Shoulder examination tests: 4 overlapping syntheses — no single test performs superiorly, SLAP tests barely discriminate, and Cochrane would not pool
Shelf #7861 · Bones & joints
PREDICTIVE PERFORMANCE — limited for single tests: 4 overlapping syntheses, counted as syntheses only — pooled SLAP tests DOR 1.38 (labelled as such), best single-test DOR 9.24 for supraspinatus / full-thickness tear, impingement tests better at ruling out than in, and the Cochrane review declined to pool; a diagnostic-accuracy stamp, not a treatment stamp
Stamped: 2026-11-28.
Evidence published: 2012–2024.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients with shoulder pain, how accurately do the bedside shoulder examination tests — Hawkins–Kennedy, Neer's sign, the empty-can / supraspinatus tests, drop-arm, lift-off and the lag signs, and the SLAP-lesion tests — identify subacromial impingement, rotator-cuff tears and labral lesions against arthroscopy, surgery or imaging: which tests rule out and which rule in, what pooled diagnostic odds ratios do the meta-analyses assign, and why did the Cochrane review decline to meta-analyse at all? (Base: 4 syntheses whose primary-study sets overlap — counted as syntheses, never as independent cohorts.)
Balance of the evidence
This shelf rests on 4 syntheses whose primary-study sets overlap — the count prints as 4 syntheses, never as independent cohorts. The Cochrane review's refusal to pool (170 target-condition / index-test combinations, only six instances of any test performed similarly in two studies) is itself a headline finding and prints beside the pooled figures from the other three. Target conditions differ across syntheses (impingement vs rotator-cuff tear vs SLAP lesion) and no figure prints without its target condition and reference standard; arthroscopy-selected spectra dominate. Diagnostic odds ratios are labelled as such wherever printed. This is a diagnostic-accuracy shelf, not a treatment shelf.
MeSH: Humans · Physical Examination/methods,standards · Shoulder Impingement Syndrome/diagnosis,physiopathology · Shoulder Pain/diagnosis,physiopathology
Cards (5)
Card 1 — Shoulder synthesis 1 of 4 — test-performance meta-analysis (Gismervik 2017; 20 eligible articles, 11 meta-analysed): pooled SLAP-lesion tests gave a diagnostic odds ratio of only 1.38, the supraspinatus test for full-thickness cuff tear had the highest single-test DOR at 9.24, compression-rotation was the best SLAP test (6.36) and Hawkins the best impingement test (2.86)
Study: Systematic review and meta-analysis (synthesis 1 of 4; primary-study sets overlap across the four syntheses)
Population: Patients with shoulder complaints; 20 eligible articles, data from 11 in the meta-analysis, against reference standards in the primary studies. One of 4 overlapping syntheses — never an independent cohort.
Summary: Shoulder synthesis 1 of 4 — test-performance meta-analysis (Gismervik 2017; 20 eligible articles, 11 meta-analysed): pooled SLAP-lesion tests gave a diagnostic odds ratio of only 1.38, the supraspinatus test for full-thickness cuff tear had the highest single-test DOR at 9.24, compression-rotation was the best SLAP test (6.36) and Hawkins the best impingement test (2.86)
Result: All SLAP-lesion tests pooled: diagnostic odds ratio (labelled as such) 1.38 (95% CI 1.13 to 1.69). Supraspinatus test for any full-thickness rotator-cuff tear: DOR 9.24, sensitivity 0.74, specificity 0.77. Compression-rotation test for SLAP lesions: DOR 6.36, sensitivity 0.43, specificity 0.89. Hawkins test for impingement: DOR 2.86, sensitivity 0.58, specificity 0.67. No single test showed superior clinical performance.
Watch out: A DOR of 1.38 for pooled SLAP tests is close to no discrimination — do not convert DOR rankings into claims that any single test diagnoses a SLAP lesion.
