SourceMed · Shelf #7815 in the ask interface
Straight-leg raising for lumbar disc herniation: 3 overlapping syntheses — sensitive but not specific (crossed test the reverse), with pooled specificity depending on population
Shelf #7815 · Bones & joints
PREDICTIVE PERFORMANCE — split by test: 3 overlapping syntheses, counted as syntheses only — straight leg raise sensitive, not specific (pooled sensitivity 0.92 / specificity 0.28 in surgical populations; 0.85 / 0.52 in the older mixed review), crossed straight leg raise specific, not sensitive (0.28–0.30 / 0.84–0.90); a diagnostic-accuracy stamp, not a treatment stamp
Stamped: 2026-11-28.
Evidence published: 1999–2012.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients with low-back pain and leg pain, how accurately do the straight-leg-raising (Lasègue) test and the crossed straight-leg-raising test identify radiculopathy due to lumbar disc herniation against imaging or surgical findings — what pooled sensitivity and specificity does the Cochrane review find for each test in surgical populations, what did the earlier systematic review pool, and why does the pain-provocation review reach inconsistent conclusions across its seven studies? (Base: 3 syntheses whose primary-study sets overlap — counted as syntheses, never as independent cohorts.)
Balance of the evidence
This shelf rests on 3 syntheses whose primary-study sets overlap — the count prints as 3 syntheses, not 3 independent cohorts. The specificity disagreement between syntheses (pooled 0.28 in surgical populations in the Cochrane review vs 0.52 in the older mixed review) is population- and reference-standard-dependent and is the content: no single pooled specificity prints without its population. Only one primary-care study exists inside the Cochrane set, so no card presents the surgical-population figures as primary-care performance. This is a diagnostic-accuracy shelf, not a treatment shelf.
MeSH: Humans · Intervertebral Disc Displacement/complications,diagnosis · Low Back Pain/etiology · Lumbosacral Region · Physical Examination/methods,standards · Radiculopathy/etiology · Sciatica/etiology
Cards (4)
Card 1 — SLR synthesis 1 of 3 — Cochrane review of physical examination for lumbar radiculopathy (van der Windt 2010; 16 cohort and 3 case-control studies): in surgical populations (disc-herniation prevalence 58–98%) the straight leg raise showed pooled sensitivity 0.92 (95% CI 0.87 to 0.95) with widely varying specificity (pooled 0.28, 0.18 to 0.40), while the crossed straight leg raise showed pooled specificity 0.90 (0.85 to 0.94) with sensitivity 0.28 (0.22 to 0.35)
Study: Cochrane systematic review (synthesis 1 of 3; primary-study sets overlap across the three syntheses)
Population: Patients with low-back pain and sciatica; tests compared with diagnostic imaging (MRI, CT, myelography) or findings at surgery; 16 cohort studies (median N = 126) and 3 case-control studies; only one study was in a primary-care population. One of 3 overlapping syntheses — never an independent cohort.
Summary: SLR synthesis 1 of 3 — Cochrane review of physical examination for lumbar radiculopathy (van der Windt 2010; 16 cohort and 3 case-control studies): in surgical populations (disc-herniation prevalence 58–98%) the straight leg raise showed pooled sensitivity 0.92 (95% CI 0.87 to 0.95) with widely varying specificity (pooled 0.28, 0.18 to 0.40), while the crossed straight leg raise showed pooled specificity 0.90 (0.85 to 0.94) with sensitivity 0.28 (0.22 to 0.35)
Result: Most physical tests in isolation performed poorly. Straight leg raise in surgical populations: pooled sensitivity 0.92 (95% CI 0.87 to 0.95), specificity widely varying (0.10 to 1.00; pooled 0.28, 0.18 to 0.40); studies using imaging showed more heterogeneity and poorer sensitivity. Crossed straight leg raise: pooled specificity 0.90 (0.85 to 0.94), sensitivity 0.28 (0.22 to 0.35). Combining positive tests increased specificity, but few studies presented combination data.
Watch out: These are surgical-population figures (prevalence 58–98%) — never present them as primary-care performance; only one primary-care study exists in this set.
Source: van der Windt DA et al. Physical examination for lumbar radiculopathy due to disc herniation in patients with low-back pain. The Cochrane database of systematic reviews. 2010. PMID: 20166095. Registry ID: none in the record. MeSH: Humans · Intervertebral Disc Displacement/complications,diagnosis · Low Back Pain/etiology · Lumbosacral Region · Physical Examination/methods,standards · Radiculopathy/etiology · Sciatica/etiology
Card 2 — SLR synthesis 2 of 3 — earlier systematic review (Vroomen 1999; 37 studies, 1965–1994): the straight leg raise was the only sign consistently reported sensitive for sciatica due to disc herniation, with pooled sensitivity 0.85 and specificity 0.52; the crossed straight leg raise was the only sign shown specific (pooled 0.30 / 0.84)
Study: Systematic review (synthesis 2 of 3; primary-study sets overlap)
Population: Studies of history and physical examination in patients suspected of sciatica due to disc herniation; 37 studies meeting selection criteria, read independently by three readers with a standard quality scoring list. One of 3 overlapping syntheses — never an independent cohort.
