SourceMed · Shelf #7756 in the ask interface

SARC-F sarcopenia screening (3 syntheses, overlapping primary sets): pooled sensitivity only 0.21–0.39 against most reference definitions beside specificity 86–91% — a negative SARC-F misses most sarcopenia; Ishii (79%) and MSRA (82%) were more sensitive

Shelf #7756 · Geriatrics, frailty & deprescribing

PREDICTIVE PERFORMANCE — NOT ESTABLISHED as a rule-out screen (3 syntheses, overlapping primary sets, counted as syntheses only): pooled SARC-F sensitivity was 0.21 against EWGSOP and 27–39% against AWGS / IWGS / FNIH, beside specificities of 86–91%, and the Ishii score (79%) and MSRA (82%) were more sensitive in head-to-head synthesis; a screening-accuracy stamp, not a treatment stamp

Stamped: 2026-11-28.

Evidence published: 2018–2023.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In older adults, how accurate is the SARC-F questionnaire (five self-reported items; score ≥4 screens positive) as a bedside / clinic screen for sarcopenia — what pooled sensitivity and specificity does it deliver against the EWGSOP, AWGS, IWGS and FNIH reference definitions, and how does it compare with the other screening instruments (Ishii score, MSRA) in head-to-head synthesis? (This shelf rests on 3 syntheses with overlapping primary-study sets, counted as 3 syntheses on its face.)

Balance of the evidence

SCREENING PERFORMANCE — the sensitivity failure is the headline, printed as 3 syntheses, never as independent-cohort support. This shelf rests on three meta-analyses / systematic reviews whose primary-study sets overlap; the count is 3 syntheses, not 3 independent cohorts. Against EWGSOP, pooled SARC-F sensitivity was 0.21 (specificity 0.90) in the 2018 synthesis of 7 studies / 12,800 subjects, and 32% in the 2021 diagnostic meta-analysis of 20 studies — which also showed how criterion-dependent the estimate is (EWGSOP2 77%, AWGS 27%, IWGS 39%, FNIH 35%, specificities 63–91%). The 2023 head-to-head synthesis of five screening tools (42 studies) found SARC-F specificity 87% but the Ishii score combining sensitivity 79% with the best negative likelihood ratio (relative, 0.25) and MSRA reaching sensitivity 82% — SARC-F was not the most sensitive instrument. A negative SARC-F misses most sarcopenia against most criteria and must never be presented as a rule-out test. Pooled figures are criterion-specific and are never merged into one accuracy pair. No grip-strength data is carded on this shelf. This is a screening-accuracy shelf: no card claims SARC-F-triggered pathways improve outcomes.

MeSH: Aged · Aged, 80 and over · Female · Geriatric Assessment · Humans · Japan · Male · Mass Screening · ROC Curve · Sarcopenia · Sensitivity and Specificity · Surveys and Questionnaires

Cards (4)

Card 1 — Synthesis 1 of 3 (Ida 2018 — meta-analysis, 7 studies, 12,800 subjects; overlapping primary sets with the other two syntheses): against EWGSOP, pooled SARC-F sensitivity 0.21 (95% CI 0.13 to 0.31) and specificity 0.90 (95% CI 0.83 to 0.94), positive likelihood ratio 2.16 and diagnostic odds ratio 2.47 (both relative measures, labelled as such), with similar results against IWGS and AWGS

Study: Meta-analysis of screening test accuracy (synthesis 1 of 3 on this shelf; primary-study sets overlap across the three syntheses)

Population: Older adults in 7 studies totalling 12,800 subjects, pooled in a meta-analysis of SARC-F screening test accuracy against the European Working Group on Sarcopenia in Older People (EWGSOP), International Working Group on Sarcopenia (IWGS) and Asian Working Group for Sarcopenia (AWGS) reference standards; too few studies used the Foundation NIH (FNIH) standard for meta-analysis.

