SourceMed · Shelf #7829 in the ask interface
Serum zinc and selenium population distributions (PHYS): zinc timing-bound (−15.3 µg/dL by evening in NHANES), selenium geography-bound (means 80.7–100.6 µg/L) with no universal reference value feasible — whole-blood dataset kept matrix-separate
Shelf #7829 · Nutrition & feeding
PHYSIOLOGY — ESTABLISHED for population-, timing- and matrix-dependence of serum zinc and selenium / EMERGING for any single cutoff — zinc 3 datasets, selenium 4 datasets + 1 synthesis (counted separately), one whole-blood dataset never merged with serum
Stamped: 2026-11-28.
Evidence published: 1989–2018.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
What are the population distributions of serum zinc and serum selenium in adults — what means and below-cutoff proportions does the US national survey report (including the effect of time of day of the blood draw), what did the Northern Ireland population surveys find for zinc and copper, and why does the critical review of 36 selenium studies conclude that no universal reference value is feasible? (PHYSIOLOGY: matrix discipline binds — the Czech dataset is whole blood, flagged wherever it appears; µmol/L values carry µg/dL equivalents.)
Balance of the evidence
PHYSIOLOGY — no intervention stamp applies. Matrix discipline binds this shelf: the Czech dataset is whole blood and its values are never printed beside serum values without the matrix attached. Zinc — 3 datasets: NHANES 2011–2014 (4,347 participants aged ≥6 — a mixed child/adult survey whose adult-relevant strata print as such; means 84.9 µg/dL in males and 80.6 µg/dL in females, with afternoon and evening draws lower by 9.7 and 15.3 µg/dL in the adjusted model and 8.6% of males / 8.2% of females aged ≥10 below the suggested cutoffs); two Northern Ireland surveys (≈4,375 adults; 1983–84 zinc 12.1 µmol/L in men, ≈79 µg/dL, and 11.6 µmol/L in women, ≈76 µg/dL, with copper 17.2 / 19.0 µmol/L, ≈109 / ≈121 µg/dL — US-unit equivalents per the standing rule); and 1,216 Czech blood donors whose zinc (median 5,800 µg/L) and selenium (76 µg/L) are whole-blood values. Selenium — 4 datasets + 1 synthesis, counted separately on the face: Barcelona (150 adults; mean 80.7 ± 10 µg/L), Italian regions (4,201 adults; regional means 87–93 µg/L), Tehran (adult mean 100.6 ± 13 µg/L; adult N not separately documented in the abstract, labelled as such), and the whole-blood Czech observation (counted in neither serum set); the TRACY critical review of 36 suitable papers concludes geographical variability makes a single universal reference value infeasible — labelled a synthesis, not a dataset. Diurnal/fasting effects on zinc are large and print beside every mean; soil/dietary geography drives selenium (means 80.7–100.6 µg/L across the serum datasets, i.e. 8.07–10.06 µg/dL) and no universal interval is printed. Framing: PHYSIOLOGY — ESTABLISHED for population- and matrix-dependence; EMERGING for any single cutoff.