Source: Gismervik SØ et al. Physical examination tests of the shoulder: a systematic review and meta-analysis of diagnostic test performance. BMC musculoskeletal disorders. 2017. PMID: 28122541. Registry ID: none in the record. MeSH: Humans · Physical Examination/methods,standards · Shoulder Impingement Syndrome/diagnosis,physiopathology · Shoulder Pain/diagnosis,physiopathology
Card 2 — Shoulder synthesis 2 of 4 — impingement meta-analysis (Alqunaee 2012; 10 studies, 1,684 patients against arthroscopy or open surgery): Hawkins–Kennedy, Neer and empty-can were more useful for ruling out (sensitivities 0.69–0.78, specificities 0.57–0.62), while drop-arm and lift-off were more useful for ruling in (specificities 0.92–0.97, sensitivities 0.21–0.42)
Study: Systematic review and meta-analysis for subacromial impingement (synthesis 2 of 4; primary-study sets overlap)
Population: Individuals with a painful shoulder in studies using arthroscopy or open surgery as the reference standard; 10 studies, 1,684 patients in the meta-analysis. One of 4 overlapping syntheses — never an independent cohort.
Summary: Shoulder synthesis 2 of 4 — impingement meta-analysis (Alqunaee 2012; 10 studies, 1,684 patients against arthroscopy or open surgery): Hawkins–Kennedy, Neer and empty-can were more useful for ruling out (sensitivities 0.69–0.78, specificities 0.57–0.62), while drop-arm and lift-off were more useful for ruling in (specificities 0.92–0.97, sensitivities 0.21–0.42)
Result: Hawkins–Kennedy, Neer's sign and the empty-can test: pooled sensitivities 0.69–0.78 and specificities 0.57–0.62 — more useful for ruling out subacromial impingement; a negative Neer reduced the probability of impingement from 45% to 14%. Drop-arm and lift-off tests: pooled specificities 0.92–0.97 and sensitivities 0.21–0.42 — more useful for ruling in when positive.
Watch out: The reference standard is surgery, so these are surgical-spectrum figures — they do not describe primary-care shoulder pain.
Source: Alqunaee M et al. Diagnostic accuracy of clinical tests for subacromial impingement syndrome: a systematic review and meta-analysis. Archives of physical medicine and rehabilitation. 2012. PMID: 22289231. Registry ID: none in the record. MeSH: Humans · Muscle Weakness/diagnosis · Pain Measurement/methods · Physical Examination/methods · ROC Curve · Sensitivity and Specificity · Shoulder Impingement Syndrome/diagnosis
Card 3 — Shoulder synthesis 3 of 4 — 2024 meta-analysis (Zhao 2024; 20 studies, 3,438 patients): six tests had significant diagnostic odds ratios for rotator-cuff tears, the external-rotation lag sign at 90° highest (DOR 12.70), and four for impingement, Yergason's highest (DOR 4.71); the authors grade the body of evidence low quality
Study: Systematic review and meta-analysis (synthesis 3 of 4; primary-study sets overlap)
Population: Patients evaluated for rotator-cuff tears or subacromial impingement / bursitis; 20 studies, 3,438 patients; meta-analyses performed on 10 tests for cuff tears and 5 for impingement. One of 4 overlapping syntheses — never an independent cohort.
Summary: Shoulder synthesis 3 of 4 — 2024 meta-analysis (Zhao 2024; 20 studies, 3,438 patients): six tests had significant diagnostic odds ratios for rotator-cuff tears, the external-rotation lag sign at 90° highest (DOR 12.70), and four for impingement, Yergason's highest (DOR 4.71); the authors grade the body of evidence low quality
Result: For rotator-cuff tears, six tests had significant diagnostic odds ratios (labelled as such), the external-rotation lag sign at 90° highest at 12.70 (95% CI 3.68 to 43.86). For impingement, four tests had significant DORs, Yergason's test highest at 4.71 (2.16 to 10.32). The authors present this as a large body of low-quality evidence.
