SourceMed · Shelf #7874 in the ask interface

Carotid bruit for carotid stenosis (FLOOR-RISK — exactly 2 reports): specific but insensitive (56%/98% community; 71%/81% referral), sensitivity 26% in occlusion — a silent neck excludes nothing; 1993 synthesis refused as anchor (no abstract)

Shelf #7874 · Heart, vessels, blood pressure & clotting

PREDICTIVE PERFORMANCE — FLOOR-RISK, exactly 2 abstract-verifiable reports: bruit sensitivity 56% / specificity 98% in a community cohort (2.2% prevalence) and 71% / 81% at 50–99% stenosis in a referral series, collapsing to 26% in occlusion; the 1993 synthesis (PMID 8133624) has no PubMed abstract and is refused as an anchor on the Synthesis card; a diagnostic-accuracy stamp, not a treatment stamp

Stamped: 2026-11-28.

Evidence published: 2008–2009.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

At the bedside, how accurately does a carotid bruit heard on neck auscultation identify haemodynamically significant carotid stenosis against duplex ultrasonography — what sensitivity, specificity and predictive values did the Northern Manhattan community cohort find for stenosis ≥60%, how did auscultation perform in the Swedish ultrasound-referral series at the 50–99% and occlusion bands, and what should a negative examination be taken to exclude? (FLOOR-RISK — rests on exactly 2 abstract-verifiable reports; the field's 1993 synthesis, PMID 8133624, has no PubMed abstract, cannot anchor, and is refused on the Synthesis card.)

Balance of the evidence

FLOOR-RISK — this shelf rests on exactly 2 abstract-verifiable reports, and that exact basis prints here and on every card: a stroke-free community cohort (686 subjects, ≥60% stenosis prevalence 2.2%; sensitivity 56%, specificity 98%, PPV 25%, NPV 99%) and a Swedish ultrasound-referral series (sensitivity 71%, specificity 81% at 50–99% stenosis). The literature's synthesising source — the 1993 Rational Clinical Examination review, PMID 8133624 — exists but has no abstract in PubMed and cannot be carded under the verification rule; the refusal is recorded on the Synthesis card and the row does not rely on it. The two anchors answer from opposite sampling frames and their predictive values never mix. The occlusion paradox prints: a totally occluded artery is often silent (sensitivity 26%). This is a diagnostic-accuracy shelf — no card may imply bruit-guided referral pathways improve stroke outcomes.

MeSH: Adult · Aged · Aged, 80 and over · Auscultation/methods · Carotid Arteries/diagnostic imaging/physiopathology · Carotid Stenosis/diagnosis/epidemiology/physiopathology · Echocardiography/methods · Female · Hemodynamics/physiology · Humans · Male · Middle Aged · New York City/epidemiology · Prevalence · Radiography · Ultrasonography, Doppler, Duplex/methods · Adolescent · Angiography/economics · Carotid Stenosis/complications/diagnostic imaging/surgery · Child · Child, Preschool · Cost-Benefit Analysis · Endarterectomy, Carotid · Likelihood Functions · Mass Screening/economics/methods/standards · Sensitivity and Specificity · Stroke/etiology/prevention & control · Ultrasonography/economics/standards

Cards (4)

Card 1 — FLOOR-RISK report 1 of exactly 2 — Northern Manhattan community cohort (Ratchford 2009, Neurological Research — 686 stroke-free community subjects, ≥60% stenosis prevalence 2.2%): auscultation had sensitivity 56%, specificity 98%, PPV 25%, NPV 99% for ipsilateral ≥60% stenosis — a 44% false-negative rate, so auscultation cannot exclude stenosis

Study: Community-cohort accuracy study — Northern Manhattan Study (FLOOR-RISK report 1 of exactly 2)

Population: 686 stroke-free subjects from the Northern Manhattan Study community cohort (of 3,298 in the stroke-free cohort; mean age 68.2 ± 9.4 years) who were examined for carotid bruits and underwent carotid duplex, the reference standard. Bruit prevalence was 4.1% and ≥60% stenosis prevalence 2.2% — an unselected community sampling frame, which prints with every predictive value.

