SourceMed · Shelf #7862 in the ask interface

Cervical radiculopathy tests: Spurling is specific but insensitive — and its sensitivity halves against electrodiagnosis vs imaging; the Wainner cluster is a wide-interval derivation

Shelf #7862 · Bones & joints

PREDICTIVE PERFORMANCE — specific, not sensitive, for Spurling: 1 primary study + 3 overlapping syntheses — Spurling pooled 0.53 / 0.92 (sensitivity 0.67 vs imaging, 0.31 vs electrodiagnosis), Wainner four-item cluster positive likelihood ratio 30.3 (labelled as such, wide intervals, N = 82); strength / reflex / sensory accuracy unstudied; a diagnostic-accuracy stamp, not a treatment stamp

Stamped: 2026-11-28.

Evidence published: 2003–2025.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In patients with neck and arm pain, how accurately do the cervical-radiculopathy examination tests — Spurling's test, the upper-limb tension / neurodynamic tests, neck distraction / traction, Valsalva and the shoulder-abduction test, alone and in the Wainner test-item cluster — identify cervical radiculopathy against imaging, electrodiagnosis or surgical findings: what pooled sensitivity and specificity does the 2025 meta-analysis give Spurling's test, how does its accuracy split by reference standard, and what likelihood ratio did the derivation cluster achieve? (Base: 1 primary study + 3 syntheses whose primary sets overlap, the Wainner cohort inside the later reviews.)

Balance of the evidence

This shelf rests on 1 primary study + 3 syntheses whose primary sets overlap (the Wainner cohort sits inside the later reviews) — that composition prints on the face. The reference-standard split is the content: Spurling sensitivity 0.67 against imaging vs 0.31 against electrodiagnosis, and no pooled figure prints without its standard. The evidence hole prints as a finding: strength, reflex and sensory testing — the everyday neurological examination — had no verified accuracy literature in the 2018 review. This is a diagnostic-accuracy shelf, not a treatment shelf. Cross-point: pack #7815 asks straight-leg raising for lumbar radiculopathy — a different region and test set.

MeSH: Adult · Diagnostic Techniques, Neurological/standards,statistics & numerical data · Electrodiagnosis · Electromyography · Female · Health Status · Humans · Likelihood Functions · Male · Middle Aged · Neck · Neurologic Examination/methods,standards · Predictive Value of Tests · Prospective Studies · Radiculopathy/classification,diagnosis · Range of Motion, Articular · Reproducibility of Results · Self Efficacy · Surveys and Questionnaires · United States

Cards (5)

Card 1 — Cervical primary report — Wainner cluster derivation (Wainner 2003; blinded prospective study, 82 patients against an electrophysiological reference): the four-item cluster (Spurling, distraction, upper-limb tension and cervical rotation) produced a positive likelihood ratio of 30.3 with wide confidence intervals, and upper-limb tension test A was the most useful rule-out item — programme-labelled: the Wainner group's own report

Study: Blinded prospective diagnostic study (the 1 primary report; programme-labelled — the Wainner group's own report)

Population: 82 patients with suspected cervical radiculopathy or carpal tunnel syndrome, assessed against an electrophysiological (neural impairment) reference standard by examiners blinded to diagnosis. The single primary study on this shelf; it sits inside the later syntheses.

Summary: Cervical primary report — Wainner cluster derivation (Wainner 2003; blinded prospective study, 82 patients against an electrophysiological reference): the four-item cluster (Spurling, distraction, upper-limb tension and cervical rotation) produced a positive likelihood ratio of 30.3 with wide confidence intervals, and upper-limb tension test A was the most useful rule-out item — programme-labelled: the Wainner group's own report

Result: More than two-thirds of 34 examination items reached at least fair reliability, and 13 items had likelihood ratio point estimates above 2 or below 0.50 (likelihood ratios labelled as such). The four-variable test-item cluster produced a positive likelihood ratio point estimate of 30.3; the 95% confidence intervals for all likelihood ratio estimates in this study were wide. Upper limb tension Test A was the most useful test for ruling out cervical radiculopathy.