MeSH: Adolescent · Adult · Age Factors · Aged · Aged, 80 and over · Anemia/blood · Blood Specimen Collection/methods · Child · Diet · Dietary Supplements · Female · Hemoglobins/metabolism · Humans · Hypoalbuminemia/blood · Male · Middle Aged · Nutrition Surveys · Nutritional Status · Pregnancy · Reference Values · Sex Factors · United States/epidemiology · Young Adult · Zinc/blood/deficiency · Alcohol Drinking/blood · Cholesterol/blood · Copper/blood · Coronary Disease/etiology · Hypertension/complications · Northern Ireland · Risk Factors · Smoking/blood · Zinc/blood · Blood Donors · Cadmium/blood/deficiency · Cadmium Poisoning/blood · Copper/blood/deficiency/poisoning · Czech Republic · Environmental Monitoring · Health Surveys · Lead/blood · Lead Poisoning/blood · Mercury/blood · Mercury Poisoning/blood · Nutritional Physiological Phenomena · Selenium/blood/deficiency/poisoning · Spectrophotometry, Atomic · Zinc/blood/deficiency/poisoning · Selenium/blood · Spain · Arthritis, Rheumatoid/blood · Child, Preschool · Coronary Disease/blood · Infant · Italy · Lupus Erythematosus, Systemic/blood · Neoplasms/blood · Phenylketonurias/blood · Iran · Sex Characteristics · Chemistry Techniques, Analytical/standards · Evaluation Studies as Topic · Patient Selection · Peer Review, Research · Reproducibility of Results
Cards (8)
Card 1 — Zinc dataset 1 of 3 (Hennigar 2018, The Journal of Nutrition — NHANES 2011–2014, 4,347 participants aged ≥6 years): mean serum zinc was 84.9 ± 0.8 µg/dL in males and 80.6 ± 0.6 µg/dL in females; afternoon and evening draws were lower than morning draws by 9.7 and 15.3 µg/dL respectively in the adjusted model, and 8.6% of males and 8.2% of females aged ≥10 years fell below the suggested cutoffs
Study: Primary human physiology dataset — serum zinc, US national survey (zinc dataset 1 of 3)
Population: 4,347 males and females aged ≥6 years in NHANES 2011–2014 (a mixed child/adult national survey — its adult-relevant strata print as such: the below-cutoff proportions are for ages ≥10, and 3.8% of children under 10 were below cutoff, as published). Serum zinc by the survey's standard methods; dietary and supplemental zinc assessed. The record's abstract states the analysis was registered as ISRCTN96013840, printed in its source line.
Summary: Zinc dataset 1 of 3 (Hennigar 2018, The Journal of Nutrition — NHANES 2011–2014, 4,347 participants aged ≥6 years): mean serum zinc was 84.9 ± 0.8 µg/dL in males and 80.6 ± 0.6 µg/dL in females; afternoon and evening draws were lower than morning draws by 9.7 and 15.3 µg/dL respectively in the adjusted model, and 8.6% of males and 8.2% of females aged ≥10 years fell below the suggested cutoffs
Result: Mean ± SE serum zinc was 84.9 ± 0.8 µg/dL in males and 80.6 ± 0.6 µg/dL in females (P < 0.0001). In adjusted regression, afternoon and evening blood draws were negatively associated with serum zinc (β = −9.7 and −15.3; P < 0.0001), while serum albumin (β = 16.1; P < 0.0001) and haemoglobin (β = 1.0; P = 0.0048) were positively associated. Hypoalbuminaemia (OR 11.2, 99% CI 3.4 to 37.3 — a relative odds measure), anaemia in females (OR 3.4, 1.7 to 6.9) and pregnancy (OR 9.6, 2.9 to 31.9) increased the odds of being below the cutoff. Zinc from diet or supplements did not affect serum zinc (P > 0.01). Approximately 8.6% of males and 8.2% of females aged ≥10 years were below the serum zinc cutoff.
Watch out: Time of day is a first-order effect here (up to −15.3 µg/dL by evening): no serum zinc mean from any dataset on this shelf may be compared without draw timing. The dataset spans ages ≥6 — it is not an adults-only sample, and its child stratum is not carded as adult data.
Source: Hennigar SR et al. Serum Zinc Concentrations in the US Population Are Related to Sex, Age, and Time of Blood Draw but Not Dietary or Supplemental Zinc. The Journal of nutrition. 2018. PMID: 29947812. Registry ID: ISRCTN96013840. MeSH: Adolescent · Adult · Age Factors · Aged · Aged, 80 and over · Anemia/blood · Blood Specimen Collection/methods · Child · Diet · Dietary Supplements · Female · Hemoglobins/metabolism · Humans · Hypoalbuminemia/blood · Male · Middle Aged · Nutrition Surveys · Nutritional Status · Pregnancy · Reference Values · Sex Factors · United States/epidemiology · Young Adult · Zinc/blood/deficiency
Estimate type: adjusted estimate, as stated in the card.