Summary: SLR synthesis 2 of 3 — earlier systematic review (Vroomen 1999; 37 studies, 1965–1994): the straight leg raise was the only sign consistently reported sensitive for sciatica due to disc herniation, with pooled sensitivity 0.85 and specificity 0.52; the crossed straight leg raise was the only sign shown specific (pooled 0.30 / 0.84)
Result: Pain distribution seemed the only useful history item. Straight leg raise pooled sensitivity 0.85 and specificity 0.52; crossed straight leg raise pooled sensitivity 0.30 and specificity 0.84. There was considerable disagreement on other neurological signs. The reviewers warn the studies carry important biases and methodological drawbacks, so sensitivity was probably overestimated and specificity underestimated.
Watch out: Journal note: the slate row named the Journal of Clinical Epidemiology; the PubMed record fetched gives Journal of neurology — the record governs the source line. The pooled specificity here (0.52, mixed populations) differs from the Cochrane surgical-population figure (0.28) — population prints with the number.
Source: Vroomen PC et al. Diagnostic value of history and physical examination in patients suspected of sciatica due to disc herniation: a systematic review. Journal of neurology. 1999. PMID: 10552236. Registry ID: none in the record. MeSH: Evaluation Studies as Topic · Humans · Intervertebral Disc Displacement/complications · Lumbar Vertebrae · Medical Records · Physical Examination · Sciatica/diagnosis,etiology
Card 3 — SLR synthesis 3 of 3 — pain-provocation definition review (Scaia 2012; 7 studies): four studies suggested a pain-response straight leg raise is sensitive and three that it is specific, with variability in reference standards a likely explanation for the inconsistency
Study: Systematic review of the pain-provocation definition (synthesis 3 of 3; primary-study sets overlap)
Population: Studies in which a positive straight leg raise was defined by a pain response, with standardised reference standards, reporting both sensitivity and specificity for lumbar disc herniation, radiculopathy and/or sciatica; 7 studies, 3 rated high quality on QUADAS. One of 3 overlapping syntheses — never an independent cohort.
Summary: SLR synthesis 3 of 3 — pain-provocation definition review (Scaia 2012; 7 studies): four studies suggested a pain-response straight leg raise is sensitive and three that it is specific, with variability in reference standards a likely explanation for the inconsistency
Result: Sensitivity and specificity varied among the 7 studies: 4 suggested a pain response is sensitive, 3 suggested it is specific. Variability in reference standard may partly explain the inconsistencies; pain not specific to radiculopathy (e.g. hamstring tightness) may produce false positives and inflate sensitivity.
Watch out: Journal note: the slate row named the Journal of Chiropractic Medicine; the PubMed record fetched gives Journal of back and musculoskeletal rehabilitation — the record governs the source line. Even the definition of a positive test is unsettled in this literature.
Source: Scaia V et al. The pain provocation-based straight leg raise test for diagnosis of lumbar disc herniation, lumbar radiculopathy, and/or sciatica: a systematic review of clinical utility. Journal of back and musculoskeletal rehabilitation. 2012. PMID: 23220802. Registry ID: none in the record. MeSH: Diagnostic Tests, Routine/methods · Humans · Intervertebral Disc Displacement/diagnosis · Leg/physiology · Lumbar Vertebrae · Pain Measurement/methods · Radiculopathy/diagnosis · Reference Standards · Reproducibility of Results · Sciatica/diagnosis · Sensitivity and Specificity
Card 4 — Synthesis: 3 overlapping syntheses — counted as syntheses, never as independent cohorts — agree the straight leg raise is sensitive but not specific and the crossed test specific but not sensitive, while disagreeing on the pooled specificity (0.28 surgical vs 0.52 mixed) for population and reference-standard reasons
Study: Synthesis
Population: All syntheses carded on this shelf: van der Windt 2010 Cochrane (19 studies), Vroomen 1999 (37 studies) and Scaia 2012 (7 studies). Their primary-study sets overlap; the count is 3 syntheses.
Summary: Synthesis: 3 overlapping syntheses — counted as syntheses, never as independent cohorts — agree the straight leg raise is sensitive but not specific and the crossed test specific but not sensitive, while disagreeing on the pooled specificity (0.28 surgical vs 0.52 mixed) for population and reference-standard reasons
Result: No single pooled specificity for the straight leg raise prints on this shelf without its population. The surgical-population figures must not be presented as primary-care performance, and no card implies test-guided pathways improve outcomes.
Watch out: See the individual cards for each synthesis's limits; this synthesis adds no new data.
Source: Synthesis of the reports carded above; no additional source.