SourceMed · Shelf #7865 in the ask interface

Hip examination tests: FADIR looks near-perfect in clinic spectra and fails as a screen in asymptomatic athletes (likelihood ratio below 1) — spectrum is the headline

Shelf #7865 · Bones & joints

PREDICTIVE PERFORMANCE — split by spectrum: FADIR pooled sensitivity 0.94–0.99 in clinic / surgical spectra (screening accuracy only, per its meta-analysis) against 41% / 47% with positive likelihood ratio 0.78 (labelled as such) in asymptomatic athletes, where it is inadequate for screening; a diagnostic-accuracy stamp, not a treatment stamp

Stamped: 2026-11-28.

Evidence published: 2015–2025.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In patients with hip or groin pain, how accurately do the hip examination tests — FADIR (flexion–adduction–internal rotation), FABER, flexion–internal rotation and the newer labral and microinstability tests — identify femoroacetabular impingement and acetabular labral tears against MRI, MR arthrography or arthroscopy: what pooled sensitivity do the meta-analyses give FADIR and flexion–internal rotation, how variable are the estimates in the 2025 review of prearthritic intra-articular pathology, and how badly does FADIR perform as a screening test in asymptomatic young athletes? (Base: 2 syntheses + 1 primary screening study in an asymptomatic spectrum.)

Balance of the evidence

The population split is the headline on this shelf: near-perfect sensitivity in surgical / clinic spectra against a positive likelihood ratio below 1 (0.78, labelled as such) in asymptomatic athletes — and no figure prints without its spectrum (symptomatic clinic vs asymptomatic screening). The meta-analysis's FADIR diagnostic odds ratios (labelled as such) carry intervals spanning an order of magnitude and print with them. The 2025 review reports best-in-study extremes, not pooled estimates, and they print only as such. Reference standards differ (MRI vs arthroscopy) and print. This is a diagnostic-accuracy shelf, not a treatment shelf.

MeSH: Femoracetabular Impingement/diagnosis · Humans · Lacerations/diagnosis · Physical Examination/methods,standards · ROC Curve · Reference Standards · Rupture/diagnosis

Cards (4)

Card 1 — Hip synthesis 1 of 2 — FAI / labral-tear meta-analysis (Reiman 2015; 21 articles identified, 9 meta-analysed, only one high quality): FADIR pooled sensitivity ranged 0.94–0.99 across its analyses with diagnostic odds ratios of 5.71–7.82, and flexion–internal rotation pooled sensitivity was 0.96 with a DOR of 8.36 — the authors conclude the tests possess only screening accuracy

Study: Systematic review with meta-analysis (synthesis 1 of 2; the primary screening study below is separate)

Population: Studies of clinical tests for hip femoroacetabular impingement / acetabular labral tear against MRI, MR arthrography or arthroscopy; 21 potential articles, 9 in the meta-analysis, only one demonstrating high quality on QUADAS-2. The review's registration is stated in its abstract as PROSPERO CRD42014010144. Synthesis 1 of 2 on this shelf, plus one primary screening study.

Summary: Hip synthesis 1 of 2 — FAI / labral-tear meta-analysis (Reiman 2015; 21 articles identified, 9 meta-analysed, only one high quality): FADIR pooled sensitivity ranged 0.94–0.99 across its analyses with diagnostic odds ratios of 5.71–7.82, and flexion–internal rotation pooled sensitivity was 0.96 with a DOR of 8.36 — the authors conclude the tests possess only screening accuracy

Result: Flexion-adduction-internal rotation (FADIR): pooled sensitivity ranging from 0.94 (95% CI 0.90 to 0.97) to 0.99 (0.98 to 1.00), with diagnostic odds ratios (labelled as such) of 5.71 (0.84 to 38.86) to 7.82 (1.06 to 57.84) across analyses. Flexion-internal rotation: pooled sensitivity 0.96 (0.81 to 0.99), DOR 8.36 (0.41 to 171.3). The authors conclude these tests possess only screening accuracy and that few tests have been investigated in enough substantial-quality studies to direct decision-making.

Watch out: The DOR intervals span an order of magnitude and only one included study was high quality — sensitivity near 1.0 in surgical spectra is not a rule-in.

Source: Reiman MP et al. Diagnostic accuracy of clinical tests for the diagnosis of hip femoroacetabular impingement/labral tear: a systematic review with meta-analysis. British journal of sports medicine. 2015. PMID: 25515771. Registry ID: none in the record. MeSH: Femoracetabular Impingement/diagnosis · Humans · Lacerations/diagnosis · Physical Examination/methods,standards · ROC Curve · Reference Standards · Rupture/diagnosis

Card 2 — Hip synthesis 2 of 2 — 2025 review of prearthritic intra-articular pathology (Dhillon 2025; 15 studies, 1,378 hips): estimates were highly variable — for labral tears FADIR showed the highest sensitivity (100%) and FABER the highest specificity (100%) among tests compared in individual studies, while for impingement FADIR specificity was only 47% in its best comparison — best-in-study extremes, not pooled estimates

Study: Systematic review (synthesis 2 of 2; no pooling — best-in-study extremes only)

Population: Patients with prearthritic intra-articular hip pathology (labral tear, femoroacetabular impingement or microinstability); 15 studies (4 Level I, 6 Level II, 5 Level III), 1,378 hips, mean ages 16.0–60.2 years, against MRI or direct visualisation at hip arthroscopy. The fetched record carries no MeSH terms — its source line reads 'MeSH: none in the record'. Synthesis 2 of 2 on this shelf.

