SourceMed · Shelf #7864 in the ask interface

Scaphoid fracture tests: 3 overlapping syntheses — snuffbox tenderness is sensitive, nothing is specific enough alone, and no feature excludes an occult fracture

Shelf #7864 · Bones & joints

PREDICTIVE PERFORMANCE — sensitive, not specific: 3 overlapping syntheses, counted as syntheses only — pooled snuffbox tenderness 0.93 sensitive but axial-loading specificity only 0.66, specificity ranges as wide as 0.03–0.98, and no single feature excludes an occult fracture; a diagnostic-accuracy stamp, not a treatment stamp

Stamped: 2026-11-28.

Evidence published: 2014–2023.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In patients with suspected scaphoid fracture, how accurately do the clinical tests — anatomical-snuffbox tenderness, scaphoid-tubercle tenderness, longitudinal thumb compression / axial loading and resisted supination — identify scaphoid fracture against radiography, MRI or follow-up, both when the initial radiograph is abnormal and when it is normal: what sensitivity and specificity ranges do the reviews report for each test, what pooled estimates does the Bayesian meta-analysis give, and which single feature best predicts an occult fracture? (Base: 3 syntheses whose primary-study sets overlap — counted as syntheses, never as independent cohorts.)

Balance of the evidence

This shelf rests on 3 syntheses whose primary-study sets overlap — the count prints as 3 syntheses, never as independent cohorts. The two clinical slices are different questions (any suspected fracture vs the radiograph-negative occult slice, prevalence 9.0%) and their figures never mix. The standout single-study predictor (resisted supination, positive likelihood ratio 45.0, labelled as such) is explicitly unvalidated externally and prints as single-study. The specificity ranges are so wide (0.03–0.98 for snuffbox tenderness) that no pooled specificity is headlined for it. This is a diagnostic-accuracy shelf: no card implies a test-based discharge pathway is safe without imaging follow-up, which is the syntheses' own caution.

MeSH: Diagnostic Imaging · Fractures, Bone/diagnosis · Humans · Scaphoid Bone/injuries · Sensitivity and Specificity

Cards (4)

Card 1 — Scaphoid synthesis 1 of 3 — clinical-evaluation review and meta-analysis (Mallee 2014; 13 articles, 25 tests): anatomical-snuffbox tenderness (8 studies, 1,164 patients) had sensitivity 0.87–1.00 with specificity 0.03–0.98 across studies, and longitudinal thumb compression (8 studies, 961 patients) sensitivity 0.48–1.00 and specificity 0.22–0.97; heterogeneity precluded pooled estimates

Study: Systematic review and meta-analysis (synthesis 1 of 3; primary-study sets overlap across the three syntheses)

Population: Patients with suspected scaphoid fracture, tested clinically before radiographic evaluation, against an acceptable reference standard for occult fractures; 13 articles describing 25 tests, 12 prospective and 1 retrospective. One of 3 overlapping syntheses — never an independent cohort.

Summary: Scaphoid synthesis 1 of 3 — clinical-evaluation review and meta-analysis (Mallee 2014; 13 articles, 25 tests): anatomical-snuffbox tenderness (8 studies, 1,164 patients) had sensitivity 0.87–1.00 with specificity 0.03–0.98 across studies, and longitudinal thumb compression (8 studies, 961 patients) sensitivity 0.48–1.00 and specificity 0.22–0.97; heterogeneity precluded pooled estimates

Result: Anatomical snuff-box tenderness and longitudinal thumb compression had sufficient data for analysis but considerable heterogeneity, so pooled estimate points were not calculated; the figures above are ranges across studies. Scaphoid-tubercle tenderness ranged in sensitivity 0.82–1.00 and specificity 0.17–0.57, and painful ulnar deviation 0.67–1.00 and 0.17–0.60. Three studies showed combining tests increased specificity and post-test fracture probability while maintaining high sensitivity. Quality assessment showed high or unclear risk of bias in reference standard and patient selection.

Watch out: These are ranges, not pooled estimates — the 0.03 lower bound for snuffbox specificity is part of the result and may not be trimmed.

Source: Mallee WH et al. Clinical diagnostic evaluation for scaphoid fractures: a systematic review and meta-analysis. The Journal of hand surgery. 2014. PMID: 25091335. Registry ID: none in the record. MeSH: Diagnostic Imaging · Fractures, Bone/diagnosis · Humans · Scaphoid Bone/injuries · Sensitivity and Specificity

Card 2 — Scaphoid synthesis 2 of 3 — occult-fracture review restricted to normal initial radiographs (Coventry 2023; 8 studies, 1,685 wrist injuries, occult-fracture prevalence 9.0%): the most accurate predictor was pain on resisted pronation-to-supination (sensitivity 100%, specificity 97.9%, positive likelihood ratio 45.0, from a single study), absence of snuffbox tenderness reduced fracture likelihood (negative likelihood ratio 0.2), and no single feature satisfactorily excludes an occult fracture

Study: Systematic review of the radiograph-negative (occult) slice (synthesis 2 of 3; primary-study sets overlap)

Population: Patients with clinical suspicion of scaphoid injury and normal initial radiographs; 8 studies, 1,685 wrist injuries; most at low risk of bias, two at unclear risk. The review's registration is stated in its record as CRD42021290224. One of 3 overlapping syntheses — never an independent cohort.