Summary: FLOOR-RISK report 1 of exactly 2 — Northern Manhattan community cohort (Ratchford 2009, Neurological Research — 686 stroke-free community subjects, ≥60% stenosis prevalence 2.2%): auscultation had sensitivity 56%, specificity 98%, PPV 25%, NPV 99% for ipsilateral ≥60% stenosis — a 44% false-negative rate, so auscultation cannot exclude stenosis

Result: For detection of ≥60% carotid stenosis, sensitivity of auscultation was 56%, specificity 98%, positive predictive value 25%, negative predictive value 99% and overall accuracy 97.5%, as published. The authors conclude the 44% false-negative rate means auscultation is not sufficient to exclude carotid stenosis, while a bruit may still warrant duplex evaluation.

Watch out: FLOOR-RISK basis, printed exactly: this shelf rests on exactly 2 abstract-verifiable reports — this community cohort and the Swedish referral series (card 2). The field's synthesising source (PMID 8133624, 1993) exists but has no abstract in PubMed and cannot anchor; it is refused on the Synthesis card, not carded. PPV 25% and NPV 99% belong to this 2.2%-prevalence frame and never mix with the referral series.

Source: Ratchford EV et al. Carotid bruit for detection of hemodynamically significant carotid stenosis: the Northern Manhattan Study. Neurological research. 2009. PMID: 19133168. Registry ID: none in the record. MeSH: Adult · Aged · Aged, 80 and over · Auscultation/methods · Carotid Arteries/diagnostic imaging/physiopathology · Carotid Stenosis/diagnosis/epidemiology/physiopathology · Echocardiography/methods · Female · Hemodynamics/physiology · Humans · Male · Middle Aged · New York City/epidemiology · Prevalence · Radiography · Ultrasonography, Doppler, Duplex/methods

Card 2 — FLOOR-RISK report 2 of exactly 2 — Swedish ultrasound-referral series (Johansson 2008, BMC Neurology — 1,555 consecutive carotid ultrasound investigations; 291 of 356 patients with ≥50% stenosis examined for bruits): in 50–99% stenosis, bruits had sensitivity 71%, specificity 81%, accuracy 75%, positive likelihood ratio 3.65 and negative 0.36 (labelled as such) — but sensitivity collapsed to 26% in complete occlusion

Study: Observational ultrasound-referral series (FLOOR-RISK report 2 of exactly 2)

Population: 1,555 consecutive carotid ultrasonography investigations (1,486 cases) at a Swedish university hospital, 2004–2006; 356 subjects had significant (≥50%) ultrasound-verified stenosis, of whom 291 had been examined for bruits. A referral sampling frame — the opposite pole from card 1's community cohort — and its predictive values never mix with card 1's.

Summary: FLOOR-RISK report 2 of exactly 2 — Swedish ultrasound-referral series (Johansson 2008, BMC Neurology — 1,555 consecutive carotid ultrasound investigations; 291 of 356 patients with ≥50% stenosis examined for bruits): in 50–99% stenosis, bruits had sensitivity 71%, specificity 81%, accuracy 75%, positive likelihood ratio 3.65 and negative 0.36 (labelled as such) — but sensitivity collapsed to 26% in complete occlusion

Result: In patients with 50–99% carotid stenoses, carotid bruits had accuracy 75% (436/582), sensitivity 71% (236/334), specificity 81% (200/248), a positive likelihood ratio of 3.65 and a negative likelihood ratio of 0.36 (labelled as such). Sensitivity was highest at 77% (183/238) for 70–99% stenoses, but in 100% stenoses (complete occlusion) sensitivity was only 26% (15/57) with specificity 49% — the occlusion paradox: a totally occluded artery is often silent. 31% of persons referred with bruit as the indication had a significant stenosis, as published.

Watch out: FLOOR-RISK basis, printed exactly: exactly 2 abstract-verifiable reports carry this shelf. The occlusion figure (sensitivity 26%) prints beside any sensitivity headline — the most severe lesion is the one auscultation most often misses. Likelihood ratios are labelled as such wherever printed.