Card 2 — Zinc dataset 2 of 3 (McMaster 1992, American Journal of Clinical Nutrition — two Northern Ireland population surveys, ≈4,375 adults aged 25–64): in 1983–84 mean serum zinc was 12.1 ± 1.7 µmol/L in men (≈79 µg/dL) and 11.6 ± 1.4 µmol/L in women (≈76 µg/dL); mean serum copper was 17.2 ± 3.1 µmol/L in men (≈109 µg/dL) and 19.0 ± 3.9 µmol/L in women (≈121 µg/dL) — US-unit equivalents added per the standing rule
Study: Primary human physiology dataset — serum zinc and copper, Northern Ireland surveys (zinc dataset 2 of 3; copper limb carded as published alongside)
Population: Non-fasting adults aged 25–64 in two independent Northern Ireland population surveys: 1983–84 (1,144 men; 1,055 women neither pregnant nor taking oestrogens/progestogens) and 1986–87 (1,142 men; 1,034 women). Serum zinc and copper in µmol/L as published, with µg/dL equivalents (zinc ×6.54, copper ×6.35) added per the standing US-units rule.
Summary: Zinc dataset 2 of 3 (McMaster 1992, American Journal of Clinical Nutrition — two Northern Ireland population surveys, ≈4,375 adults aged 25–64): in 1983–84 mean serum zinc was 12.1 ± 1.7 µmol/L in men (≈79 µg/dL) and 11.6 ± 1.4 µmol/L in women (≈76 µg/dL); mean serum copper was 17.2 ± 3.1 µmol/L in men (≈109 µg/dL) and 19.0 ± 3.9 µmol/L in women (≈121 µg/dL) — US-unit equivalents added per the standing rule
Result: In 1983–84, copper in 1,144 males was 17.2 ± 3.1 µmol/L (≈109 µg/dL) and zinc 12.1 ± 1.7 µmol/L (≈79 µg/dL); copper in 1,055 females was 19.0 ± 3.9 µmol/L (≈121 µg/dL) and zinc 11.6 ± 1.4 µmol/L (≈76 µg/dL). In 1986–87, copper in 1,142 males was 17.9 ± 3.3 µmol/L (≈114 µg/dL) and zinc 13.2 ± 2.1 µmol/L (≈86 µg/dL); copper in 1,034 females was 20.1 ± 3.9 µmol/L (≈128 µg/dL) and zinc 12.7 ± 2.0 µmol/L (≈83 µg/dL). Zinc but not copper decreased from early morning to late afternoon; both were unaffected by reported postprandial time. Copper rose with age in both sexes; zinc showed only a slight upward trend.
Watch out: Two surveys four years apart differ by ~1 µmol/L in zinc within the same population — survey-to-survey drift of that size is part of this shelf's content, and the diurnal fall (morning to late afternoon) prints beside every mean, as in the NHANES dataset.
Source: McMaster D et al. Serum copper and zinc in random samples of the population of Northern Ireland. The American journal of clinical nutrition. 1992. PMID: 1636623. Registry ID: none in the record. MeSH: Adult · Age Factors · Alcohol Drinking/blood · Cholesterol/blood · Copper/blood · Coronary Disease/etiology · Female · Humans · Hypertension/complications · Male · Middle Aged · Northern Ireland · Reference Values · Risk Factors · Sex Factors · Smoking/blood · Zinc/blood
Card 3 — Zinc/selenium dataset — WHOLE BLOOD, matrix-labelled (Benes 2000, Central European Journal of Public Health — 1,216 healthy adult blood donors, Czech Republic): median zinc 5,800 µg/L and selenium 76 µg/L in WHOLE BLOOD — never printed beside serum values without the matrix attached
Study: Primary human physiology dataset — trace elements in WHOLE BLOOD (matrix-labelled; zinc dataset 3 of 3 and a selenium whole-blood observation, counted in neither serum set)
Population: 1,216 adult blood donors (896 men, 320 women; average age 33) in the Czech Republic, 1996–1998, with trace elements in whole blood by atomic absorption spectrometry (a separate child sample of 758 in the same paper is not counted in this adult dataset). Matrix discipline binds this card: whole blood, not serum.
