SourceMed · Shelf #7915 in the ask interface
Bedside detection of splenomegaly: examiner dependence is the headline — one manoeuvre's sensitivity ranged 0% to 64.3% across eight examiners; concordant palpation plus percussion reaches 97% specificity at 46% sensitivity
Shelf #7915 · Heart, vessels, blood pressure & clotting
PREDICTIVE PERFORMANCE — examiner- and habitus-dependent: no pooled sensitivity is printed without the examiner range (palpation sensitivity 0%–64.3% across examiners in the multiple-observer study); lean vs obese discrimination AUC 0.83 vs 0.65; two anchors' cohort sizes are not documented in their abstracts and print as 'N not documented'; a diagnostic-accuracy stamp, not a treatment stamp
Stamped: 2026-11-28.
Evidence published: 1991–2018.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
At the bedside, how accurately do palpation and percussion manoeuvres — supine and lateral-decubitus palpation, Middleton's manoeuvre, Traube's-space percussion, Castell's method and Nixon's method — detect splenomegaly against ultrasonography: what sensitivity and specificity did each manoeuvre achieve in the prospective bedside-assessment study, how wide was the examiner-to-examiner variation when eight examiners each applied three palpation and three percussion methods to the same patients, which manoeuvres performed best in the 80-patient accuracy study and in the 100-case Traube's-space study, and do sonographic versions of the same manoeuvres beat the hands-on originals?
Balance of the evidence
A diagnostic-accuracy shelf, not a treatment shelf. Examiner dependence is the headline: in the multiple-observer study the same manoeuvre's sensitivity ranged from 0% to 64.3% across examiners, and no pooled sensitivity is printed without that range. Body habitus moves the results (lean vs obese AUC 0.83 vs 0.65; Traube's false negatives at higher BMI) and prints. Reference standards differ slightly (ultrasonographic enlargement vs ≥13 cm length) and print. Two anchors' cohort sizes are not stated in their abstracts and print on the face as 'N not documented'. The sonographic-version study is carded as the comparison limb, not as a further palpation estimate. The 1993 Rational Clinical Examination synthesis (PMID 8411607) exists but has no abstract in PubMed and is not carded.
MeSH: Adult · Aged · Female · Humans · Male · Middle Aged · Palpation/methods · Percussion/methods · Physical Examination/methods · ROC Curve · Splenomegaly/diagnosis/diagnostic imaging · Ultrasonography · Double-Blind Method · HIV Infections/complications · Observer Variation · Palpation · Percussion · Physical Examination · Prospective Studies · Reproducibility of Results · Sensitivity and Specificity · Spleen/diagnostic imaging · Splenomegaly/complications/diagnosis/diagnostic imaging · Adolescent · Splenomegaly/diagnosis · Ambulatory Care Facilities · Ultrasonography/methods
Cards (6)
Card 1 — Prospective bedside study (Barkun 1991, vs ultrasonography; N not documented): Traube's-space percussion AUC 0.70 and palpation AUC 0.76; splenic percussion sign 79% / 46% vs Traube's percussion 62% / 72%; a concordant-positive examination (palpation plus percussion) gave 46% sensitivity / 97% specificity
Study: Prospective bedside-assessment study vs ultrasonography (report 1 of 5; N not documented in the abstract)
Population: Inpatients of a tertiary-care hospital, selected as cases and controls according to abdominal ultrasonographic examination results, assessed with Traube's-space percussion, the splenic percussion sign, Middleton's manoeuvre, supine palpation and right lateral decubitus palpation. The abstract does not state the cohort size: N not documented, printed as such.
