SourceMed · Shelf #7866 in the ask interface

Ottawa Knee Rule: sensitivity 1.0 in its originators' derivation, validation and implementation — pooled 0.98 / 0.43 externally, with a flagged discordance in the meta-analysis abstract

Shelf #7866 · Bones & joints

PREDICTIVE PERFORMANCE — high sensitivity, programme-derived: derivation / validation / implementation sensitivity 1.0 in the Stiell programme's own series, pooled 0.98 / 0.43 in the 18-study external meta-analysis (its abstract's HSROC 0.54 flagged as discordant with that pair, not printed as an estimate); implementation cut radiography by a relative 26.4% in its own trial; a prediction-accuracy stamp, not a treatment stamp

Stamped: 2026-11-28.

Evidence published: 1995–2023.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In adults with acute knee injury, how accurately does the Ottawa Knee Rule (radiography if any of: age ≥55, isolated patellar tenderness, fibular-head tenderness, inability to flex to 90°, inability to bear weight immediately and in the department) identify knee fractures — what sensitivity and specificity did the derivation and prospective validation find, what did implementation do to radiography use, waiting time and cost, and what pooled accuracy does the 2023 meta-analysis of 18 studies give? (Binding flag: that meta-analysis's abstract prints an HSROC area discordant with its own pooled pair — the pooled figures print and the discordance is flagged on the face.)

Balance of the evidence

All three primary reports are one programme's (the Stiell group's) and are labelled as such, with the 18-study meta-analysis as the external check. The derivation-to-meta-analysis sensitivity drift (1.0 in the originators' hands to a pooled 0.98) prints. BINDING on PMID 37215241: its abstract prints a hierarchical summary ROC area of 0.54, which is internally discordant with its own pooled sensitivity 0.98 / specificity 0.43 — this shelf prints the pooled figures and flags the discordance; the 0.54 figure is not printed as a performance estimate (per slate premise P7, it is either verified against the full text or omitted as an estimate). The implementation trial's radiography, time and cost effects are the rule's own trial results and print as such, but no card generalises them to other rules or settings. Paediatric performance is outside this shelf (the primaries are adult cohorts).

MeSH: Adult · Aged · Aged, 80 and over · Decision Support Techniques · Emergency Service, Hospital · Female · Fractures, Bone/diagnostic imaging · Guidelines as Topic · Humans · Knee Injuries/diagnostic imaging · Male · Middle Aged · Predictive Value of Tests · Prospective Studies · Radiography · Surveys and Questionnaires

Cards (5)

Card 1 — Ottawa derivation — Stiell programme report 1 of 3 (Stiell 1995; 1,047 adults with acute knee injury, 68 fractures): the derived rule was 100% sensitive (95% CI 0.95 to 1.0) with specificity 0.54, and its application would have reduced radiography by a relative 28.0% — programme-labelled: the Stiell group's own series

Study: Prospective derivation study (programme report 1 of 3 — the Stiell group's own series)

Population: Convenience sample of 1,047 adults with acute knee injury in two university-hospital emergency departments; 127 patients were double-examined for inter-observer agreement. Programme-labelled: the originators' own report, first of their three carded here.

Summary: Ottawa derivation — Stiell programme report 1 of 3 (Stiell 1995; 1,047 adults with acute knee injury, 68 fractures): the derived rule was 100% sensitive (95% CI 0.95 to 1.0) with specificity 0.54, and its application would have reduced radiography by a relative 28.0% — programme-labelled: the Stiell group's own series

Result: The rule (radiography if any of: age ≥55, isolated patellar tenderness, fibular-head tenderness, inability to flex to 90°, inability to bear weight immediately and in the department) identified the 68 fractures with sensitivity 1.0 (95% CI 0.95 to 1.0) and specificity 0.54. Application would have led to a relative 28.0% reduction in radiography use (from 68.6% to 49.4% in the study population). The authors state clinical application should await prospective validation.

Watch out: Derivation performance in the originators' hands is the ceiling, not the expectation — the pooled external figure is on the meta-analysis card.