Summary: Synthesis 1 of 3 (Ida 2018 — meta-analysis, 7 studies, 12,800 subjects; overlapping primary sets with the other two syntheses): against EWGSOP, pooled SARC-F sensitivity 0.21 (95% CI 0.13 to 0.31) and specificity 0.90 (95% CI 0.83 to 0.94), positive likelihood ratio 2.16 and diagnostic odds ratio 2.47 (both relative measures, labelled as such), with similar results against IWGS and AWGS

Result: Against EWGSOP, pooled sensitivity was 0.21 (95% CI 0.13 to 0.31), specificity 0.90 (95% CI 0.83 to 0.94), positive likelihood ratio 2.16 (95% CI 1.51 to 3.09), negative likelihood ratio 0.87 (95% CI 0.80 to 0.95) and diagnostic odds ratio 2.47 (95% CI 1.64 to 3.74) — likelihood ratios and the odds ratio are relative measures, labelled as such. Similar pooled sensitivity and specificity were found against IWGS and AWGS. The authors concluded SARC-F's screening sensitivity was poor but its specificity high, making it a tool for selecting subjects for further confirmatory testing.

Watch out: One of 3 syntheses with overlapping primary studies — never counted as independent-cohort support for the other two. Sensitivity 0.21 means roughly four of five people with EWGSOP sarcopenia screen negative; that is the card's headline, not its caveat.

Source: Ida et al. SARC-F for Screening of Sarcopenia Among Older Adults: A Meta-analysis of Screening Test Accuracy. Journal of the American Medical Directors Association. 2018. PMID: 29778639. Registry ID: none in the record. MeSH: Aged · Aged, 80 and over · Female · Geriatric Assessment · Humans · Japan · Male · Mass Screening · ROC Curve · Sarcopenia · Sensitivity and Specificity · Surveys and Questionnaires

Card 2 — Synthesis 2 of 3 (Lu 2021 — diagnostic meta-analysis, 20 studies; overlapping primary sets): pooled SARC-F sensitivity by criterion was EWGSOP 32%, EWGSOP2 77%, AWGS 27%, IWGS 39% and FNIH 35%, with specificities 63–91% — the criterion-dependence of the sensitivity estimate is itself a finding

Study: Diagnostic meta-analysis (synthesis 2 of 3 on this shelf; primary-study sets overlap across the three syntheses)

Population: Adults aged 60 years and older in 20 studies (sarcopenia prevalence 6.42% to 21.56%), pooled against five reference definitions — EWGSOP (13 studies), EWGSOP2 (4), AWGS (13), IWGS (8) and FNIH (7) — using bivariate and hierarchical summary ROC modelling.

Summary: Synthesis 2 of 3 (Lu 2021 — diagnostic meta-analysis, 20 studies; overlapping primary sets): pooled SARC-F sensitivity by criterion was EWGSOP 32%, EWGSOP2 77%, AWGS 27%, IWGS 39% and FNIH 35%, with specificities 63–91% — the criterion-dependence of the sensitivity estimate is itself a finding

Result: Pooled sensitivity / specificity by criterion: EWGSOP 32% (95% CI 19 to 47) / 86% (77 to 92); EWGSOP2 77% (49 to 92) / 63% (43 to 79); AWGS 27% (16 to 42) / 91% (85 to 95); IWGS 39% (27 to 52) / 86% (76 to 92); FNIH 35% (23 to 49) / 89% (81 to 93). Areas under the hierarchical summary ROC curve ran 0.67 to 0.75 by criterion. The authors concluded SARC-F's screening accuracy varies by diagnostic criteria, while noting its practicability and specificity, and that accuracy under EWGSOP2 needs further exploration.

Watch out: The EWGSOP2 sensitivity (77%) comes from only 4 studies with a wide interval (49–92%) and a much lower specificity (63%) — it may not be quoted as 'SARC-F sensitivity is 77%' without its criterion, study count and specificity beside it. Each criterion defines a different sarcopenia; the pairs are never merged.