Summary: Zinc/selenium dataset — WHOLE BLOOD, matrix-labelled (Benes 2000, Central European Journal of Public Health — 1,216 healthy adult blood donors, Czech Republic): median zinc 5,800 µg/L and selenium 76 µg/L in WHOLE BLOOD — never printed beside serum values without the matrix attached
Result: Adult medians in whole blood were: cadmium 0.7 µg/L, copper 800 µg/L, mercury 0.78 µg/L, lead 41 µg/L, selenium 76 µg/L (7.6 µg/dL) and zinc 5,800 µg/L (580 µg/dL). Statistically significant differences between men and women were found for copper, mercury, lead and zinc. The authors note the concentrations correspond to published values for populations not occupationally exposed.
Watch out: WHOLE BLOOD: whole-blood zinc (~5,800 µg/L, largely erythrocyte zinc) is roughly sevenfold serum zinc and the two matrices must never be merged or compared as if one scale. This dataset is counted as zinc dataset 3 of 3 with its matrix flag, and is NOT counted among the serum selenium datasets.
Source: Benes B et al. The concentration levels of Cd, Pb, Hg, Cu, Zn and Se in blood of the population in the Czech Republic. Central European journal of public health. 2000. PMID: 10857051. Registry ID: none in the record. MeSH: Adult · Blood Donors · Cadmium/blood/deficiency · Cadmium Poisoning/blood · Child · Copper/blood/deficiency/poisoning · Czech Republic · Environmental Monitoring · Female · Health Surveys · Humans · Lead/blood · Lead Poisoning/blood · Male · Mercury/blood · Mercury Poisoning/blood · Nutritional Physiological Phenomena · Reference Values · Selenium/blood/deficiency/poisoning · Spectrophotometry, Atomic · Zinc/blood/deficiency/poisoning
Card 4 — Selenium dataset 1 of 4 (Torra 1997, Biological Trace Element Research — 150 healthy adults, Barcelona): mean serum selenium 80.7 ± 10 µg/L (8.07 µg/dL), range 60–106 µg/L, by graphite-furnace atomic spectrometry
Study: Primary human physiology dataset — serum selenium, Barcelona (selenium dataset 1 of 4)
Population: 150 healthy subjects aged 18–70 from the general population of Barcelona, Spain, randomly sampled; serum selenium by graphite furnace atomic spectrometry following the stabilised-temperature-platform-furnace concept, as published.
Summary: Selenium dataset 1 of 4 (Torra 1997, Biological Trace Element Research — 150 healthy adults, Barcelona): mean serum selenium 80.7 ± 10 µg/L (8.07 µg/dL), range 60–106 µg/L, by graphite-furnace atomic spectrometry
Result: Serum selenium ranged between 60 and 106 µg/L with a mean of 80.7 ± 10 µg/L (8.07 ± 1.0 µg/dL). No subject was below the 45 µg/L threshold the authors cite in connection with coronary and cancer risk literature, and the authors consider the values within safe limits — their interpretive framing, printed as such.
Watch out: A single-city sample of 150: soil/dietary geography drives selenium, so this mean is a Barcelona value, not a Spanish or European one.
Source: Torra M et al. Serum selenium concentration of a healthy northwest Spanish population. Biological trace element research. 1997. PMID: 9363327. Registry ID: none in the record. MeSH: Adolescent · Adult · Age Factors · Aged · Female · Humans · Male · Middle Aged · Reference Values · Selenium/blood · Sex Factors · Spain · Spectrophotometry, Atomic
Card 5 — Selenium dataset 2 of 4 (Morisi 1989, Annali dell'Istituto Superiore di Sanità — 4,201 adults across Italian regions): regional mean serum selenium 87–93 µg/L (8.7–9.3 µg/dL), approximately 5 µg/L higher than the means in ten European countries, with a decreasing trend above age 60
Study: Primary human physiology dataset — serum selenium, Italian regions (selenium dataset 2 of 4)
Population: 4,201 adult subjects (with 1,217 children in the same programme, not counted here) drawn from populations previously enrolled in Italian epidemiological prevention programmes, with standardised methods, as published.