Summary: Prospective bedside study (Barkun 1991, vs ultrasonography; N not documented): Traube's-space percussion AUC 0.70 and palpation AUC 0.76; splenic percussion sign 79% / 46% vs Traube's percussion 62% / 72%; a concordant-positive examination (palpation plus percussion) gave 46% sensitivity / 97% specificity
Result: Traube's-space percussion and palpation were significant discriminators of splenic enlargement (AUC 0.70 ± 0.04 and 0.76 ± 0.04; p<0.001). The splenic percussion sign (sensitivity 79%, specificity 46%) was no better than Traube's-space percussion (62% / 72%). Palpation was a significant discriminator only in patients with Traube's dullness (AUC 0.87) and was more accurate in lean than obese patients (AUC 0.83 vs 0.65). No one palpation manoeuvre was superior to another, and lateral decubitus palpation added nothing after supine palpation. A concordant-positive examination gave sensitivity 46% and specificity 97%, as published.
Watch out: N not documented in the abstract — no denominator may be invented for this study. The authors' optimal sequence (percuss Traube's space first; palpate if dull) is a finding of this study, printed as such.
Source: Barkun AN et al. The bedside assessment of splenic enlargement. The American journal of medicine. 1991. PMID: 1951414. Registry ID: none in the record. MeSH: Adult · Aged · Female · Humans · Male · Middle Aged · Palpation/methods · Percussion/methods · Physical Examination/methods · ROC Curve · Splenomegaly/diagnosis/diagnostic imaging · Ultrasonography
Card 2 — Multiple-observer study (Tamayo 1993, 27 hospitalised men, 8 examiners): palpation sensitivity ranged 0%–64.3% and percussion 7.7%–75% ACROSS EXAMINERS, specificity 50%–100% and 60%–100%; pooled likelihood ratios were highest for palpation from above (2.66, labelled as such) and Castell's percussion (1.97)
Study: Prospective multiple-observer study (report 2 of 5; N = 27 — small N printed on the face)
Population: 27 hospitalised men with suspected HIV infection, each examined by 8 examiners using three palpation methods (bimanual, ballottement, palpation from above) and three percussion methods (Nixon, Castell, Barkun); ultrasonographic splenomegaly (spleen ≥13 cm) prevalence 33.3%. Small N (27) prints on the face.
Summary: Multiple-observer study (Tamayo 1993, 27 hospitalised men, 8 examiners): palpation sensitivity ranged 0%–64.3% and percussion 7.7%–75% ACROSS EXAMINERS, specificity 50%–100% and 60%–100%; pooled likelihood ratios were highest for palpation from above (2.66, labelled as such) and Castell's percussion (1.97)
Result: The sensitivity and specificity of each method varied by examiner: sensitivity ranges across examiners were 0%–64.3% for the palpation methods and 7.7%–75% for the percussion methods, with specificity ranges of 50%–100% and 60%–100%. Pooled across observers, palpation from above (likelihood ratio 2.66; 95% CI 1.52 to 4.64) and Castell's percussion (1.97; 1.22 to 3.19) carried the highest likelihood ratios (relative measures, labelled as such). Combining palpation with percussion increased diagnostic accuracy, and the interobserver variability did not appear associated with examiner experience, as published.
Watch out: Small N = 27 with 9 enlarged spleens — the examiner ranges, not any single examiner's figure, are the finding of this study; no pooled sensitivity from this shelf may be printed without that range.
Source: Tamayo SG et al. Examiner dependence on physical diagnostic tests for the detection of splenomegaly: a prospective study with multiple observers. Journal of general internal medicine. 1993. PMID: 8441078. Registry ID: none in the record. MeSH: Adult · Aged · Double-Blind Method · HIV Infections/complications · Humans · Male · Middle Aged · Observer Variation · Palpation · Percussion · Physical Examination · Prospective Studies · Reproducibility of Results · Sensitivity and Specificity · Spleen/diagnostic imaging · Splenomegaly/complications/diagnosis/diagnostic imaging · Ultrasonography
Card 3 — 80-patient accuracy study (Chongtham 1997): Middleton's manoeuvre and Castell's method most sensitive (85.7% each), Nixon's least (66.7%); supine palpation most specific (92.1%) with the highest PPV (91.7%), Castell's least specific (31.6%); ROC areas 0.93 (Middleton's), 0.92 (supine palpation), 0.75 (Castell's), 0.74 (Traube's)
Study: Accuracy study vs ultrasonography (report 3 of 5; N = 80)
Population: 80 patients admitted to a teaching hospital (mean age 31.5 years; mean Quetelet index 17.8 ± 2.6 kg/m² — a lean cohort), examined with two palpation methods (supine palpation, Middleton's manoeuvre) and three percussion methods (Traube's-space percussion, Castell's, Nixon's) against ultrasonography as the gold standard.