Source: Stiell IG et al. Derivation of a decision rule for the use of radiography in acute knee injuries. Annals of emergency medicine. 1995. PMID: 7574120. Registry ID: none in the record. MeSH: Adult · Aged · Aged, 80 and over · Decision Support Techniques · Emergency Service, Hospital · Female · Fractures, Bone/diagnostic imaging · Guidelines as Topic · Humans · Knee Injuries/diagnostic imaging · Male · Middle Aged · Predictive Value of Tests · Prospective Studies · Radiography · Surveys and Questionnaires

Card 2 — Ottawa prospective validation — Stiell programme report 2 of 3 (Stiell 1996; 1,096 adults, 63 clinically important fractures): sensitivity was again 1.0 (95% CI 0.94 to 1.0), physicians interpreted the rule correctly in 96% of cases (κ 0.77), the estimated fracture probability after a negative rule was 0% (0% to 0.4%), and refinement attempts cost unacceptable sensitivity — programme-labelled: the Stiell group's own series

Study: Prospective validation study (programme report 2 of 3 — the Stiell group's own series)

Population: Convenience sample of 1,096 of 1,251 eligible adults with acute knee injuries in two university-hospital emergency departments; 124 patients were examined by two physicians. Programme-labelled: the originators' own report, second of their three carded here.

Summary: Ottawa prospective validation — Stiell programme report 2 of 3 (Stiell 1996; 1,096 adults, 63 clinically important fractures): sensitivity was again 1.0 (95% CI 0.94 to 1.0), physicians interpreted the rule correctly in 96% of cases (κ 0.77), the estimated fracture probability after a negative rule was 0% (0% to 0.4%), and refinement attempts cost unacceptable sensitivity — programme-labelled: the Stiell group's own series

Result: The decision rule had sensitivity 1.0 (95% CI 0.94 to 1.0) for identifying 63 clinically important fractures, with a potential relative reduction in radiography estimated at 28%. Physicians correctly interpreted the rule in 96% of cases (κ 0.77 for interpretation, 0.65 to 0.89). The probability of fracture if the rule were negative was estimated at 0% (0% to 0.4%). Attempts to refine the rule improved specificity only with an unacceptable loss of sensitivity.

Watch out: Still the originators' own programme and setting — independent transportability comes only from the meta-analysis card.

Source: Stiell IG et al. Prospective validation of a decision rule for the use of radiography in acute knee injuries. JAMA. 1996. PMID: 8594242. Registry ID: none in the record. MeSH: Adult · Aged · Aged, 80 and over · Decision Support Techniques · Emergency Service, Hospital/standards,statistics & numerical data · Female · Fractures, Bone/diagnostic imaging · Hospitals, University · Humans · Knee Injuries/diagnostic imaging · Male · Middle Aged · Ontario · Probability · Prospective Studies · Radiography/statistics & numerical data · Reproducibility of Results · Sensitivity and Specificity

Card 3 — Ottawa implementation trial — Stiell programme report 3 of 3 (Stiell 1997; controlled before–after trial, 3,907 patients in 4 hospitals): radiography referral fell by a relative 26.4% in intervention hospitals vs 1.3% in controls, the rule remained 100% sensitive for 58 fractures (κ 0.91), and patients discharged without radiography spent less time in the department (85.7 vs 118.8 minutes) at lower estimated charges ($80 vs $183) — programme-labelled: the Stiell group's own series

Study: Controlled before–after implementation trial (programme report 3 of 3 — the Stiell group's own series)

Population: All 3,907 consecutive eligible adults with acute knee injuries in 2 teaching and 2 community hospitals, over 12-month periods before and after implementation. Programme-labelled: the originators' own report, third of their three carded here.

Summary: Ottawa implementation trial — Stiell programme report 3 of 3 (Stiell 1997; controlled before–after trial, 3,907 patients in 4 hospitals): radiography referral fell by a relative 26.4% in intervention hospitals vs 1.3% in controls, the rule remained 100% sensitive for 58 fractures (κ 0.91), and patients discharged without radiography spent less time in the department (85.7 vs 118.8 minutes) at lower estimated charges ($80 vs $183) — programme-labelled: the Stiell group's own series

Result: There was a relative reduction of 26.4% in the proportion referred for knee radiography in the intervention group (77.6% vs 57.1%; P<.001) vs a relative 1.3% in controls (76.9% vs 75.9%; P=.60). The rule had sensitivity 1.0 (95% CI 0.94 to 1.0) for 58 knee fractures, with κ 0.91 for interpretation. Compared with non-fracture patients who underwent radiography in the after period, those discharged without radiography spent less time in the department (85.7 vs 118.8 minutes) and incurred lower estimated total charges (US $80 vs $183). No missed fractures or patient dissatisfaction were found.

