Bedside examination for ascites — FLOOR-RISK, exactly 2 reports: composite clinical evaluation strongly discriminative when suggestive, individual manoeuvres weak, overall accuracy 58% in the small referred study

Shelf #7814 · Liver & gut

PREDICTIVE PERFORMANCE — FLOOR-RISK, exactly 2 reports: prospective evaluation (N not documented) composite positive likelihood ratio 37.7–83.3 when suggestive, against overall accuracy only 58% in the referred study (N = 21, only 6 with ascites); individual manoeuvres weak in both reports; a diagnostic-accuracy stamp, not a treatment stamp

Stamped: 2026-11-28.

Evidence published: 1982–1988.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In hospitalised patients with suspected ascites, how accurately do the bedside history and physical-examination findings — bulging flanks, flank dullness and its shifting, a fluid wave / thrill, peripheral oedema, and the patient's own report of increasing abdominal girth and weight gain — detect ascites against ultrasonography: what likelihood ratios did the prospective evaluation assign to each finding and to the overall clinical evaluation, and how accurate were the individual manoeuvres in the small referred-patient study in which only six patients actually had ascites? (FLOOR-RISK base: exactly 2 reports — one with N not documented in its abstract, one with N = 21 and only 6 positive cases.)

Balance of the evidence

FLOOR-RISK — this shelf rests on exactly 2 abstract-verifiable reports, and that exact basis prints here and on every card: a prospective evaluation whose abstract does not state its cohort size (N not documented) and a 21-patient referred study in which only 6 patients actually had ascites. The two reports disagree in register: the prospective evaluation finds the overall clinical evaluation powerfully discriminative (positive likelihood ratio 37.7–83.3 when suggestive, labelled as such) while individual manoeuvres are weak in both reports (overall accuracy only 58% in the small study), and no card converts the composite figure into a claim for any single sign. This is a diagnostic-accuracy shelf, not a treatment shelf.

MeSH: Ascites/complications,diagnosis · Humans · Male · Medical History Taking · Physical Examination · Probability · Prospective Studies · Ultrasonography

Cards (4)

Card 1 — FLOOR-RISK report 1 of exactly 2 — prospective evaluation of history and examination for ascites (Simel 1988, Journal of General Internal Medicine; cohort size not stated in the abstract: N not documented): the overall clinical evaluation produced a positive likelihood ratio of 37.7–83.3 when suggestive of ascites and 2.23–3.42 when intermediate, and a negative likelihood ratio of 0.77–0.90 when not suggestive (all labelled as such, ranges as published)

Study: Prospective evaluation of operating characteristics (FLOOR-RISK report 1 of exactly 2; N not documented in the abstract)

Population: A broad spectrum of hospitalised patients, prospectively evaluated; the abstract does not state the cohort size — N not documented, printed as such. Report 1 of exactly 2 on this FLOOR-RISK shelf.

Summary: FLOOR-RISK report 1 of exactly 2 — prospective evaluation of history and examination for ascites (Simel 1988, Journal of General Internal Medicine; cohort size not stated in the abstract: N not documented): the overall clinical evaluation produced a positive likelihood ratio of 37.7–83.3 when suggestive of ascites and 2.23–3.42 when intermediate, and a negative likelihood ratio of 0.77–0.90 when not suggestive (all labelled as such, ranges as published)

Result: Individual findings (likelihood ratios labelled as such): fluid wave positive likelihood ratio 9.6; shifting dullness 5.76; reported increased abdominal girth 4.16; recent weight gain 3.20. Absence of subjective ankle swelling (negative likelihood ratio 0.10) and of increased girth (0.17) best lowered the probability; absence of bulging flanks gave a negative likelihood ratio of 0.12 and absence of peripheral oedema 0.17. The authors conclude a routine history and physical examination are quantitatively useful in the clinical evaluation of ascites.

Watch out: FLOOR-RISK: exactly 2 reports form this shelf's whole base. The strong figures belong to the overall clinical evaluation, not to any single manoeuvre — never convert the composite positive likelihood ratio (up to 83.3) into a claim for fluid wave, shifting dullness or any other single sign.

Source: Simel DL et al. Quantitating bedside diagnosis: clinical evaluation of ascites. Journal of general internal medicine. 1988. PMID: 3049966. Registry ID: none in the record. MeSH: Ascites/complications,diagnosis · Humans · Male · Medical History Taking · Physical Examination · Probability · Prospective Studies · Ultrasonography

Card 2 — FLOOR-RISK report 2 of exactly 2 — accuracy of the physical examination in suspected ascites (Cattau 1982, JAMA — 21 patients referred with questionable ascites, only 6 of whom had ascites on ultrasonography): manoeuvre sensitivity ranged 50–94% and specificity 29–82%, overall accuracy was only 58%, and the single >90%-accurate conclusion was that ascites is absent if no flank dullness is elicited

Study: Accuracy study in referred patients (FLOOR-RISK report 2 of exactly 2; N = 21, only 6 with ascites)

Population: 21 patients referred for evaluation with a diagnosis of questionable ascites, examined independently by three investigators performing five physical-examination manoeuvres; ultrasonography as reference standard; only 6 patients had ascites. Report 2 of exactly 2 on this FLOOR-RISK shelf.

