SourceMed · Shelf #7805 in the ask interface

NIH Stroke Scale reliability between raters: a respectable total-score ICC of 0.85 beside a clinically material spread — total scores varied by four or more points in 64% of certification vignettes, and the ataxia item's kappa was 0.15

Shelf #7805 · Brain, stroke & mind

PREDICTIVE PERFORMANCE — reliability split between the total score and its items: total-score intraclass correlation 0.85 (95% CI 0.72–0.90) in the DVD certification validation, BUT the 5th-to-95th percentile spread of total scores was four or more points for 7 of 11 videotaped patients (64%), item kappas ranged from 0.15 (ataxia) to 0.81 (level-of-consciousness commands), and repeat examination did not improve agreement. Two of the three anchors score videotaped/DVD standardised patients, not live bedside examinations; the derivation-era study rated 20 patients. No card may print the ICC without the spread

Stamped: 2026-11-28.

Evidence published: 1989–2009.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

At the bedside, how reliable is the NIH Stroke Scale (NIHSS — 15 items: consciousness, gaze, visual fields, facial palsy, arm and leg motor, ataxia, sensory, language, dysarthria, extinction/inattention) between raters — what inter-rater agreement did its first reliability study find item by item, how wide is the spread of total scores when thousands of clinicians rate the same standardised patients for certification, and which items drive the disagreement?

Balance of the evidence

This is a measurement-reliability shelf, not a prognostic or treatment shelf: no card may convert reliability data into claims about thrombolysis or thrombectomy thresholds. The content is the split. On one side, the total score looks respectable: in the DVD certification validation among general users (8,214 raters), the intraclass correlation coefficient for the total score was 0.85 (95% CI 0.72–0.90), with 11 of 15 items showing moderate agreement and 2 excellent. On the other side, the spread is clinically material: in the large videotape certification analysis (7,405 unique raters, 38,148 item responses), total scores for 7 of 11 patients (64%) had a 5th-to-95th percentile spread of four or more points; the aphasia (kappa 0.60) and facial palsy (0.65) items contributed most to the variance; and taking the examination repeatedly did not improve agreement. Item-level weakness is specific: kappas ranged from 0.15 (ataxia — poor) to 0.81 (level-of-consciousness commands). The first reliability study (1989; 20 stroke patients, each rated by a pair of four clinical stroke fellows — its N prints on the face) found moderate-to-substantial agreement for 9 of 13 items; its abstract reports agreement qualitatively by item, and no pooled kappa may be printed from it. Two of the three anchors measure scoring of videotaped/DVD standardised patients, not live bedside examinations, and print as such — live-examination reliability could differ in either direction and is not what these numbers measure.

MeSH: Cerebrovascular Disorders/physiopathology · Humans · National Institutes of Health (U.S.) · Severity of Illness Index · Statistics as Topic · United States · Certification · Clinical Trials as Topic/methods · Health Personnel · Medical Laboratory Personnel · Neuropsychological Tests/standards · Nurses · Observer Variation · Physicians · Reproducibility of Results · Social Work · Societies, Medical · Stroke/diagnosis, therapy · Treatment Outcome · Videotape Recording · Software · Stroke/diagnosis, physiopathology

Cards (4)

Card 1 — First reliability study (1989): inter-observer agreement was moderate to substantial for 9 of 13 items — in 20 stroke patients rated by pairs of clinical stroke fellows (the small derivation-era N prints on this shelf's face)

Study: Inter-rater reliability study — derivation-era report (live bedside ratings)

Population: 20 patients who had a stroke, each independently rated with the scale by one pair drawn from four clinical stroke fellows; agreement per item calculated as kappa statistics. The scale was then in use in several multicentre stroke trials.

Summary: First reliability study (1989): inter-observer agreement was moderate to substantial for 9 of 13 items — in 20 stroke patients rated by pairs of clinical stroke fellows (the small derivation-era N prints on this shelf's face)

Result: Inter-observer agreement was moderate to substantial for 9 of 13 items. The authors judged that the rating system compares favourably with other scales for which such comparisons can be made, while noting the validity of the system remained to be established. The abstract reports agreement qualitatively by item — no pooled kappa is printed from this report, and none may be reconstructed.

Watch out: N = 20 patients and four expert fellows: the smallest and most expert sample on this shelf. Never cite this report for a numeric pooled reliability coefficient — its abstract contains none.

Source: Goldstein LB et al. Interrater reliability of the NIH stroke scale. Archives of neurology. 1989. PMID: 2730378. Registry ID: none in the record. MeSH: Cerebrovascular Disorders/physiopathology · Humans · National Institutes of Health (U.S.) · Severity of Illness Index · Statistics as Topic · United States

Card 2 — Videotape certification analysis (2006): total scores varied widely — for 7 of 11 patients (64%) the 5th-to-95th percentile spread of total NIHSS was four or more points; aphasia (kappa 0.60) and facial palsy (0.65) contributed most to the variance, and repeat examination did not improve agreement

Study: Certification-examination reliability analysis — videotaped standardised patients (not live bedside examinations)

Population: Analysis of the standard videotaped certification examination (1998–2004): 7,405 unique raters (clinicians of several professions) contributing 38,148 individual item responses across standardised videotaped patients whose median scores ranged from 0 to 31.

