufella et al. Capillary refill time exploration during septic shock. Intensive care medicine. 2014. PMID: 24811942. Registry ID: none in the record. MeSH: Aged · Capillaries · Female · Humans · Lactic Acid · Male · Microcirculation · Predictive Value of Tests · Prognosis · Prospective Studies · Reproducibility of Results · Sensitivity and Specificity · Severity of Illness Index · Shock, Septic · Skin

Card 3 — Standardisation study (Shinozaki 2021, 30 ED patients): unaided visual CRT showed NO agreement with image-derived CRT (κ = 0.00), while a chronograph-standardised visual method correlated strongly with it (r = 0.64, P<0.01), and reliability rose with clinician experience

Study: Cross-sectional standardisation / reliability study in emergency-department patients (N = 30)

Population: 30 patients in an emergency department, assessed by health care providers using unaided visual CRT (method 1), a chronograph-standardised visual CRT by an ED attending (method 2), image-software CRT from video as the criterion standard (method 3), and video-review visual CRT by 9 providers (method 4).

Summary: Standardisation study (Shinozaki 2021, 30 ED patients): unaided visual CRT showed NO agreement with image-derived CRT (κ = 0.00), while a chronograph-standardised visual method correlated strongly with it (r = 0.64, P<0.01), and reliability rose with clinician experience

Result: Standardised visual CRT identified 10 abnormal patients (CRT >2 s) where unaided CRT identified 2. There was no correlation (κ = 0.00) between unaided CRT and image CRT, while standardised visual CRT correlated strongly with image CRT (r = 0.64, P<0.01). Intra-observer reliability and correlation with image CRT were higher for more experienced clinicians reviewing video CRT. The authors concluded a standardised method such as a chronograph, and/or clinical experience, may improve the reliability of visually assessed CRT.

Watch out: κ = 0.00 for the unaided bedside method is the shelf's reliability floor: any CRT figure from an unstandardised visual assessment — including those pooled in the synthesis — carries this caveat. Small study (30 patients); it measures agreement between methods, not prognosis.

Source: Shinozaki et al. The standardized method and clinical experience may improve the reliability of visually assessed capillary refill time. The American journal of emergency medicine. 2021. PMID: 32507474. Registry ID: none in the record. MeSH: Blood Circulation · Capillaries · Cross-Sectional Studies · Female · Hand · Humans · Image Processing, Computer-Assisted · Male · Middle Aged · Reproducibility of Results · Video Recording

Card 4 — Human endotoxemia study (Gustavsson 2026, 25 healthy volunteers, double-blind randomised crossover, E. coli lipopolysaccharide 0.8 ng/kg vs saline): quantitative finger CRT was biphasic — prolonging to 8.31 s at 1.5 h (14 of 25 hitting the 10-s ceiling) then shortening to 1.27 s at 5 h despite persisting inflammation — crossing the 3-s threshold in both directions within one episode; skin temperature was the strongest covariate

Study: Double-blind randomised crossover human endotoxemia challenge study (healthy volunteers, N = 25) — physiological-limits evidence

Population: 25 healthy volunteers in a double-blind randomised crossover study receiving an intravenous bolus of Escherichia coli lipopolysaccharide (0.8 ng/kg) or saline placebo, with finger quantitative CRT measured by polarised reflectance imaging at baseline and 1.5, 3.5 and 5 hours. Registry ID: NCT06618716.

Summary: Human endotoxemia study (Gustavsson 2026, 25 healthy volunteers, double-blind randomised crossover, E. coli lipopolysaccharide 0.8 ng/kg vs saline): quantitative finger CRT was biphasic — prolonging to 8.31 s at 1.5 h (14 of 25 hitting the 10-s ceiling) then shortening to 1.27 s at 5 h despite persisting inflammation — crossing the 3-s threshold in both directions within one episode; skin temperature was the strongest covariate

Result: From a baseline near 3.5 s, quantitative CRT prolonged to 8.31 s at 1.5 h (14 of 25 reaching the 10-s ceiling) then shortened to 1.27 s at 5 h during persisting systemic inflammation; estimated marginal contrasts against placebo were +4.13 s and −3.10 s at those time points (both P<0.0001). Each standard-deviation increase in skin temperature was associated with a 1.62 s decrease in CRT, and between-subject differences explained only a minority of total variance (intraclass correlation 0.30). The authors concluded a single value against a fixed threshold is unreliable, whereas change over time within a participant is informative, and that findings in healthy participants are not directly generalisable to septic shock.

Watch out: A healthy-volunteer challenge model (N = 25), carded as physiological-limits evidence and never pooled with patient cohorts. It tests what a fixed 3-second threshold can mean during inflammation — it does not test CRT's prognostic use in patients, and its authors say so.

Source: Gustavsson et al. Physiological limits of capillary refill time: a human endotoxemia study. Critical care (London, England). 2026. PMID: 42706575. Registry ID: NCT06618716. MeSH: Humans · Endotoxemia · Cross-Over Studies · Double-Blind Method · Female · Adult · Capillaries · Male · Lipopolysaccharides · Fingers · Time Factors · Microcirculation

Card 5 — Synthesis: pooled prognostic accuracy of CRT is poor (AUC 0.66 for death in acute circulatory failure, sensitivity 54%, in one labelled synthesis of 23 studies / 60,656 patients), the best single-centre figures (AUC 0.84–0.90) come from 59 resuscitated septic-shock patients at one time point and two body sites, unaided visual assessment agrees not at all with image-derived CRT (κ = 0.00) while standardisation restores correlation (r = 0.64), and quantitative CRT crosses the 3-s threshold in both directions during one inflammatory episode in healthy volunteers

Study: Synthesis

Population: All reports carded on this shelf: one labelled synthesis (23 studies, 60,656 patients), one septic-shock cohort (N = 59), one ED standardisation study (N = 30 patients) and one healthy-volunteer endotoxemia study (N = 25) — syntheses, patient cohorts and the challenge model kept in their own lanes and never pooled together.

Summary: Synthesis: pooled prognostic accuracy of CRT is poor (AUC 0.66 for death in acute circulatory failure, sensitivity 54%, in one labelled synthesis of 23 studies / 60,656 patients), the best single-centre figures (AUC 0.84–0.90) come from 59 resuscitated septic-shock patients at one time point and two body sites, unaided visual assessment agrees not at all with image-derived CRT (κ = 0.00) while standardisation restores correlation (r = 0.64), and quantitative CRT crosses the 3-s threshold in both directions during one inflammatory episode in healthy volunteers

Result: CRT's worth at the bedside is technique-, site-, temperature- and time-dependent, and weak as a stand-alone prognostic test on the pooled evidence. No card on this shelf addresses CRT-targeted resuscitation; that intervention question (the ANDROMEDA-SHOCK programme) is deliberately not carded here.

Watch out: See the individual cards for each report's limits; this synthesis adds no new data.

Source: Synthesis of the reports carded above; no additional source.