Summary: Scaphoid synthesis 2 of 3 — occult-fracture review restricted to normal initial radiographs (Coventry 2023; 8 studies, 1,685 wrist injuries, occult-fracture prevalence 9.0%): the most accurate predictor was pain on resisted pronation-to-supination (sensitivity 100%, specificity 97.9%, positive likelihood ratio 45.0, from a single study), absence of snuffbox tenderness reduced fracture likelihood (negative likelihood ratio 0.2), and no single feature satisfactorily excludes an occult fracture

Result: Pain when the examiner moved the wrist from pronated to supinated against resistance: sensitivity 100%, specificity 97.9%, positive likelihood ratio 45.0 (95% CI 6.5 to 312.5, labelled as such) — from a single study, needing external validation, as the authors state. Supination strength under 10% of the other side: sensitivity 84.6%, specificity 76.9%, LR+ 3.7. Absence of anatomical-snuffbox tenderness significantly reduced the likelihood of an occult fracture (negative likelihood ratio 0.2, 0.0 to 0.7). The authors conclude no single feature satisfactorily excludes an occult scaphoid fracture.

Watch out: This slice's 9.0% prevalence and its figures belong only to radiograph-negative patients — never mix them with the all-comers figures on the neighbouring cards. The LR+ 45.0 is single-study and unvalidated.

Source: Coventry L et al. Which clinical features best predict occult scaphoid fractures? A systematic review of diagnostic test accuracy studies. Emergency medicine journal : EMJ. 2023. PMID: 37169546. Registry ID: none in the record. MeSH: Scaphoid Bone · Diagnosis, Differential · Fractures, Bone/complications,diagnosis · Diagnostic Tests, Routine · Humans · Pain/etiology · Hand Injuries/complications,diagnosis

Card 3 — Scaphoid synthesis 3 of 3 — Bayesian meta-analysis (Huynh 2021; 14 articles, 1,940 patients): pooled snuffbox pain / tenderness was the most sensitive test (0.93) and pain with axial loading the most specific (0.66); with all three classic findings present at a 20% prevalence the post-test fracture probability was approximately 60%

Study: Systematic review, meta-analysis and Bayesian decision analysis (synthesis 3 of 3; primary-study sets overlap)

Population: Patients evaluated for scaphoid fracture with 22 index tests across 14 articles, 1,940 patients; pooled analysis was possible for snuffbox pain/tenderness (11 studies, 1,363 patients), pain with axial loading (8 studies, 995) and scaphoid-tubercle tenderness (5 studies, 953). One of 3 overlapping syntheses — never an independent cohort.

Summary: Scaphoid synthesis 3 of 3 — Bayesian meta-analysis (Huynh 2021; 14 articles, 1,940 patients): pooled snuffbox pain / tenderness was the most sensitive test (0.93) and pain with axial loading the most specific (0.66); with all three classic findings present at a 20% prevalence the post-test fracture probability was approximately 60%

Result: Anatomical snuffbox pain/tenderness was the most sensitive test (pooled 0.93, 95% CI 0.87 to 0.97) and pain with axial loading the most specific (0.66, 0.41 to 0.85); all three pooled tests had lower specificities than sensitivities. In the base case at a 20% fracture prevalence, a patient with all three findings (snuffbox pain/tenderness, pain on axial loading and tubercle tenderness) had an approximately 60% probability of fracture, and the authors suggest such patients may benefit from early advanced imaging when initial radiographs are nondiagnostic.

Watch out: The ~60% post-test figure is a modelled Bayesian estimate at an assumed 20% prevalence — it prints as modelled, with its prevalence, never as an observed rate.

Source: Huynh KA et al. Bayesian Statistics to Estimate Diagnostic Probability of Scaphoid Fractures from Clinical Examinations: A Meta-Analysis. Plastic and reconstructive surgery. 2021. PMID: 33620933. Registry ID: none in the record. MeSH: Bayes Theorem · Clinical Decision-Making/methods · Fractures, Bone/diagnosis,epidemiology,etiology · Humans · Musculoskeletal Pain/epidemiology,etiology · Physical Examination · Prevalence · Risk Assessment/methods · Risk Factors · Scaphoid Bone/injuries · Wrist Injuries/complications,diagnosis

Card 4 — Synthesis: 3 overlapping syntheses — counted as syntheses, never as independent cohorts — find scaphoid tests sensitive but poorly specific, combinations better than single tests, and no single feature able to exclude an occult fracture when the first radiograph is normal

Study: Synthesis

Population: All syntheses carded on this shelf: Mallee 2014 (13 articles), Coventry 2023 (8 studies, radiograph-negative slice) and Huynh 2021 (14 articles). Their primary-study sets overlap; the count is 3 syntheses.

Summary: Synthesis: 3 overlapping syntheses — counted as syntheses, never as independent cohorts — find scaphoid tests sensitive but poorly specific, combinations better than single tests, and no single feature able to exclude an occult fracture when the first radiograph is normal

Result: Figures from the all-comers and radiograph-negative slices never mix on this shelf, and no card implies a test-based discharge pathway is safe without imaging follow-up.

Watch out: See the individual cards for each synthesis's limits; this synthesis adds no new data.

Source: Synthesis of the reports carded above; no additional source.