Watch out: The cluster likelihood ratio of 30.3 comes from 82 patients with wide intervals throughout — it is a derivation result needing validation, as its authors state, not a settled rule-in.

Source: Wainner RS et al. Reliability and diagnostic accuracy of the clinical examination and patient self-report measures for cervical radiculopathy. Spine. 2003. PMID: 12544957. Registry ID: none in the record. MeSH: Adult · Diagnostic Techniques, Neurological/standards,statistics & numerical data · Electrodiagnosis · Electromyography · Female · Health Status · Humans · Likelihood Functions · Male · Middle Aged · Neck · Neurologic Examination/methods,standards · Predictive Value of Tests · Prospective Studies · Radiculopathy/classification,diagnosis · Range of Motion, Articular · Reproducibility of Results · Self Efficacy · Surveys and Questionnaires · United States

Card 2 — Cervical synthesis 1 of 3 — Spurling meta-analysis (Lin 2025; 8 studies): pooled sensitivity 0.53 and specificity 0.92, splitting by reference standard to sensitivity 0.67 against imaging vs 0.31 against electrodiagnosis, with pooled positive and negative likelihood ratios of 3.28 and 0.28

Study: Systematic review and meta-analysis of Spurling's test (synthesis 1 of 3; primary-study sets overlap)

Population: Studies assessing Spurling's test for subacute and chronic cervical radiculopathy against imaging or electrodiagnostic tests; 8 studies in a bivariate random-effects pool. One of 3 overlapping syntheses — never an independent cohort.

Summary: Cervical synthesis 1 of 3 — Spurling meta-analysis (Lin 2025; 8 studies): pooled sensitivity 0.53 and specificity 0.92, splitting by reference standard to sensitivity 0.67 against imaging vs 0.31 against electrodiagnosis, with pooled positive and negative likelihood ratios of 3.28 and 0.28

Result: Pooled sensitivity 0.53 (95% CI 0.29 to 0.78) and specificity 0.92 (0.88 to 0.96). By reference standard, sensitivity was 0.67 with imaging and 0.31 with electrodiagnostic testing (specificity 0.93 and 0.91 respectively). Pooled positive likelihood ratio 3.28 and negative likelihood ratio 0.28 (labelled as such); log diagnostic odds ratio 2.74. Combining neck rotation or extension raised sensitivity to 0.67 vs 0.31 without those manoeuvres. The authors conclude the test is better suited to confirmation than screening.

Watch out: Never print the pooled 0.53 sensitivity without its reference-standard split — the same test reads 0.67 or 0.31 depending on the standard.

Source: Lin LH et al. Diagnostic Performance of Spurling's Test for the Assessment Subacute and Chronic Cervical Radiculopathy: A Systematic Review and Meta-analysis. American journal of physical medicine & rehabilitation. 2025. PMID: 39938056. Registry ID: none in the record. MeSH: Humans · Radiculopathy/diagnosis · Sensitivity and Specificity · Chronic Disease · Cervical Vertebrae · Physical Examination/methods · Electrodiagnosis

Card 3 — Cervical synthesis 2 of 3 — physical-tests review (Thoomes 2018; 5 diagnostic-accuracy studies): only Spurling's test was evaluated in more than one study (specificity 0.89–1.00, sensitivity 0.38–0.97 across studies), and no studies were found assessing the widely used neurological tests — key-muscle strength, tendon reflexes or sensory examination

Study: Systematic review (synthesis 2 of 3; primary-study sets overlap)

Population: Diagnostic-accuracy studies comparing physical-examination tests for cervical radiculopathy with imaging or surgical findings; 5 studies identified to March 2016. One of 3 overlapping syntheses — never an independent cohort.