Summary: FLOOR-RISK report 2 of exactly 2 — accuracy of the physical examination in suspected ascites (Cattau 1982, JAMA — 21 patients referred with questionable ascites, only 6 of whom had ascites on ultrasonography): manoeuvre sensitivity ranged 50–94% and specificity 29–82%, overall accuracy was only 58%, and the single >90%-accurate conclusion was that ascites is absent if no flank dullness is elicited

Result: Sensitivity and specificity of the manoeuvres ranged from 50% to 94% and 29% to 82% respectively; overall accuracy was only 58%. The only conclusion a physical manoeuvre could make with over 90% accuracy was that ascites is absent if no flank dullness is elicited. The authors conclude routine physical examination has definite limitations in precise diagnosis of equivocal ascites and recommend ultrasonography in questionable cases.

Watch out: FLOOR-RISK: with only 6 positive cases, every sensitivity figure in this report rests on a handful of patients — printed wherever its figures appear. This report's weak register (58% overall accuracy) stands beside, and is not averaged away by, the prospective evaluation's strong composite figures.

Source: Cattau EL et al. The accuracy of the physical examination in the diagnosis of suspected ascites. JAMA. 1982. PMID: 7057606. Registry ID: none in the record. MeSH: Adult · Aged · Ascites/diagnosis · False Negative Reactions · False Positive Reactions · Female · Humans · Male · Middle Aged · Physical Examination/methods,standards · Radiography, Abdominal · Ultrasonography

Card 3 — Cross-report summary of the two carded FLOOR-RISK reports — not an additional report (source line repeats report 1 for reference): the composite clinical evaluation looks powerful in the prospective evaluation while individual manoeuvres are weak in both reports, and the small referred study's overall accuracy was only 58%

Study: Cross-report summary of the two carded reports — not an additional report (source line repeats the prospective evaluation for reference)

Population: The two carded reports only: Simel 1988 (prospective evaluation, N not documented in its abstract) and Cattau 1982 (N = 21, 6 with ascites). This card adds no report and no data.

Summary: Cross-report summary of the two carded FLOOR-RISK reports — not an additional report (source line repeats report 1 for reference): the composite clinical evaluation looks powerful in the prospective evaluation while individual manoeuvres are weak in both reports, and the small referred study's overall accuracy was only 58%

Result: Read together: history items (increased girth, weight gain, ankle swelling) and the overall clinical impression carry most of the discriminative weight in the prospective evaluation (composite positive likelihood ratio 37.7–83.3 when suggestive, labelled as such), whereas no individual manoeuvre in either report is both sensitive and specific, and in referred equivocal cases the examination's overall accuracy was 58% with ultrasonography recommended. The disagreement in register between the two reports is content, not noise.

Watch out: FLOOR-RISK basis restated: exactly 2 reports — one with N not documented, one with N = 21 and only 6 positive cases. Nothing on this shelf rests on any third report.

Source: Simel DL et al. Quantitating bedside diagnosis: clinical evaluation of ascites. Journal of general internal medicine. 1988. PMID: 3049966. Registry ID: none in the record. MeSH: Ascites/complications,diagnosis · Humans · Male · Medical History Taking · Physical Examination · Probability · Prospective Studies · Ultrasonography

Card 4 — Synthesis: FLOOR-RISK — exactly 2 abstract-verifiable reports (prospective evaluation, N not documented; referred study, N = 21 with only 6 ascites cases) — the overall clinical evaluation is strongly discriminative when suggestive, individual manoeuvres are weak in both reports, and ultrasonography is the recommended arbiter in equivocal cases. Refusal recorded: the 1992 Rational Clinical Examination synthesis of this literature (PMID 1573754) has no abstract in its PubMed record and was therefore NOT carded as an anchor on this shelf

Study: Synthesis

Population: All reports carded on this shelf: Simel 1988 and Cattau 1982 — exactly 2 reports, the FLOOR-RISK basis printed on the face. Refusal: PMID 1573754 (1992 ascites Rational Clinical Examination) — no abstract in PubMed, not carded; absence of an abstract is not absence of the paper.

Summary: Synthesis: FLOOR-RISK — exactly 2 abstract-verifiable reports (prospective evaluation, N not documented; referred study, N = 21 with only 6 ascites cases) — the overall clinical evaluation is strongly discriminative when suggestive, individual manoeuvres are weak in both reports, and ultrasonography is the recommended arbiter in equivocal cases. Refusal recorded: the 1992 Rational Clinical Examination synthesis of this literature (PMID 1573754) has no abstract in its PubMed record and was therefore NOT carded as an anchor on this shelf

Result: No card on this shelf claims any single bedside sign diagnoses or excludes ascites: the composite evaluation and the history items carry the prospective evaluation's signal, the individual manoeuvres are weak in both reports, and the small study's only >90%-accurate conclusion is a negative one (no flank dullness → ascites absent).

Watch out: See the individual cards for each report's limits; this synthesis adds no new data.

Source: Synthesis of the reports carded above; no additional source.