SourceMed · Shelf #7860 in the ask interface

Meniscal tests for knee pain: FLOOR-RISK, exactly 2 syntheses — pooled figures in 2015 against 'little discriminative power' in 2001, on poor-quality primary literature

Shelf #7860 · Bones & joints

PREDICTIVE PERFORMANCE — FLOOR-RISK, exactly 2 syntheses: 2015 pooled McMurray 61% / 84%, joint-line tenderness 83% / 83%, Thessaly 75% / 87%, against the 2001 meta-analysis's conclusion of little discriminative power and little value for clinical practice; primary literature graded poor in both; a diagnostic-accuracy stamp, not a treatment stamp

Stamped: 2026-11-28.

Evidence published: 2001–2015.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In adults with knee pain, how accurately do the special tests for meniscal tears — McMurray's test, joint-line tenderness and the Thessaly test at 20° flexion — identify a torn meniscus against arthroscopy or MRI: what pooled sensitivity and specificity does the 2015 meta-analysis give each test, and why did the earlier meta-analysis conclude the tests have little discriminative power despite a favourable predictive value for a positive McMurray? (FLOOR-RISK base: exactly 2 syntheses, covering 9 and 13 primary studies respectively with overlapping primary sets — that exact basis prints on the face.)

Balance of the evidence

FLOOR-RISK — this shelf rests on exactly 2 syntheses (covering 9 and 13 primary studies respectively, with overlapping primary sets), and that exact basis prints here and on every card. The two syntheses disagree: usable pooled figures in the 2015 meta-analysis against 'little discriminative power / little value for clinical practice' in the 2001 meta-analysis, and neither prints as settled. Both syntheses grade their primary literature poor, which prints. This is a diagnostic-accuracy shelf, not a treatment shelf.

MeSH: Humans · Knee Injuries/diagnosis · Physical Examination/methods · Tibial Meniscus Injuries

Cards (4)

Card 1 — Meniscal FLOOR-RISK synthesis 1 of exactly 2 — 2015 meta-analysis (Smith 2015; 9 studies, 1,234 patients): McMurray sensitivity 61% and specificity 84%, joint-line tenderness 83% / 83%, and Thessaly at 20° 75% / 87% — with generally poor included-study quality and high heterogeneity

Study: Systematic review and meta-analysis (FLOOR-RISK synthesis 1 of exactly 2; primary-study sets overlap)

Population: Adults with knee pain assessed for meniscal tears against arthroscopy or MRI; 9 studies, 1,234 patients, three special tests meta-analysed. FLOOR-RISK report 1 of exactly 2 syntheses; primary sets overlap with the other synthesis.

Summary: Meniscal FLOOR-RISK synthesis 1 of exactly 2 — 2015 meta-analysis (Smith 2015; 9 studies, 1,234 patients): McMurray sensitivity 61% and specificity 84%, joint-line tenderness 83% / 83%, and Thessaly at 20° 75% / 87% — with generally poor included-study quality and high heterogeneity

Result: McMurray's test: sensitivity 61% (95% CI 45% to 74%) and specificity 84% (69% to 92%). Joint-line tenderness: sensitivity 83% (73% to 90%) and specificity 83% (61% to 94%). Thessaly test at 20° flexion: sensitivity 75% (53% to 89%) and specificity 87% (65% to 96%). The authors conclude accuracy remains poor and results should be used with caution, due to poor quality, low study numbers and high heterogeneity.

Watch out: FLOOR-RISK: exactly 2 syntheses form the whole base. The pooled figures come with poor primary quality and high heterogeneity — never print them as settled.

Source: Smith BE et al. Special tests for assessing meniscal tears within the knee: a systematic review and meta-analysis. Evidence-based medicine. 2015. PMID: 25724195. Registry ID: none in the record. MeSH: Humans · Knee Injuries/diagnosis · Physical Examination/methods · Tibial Meniscus Injuries

Card 2 — Meniscal FLOOR-RISK synthesis 2 of exactly 2 — 2001 meta-analysis (Scholten 2001; 13 studies): the summary ROC curves for joint effusion, McMurray and joint-line tenderness indicated little discriminative power, with only the predictive value of a positive McMurray favourable

Study: Meta-analysis (FLOOR-RISK synthesis 2 of exactly 2; primary-study sets overlap)

Population: Studies of physical diagnostic tests for meniscus injury against arthrotomy, arthroscopy or MRI; 13 studies met inclusion. Index and reference tests were assessed independently in only 2 studies and verification bias seemed present in all. FLOOR-RISK report 2 of exactly 2 syntheses; primary sets overlap with the other synthesis.

