Berlin Questionnaire accuracy for obstructive sleep apnoea — derivation, general-population validation and the syntheses

Shelf #7854 · Lungs, breathing & sleep

PREDICTIVE PERFORMANCE — population-dependent: sensitivity 0.86 in the enriched primary-care derivation (subset N = 100) vs 58.8% at AHI ≥15 in the general population; pooled specificity falls to 38% at AHI ≥30 (108-study synthesis); 3 of 5 anchors are syntheses, counted as syntheses; the defective Epworth figure in PMID 27919588 is omitted and the omission stated. A screening-accuracy stamp, not a treatment stamp

Stamped: 2026-11-28.

Evidence published: 1999–2022.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In adults, how accurately does the Berlin Questionnaire (ten items in three categories — snoring behaviour, waketime sleepiness/fatigue, and obesity or hypertension; high risk when two or more categories are persistently positive) identify obstructive sleep apnoea against sleep-study measurement (polysomnography or portable monitoring, scored by apnoea–hypopnoea or respiratory-disturbance index) — what sensitivity and specificity did its primary-care derivation find at an RDI above 5, how much worse does it perform in an unselected general-population sample at AHI ≥15 and ≥30, and what pooled sensitivity and specificity do the meta-analyses give by OSA severity and by clinical cohort, including how it compares with STOP-Bang, STOP and the Epworth Sleepiness Scale inside the same syntheses?

Balance of the evidence

Screening accuracy, population-dependent by design of the evidence: derivation sensitivity 0.86/specificity 0.77 at RDI >5 in enriched primary care (sleep-study subset only 100 of 744 respondents) falls to 58.8% sensitivity at AHI ≥15 in an unselected general-population sample, and pooled specificity collapses with severity threshold (59% at ≥5, 44% at ≥15, 38% at ≥30 in the 108-study synthesis). No figure prints without its AHI threshold, cohort and reference device. The Epworth specificity in PMID 27919588's abstract is printed as an impossible three-digit percentage — a typographical error in the source — and is omitted — no Epworth figure is printed from that abstract. This is not a treatment shelf.

MeSH: Female · Humans · Hypertension/complications · Logistic Models · Male · Middle Aged · Monitoring, Physiologic · Obesity/complications · Reproducibility of Results · Respiration Disorders/etiology · Risk Factors · Sex Factors · Sleep Apnea Syndromes/complications/diagnosis/physiopathology · Snoring/etiology · Surveys and Questionnaires · Sensitivity and Specificity · Singapore · Sleep Apnea, Obstructive/diagnosis · Surveys and Questionnaires/standards · Berlin · Mass Screening · Adult · Polysomnography · Prospective Studies · Sleep Apnea, Obstructive

Cards (6)

Card 1 — Derivation (originators' own report, programme-labelled) — 744 primary-care respondents, of whom only 100 had portable sleep studies (that subset prints): high-risk grouping predicted RDI >5 with sensitivity 0.86, specificity 0.77, PPV 0.89 and likelihood ratio 3.79

Study: Primary-care derivation study (originators' report)

Population: 744 adults at 5 Cleveland primary-care sites completed the questionnaire (snoring behaviour, waketime sleepiness/fatigue, obesity or hypertension; high risk = persistent frequent symptoms in ≥2 of 3 categories); 100 underwent portable unattended sleep studies scored by respiratory disturbance index (RDI).

Summary: Derivation (originators' own report, programme-labelled) — 744 primary-care respondents, of whom only 100 had portable sleep studies (that subset prints): high-risk grouping predicted RDI >5 with sensitivity 0.86, specificity 0.77, PPV 0.89 and likelihood ratio 3.79

Result: For RDI >5, high-risk grouping gave sensitivity 0.86, specificity 0.77, positive predictive value 0.89 and a likelihood ratio of 3.79 (labelled as such). Of 744 respondents, 279 (37.5%) were high risk. Symptom questions showed internal consistency (Cronbach 0.86–0.92).

Watch out: An enriched primary-care sample with a 100-patient sleep-study subset — its sensitivity is the programme's best case, not its transportable value.