Source: Johansson EP et al. Carotid bruits as predictor for carotid stenoses detected by ultrasonography: an observational study. BMC neurology. 2008. PMID: 18577216. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Aged, 80 and over · Angiography/economics · Carotid Stenosis/complications/diagnostic imaging/surgery · Child · Child, Preschool · Cost-Benefit Analysis · Endarterectomy, Carotid · Female · Humans · Likelihood Functions · Male · Mass Screening/economics/methods/standards · Middle Aged · Sensitivity and Specificity · Stroke/etiology/prevention & control · Ultrasonography/economics/standards

Card 3 — Cross-report summary of the two carded reports — not an additional report (source line repeats the Northern Manhattan cohort for reference): the two sampling frames answer from opposite poles — 56% sensitivity at 2.2% prevalence in the community against 71% at 50–99% in a referral series — and a negative examination excludes stenosis in neither

Study: Cross-report summary of the two carded reports — not an additional report (FLOOR-RISK)

Population: The two reports carded above only: Ratchford 2009 (686 community subjects) and Johansson 2008 (1,555 consecutive ultrasound investigations). No third abstract-verifiable report was carried through verification for this row — that is the FLOOR-RISK basis, stated here so the count can never be misread.

Summary: Cross-report summary of the two carded reports — not an additional report (source line repeats the Northern Manhattan cohort for reference): the two sampling frames answer from opposite poles — 56% sensitivity at 2.2% prevalence in the community against 71% at 50–99% in a referral series — and a negative examination excludes stenosis in neither

Result: Read together: specificity is high in the community frame (98%) and moderate in the referral frame (81%); sensitivity is mediocre in both (56% and 71%) and collapses in complete occlusion (26%). The shared conclusion of both reports is negative — absence of a bruit does not exclude significant stenosis — and neither report supports bruit-guided referral as an outcome-improving pathway, which neither tested.

Watch out: This card adds no evidence; it exists so the 2-report basis and the two-frame structure are unmissable on the face of the shelf.

Source: Ratchford EV et al. Carotid bruit for detection of hemodynamically significant carotid stenosis: the Northern Manhattan Study. Neurological research. 2009. PMID: 19133168. Registry ID: none in the record. MeSH: Adult · Aged · Aged, 80 and over · Auscultation/methods · Carotid Arteries/diagnostic imaging/physiopathology · Carotid Stenosis/diagnosis/epidemiology/physiopathology · Echocardiography/methods · Female · Hemodynamics/physiology · Humans · Male · Middle Aged · New York City/epidemiology · Prevalence · Radiography · Ultrasonography, Doppler, Duplex/methods

Card 4 — Synthesis: FLOOR-RISK — this shelf rests on exactly 2 abstract-verifiable reports, and that exact basis prints here and on every card. REFUSAL recorded on this card: the literature's synthesising source, the 1993 Rational Clinical Examination review of the carotid bruit (PMID 8133624), exists in PubMed but has NO abstract there and therefore cannot anchor a card under this desk's verification rule — it is NOT carded, NOT relied on, and no figure on this shelf derives from it; the row was built only because the 2 abstract-verifiable reports above carry it as FLOOR-RISK. Within that base: a bruit is specific but insensitive (56%/98% in the community at 2.2% prevalence; 71%/81% at 50–99% in referrals), and a silent neck excludes nothing — least of all occlusion (sensitivity 26%)

Study: Synthesis

Population: All reports carded on this shelf: Ratchford 2009 (Northern Manhattan, N = 686) and Johansson 2008 (1,555 investigations). PMID 8133624 is named here only to record its refusal as an anchor (existing-but-unanchorable: no PubMed abstract); it contributes no data to this shelf.

Summary: Synthesis: FLOOR-RISK — this shelf rests on exactly 2 abstract-verifiable reports, and that exact basis prints here and on every card. REFUSAL recorded on this card: the literature's synthesising source, the 1993 Rational Clinical Examination review of the carotid bruit (PMID 8133624), exists in PubMed but has NO abstract there and therefore cannot anchor a card under this desk's verification rule — it is NOT carded, NOT relied on, and no figure on this shelf derives from it; the row was built only because the 2 abstract-verifiable reports above carry it as FLOOR-RISK. Within that base: a bruit is specific but insensitive (56%/98% in the community at 2.2% prevalence; 71%/81% at 50–99% in referrals), and a silent neck excludes nothing — least of all occlusion (sensitivity 26%)

Result: This is a diagnostic-accuracy shelf, not a treatment shelf: no card implies bruit-guided referral pathways improve stroke outcomes. Failed verification of this exact 2-report basis would have stopped the build; the basis verified as stated, so the shelf is built as FLOOR-RISK with the basis and the refusal on its face.

Watch out: See the individual cards for each report's limits; this synthesis adds no new data.

Source: Synthesis of the reports carded above; no additional source.