Summary: Cervical synthesis 2 of 3 — physical-tests review (Thoomes 2018; 5 diagnostic-accuracy studies): only Spurling's test was evaluated in more than one study (specificity 0.89–1.00, sensitivity 0.38–0.97 across studies), and no studies were found assessing the widely used neurological tests — key-muscle strength, tendon reflexes or sensory examination

Result: Only Spurling's test appeared in more than one study, with high specificity ranging 0.89 to 1.00 (95% CI 0.59 to 1.00) and sensitivity varying 0.38 to 0.97 (0.21 to 0.99). No studies were found assessing the diagnostic accuracy of key-muscle strength, tendon reflexes or sensory impairments. The authors suggest combinations (Spurling, axial traction and Arm Squeeze to raise likelihood; combined negative neurodynamic tests plus Arm Squeeze to rule out) on limited evidence.

Watch out: The absence of any accuracy study for strength, reflex and sensory testing is a finding of this shelf — do not fill it with assumed performance.

Source: Thoomes EJ et al. Value of physical tests in diagnosing cervical radiculopathy: a systematic review. The spine journal : official journal of the North American Spine Society. 2018. PMID: 28838857. Registry ID: none in the record. MeSH: Cervical Vertebrae/pathology · Humans · Neurologic Examination/methods,standards · Radiculopathy/diagnosis · Sensitivity and Specificity

Card 4 — Cervical synthesis 3 of 3 — provocative-tests review (Rubinstein 2007; 6 studies of 5 tests): Spurling, traction / distraction and Valsalva showed low-to-moderate sensitivity with high specificity, the upper-limb tension test high sensitivity with low specificity, and methodological flaws precluded meta-analysis

Study: Systematic review (synthesis 3 of 3; primary-study sets overlap)

Population: Studies of provocative neck tests for cervical radiculopathy reporting sensitivity and specificity against any reference standard; 6 studies evaluating 5 tests. One of 3 overlapping syntheses — never an independent cohort.

Summary: Cervical synthesis 3 of 3 — provocative-tests review (Rubinstein 2007; 6 studies of 5 tests): Spurling, traction / distraction and Valsalva showed low-to-moderate sensitivity with high specificity, the upper-limb tension test high sensitivity with low specificity, and methodological flaws precluded meta-analysis

Result: In general, Spurling's test, traction / neck distraction and Valsalva showed low-to-moderate sensitivity and high specificity; the upper-limb tension test showed high sensitivity and low specificity; the shoulder-abduction test showed low-to-moderate sensitivity and moderate-to-high specificity. Common flaws included lack of an optimal reference standard, spectrum bias and review bias, so no meta-analysis was conducted and no firm conclusions were drawn, especially for primary care.

Watch out: This review's refusal to pool, on methodological flaws, limits the pooled Spurling figures on the neighbouring card.

Source: Rubinstein SM et al. A systematic review of the diagnostic accuracy of provocative tests of the neck for diagnosing cervical radiculopathy. European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society. 2007. PMID: 17013656. Registry ID: none in the record. MeSH: Diagnostic Tests, Routine/methods · Humans · Prognosis · Radiculopathy/classification,diagnosis · Reference Standards · Sensitivity and Specificity

Card 5 — Synthesis: 1 primary study + 3 overlapping syntheses — counted as that composition, never as four independent confirmations — agree Spurling is specific but insensitive, with its sensitivity split by reference standard (0.67 imaging vs 0.31 electrodiagnosis), the Wainner cluster promising but imprecise, and the everyday neurological examination unstudied for accuracy

Study: Synthesis

Population: All reports carded on this shelf: Wainner 2003 (82 patients, the derivation cohort) plus Lin 2025, Thoomes 2018 and Rubinstein 2007, whose primary sets overlap and include the Wainner cohort.

Summary: Synthesis: 1 primary study + 3 overlapping syntheses — counted as that composition, never as four independent confirmations — agree Spurling is specific but insensitive, with its sensitivity split by reference standard (0.67 imaging vs 0.31 electrodiagnosis), the Wainner cluster promising but imprecise, and the everyday neurological examination unstudied for accuracy

Result: No pooled figure prints without its reference standard, and no card implies test-guided pathways improve outcomes. Cross-point: lumbar straight-leg raising is pack #7815.

Watch out: See the individual cards for each report's limits; this synthesis adds no new data.

Source: Synthesis of the reports carded above; no additional source.