Source: Netzer NC et al. Using the Berlin Questionnaire to identify patients at risk for the sleep apnea syndrome. Annals of Internal Medicine. 1999. PMID: 10507956. Registry ID: none in the record. MeSH: Female · Humans · Hypertension/complications · Logistic Models · Male · Middle Aged · Monitoring, Physiologic · Obesity/complications · Reproducibility of Results · Respiration Disorders/etiology · Risk Factors · Sex Factors · Sleep Apnea Syndromes/complications/diagnosis/physiopathology · Snoring/etiology · Surveys and Questionnaires

Card 2 — General-population validation (242 subjects, home sleep testing) — the population gradient is the content: at AHI ≥15 sensitivity was only 58.8% (specificity 77.6%, NPV 82.9%, PPV 50.6%; AUC 0.682), rising at AHI ≥30 to sensitivity 76.9%, specificity 72.7%, NPV 96.3%, PPV 25.3% (AUC 0.748)

Study: General-population validation cohort

Population: 242 subjects in a population-based cohort with home-based type 3 sleep testing scored by 2012 AASM criteria; moderate-to-severe OSA prevalence 28.1%, severe 10.7%; 79 subjects (32.6%) were Berlin high risk.

Summary: General-population validation (242 subjects, home sleep testing) — the population gradient is the content: at AHI ≥15 sensitivity was only 58.8% (specificity 77.6%, NPV 82.9%, PPV 50.6%; AUC 0.682), rising at AHI ≥30 to sensitivity 76.9%, specificity 72.7%, NPV 96.3%, PPV 25.3% (AUC 0.748)

Result: Performance fell well below the derivation at the ≥15 threshold and the positive predictive value at ≥30 was only 25.3% despite 76.9% sensitivity — most high-risk general-population respondents did not have severe OSA. The authors support utility chiefly for ruling out severe OSA (NPV 96.3%).

Watch out: Every figure prints with its AHI threshold, cohort and reference device (home type 3 monitor here, portable monitoring in the derivation) — figures never travel without them.

Source: Tan A et al. Using the Berlin Questionnaire to Predict Obstructive Sleep Apnea in the General Population. Journal of Clinical Sleep Medicine. 2017. PMID: 27855742. Registry ID: none in the record. MeSH: Female · Humans · Male · Middle Aged · Reproducibility of Results · Sensitivity and Specificity · Singapore · Sleep Apnea, Obstructive/diagnosis · Surveys and Questionnaires/standards

Card 3 — Bivariate meta-analysis (108 studies, 47,989 participants, counted as a synthesis) — Berlin pooled sensitivity/specificity were 76%/59% for mild OSA (AHI/RDI ≥5), 77%/44% for moderate (≥15) and 84%/38% for severe (≥30): specificity COLLAPSES as the severity threshold rises; STOP-Bang was significantly more sensitive with lower specificity. NO Epworth figure is printed from this abstract — see watchOut

Study: Bivariate meta-analysis (synthesis — counted as a synthesis)

Population: Synthesis of 108 studies of the Berlin Questionnaire, STOP-Bang, STOP and Epworth Sleepiness Scale against AHI/RDI, with diagnostic odds ratios (labelled as such in the source): Berlin DOR 4.30 (mild), 2.68 (moderate), 3.10 (severe).

Summary: Bivariate meta-analysis (108 studies, 47,989 participants, counted as a synthesis) — Berlin pooled sensitivity/specificity were 76%/59% for mild OSA (AHI/RDI ≥5), 77%/44% for moderate (≥15) and 84%/38% for severe (≥30): specificity COLLAPSES as the severity threshold rises; STOP-Bang was significantly more sensitive with lower specificity. NO Epworth figure is printed from this abstract — see watchOut

Result: Berlin pooled pairs by severity as in the headline. OMISSION STATED ON THE FACE: this abstract prints the Epworth specificity for moderate OSA as an impossible three-digit percentage, an evident typographical error in the source — that figure is omitted here and no Epworth figure of any kind is printed from this abstract.

Watch out: Defective abstract: the defective Epworth specificity in this abstract must never be printed anywhere on this shelf. Only the Berlin limbs of this multi-instrument synthesis are carded here; STOP-Bang is homed at pack #7578 (preoperative slice) — cross-point, different instrument and population.

Source: Chiu HY et al. Diagnostic accuracy of the Berlin questionnaire, STOP-BANG, STOP, and Epworth sleepiness scale in detecting obstructive sleep apnea: A bivariate meta-analysis. Sleep Medicine Reviews. 2017. PMID: 27919588. Registry ID: none in the record. MeSH: Berlin · Humans · Sensitivity and Specificity · Sleep Apnea, Obstructive/diagnosis · Surveys and Questionnaires

Card 4 — Systematic review and meta-analysis (35 articles, all against type 1 polysomnography, counted as a synthesis) — accuracy varied by population, hypopnoea definition and AHI threshold, with good performance in sleep-clinic populations and relatively low specificity throughout; the abstract reports this pattern qualitatively and NO single pooled pair is printed from it

Study: Systematic review and meta-analysis (synthesis — counted as a synthesis)

Population: 35 eligible articles validating the Berlin Questionnaire against type 1 polysomnography, across sleep-clinic, clinical and general-population subgroups.

