Single-fibre EMG jitter reference values in healthy volunteers (PHYS, 3 small datasets, N = 57/32/19): suggested limits are muscle- and method-specific — 32/49 µs volitional orbicularis oculi, 26/34 µs stimulated tibialis anterior, 21/30 µs stimulated masseter
Shelf #7831 · Brain, stroke & mind
PHYSIOLOGY — EMERGING: single-fibre EMG jitter limits are muscle- and method-specific (suggested mean limits 21–32 µs across 3 small datasets, N = 57 / 32 / 19) — authors' suggested cut-offs, not CLSI-derived intervals
Stamped: 2026-11-28.
Evidence published: 2007–2022.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
What are the reference values for single-fibre electromyography jitter (mean consecutive difference, MCD — the variability of neuromuscular transmission timing between muscle fibres of one motor unit) in healthy volunteers — what upper limits do the concentric-needle orbicularis oculi and frontalis datasets suggest, what mean jitter and suggested limits does stimulated single-fibre EMG give in the tibialis anterior, and what limits were derived for the stimulated masseter? (PHYSIOLOGY — EMERGING: every limit prints with its muscle and method; all datasets are small and their Ns print.)
Balance of the evidence
PHYSIOLOGY — no intervention stamp applies. Reference limits are muscle- and method-specific by construction (volitional concentric-needle vs stimulated technique give different mean-consecutive-difference distributions) — no limit is printed without its muscle and method attached. All three datasets are small (N = 57, 32 and 19; total 108) and their Ns print on the face. Volitional concentric-needle jitter in orbicularis oculi (57 Sudanese volunteers) averaged 26.9 ± 3.3 µs with suggested upper limits of 32 µs (mean) and 49 µs (individual pairs), frontalis 31 / 49 µs. Stimulated single-fibre EMG in tibialis anterior (32 subjects) gave mean MCD 19.79 ± 2.72 µs with suggested limits of 26 / 34 µs. Stimulated masseter jitter (19 volunteers, 426 endplates) gave a pooled mean MCD of 16.0 µs with suggested limits of 21 µs (study mean) and 30 µs (individual fibre). The suggested limits are the authors' proposed cut-offs from single samples, not CLSI-derived intervals, and print as 'suggested'. Framing: PHYSIOLOGY — EMERGING.
MeSH: Adolescent · Adult · Aged · Blinking/physiology · Cross-Sectional Studies · Electric Stimulation · Electrodes · Electromyography/methods · Eyelids/physiology · Facial Muscles/physiology · Female · Forehead/physiology · Healthy Volunteers · Humans · Male · Middle Aged · Muscle Contraction/physiology · Muscle Fibers, Skeletal/physiology · Myasthenia Gravis/diagnosis/physiopathology · Neuromuscular Junction/physiology · Prospective Studies · Sudan · Young Adult · Electric Stimulation/methods · Masseter Muscle/physiology/radiation effects · Muscle Contraction/physiology/radiation effects · Muscle Fibers, Skeletal/physiology/radiation effects · Reaction Time/physiology/radiation effects · Reference Values
Cards (4)
Card 1 — Dataset 1 of 3 (Musa 2020, Scientific Reports — 57 healthy Sudanese volunteers, concentric-needle jitter with voluntary activation): mean jitter in orbicularis oculi was 26.9 ± 3.3 µs, with suggested upper limits of 32 µs for the mean and 49 µs for individual fibre pairs (frontalis 31 / 49 µs) — N = 57 prints on the face
Study: Primary human physiology dataset — concentric-needle jitter, orbicularis oculi and frontalis, volitional (dataset 1 of 3; N = 57)
Population: 57 healthy volunteers (20 men, 37 women; mean age 43.6 ± 14.2 years, range 18–70) in Sudan, with voluntarily activated orbicularis oculi and frontalis both tested in the same individual using a concentric needle electrode; jitter expressed as the mean consecutive difference (MCD) of 30 potential pairs. Small dataset — its N prints on the face, per the row.