Summary: Meniscal FLOOR-RISK synthesis 2 of exactly 2 — 2001 meta-analysis (Scholten 2001; 13 studies): the summary ROC curves for joint effusion, McMurray and joint-line tenderness indicated little discriminative power, with only the predictive value of a positive McMurray favourable

Result: The summary receiver operating characteristic curves for joint effusion, the McMurray test and joint-line tenderness indicated little discriminative power. Only the predictive value of a positive McMurray test was favourable. The authors conclude the methodologic quality was poor, results were highly heterogeneous, and these tests are of little value for clinical practice.

Watch out: FLOOR-RISK: exactly 2 syntheses form the whole base. This synthesis's 'little value' verdict is part of the content and may not be omitted beside the 2015 pooled figures.

Source: Scholten RJ et al. The accuracy of physical diagnostic tests for assessing meniscal lesions of the knee: a meta-analysis. The Journal of family practice. 2001. PMID: 11711009. Registry ID: none in the record. MeSH: Arthroscopy/standards · Bias · Data Interpretation, Statistical · Discriminant Analysis · Evidence-Based Medicine · Exudates and Transudates · Humans · Likelihood Functions · Magnetic Resonance Imaging/standards · Pain Measurement/methods,standards · Physical Examination/methods,standards · Practice Guidelines as Topic · Prevalence · Reproducibility of Results · Research Design/standards · Sensitivity and Specificity · Tibial Meniscus Injuries

Card 3 — Meniscal cross-synthesis comparison — not an additional report: the 2015 pooled figures and the 2001 'little discriminative power' conclusion come from overlapping, poor-quality primary literatures, so the disagreement itself is the finding (source line repeats the 2015 synthesis for reference)

Study: Cross-synthesis summary of the two carded syntheses — not an additional report (source line repeats synthesis 1 for reference)

Population: The two carded syntheses only: Smith 2015 (9 studies, 1,234 patients) and Scholten 2001 (13 studies). This card adds no report and no data; the base remains exactly 2 syntheses.

Summary: Meniscal cross-synthesis comparison — not an additional report: the 2015 pooled figures and the 2001 'little discriminative power' conclusion come from overlapping, poor-quality primary literatures, so the disagreement itself is the finding (source line repeats the 2015 synthesis for reference)

Result: Where the syntheses agree: primary-study quality is poor and heterogeneity is high in both. Where they differ: 2015 prints pooled sensitivity/specificity pairs for McMurray, joint-line tenderness and Thessaly; 2001, on its summary ROC analysis, finds little discriminative power except a favourable predictive value for a positive McMurray. No figure from either may be presented as resolving the other.

Watch out: FLOOR-RISK base remains exactly 2 syntheses — this comparison card must never be counted as a third source.

Source: Smith BE et al. Special tests for assessing meniscal tears within the knee: a systematic review and meta-analysis. Evidence-based medicine. 2015. PMID: 25724195. Registry ID: none in the record. MeSH: Humans · Knee Injuries/diagnosis · Physical Examination/methods · Tibial Meniscus Injuries

Card 4 — Synthesis: FLOOR-RISK — exactly 2 syntheses with overlapping primary sets, both grading that literature poor, disagree on whether meniscal special tests discriminate at all (2015 pooled pairs vs 2001 'little value for clinical practice'); neither reading is settled

Study: Synthesis

Population: All reports carded on this shelf: Smith 2015 and Scholten 2001 — exactly 2 syntheses, covering 9 and 13 primary studies respectively with overlapping sets.

Summary: Synthesis: FLOOR-RISK — exactly 2 syntheses with overlapping primary sets, both grading that literature poor, disagree on whether meniscal special tests discriminate at all (2015 pooled pairs vs 2001 'little value for clinical practice'); neither reading is settled

Result: No card on this shelf presents McMurray, joint-line tenderness or Thessaly as a stand-alone diagnostic test, and none implies test-guided pathways improve outcomes.

Watch out: See the individual cards for each synthesis's limits; this synthesis adds no new data.

Source: Synthesis of the reports carded above; no additional source.