SourceMed · Shelf #7912 in the ask interface

Geriatric Depression Scale accuracy in older adults: 3 overlapping syntheses, counted as syntheses — GDS-15 pools sensitivity 86% / specificity 79% overall, but in primary care both forms rate 'poor' for case-finding

Shelf #7912 · Geriatrics, frailty & deprescribing

PREDICTIVE PERFORMANCE — form- and setting-dependent: base is exactly 3 syntheses whose primary-study sets overlap, counted as syntheses only — GDS-15 pools at sensitivity 86% / specificity 79% (53-study meta-analysis) and 0.89 / 0.77 at a cut-off of 5 (brief-forms meta-analysis), but in primary care specifically GDS-30 falls to 77.4% / 65.4% and both forms rate 'poor' for case-finding; no figure prints without its form and cut-off; a screening-accuracy stamp, not a treatment stamp

Stamped: 2026-11-28.

Evidence published: 2010–2020.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In older adults, how accurately do the forms of the Geriatric Depression Scale (GDS-30, GDS-15, GDS-10, GDS-4 — yes / no items, the 15-item form conventionally positive at ≥5) detect depression against diagnostic interviews — what pooled sensitivity and specificity does the 53-study meta-analysis give each form, what does the brief-forms meta-analysis give the GDS-15 at its recommended cut-off, and how much worse does the GDS-30 perform than the GDS-15 in primary care specifically, including each form's rated clinical utility for case-finding vs screening?

Balance of the evidence

A screening-accuracy shelf, not a treatment shelf. This row rests on exactly 3 syntheses whose primary-study sets overlap; the count prints as 3 syntheses, never as independent cohorts. The forms are different instruments (30 / 15 / 10 / 4 items) and no figure prints without its form and cut-off. The primary-care analysis is the transportability evidence: there the GDS-30 falls to 77.4% / 65.4% (specificity interval 44.2% to 83.8%) and adds nothing over unassisted GP diagnosis, while the GDS-15 (81.3% / 78.4%) is rated 'good' for screening though both forms are 'poor' for case-finding. Performance in dementia specifically is materially worse (GDS-30 sensitivity 0.62 in the synthesis carded on shelf #7920) and the two shelves cross-point.

MeSH: Aged · Aged, 80 and over · Depression/diagnosis · Geriatric Assessment · Humans · Psychiatric Status Rating Scales · Sensitivity and Specificity · Female · Geriatric Assessment/methods · Male · Depressive Disorder/diagnosis/psychology · Major Depressive Disorder/diagnosis/psychology · Interview, Psychological · Mass Screening · Personality Assessment/statistics & numerical data · Personality Inventory/statistics & numerical data · Primary Health Care · Psychometrics/statistics & numerical data · Reproducibility of Results

Cards (4)

Card 1 — 53-study meta-analysis (17,018 participants): GDS-30 82% / 76% (AUC 0.85), GDS-15 86% / 79% (AUC 0.90), GDS-10 87% / 75% (AUC 0.83), GDS-4 74% / 71% — all four forms in the neither-confirm-nor-exclude quadrant of the likelihood-ratio scattergram

Study: Systematic review and meta-analysis (synthesis 1 of 3 on this shelf; 53 studies, 17,018 participants)

Population: 53 studies with 17,018 older participants, each form of the Geriatric Depression Scale (30, 15, 10 and 4 yes/no items) assessed against diagnostic standards by bivariate meta-analysis.

Summary: 53-study meta-analysis (17,018 participants): GDS-30 82% / 76% (AUC 0.85), GDS-15 86% / 79% (AUC 0.90), GDS-10 87% / 75% (AUC 0.83), GDS-4 74% / 71% — all four forms in the neither-confirm-nor-exclude quadrant of the likelihood-ratio scattergram

Result: Pooled sensitivity / specificity were 82% / 76% for the GDS-30 (AUC 0.85), 86% / 79% for the GDS-15 (AUC 0.90), 87% / 75% for the GDS-10 (AUC 0.83) and 74% / 71% for the GDS-4. Diagnostic performance was better for the shorter forms (GDS-15, GDS-10) than for the GDS-30, and all four forms belonged to the right-lower quadrant of the likelihood-ratio scattergram, indicating neither confirmation nor exclusion, as published.

Watch out: The four forms are different instruments (30 / 15 / 10 / 4 items) — a pooled pair for one form never describes another, and no figure prints without its form; this synthesis's primary-study set overlaps those of the other two syntheses on this shelf.

Source: Krishnamoorthy Y et al. Diagnostic accuracy of various forms of geriatric depression scale for screening of depression among older adults: Systematic review and meta-analysis. Archives of gerontology and geriatrics. 2020. PMID: 31881393. Registry ID: none in the record. MeSH: Aged · Aged, 80 and over · Depression/diagnosis · Geriatric Assessment · Humans · Psychiatric Status Rating Scales · Sensitivity and Specificity

Card 2 — Brief-forms meta-analysis (32 studies of seven brief forms): the GDS-15 at the recommended cut-off of 5 pooled at sensitivity 0.89 / specificity 0.77 — with the authors' warning of possible selective cut-off reporting

Study: Systematic review and meta-analysis of brief versions (synthesis 2 of 3 on this shelf; 32 studies)

Population: 32 studies providing diagnostic data on seven brief versions of the Geriatric Depression Scale (1, 4, 5, 7, 8, 10 and 15 items) in older adults, each against a recognised gold-standard diagnostic instrument.