Summary: Hip synthesis 2 of 2 — 2025 review of prearthritic intra-articular pathology (Dhillon 2025; 15 studies, 1,378 hips): estimates were highly variable — for labral tears FADIR showed the highest sensitivity (100%) and FABER the highest specificity (100%) among tests compared in individual studies, while for impingement FADIR specificity was only 47% in its best comparison — best-in-study extremes, not pooled estimates

Result: The abstract reports extremes from individual studies, not pooled estimates, and they are printed here only as such: for labral tears, FADIR had the highest sensitivity (100%) and FABER the highest specificity (100%) among the tests compared; for impingement, the internal-rotation-over-pressure test had the highest sensitivity (91%) and FADIR the highest specificity (47%); for microinstability, the abduction-hyperextension-external-rotation test had the highest sensitivity (80.6%) and the prone instability test the highest specificity (97.6%). The authors' conclusion is that sensitivity and specificity were highly variable.

Watch out: Never present a 100% figure from this review as a pooled or typical performance — each is the best result in one study's comparison, as the review reports it.

Source: Dhillon J et al. Sensitivity and Specificity for Physical Examination Tests in Diagnosing Prearthritic Intra-Articular Hip Pathology Are Highly Variable: A Systematic Review. Arthroscopy, sports medicine, and rehabilitation. 2025. PMID: 40692936. Registry ID: none in the record. MeSH: none in the record

Card 3 — Hip primary screening study — FADIR in asymptomatic young athletes (Casartelli 2018; 74 asymptomatic youth male ice-hockey players against MRI): for cam / pincer morphology with labral alteration, FADIR sensitivity was 41% and specificity 47% (positive likelihood ratio 0.78), and for cam morphology 60% / 52% — the authors conclude the test is inadequate for screening this population because of false positives

Study: Cross-sectional screening study (primary report; asymptomatic spectrum)

Population: 74 asymptomatic youth male ice-hockey players (mean age 16 years, range 13–20) without diagnosed hip disorders, assessed unilaterally with the FADIR test and MRI as the reference standard. The primary study on this shelf, in a screening spectrum entirely different from the clinic spectra of the syntheses.

Summary: Hip primary screening study — FADIR in asymptomatic young athletes (Casartelli 2018; 74 asymptomatic youth male ice-hockey players against MRI): for cam / pincer morphology with labral alteration, FADIR sensitivity was 41% and specificity 47% (positive likelihood ratio 0.78), and for cam morphology 60% / 52% — the authors conclude the test is inadequate for screening this population because of false positives

Result: For pure cam, pure pincer or combined morphology with acetabular labral alterations on MRI: FADIR sensitivity 41%, specificity 47%, positive likelihood ratio 0.78 and negative likelihood ratio 1.24 (labelled as such), positive predictive value 19% and negative predictive value 73%. For pure cam or combined morphology: sensitivity 60%, specificity 52%, positive likelihood ratio 1.24, negative likelihood ratio 0.78, PPV 16% and NPV 89%. The authors conclude the FADIR test is inadequate for screening cam and pincer morphology in this population because of the large number of false positives.

Watch out: A positive likelihood ratio below 1 (0.78) means a positive FADIR slightly lowered the odds in this screening setting — the opposite register from the clinic syntheses, and the reason spectrum prints with every figure on this shelf.

Source: Casartelli NC et al. The FADIR test accuracy for screening cam and pincer morphology in youth ice hockey players. Journal of science and medicine in sport. 2018. PMID: 28669665. Registry ID: none in the record. MeSH: Adolescent · Adult · Cross-Sectional Studies · Femoracetabular Impingement/diagnosis · Hip Joint/diagnostic imaging,physiopathology · Hockey/physiology · Humans · Magnetic Resonance Imaging · Male · Physical Examination · Predictive Value of Tests · Range of Motion, Articular · Self Report · Young Adult

Card 4 — Synthesis: 2 syntheses + 1 primary screening study split entirely by spectrum — FADIR sensitivity 0.94–0.99 in symptomatic / surgical spectra, highly variable best-in-study extremes in the 2025 review, and sensitivity 41% / specificity 47% (positive likelihood ratio 0.78) in asymptomatic young athletes, where the test is inadequate for screening

Study: Synthesis

Population: All reports carded on this shelf: Reiman 2015 (meta-analysis), Dhillon 2025 (systematic review, unpooled) and Casartelli 2018 (74 asymptomatic athletes). The count prints as 2 syntheses + 1 primary study, never as three independent clinic cohorts.

Summary: Synthesis: 2 syntheses + 1 primary screening study split entirely by spectrum — FADIR sensitivity 0.94–0.99 in symptomatic / surgical spectra, highly variable best-in-study extremes in the 2025 review, and sensitivity 41% / specificity 47% (positive likelihood ratio 0.78) in asymptomatic young athletes, where the test is inadequate for screening

Result: No figure prints without its spectrum and reference standard, and no card implies examination-guided pathways improve outcomes.

Watch out: See the individual cards for each report's limits; this synthesis adds no new data.

Source: Synthesis of the reports carded above; no additional source.