Summary: Videotape certification analysis (2006): total scores varied widely — for 7 of 11 patients (64%) the 5th-to-95th percentile spread of total NIHSS was four or more points; aphasia (kappa 0.60) and facial palsy (0.65) contributed most to the variance, and repeat examination did not improve agreement

Result: Total NIHSS scores varied widely between raters: scoring for 7 of the 11 patients (64%) showed a difference of four or more points between the 5th and 95th percentiles. The aphasia and facial palsy items contributed most to the variance in total score. Nurses agreed with the most common response more frequently than physicians (P < 0.0001). Taking the certification examination multiple times did not improve agreement. The authors conclude overall scoring was inconsistent and could impact clinical trial results.

Watch out: These are ratings of videotapes, not live patients — printed as such. A ≥4-point total-score spread is clinically material at treatment-threshold scores, but this shelf makes no treatment-threshold claim; it reports the measurement property.

Source: Josephson SA et al. NIH Stroke Scale reliability in ratings from a large sample of clinicians. Cerebrovascular diseases (Basel, Switzerland). 2006. PMID: 16888381. Registry ID: none in the record. MeSH: Certification · Clinical Trials as Topic/methods · Health Personnel · Humans · Medical Laboratory Personnel · National Institutes of Health (U.S.) · Neuropsychological Tests/standards · Nurses · Observer Variation · Physicians · Reproducibility of Results · Severity of Illness Index · Social Work · Societies, Medical · Stroke/diagnosis, therapy · Treatment Outcome · United States · Videotape Recording

Card 3 — DVD certification validation among general users (2009): item kappas ranged from 0.15 (ataxia) to 0.81 (level-of-consciousness commands), 11 of 15 items moderate and 2 excellent — and the intraclass correlation coefficient for the total score was 0.85 (95% CI 0.72–0.90)

Study: Certification validation — DVD standardised patients rated by general users (not live bedside examinations)

Population: Validation of the standard NIHSS training/certification DVD (18 patients spanning all scores on 15 items) among general (non-expert) users: 8,214 raters overall (7,419 via the internet, 795 via other venues); 51% previously NIHSS-certified; nurses, emergency physicians and neurologists all represented.

Summary: DVD certification validation among general users (2009): item kappas ranged from 0.15 (ataxia) to 0.81 (level-of-consciousness commands), 11 of 15 items moderate and 2 excellent — and the intraclass correlation coefficient for the total score was 0.85 (95% CI 0.72–0.90)

Result: Unweighted item kappas ranged from 0.15 (ataxia) to 0.81 (Item 1c, level-of-consciousness commands); of 15 items, 2 showed poor, 11 moderate and 2 excellent agreement. The intraclass correlation coefficient for the total score was 0.85 (95% CI 0.72 to 0.90). Agreement was slightly lower than among expert users for several items (level-of-consciousness, best gaze, visual fields, facial weakness, motor arms, sensory loss); scores were similar across specialties and venues, tending lower for neurologists and higher among raters not previously certified.

Watch out: BINDING: the ICC of 0.85 may never be printed without the spread evidence (card 2) and the weak items (ataxia κ 0.15). DVD vignettes, not live examinations.

Source: Lyden P et al. National Institutes of Health Stroke Scale certification is reliable across multiple venues. Stroke. 2009. PMID: 19520998. Registry ID: none in the record. MeSH: Certification · Humans · National Institutes of Health (U.S.) · Reproducibility of Results · Severity of Illness Index · Software · Stroke/diagnosis, physiopathology · United States

Card 4 — Synthesis: the NIHSS total score is reproducible in aggregate (ICC 0.85) while individual total scores commonly differ by four or more points and specific items (ataxia, aphasia, facial palsy) drive the disagreement

Study: Synthesis

Population: Three reports: the derivation-era live-rating study (20 patients, 4 fellows), the videotape certification analysis (7,405 raters) and the DVD certification validation (8,214 raters). Two of the three score standardised recorded patients, not live bedside examinations.

Summary: Synthesis: the NIHSS total score is reproducible in aggregate (ICC 0.85) while individual total scores commonly differ by four or more points and specific items (ataxia, aphasia, facial palsy) drive the disagreement

Result: Item agreement in 1989 was moderate to substantial for 9 of 13 items (qualitative only). At certification scale, total-score reliability is respectable by ICC (0.85) yet the 5th–95th percentile total-score spread reached ≥4 points in 64% of vignettes, repeat testing did not help, and ataxia (κ 0.15) is a near-unreliable item while level-of-consciousness commands (κ 0.81) anchor the scale.

Watch out: Reliability only — nothing here speaks to prognosis or to any treatment threshold, and no card converts it into one.

Source: Synthesis of the reports carded above; no additional source.