Summary: Dataset 1 of 3 (Musa 2020, Scientific Reports — 57 healthy Sudanese volunteers, concentric-needle jitter with voluntary activation): mean jitter in orbicularis oculi was 26.9 ± 3.3 µs, with suggested upper limits of 32 µs for the mean and 49 µs for individual fibre pairs (frontalis 31 / 49 µs) — N = 57 prints on the face
Result: For orbicularis oculi, mean jitter was 26.9 ± 3.3 µs (upper 95% confidence limit 31.97), mean individual fibre-pair jitter 26.1 ± 8.9 µs (upper limit 41.8) and mean outlier jitter 38.5 ± 5.7 µs (upper limit 49.0). For frontalis, the corresponding values were 27.1 ± 3.0 µs (31.32), 26.4 ± 9.4 µs (42.9) and 39.9 ± 5 µs (49.2). The suggested practical upper limits for mean jitter and outliers were 32 and 49 µs for orbicularis oculi, and 31 and 49 µs for frontalis.
Watch out: Suggested limits from a single sample of 57 — the authors' proposed cut-offs, printed as 'suggested', not CLSI-derived intervals. Volitional concentric-needle technique: its limits do not transfer to stimulated technique or to other muscles.
Source: Musa AMM et al. Reference Jitter Values for Concentric Needle Electrode of Orbicularis Oculi and Frontalis Muscles Using Voluntary Activation Method in Sudanese Population. Scientific reports. 2020. PMID: 31974444. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Blinking/physiology · Cross-Sectional Studies · Electric Stimulation · Electrodes · Electromyography/methods · Eyelids/physiology · Facial Muscles/physiology · Female · Forehead/physiology · Healthy Volunteers · Humans · Male · Middle Aged · Muscle Contraction/physiology · Muscle Fibers, Skeletal/physiology · Myasthenia Gravis/diagnosis/physiopathology · Neuromuscular Junction/physiology · Prospective Studies · Sudan · Young Adult
Card 2 — Dataset 2 of 3 (Kouyoumdjian 2022, Frontiers in Neurology — 32 healthy subjects, stimulated single-fibre EMG of tibialis anterior with a concentric needle): mean MCD was 19.79 ± 2.72 µs, with suggested upper limits of 26 µs for the mean and 34 µs for individual pairs — N = 32 prints on the face
Study: Primary human physiology dataset — stimulated concentric-needle jitter, tibialis anterior (dataset 2 of 3; N = 32)
Population: 32 healthy subjects with jitter measured in tibialis anterior by the intramuscular microaxonal stimulation technique using a disposable concentric needle. Small dataset — its N prints on the face. This record carries no MeSH in PubMed; its source line says so, and the shelf's top-level MeSH is taken from the other two datasets.
Summary: Dataset 2 of 3 (Kouyoumdjian 2022, Frontiers in Neurology — 32 healthy subjects, stimulated single-fibre EMG of tibialis anterior with a concentric needle): mean MCD was 19.79 ± 2.72 µs, with suggested upper limits of 26 µs for the mean and 34 µs for individual pairs — N = 32 prints on the face
Result: The mean MCD and the mean MCD of the 27th value from the 32 subjects were normally distributed, at 19.79 ± 2.72 µs and 26.88 ± 3.56 µs respectively. The suggested limit for the mean MCD is ≥26 µs (i.e. values at or above are outside the suggested normal limit, as published) and for individual values >34 µs.
Watch out: Stimulated technique in a limb muscle: neither its mean (19.79 µs) nor its limits (26 / 34 µs) may be set beside the volitional facial-muscle values as if one scale — muscle and method attach to every limit on this shelf.