Watch out: The time and charge figures are this trial's own 1997 results in its hospitals — do not generalise them to other rules, settings or eras.

Source: Stiell IG et al. Implementation of the Ottawa Knee Rule for the use of radiography in acute knee injuries. JAMA. 1997. PMID: 9403421. Registry ID: none in the record. MeSH: Acute Disease · Adult · Aged · Decision Support Systems, Clinical · Emergency Service, Hospital/economics,standards · Female · Fractures, Bone/diagnostic imaging · Guidelines as Topic · Humans · Knee Injuries/diagnostic imaging · Male · Middle Aged · Ontario · Radiography/economics,standards,statistics & numerical data

Card 4 — Ottawa meta-analysis — external check (Kazemi 2023; 18 studies, 6,702 patients): pooled sensitivity was 0.98 (95% CI 0.96 to 0.99) and pooled specificity 0.43 (0.42 to 0.45), with positive and negative likelihood ratios of 1.56 and 0.12 — and a flagged internal discordance: the same abstract prints a hierarchical summary ROC area of 0.54, which cannot describe the same analysis as its pooled pair

Study: Systematic review and meta-analysis (external check; abstract internally discordant — see result)

Population: Studies of the Ottawa Knee Rule for fracture in patients presenting with knee trauma, searched to September 2022; 18 studies, 6,702 patients, quality assessed with QUADAS-2. The fetched record carries no MeSH terms — its source line reads 'MeSH: none in the record'. The external check on the Stiell programme reports.

Summary: Ottawa meta-analysis — external check (Kazemi 2023; 18 studies, 6,702 patients): pooled sensitivity was 0.98 (95% CI 0.96 to 0.99) and pooled specificity 0.43 (0.42 to 0.45), with positive and negative likelihood ratios of 1.56 and 0.12 — and a flagged internal discordance: the same abstract prints a hierarchical summary ROC area of 0.54, which cannot describe the same analysis as its pooled pair

Result: Pooled sensitivity 0.98 (95% CI 0.96 to 0.99) and pooled specificity 0.43 (0.42 to 0.45); pooled positive likelihood ratio 1.56 (1.39 to 1.75) and negative likelihood ratio 0.12 (0.05 to 0.26) — likelihood ratios labelled as such. DISCORDANCE FLAG (binding): the abstract also prints a hierarchical summary ROC area of 0.54, which is internally discordant with its own pooled sensitivity / specificity above; this shelf prints the pooled figures and flags the discordance, and does not print the 0.54 as a performance estimate — per the slate's premise P7 it is either verified against the full text or omitted as an estimate.

Watch out: Do not quote an AUC of 0.54 for the Ottawa Knee Rule from this abstract beside a pooled sensitivity of 0.98 — the two cannot both describe the same analysis, and the discordance is flagged, not resolved, on this shelf.

Source: Kazemi SM et al. Diagnostic Accuracy of Ottawa Knee Rule for Diagnosis of Fracture in Patients with Knee Trauma; a Systematic Review and Meta-analysis. Archives of academic emergency medicine. 2023. PMID: 37215241. Registry ID: none in the record. MeSH: none in the record

Card 5 — Synthesis: the Stiell programme's derivation, validation and implementation reports (all labelled as one programme's) found sensitivity 1.0 throughout, and the external 18-study meta-analysis pools at 0.98 / 0.43 — a small sensitivity drift from the originators' hands — while its own abstract's HSROC area is discordant with that pooled pair and is flagged, not printed as an estimate

Study: Synthesis

Population: All reports carded on this shelf: Stiell 1995 (1,047 adults), Stiell 1996 (1,096) and Stiell 1997 (3,907), one programme's series, plus Kazemi 2023 (18 studies, 6,702 patients) as the external check.

Summary: Synthesis: the Stiell programme's derivation, validation and implementation reports (all labelled as one programme's) found sensitivity 1.0 throughout, and the external 18-study meta-analysis pools at 0.98 / 0.43 — a small sensitivity drift from the originators' hands — while its own abstract's HSROC area is discordant with that pooled pair and is flagged, not printed as an estimate

Result: Implementation effects print only as that trial's own results, paediatric performance is outside this shelf, and no card generalises the rule's savings to other decision rules.

Watch out: See the individual cards for each report's limits, including the binding discordance flag on the meta-analysis card; this synthesis adds no new data.

Source: Synthesis of the reports carded above; no additional source.