Summary: Selenium dataset 2 of 4 (Morisi 1989, Annali dell'Istituto Superiore di Sanità — 4,201 adults across Italian regions): regional mean serum selenium 87–93 µg/L (8.7–9.3 µg/dL), approximately 5 µg/L higher than the means in ten European countries, with a decreasing trend above age 60
Result: Mean observed values for the various adult populations examined varied between 87 and 93 µg/L and were approximately 5 µg/L higher than the mean values in ten European countries. Paediatric means (under 15 years) were slightly lower (78–83 µg/L). A decreasing trend with age above 60 years was observed, especially in males; no significant difference was observed for sex or geographic area of residence within Italy.
Watch out: Regional means are ranges across sub-populations (87–93 µg/L), not a single pooled Italian mean — printed as the range the abstract gives.
Source: Morisi G et al. Age and sex specific reference serum selenium levels estimated for the Italian population. Annali dell'Istituto superiore di sanita. 1989. PMID: 2624351. Registry ID: none in the record. MeSH: Adolescent · Adult · Age Factors · Aged · Arthritis, Rheumatoid/blood · Child · Child, Preschool · Coronary Disease/blood · Female · Humans · Infant · Italy · Lupus Erythematosus, Systemic/blood · Male · Middle Aged · Neoplasms/blood · Phenylketonurias/blood · Reference Values · Selenium/blood · Sex Factors
Card 6 — Selenium dataset 3 of 4 (Safaralizadeh 2005, Nutrition Journal — Tehran adults; the study's 184 participants include children and the adult N is not separately documented in the abstract): adult mean serum selenium 100.6 ± 13 µg/L (10.06 µg/dL) — men 102.2 ± 12, women 93.9 ± 14 µg/L
Study: Primary human physiology dataset — serum selenium, Tehran adults (selenium dataset 3 of 4; adult N not documented in the abstract)
Population: 184 healthy individuals in Tehran, Iran, divided into children (1–16 years) and adults (over 16) for analysis; the adult subset's own N is not separately documented in the abstract and prints as 'adult N not documented' — no N is imported. Serum selenium by hydride generation and flame atomic absorption spectroscopy.
Summary: Selenium dataset 3 of 4 (Safaralizadeh 2005, Nutrition Journal — Tehran adults; the study's 184 participants include children and the adult N is not separately documented in the abstract): adult mean serum selenium 100.6 ± 13 µg/L (10.06 µg/dL) — men 102.2 ± 12, women 93.9 ± 14 µg/L
Result: In adults (over 16 years) the mean serum selenium level was 100.6 ± 13 µg/L; among women 93.9 ± 14 µg/L and among men 102.2 ± 12 µg/L, a significant sex difference (P < 0.005). In children the mean was 84.3 ± 11 µg/L with no sex difference. There was a positive correlation between selenium concentration and age in men (P < 0.001). Calculated daily intakes were 67 µg (men) and 62.1 µg (women). The authors note Tehran values resemble other Middle Eastern populations, particularly Saudi Arabia.
Watch out: 'Adult N not documented' labelling applies to this dataset, per the standing rule. The study total (184) includes children and must never be printed as the adult N.
Source: Safaralizadeh R et al. Serum concentration of selenium in healthy individuals living in Tehran. Nutrition journal. 2005. PMID: 16285883. Registry ID: none in the record. MeSH: Adolescent · Adult · Child · Child, Preschool · Female · Humans · Infant · Iran · Male · Reference Values · Selenium/blood · Sex Characteristics
Card 7 — Selenium synthesis — labelled a synthesis, not a dataset (Alfthan 1996, Journal of Trace Elements in Medicine and Biology — TRACY-project critical review: of 291 papers published 1983–1993, 36 were suitable): geographical variation in selenium intake was so large that one universal reference serum selenium value for the world's population was not feasible
Study: Critical review / synthesis of 36 suitable papers (TRACY protocol) — labelled a synthesis, never counted as a dataset
Population: Published reports on serum/plasma selenium concentrations critically reviewed against the international TRACY project's pre-analytical and analytical criteria; only data on healthy adults were retained from the 36 suitable papers. Labelled a synthesis on this shelf — it is not a fifth selenium dataset.