Summary: Brief-forms meta-analysis (32 studies of seven brief forms): the GDS-15 at the recommended cut-off of 5 pooled at sensitivity 0.89 / specificity 0.77 — with the authors' warning of possible selective cut-off reporting

Result: Only the GDS-15 could be meta-analysed: at the recommended cut-off score of 5, pooled sensitivity was 0.89 (95% CI 0.80 to 0.94) and specificity 0.77 (0.65 to 0.86). Meta-analysis of the other brief versions was not possible because of an insufficient number of studies with standardised items. The authors caution that selective reporting of cut-off scores is possible and findings should be approached cautiously, as published.

Watch out: Selective cut-off reporting may inflate this pair — the source says so and it prints; the 0.89 / 0.77 pair belongs to the GDS-15 at a cut-off of 5 only.

Source: Pocklington C et al. The diagnostic accuracy of brief versions of the Geriatric Depression Scale: a systematic review and meta-analysis. International journal of geriatric psychiatry. 2016. PMID: 26890937. Registry ID: none in the record. MeSH: Aged · Aged, 80 and over · Depression/diagnosis · Female · Geriatric Assessment/methods · Humans · Male · Psychiatric Status Rating Scales

Card 3 — Primary-care meta-analysis (17 analyses): GDS-30 sensitivity 77.4% / specificity 65.4% vs GDS-15 81.3% / 78.4% — clinical utility rated 'poor' for case-finding for both forms but 'good' for screening for the GDS-15; at 15% prevalence the GDS-15 added 4 cases found and 4 non-cases ruled out per 100 attendees over unassisted GP diagnosis, while the GDS-30 added nothing

Study: Primary-care meta-analysis (synthesis 3 of 3 on this shelf; 17 analyses in 14 publications)

Population: 17 primary-care analyses (7 of the GDS-30, 10 of the GDS-15) drawn from 69 studies measuring the GDS against a semistructured psychiatric interview; clinical utility and added value over unassisted GP diagnosis were also assessed.

Summary: Primary-care meta-analysis (17 analyses): GDS-30 sensitivity 77.4% / specificity 65.4% vs GDS-15 81.3% / 78.4% — clinical utility rated 'poor' for case-finding for both forms but 'good' for screening for the GDS-15; at 15% prevalence the GDS-15 added 4 cases found and 4 non-cases ruled out per 100 attendees over unassisted GP diagnosis, while the GDS-30 added nothing

Result: GDS-30 sensitivity was 77.4% (95% CI 66.3% to 86.8%) and specificity 65.4% (44.2% to 83.8%); GDS-15 sensitivity was 81.3% (77.2% to 85.2%) and specificity 78.4% (71.2% to 84.8%), with a significantly higher correctly-identified fraction (77.6% vs 71.2%). Clinical utility was 'poor' for case-finding for both forms; for screening the GDS-15 was rated 'good' and the GDS-30 'adequate'. At 15% prevalence the GDS-15 identified an additional 4 cases and ruled out an additional 4 non-cases per 100 attendees over unassisted GP diagnosis (an estimated 8% gain, at 3–4 extra minutes per appointment), while the GDS-30 had no added benefit. The authors recommend the GDS-15, not the GDS-30, in primary care, as published.

Watch out: This is the transportability evidence for this shelf: the GDS-30's primary-care specificity interval runs from 44.2% to 83.8% and prints with the point estimate; the pooled pairs on cards 1–2 must not be quoted as primary-care performance.

Source: Mitchell AJ et al. Diagnostic validity and added value of the Geriatric Depression Scale for depression in primary care: a meta-analysis of GDS30 and GDS15. Journal of affective disorders. 2010. PMID: 19800132. Registry ID: none in the record. MeSH: Aged · Depressive Disorder/diagnosis/psychology · Major Depressive Disorder/diagnosis/psychology · Humans · Interview, Psychological · Mass Screening · Personality Assessment/statistics & numerical data · Personality Inventory/statistics & numerical data · Primary Health Care · Psychometrics/statistics & numerical data · Reproducibility of Results

Card 4 — Synthesis: across 3 overlapping syntheses the shorter forms beat the GDS-30 — but in primary care both forms are 'poor' for case-finding, the GDS-15 alone earns a 'good' screening rating and an 8% added-value gain, and in dementia specifically performance falls further (GDS-30 sensitivity 0.62 in the synthesis carded on shelf #7920)

Study: Synthesis

Population: All reports carded above — exactly 3 syntheses whose primary-study sets overlap, counted as syntheses, never as independent cohorts: Krishnamoorthy 2020 (53 studies), Pocklington 2016 (32 studies) and Mitchell 2010 (17 primary-care analyses). Cross-points: the PHQ-9 shelf (#7870) and the EPDS shelf cover different instruments and populations; the Cornell shelf (#7920) covers depression case-finding in dementia — the synthesis carded there carries a GDS-30 limb in dementia (sensitivity 0.62 / specificity 0.81), a comparator limb shared with this shelf and stated openly on both.

Summary: Synthesis: across 3 overlapping syntheses the shorter forms beat the GDS-30 — but in primary care both forms are 'poor' for case-finding, the GDS-15 alone earns a 'good' screening rating and an 8% added-value gain, and in dementia specifically performance falls further (GDS-30 sensitivity 0.62 in the synthesis carded on shelf #7920)

Result: A screening-accuracy shelf, not a treatment shelf. Form and cut-off print with every figure: the GDS-15 at ≥5 is the best-supported configuration on this evidence, and the primary-care meta-analysis itself recommends the GDS-15 over the GDS-30.

Watch out: See the individual cards for each report's limits; this synthesis adds no new data.

Source: Synthesis of the reports carded above; no additional source.