SourceMed · Shelf #7813 in the ask interface

Whispered voice test for hearing impairment: adult sensitivity 90–100% in the systematic review, phrase-dependent AUCs 0.900–0.918 in older adults, and tuning-fork tests not supported for screening

Shelf #7813 · Eyes, skin, nose & allergy

PREDICTIVE PERFORMANCE — sensitive bedside screen, technique unstandardised: adult sensitivity 90–100% across 4 studies in the 2003 review (a range, not a pooled estimate), summary positive / negative likelihood ratios 6.1 / 0.03 in the Rational Clinical Examination, best phrases AUC 0.900–0.918 in older adults; tuning-fork tests NOT supported for general screening (Weber likelihood ratio 1.6); a screening-accuracy stamp, not a treatment stamp

Stamped: 2026-11-28.

Evidence published: 2003–2017.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

At the bedside, how accurately does the whispered voice test (examiner whispers a letter / number combination or short phrases at arm's length behind the patient, masking the other ear) detect hearing impairment against pure-tone audiometry — what sensitivity and specificity ranges did the systematic review find in adults, what accuracy and inter-examiner reproducibility do standardised phrases achieve in older adults, and what summary likelihood ratios does the Rational Clinical Examination assign to the whispered voice and to the Rinne and Weber tuning-fork tests?

Balance of the evidence

Technique is unstandardised across the primary literature (six techniques in the 2003 systematic review; phrase choice moves the AUC in the older-adult study) and prints on this shelf. The adult sensitivity headline (90–100%) comes from four studies inside the 2003 review and prints as a range from a synthesis, not as a pooled estimate. The Rational Clinical Examination gives the whispered voice a summary positive likelihood ratio of 6.1 and negative likelihood ratio of 0.03 (both labelled as such), while the tuning-fork limb is a negative result — Weber likelihood ratio 1.6, near 1 — and prints as such, not as an endorsement of Rinne / Weber screening. This is a screening-accuracy shelf, not a treatment shelf.

MeSH: Adult · Child · Child, Preschool · Hearing Disorders/diagnosis · Hearing Tests/methods,standards · Humans · Middle Aged · Reproducibility of Results · Sensitivity and Specificity

Cards (4)

Card 1 — Whispered voice systematic review (Pirozzo 2003, BMJ — 8 studies using six different techniques): in the four adult studies sensitivity was 90% or 100% and specificity 70–87%; in the four childhood studies sensitivity ranged 80–96% and specificity 90–98%, against pure-tone audiometry

Study: Systematic review of test accuracy (8 studies, six techniques)

Population: Cross-sectional accuracy studies of the whispered voice test with audiometry performed on at least 80% of participants; 8 studies, six different techniques — 4 in adults, 4 in children.

Summary: Whispered voice systematic review (Pirozzo 2003, BMJ — 8 studies using six different techniques): in the four adult studies sensitivity was 90% or 100% and specificity 70–87%; in the four childhood studies sensitivity ranged 80–96% and specificity 90–98%, against pure-tone audiometry

Result: Adult studies: sensitivity 90% or 100%, specificity 70% to 87%. Childhood studies: sensitivity 80% to 96%, specificity 90% to 98%. The reviewers call the test simple and accurate for detecting hearing impairment, with concern about lower sensitivity in children and overall reproducibility, particularly in primary care, and call for standardisation studies in primary care.

Watch out: The adult 90–100% sensitivity is a range across four studies using different techniques, not a pooled estimate — no card may present it as one.

Source: Pirozzo S et al. Whispered voice test for screening for hearing impairment in adults and children: systematic review. BMJ (Clinical research ed.). 2003. PMID: 14576249. Registry ID: none in the record. MeSH: Adult · Child · Child, Preschool · Hearing Disorders/diagnosis · Hearing Tests/methods,standards · Humans · Middle Aged · Reproducibility of Results · Sensitivity and Specificity

Card 2 — Standardised whispered phrases in older adults (Labanca 2017 — 210 adults aged 60–97 against audiometry): the best-performing phrases reached AUCs of 0.900–0.918 with inter-examiner reproducibility 0.81–0.877

Study: Cross-sectional accuracy and reproducibility study in older adults (N = 210)

Population: 210 older adults aged 60–97 years; whispered voice test employing ten different phrases, audiometry as reference; the test was repeated on 20% of ears by a second examiner for inter-examiner reproducibility.

Summary: Standardised whispered phrases in older adults (Labanca 2017 — 210 adults aged 60–97 against audiometry): the best-performing phrases reached AUCs of 0.900–0.918 with inter-examiner reproducibility 0.81–0.877

Result: The words and phrases with the highest AUC and reproducibility were 'shoe' (AUC 0.918; reproducibility 0.877), 'window' (AUC 0.917; 0.869), 'it looks like it's going to rain' (AUC 0.911; 0.810) and 'the bus is late' (AUC 0.900; 0.810). The authors conclude the whispered voice test is a useful screening tool in older people and propose these phrases be incorporated into the protocol.