Source: Lu et al. Screening Accuracy of SARC-F for Sarcopenia in the Elderly: A Diagnostic Meta-Analysis. The journal of nutrition, health & aging. 2021. PMID: 33491031. Registry ID: none in the record. MeSH: Aged · Aged, 80 and over · Female · Humans · Male · Mass Screening · Prevalence · Sarcopenia

Card 3 — Synthesis 3 of 3 (Huang 2023 — systematic review and meta-analysis of five sarcopenia screening tools, 42 studies; overlapping primary sets): SARC-F specificity 87% (95% CI 82 to 90), while the Ishii score combined sensitivity 79% with the best negative likelihood ratio (relative, 0.25) and MSRA reached sensitivity 82% — SARC-F was not the most sensitive instrument in the comparison

Study: Systematic review and meta-analysis of screening instruments (synthesis 3 of 3 on this shelf; primary-study sets overlap across the three syntheses)

Population: 42 studies of five sarcopenia screening tools, identified from 7,120 screened titles and abstracts, with study quality assessed by QUADAS-2 (moderate to good) and measurement properties by the COSMIN checklist.

Summary: Synthesis 3 of 3 (Huang 2023 — systematic review and meta-analysis of five sarcopenia screening tools, 42 studies; overlapping primary sets): SARC-F specificity 87% (95% CI 82 to 90), while the Ishii score combined sensitivity 79% with the best negative likelihood ratio (relative, 0.25) and MSRA reached sensitivity 82% — SARC-F was not the most sensitive instrument in the comparison

Result: Three instruments had specificities of 85% or more: the modified SARC-F 92% (95% CI 63 to 99), SARC-F 87% (95% CI 82 to 90) and the Ishii score 85% (95% CI 77 to 90). Three tools had sensitivities of 75% or more: MSRA 82% (95% CI 69 to 90), the Ishii score 79% (95% CI 62 to 89) and U-TEST 76%. Positive likelihood ratios above 5.0 (relative measures) were present for the Ishii score and modified SARC-F, and the Ishii score had the best negative likelihood ratio, 0.25. The authors concluded MSRA and the Ishii score had excellent sensitivity for early screening, while modified SARC-F and the Ishii score had superior specificity.

Watch out: Head-to-head figures come from pooling across different study sets per instrument, not from within-study comparisons alone — read as a synthesis-level comparison. SARC-F's own sensitivity is not pooled in this report's abstract; its specificity (87%) is the SARC-F number here.

Source: Huang et al. The accuracy of screening instruments for sarcopenia: a diagnostic systematic review and meta-analysis. Age and ageing. 2023. PMID: 37596923. Registry ID: none in the record. MeSH: Humans · Sarcopenia · Checklist · Consensus

Card 4 — Synthesis: on 3 syntheses (counted as 3 syntheses with overlapping primary-study sets, never as independent cohorts), SARC-F is a specific but insensitive sarcopenia screen — pooled sensitivity 0.21 against EWGSOP (2018) and 27–39% against AWGS / IWGS / FNIH (2021), beside specificities of 86–91% — and in head-to-head synthesis the Ishii score (sensitivity 79%, best negative likelihood ratio 0.25) and MSRA (sensitivity 82%) were more sensitive; a negative SARC-F misses most sarcopenia and is not a rule-out

Study: Synthesis

Population: All reports carded on this shelf: 3 syntheses only — 7 studies / 12,800 subjects (2018), 20 studies (2021) and 42 studies across five screening tools (2023) — with overlapping primary-study sets, stated on the face as the standing labelling for this shelf.

Summary: Synthesis: on 3 syntheses (counted as 3 syntheses with overlapping primary-study sets, never as independent cohorts), SARC-F is a specific but insensitive sarcopenia screen — pooled sensitivity 0.21 against EWGSOP (2018) and 27–39% against AWGS / IWGS / FNIH (2021), beside specificities of 86–91% — and in head-to-head synthesis the Ishii score (sensitivity 79%, best negative likelihood ratio 0.25) and MSRA (sensitivity 82%) were more sensitive; a negative SARC-F misses most sarcopenia and is not a rule-out

Result: The defensible use on this evidence is as a specific first filter selecting people for confirmatory testing, not as a rule-out. No primary cohort is carded, no grip-strength data is carded, and no card claims that SARC-F-triggered pathways improve outcomes.

Watch out: See the individual cards for each synthesis's limits; this synthesis adds no new data.

Source: Synthesis of the reports carded above; no additional source.