Source: Kouyoumdjian JA et al. Concentric needle jitter: Reference values in stimulated Tibialis Anterior muscle. Frontiers in neurology. 2022. PMID: 35937059. Registry ID: none in the record. MeSH: none in the record
Card 3 — Dataset 3 of 3 (Rousseff 2007, Muscle & Nerve — 19 healthy volunteers, stimulated jitter in masseter): pooled mean MCD was 16.0 µs (mean of individual study means 13.6 µs), with suggested upper limits of 21 µs for a study mean and 30 µs for an individual fibre — small N = 19 prints on the face
Study: Primary human physiology dataset — stimulated jitter, masseter (dataset 3 of 3; N = 19)
Population: 19 healthy volunteers (median age 25, range 18–51) with stimulated jitter measured in the masseter: axonal microstimulation via a monopolar needle electrode, recording with a single-fibre EMG electrode; 426 endplates studied. The smallest dataset on this shelf — N = 19 prints on the face and the dataset is never load-bearing alone for a general jitter claim.
Summary: Dataset 3 of 3 (Rousseff 2007, Muscle & Nerve — 19 healthy volunteers, stimulated jitter in masseter): pooled mean MCD was 16.0 µs (mean of individual study means 13.6 µs), with suggested upper limits of 21 µs for a study mean and 30 µs for an individual fibre — small N = 19 prints on the face
Result: MCD values for the 426 endplates were skewed, with minimum 4.3 µs, maximum 44.7 µs and the distribution's maximum at 11 µs. Mean pooled MCD was 16.0 µs and the mean of mean MCD per study was 13.6 µs. The 95th upper percentile for an individual fibre was 29.3 µs. The authors suggest an upper normal limit for mean MCD per study of 21 µs and for individual fibres of 30 µs, and describe the stimulated masseter study as easy and reliable — their assessment, printed as such.
Watch out: N = 19 volunteers (426 endplates — endplates are not volunteers, and the two denominators are never interchanged). Suggested limits from a single small sample, printed as 'suggested'.
Source: Rousseff RT et al. Stimulated jitter in the masseter muscle: normative values. Muscle & nerve. 2007. PMID: 16955469. Registry ID: none in the record. MeSH: Adolescent · Adult · Electric Stimulation/methods · Electromyography/methods · Female · Humans · Male · Masseter Muscle/physiology/radiation effects · Middle Aged · Muscle Contraction/physiology/radiation effects · Muscle Fibers, Skeletal/physiology/radiation effects · Reaction Time/physiology/radiation effects · Reference Values
Card 4 — Synthesis: single-fibre EMG jitter reference values are muscle- and method-specific by construction — volitional concentric-needle orbicularis oculi/frontalis in 57 volunteers (mean ≈27 µs; suggested limits 31–32 µs mean, 49 µs individual pairs), stimulated tibialis anterior in 32 subjects (mean 19.79 µs; suggested limits 26 / 34 µs), and stimulated masseter in 19 volunteers (pooled mean 16.0 µs; suggested limits 21 / 30 µs) — three small datasets (total N = 108), every limit carrying its muscle and method, and the whole limb framed PHYSIOLOGY — EMERGING
Study: Synthesis
Population: All datasets carded on this shelf: Musa 2020 (N = 57), Kouyoumdjian 2022 (N = 32) and Rousseff 2007 (N = 19) — total N = 108 across datasets, each dataset's N printed on its card. Distinct from pack #7081 (nerve conduction normative values — a different neurophysiological measurement).
Summary: Synthesis: single-fibre EMG jitter reference values are muscle- and method-specific by construction — volitional concentric-needle orbicularis oculi/frontalis in 57 volunteers (mean ≈27 µs; suggested limits 31–32 µs mean, 49 µs individual pairs), stimulated tibialis anterior in 32 subjects (mean 19.79 µs; suggested limits 26 / 34 µs), and stimulated masseter in 19 volunteers (pooled mean 16.0 µs; suggested limits 21 / 30 µs) — three small datasets (total N = 108), every limit carrying its muscle and method, and the whole limb framed PHYSIOLOGY — EMERGING
Result: PHYSIOLOGY framing only — no intervention stamp applies. The suggested limits are authors' proposed cut-offs from single samples, not CLSI-derived intervals, and print as 'suggested' throughout.
Watch out: See the individual cards for each report's limits; this synthesis adds no new data.