Watch out: Journal note: the slate row named the Brazilian Journal of Otorhinolaryngology; the PubMed record fetched gives Ciencia & saude coletiva — the record governs the source line. Phrase choice is part of the result: accuracy is phrase-dependent, not a property of whispering in general.

Source: Labanca L et al. Screening of hearing in elderly people: assessment of accuracy and reproducibility of the whispered voice test. Ciencia & saude coletiva. 2017. PMID: 29211164. Registry ID: none in the record. MeSH: Aged · Cross-Sectional Studies · Female · Hearing · Hearing Tests/methods · Humans · Male · Mass Screening/methods · Middle Aged · Presbycusis/diagnosis,epidemiology · Prevalence · Quality of Life · Reproducibility of Results · Sensitivity and Specificity

Card 3 — Rational Clinical Examination on bedside hearing manoeuvres (Bagai 2006, JAMA — 24 studies): inability to perceive a whispered voice had a summary positive likelihood ratio of 6.1 (95% CI 4.5 to 8.4) and normal perception a negative likelihood ratio of 0.03 (0 to 0.24), both labelled as such; an abnormal Weber test had a likelihood ratio of only 1.6 (1.0 to 2.3) and Rinne results varied too widely to summarise simply (positive likelihood ratios 2.7 to 62)

Study: Rational Clinical Examination systematic review (24 studies)

Population: Original studies of the accuracy or precision of screening questions and bedside tests for hearing impairment, 1966 to April 2005; 24 included studies, each assigned a methodological grade.

Summary: Rational Clinical Examination on bedside hearing manoeuvres (Bagai 2006, JAMA — 24 studies): inability to perceive a whispered voice had a summary positive likelihood ratio of 6.1 (95% CI 4.5 to 8.4) and normal perception a negative likelihood ratio of 0.03 (0 to 0.24), both labelled as such; an abnormal Weber test had a likelihood ratio of only 1.6 (1.0 to 2.3) and Rinne results varied too widely to summarise simply (positive likelihood ratios 2.7 to 62)

Result: Whispered voice: positive likelihood ratio 6.1 (95% CI 4.5 to 8.4) for inability to perceive, negative likelihood ratio 0.03 (0 to 0.24) for normal perception. Weber: abnormal response likelihood ratio 1.6 (1.0 to 2.3), normal 0.70 (0.48 to 1.0). Rinne: abnormal response likelihood ratios ranged 2.7 to 62, normal 0.01 to 0.85. The reviewers advise that people who perceive the whispered voice need no further testing, those who cannot require audiometry, and that the Weber and Rinne tests should not be used for general screening.

Watch out: The tuning-fork limb is negative for screening (Weber likelihood ratio near 1) and prints as such. The whispered-voice likelihood ratios are summary values from a synthesis, labelled as such, not a single cohort's result.

Source: Bagai A et al. Does this patient have hearing impairment? JAMA. 2006. PMID: 16434632. Registry ID: none in the record. MeSH: Aged · Hearing Loss/diagnosis,physiopathology · Hearing Tests/methods · Humans

Card 4 — Synthesis: the whispered voice test is a sensitive bedside screen in adults (90–100% sensitivity across four studies in the 2003 review; summary negative likelihood ratio 0.03 in the Rational Clinical Examination), with phrase-dependent accuracy in older adults — while Rinne / Weber tuning-fork tests are not supported for general screening. Refusal recorded: the 1985 primary study of the test (PMID 3989786) has no abstract in its PubMed record and was therefore NOT carded as an anchor on this shelf

Study: Synthesis

Population: All reports carded on this shelf: Pirozzo 2003 systematic review (8 studies), Labanca 2017 older-adult study (N = 210) and Bagai 2006 Rational Clinical Examination review (24 studies). Refusal: PMID 3989786 (1985 primary study) — no abstract in PubMed, not carded; absence of an abstract is not absence of the paper.

Summary: Synthesis: the whispered voice test is a sensitive bedside screen in adults (90–100% sensitivity across four studies in the 2003 review; summary negative likelihood ratio 0.03 in the Rational Clinical Examination), with phrase-dependent accuracy in older adults — while Rinne / Weber tuning-fork tests are not supported for general screening. Refusal recorded: the 1985 primary study of the test (PMID 3989786) has no abstract in its PubMed record and was therefore NOT carded as an anchor on this shelf

Result: The evidence supports the whispered voice as a screening manoeuvre whose technique is not standardised, and does not support tuning-fork tests for general screening. No card extends these figures beyond hearing screening against audiometry, and no card implies a screening pathway improves outcomes.

Watch out: See the individual cards for each report's limits; this synthesis adds no new data.

Source: Synthesis of the reports carded above; no additional source.