Summary: Selenium synthesis — labelled a synthesis, not a dataset (Alfthan 1996, Journal of Trace Elements in Medicine and Biology — TRACY-project critical review: of 291 papers published 1983–1993, 36 were suitable): geographical variation in selenium intake was so large that one universal reference serum selenium value for the world's population was not feasible
Result: Geographical area and time of sampling were the pre-analytical factors of high importance; gender, occupation, diet data and supplement/medication use were also important determinants, while ethnic origin, smoking, fasting, contamination control and storage were of relatively low importance. Analytical accuracy criteria were generally satisfied. Due to the geographical variation of selenium intake, one universal reference serum selenium value for the world's population was not feasible, though the selected data documented concentration levels among populations of different (mostly European) areas.
Watch out: The TRACY conclusion is the shelf's selenium verdict: no universal reference value. Any single dataset's mean printed without its geography contradicts this synthesis.
Source: Alfthan G et al. Reference values for serum selenium in various areas-evaluated according to the TRACY protocol. Journal of trace elements in medicine and biology : organ of the Society for Minerals and Trace Elements (GMS). 1996. PMID: 8829130. Registry ID: none in the record. MeSH: Adult · Chemistry Techniques, Analytical/standards · Evaluation Studies as Topic · Female · Humans · Male · Patient Selection · Peer Review, Research · Reference Values · Reproducibility of Results · Selenium/blood
Card 8 — Synthesis: serum zinc and selenium are population-, timing- and matrix-bound distributions — zinc means 84.9 (men) / 80.6 (women) µg/dL in NHANES with an evening-draw penalty of −15.3 µg/dL, and 12.1 / 11.6 µmol/L (≈79 / ≈76 µg/dL) in 1983–84 Northern Ireland; selenium serum means run 80.7 µg/L (Barcelona) to 87–93 µg/L (Italian regions) to 100.6 µg/L (Tehran adults, adult N not documented), the Czech dataset is whole blood and never merges with serum, and the TRACY review of 36 suitable papers concludes no universal selenium reference value is feasible — ESTABLISHED for population- and matrix-dependence, EMERGING for any single cutoff
Study: Synthesis
Population: All reports carded on this shelf, counted separately on the face as the row directs: zinc — 3 datasets (NHANES 2011–2014, N = 4,347 aged ≥6; Northern Ireland surveys, ≈4,375 adults; Czech whole-blood donors, N = 1,216, matrix-flagged). Selenium — 4 datasets + 1 synthesis counted separately (Barcelona N = 150; Italian regions N = 4,201 adults; Tehran, adult N not documented; the Czech whole-blood selenium median counted in neither serum set) plus the TRACY synthesis (36 papers).
Summary: Synthesis: serum zinc and selenium are population-, timing- and matrix-bound distributions — zinc means 84.9 (men) / 80.6 (women) µg/dL in NHANES with an evening-draw penalty of −15.3 µg/dL, and 12.1 / 11.6 µmol/L (≈79 / ≈76 µg/dL) in 1983–84 Northern Ireland; selenium serum means run 80.7 µg/L (Barcelona) to 87–93 µg/L (Italian regions) to 100.6 µg/L (Tehran adults, adult N not documented), the Czech dataset is whole blood and never merges with serum, and the TRACY review of 36 suitable papers concludes no universal selenium reference value is feasible — ESTABLISHED for population- and matrix-dependence, EMERGING for any single cutoff
Result: PHYSIOLOGY framing only — no intervention stamp applies. Diurnal and fasting effects on zinc are large and print beside every mean; soil/dietary geography drives selenium; no universal interval is printed for either analyte.
Watch out: See the individual cards for each report's limits; this synthesis adds no new data.
Source: Synthesis of the reports carded above; no additional source.