Watch out: The highest DOR carries a very wide interval (3.68 to 43.86) on low-quality evidence — a ranking, not a precise estimate.
Source: Zhao Q et al. Evidence-based approach to the shoulder examination for subacromial bursitis and rotator cuff tears: a systematic review and meta-analysis. BMC musculoskeletal disorders. 2024. PMID: 39702033. Registry ID: none in the record. MeSH: Humans · Bursitis/complications,diagnosis,physiopathology · Evidence-Based Medicine · Physical Examination/methods · Rotator Cuff Injuries/complications,diagnosis,physiopathology · Shoulder Impingement Syndrome/complications,diagnosis,physiopathology · Shoulder Joint/physiopathology · Shoulder Pain/diagnosis,etiology,physiopathology
Card 4 — Shoulder synthesis 4 of 4 — Cochrane diagnostic-accuracy review (Hanchard 2013; 33 studies, 4,002 shoulders) declined to meta-analyse at all: 170 target-condition / index-test combinations with only six instances of any test performed and interpreted similarly in two studies, surgical reference standards in most studies and unrepresentative spectra in all but two
Study: Cochrane diagnostic-accuracy review (synthesis 4 of 4; primary-study sets overlap)
Population: People whose symptoms suggest shoulder impingement or local lesions of bursa, tendon or labrum; 33 studies, 4,002 shoulders in 3,852 patients, mostly against arthroscopic surgery. One of 4 overlapping syntheses — never an independent cohort.
Summary: Shoulder synthesis 4 of 4 — Cochrane diagnostic-accuracy review (Hanchard 2013; 33 studies, 4,002 shoulders) declined to meta-analyse at all: 170 target-condition / index-test combinations with only six instances of any test performed and interpreted similarly in two studies, surgical reference standards in most studies and unrepresentative spectra in all but two
Result: Meta-analysis was judged inappropriate: extreme diversity in how tests were performed and interpreted hindered synthesis. Individual-study sensitivities and specificities are presented without pooling across 170 combinations. The authors conclude there is insufficient evidence on which to base selection of physical tests for these conditions in primary care.
Watch out: This refusal to pool is a headline finding, not a missing result — it limits how far the pooled DORs on the other cards can be taken.
Source: Hanchard NC et al. Physical tests for shoulder impingements and local lesions of bursa, tendon or labrum that may accompany impingement. The Cochrane database of systematic reviews. 2013. PMID: 23633343. Registry ID: none in the record. MeSH: Arthroscopy · Bursa, Synovial/injuries · Bursitis/diagnosis · Glenoid Cavity · Humans · Joint Instability/diagnosis · Physical Examination/methods · Prospective Studies · Randomized Controlled Trials as Topic · Rotator Cuff Injuries · Rupture/diagnosis · Shoulder Impingement Syndrome/diagnosis · Tendinopathy/diagnosis
Card 5 — Synthesis: 4 overlapping syntheses — counted as syntheses, never as independent cohorts — find no single shoulder test with superior performance: some tests help rule out impingement, a few help rule in cuff tears, SLAP tests barely discriminate, and the Cochrane review would not pool at all
Study: Synthesis
Population: All syntheses carded on this shelf: Gismervik 2017, Alqunaee 2012, Zhao 2024 and Hanchard 2013 (Cochrane). Their primary-study sets overlap; the count is 4 syntheses.
Summary: Synthesis: 4 overlapping syntheses — counted as syntheses, never as independent cohorts — find no single shoulder test with superior performance: some tests help rule out impingement, a few help rule in cuff tears, SLAP tests barely discriminate, and the Cochrane review would not pool at all
Result: No figure prints without its target condition (impingement vs cuff tear vs SLAP lesion) and reference standard, and no card implies examination-guided pathways improve outcomes.
Watch out: See the individual cards for each synthesis's limits; this synthesis adds no new data.
Source: Synthesis of the reports carded above; no additional source.