Summary: Systematic review and meta-analysis (35 articles, all against type 1 polysomnography, counted as a synthesis) — accuracy varied by population, hypopnoea definition and AHI threshold, with good performance in sleep-clinic populations and relatively low specificity throughout; the abstract reports this pattern qualitatively and NO single pooled pair is printed from it

Result: As published: the questionnaire is useful as a clinical screening and epidemiological tool in sleep-clinic populations, with modest-to-high sensitivity elsewhere on limited evidence and relatively low specificity. The authors recommend more consistent methodological definitions and more general-population work.

Watch out: A qualitative-pattern synthesis: inventing a pooled pair from it would misstate the source, so none is printed.

Source: Senaratna CV et al. Validity of the Berlin questionnaire in detecting obstructive sleep apnea: A systematic review and meta-analysis. Sleep Medicine Reviews. 2017. PMID: 28599983. Registry ID: none in the record. MeSH: Berlin · Humans · Mass Screening · Risk Factors · Sensitivity and Specificity · Sleep Apnea, Obstructive/diagnosis · Surveys and Questionnaires

Card 5 — Systematic review and meta-analysis by clinical cohort (38 studies, counted as a synthesis) — in the sleep-clinic cohort Berlin pooled sensitivity was 85%/84%/89% at AHI ≥5/≥15/≥30 with pooled specificity only 43%/30%/33%; in the surgical cohort at AHI ≥15, sensitivity 76% and specificity 47%; evidence certainty was low

Study: Systematic review and meta-analysis by cohort (synthesis — counted as a synthesis)

Population: 38 prospective polysomnography-validated studies across three clinical cohorts (sleep clinic, surgical, and other at-risk populations).

Summary: Systematic review and meta-analysis by clinical cohort (38 studies, counted as a synthesis) — in the sleep-clinic cohort Berlin pooled sensitivity was 85%/84%/89% at AHI ≥5/≥15/≥30 with pooled specificity only 43%/30%/33%; in the surgical cohort at AHI ≥15, sensitivity 76% and specificity 47%; evidence certainty was low

Result: The cohort split is the finding: sensitivity is highest where prevalence and referral enrichment are highest (sleep clinic), while specificity stays low in every cohort. The reviewers rate the certainty of the underlying data as low.

Watch out: Low certainty prints beside the pooled figures; this synthesis also covers STOP-Bang, carded here for its Berlin limb only (cross-point pack #7578).

Source: Bernhardt L et al. Diagnostic accuracy of screening questionnaires for obstructive sleep apnoea in adults in different clinical cohorts: a systematic review and meta-analysis. Sleep & Breathing. 2022. PMID: 34406554. Registry ID: none in the record. MeSH: Adult · Humans · Mass Screening · Polysomnography · Prospective Studies · Sleep Apnea, Obstructive · Surveys and Questionnaires

Card 6 — Synthesis: a screening-accuracy shelf, not a treatment shelf — no card implies Berlin-guided pathways improve outcomes. The population gradient is the content: derivation sensitivity 0.86 in enriched primary care (sleep-study subset 100 of 744) against 58.8% sensitivity at AHI ≥15 in the general population, and specificity collapsing with severity threshold in every synthesis (38% at ≥30 in the 108-study synthesis). Every figure carries its AHI threshold, cohort and reference device. The defective-abstract omission (the defective Epworth figure in PMID 27919588) is stated on that card and here: no Epworth figure is printed from that abstract anywhere on this shelf. Three of five anchors are syntheses, counted as syntheses. Cross-point: pack #7578 (STOP-Bang, preoperative) — different instrument, different population slice.

Study: Synthesis

Population: Synthesis of the reports carded above; no additional population.

Summary: Synthesis: a screening-accuracy shelf, not a treatment shelf — no card implies Berlin-guided pathways improve outcomes. The population gradient is the content: derivation sensitivity 0.86 in enriched primary care (sleep-study subset 100 of 744) against 58.8% sensitivity at AHI ≥15 in the general population, and specificity collapsing with severity threshold in every synthesis (38% at ≥30 in the 108-study synthesis). Every figure carries its AHI threshold, cohort and reference device. The defective-abstract omission (the defective Epworth figure in PMID 27919588) is stated on that card and here: no Epworth figure is printed from that abstract anywhere on this shelf. Three of five anchors are syntheses, counted as syntheses. Cross-point: pack #7578 (STOP-Bang, preoperative) — different instrument, different population slice.

Result: Balance: a sensitive, poorly specific screen whose accuracy is a property of the population it is used in.

Source: Synthesis of the reports carded above; no additional source.