Summary: 80-patient accuracy study (Chongtham 1997): Middleton's manoeuvre and Castell's method most sensitive (85.7% each), Nixon's least (66.7%); supine palpation most specific (92.1%) with the highest PPV (91.7%), Castell's least specific (31.6%); ROC areas 0.93 (Middleton's), 0.92 (supine palpation), 0.75 (Castell's), 0.74 (Traube's)
Result: Sensitivity was similar for Middleton's and Castell's manoeuvres (85.7% each) and higher than the other manoeuvres; Nixon's had the least sensitivity (66.7%). Specificity was highest with supine palpation (92.1%) and least with Castell's (31.6%); supine palpation also showed the highest positive predictive value (91.7%). ROC areas were 0.93 for Middleton's manoeuvre, 0.92 for supine palpation, 0.75 for Castell's manoeuvre and 0.74 for Traube's-space percussion. The authors suggest Middleton's manoeuvre and supine palpation be routinely used in non-obese individuals, as published.
Watch out: A lean cohort (mean BMI about 17.8 kg/m²) — these sensitivity figures do not transport to obese patients (compare card 1: lean AUC 0.83 vs obese 0.65, and card 4's false negatives at higher BMI).
Source: Chongtham DS et al. Accuracy of palpation and percussion manoeuvres in the diagnosis of splenomegaly. Indian journal of medical sciences. 1997. PMID: 9567500. Registry ID: none in the record. MeSH: Adolescent · Adult · Double-Blind Method · Female · Humans · Male · Middle Aged · Palpation/methods · Percussion/methods · ROC Curve · Sensitivity and Specificity · Splenomegaly/diagnosis/diagnostic imaging · Ultrasonography
Card 4 — 100-case Traube's-space study (Dubey 2000): Traube's-space percussion (Barkun's method) sensitivity 67% / specificity 75%; palpation sensitivity 44.44% / specificity 96.87%; false negatives concentrated at higher BMI (mean 29.43 kg/m²); maximum clinical utility when both percussion and palpation were positive
Study: Accuracy study vs ultrasonography (report 4 of 5; N = 100)
Population: 100 cases selected at random from medical wards; splenic enlargement assessed by palpation and percussion of Traube's space (Barkun's method) and confirmed by abdominal ultrasonography.
Summary: 100-case Traube's-space study (Dubey 2000): Traube's-space percussion (Barkun's method) sensitivity 67% / specificity 75%; palpation sensitivity 44.44% / specificity 96.87%; false negatives concentrated at higher BMI (mean 29.43 kg/m²); maximum clinical utility when both percussion and palpation were positive
Result: Traube's-space percussion gave 24 true positives and 48 true negatives — sensitivity 67% and specificity 75% — and the BMI of the false-negative cases was significantly higher (29.43 kg/m²). Palpation had high specificity (96.87%) with a high false-negative rate and low overall sensitivity (44.44%). Interpolation of the two tests showed maximum clinical utility when both percussion and palpation were positive, as published.
Watch out: Body habitus again: the false-negative group's mean BMI was 29.43 kg/m² — a negative Traube's percussion in a heavier patient carries less weight, and that prints with the figures.
Source: Dubey S et al. Percussion of Traube's space--a useful index of splenic enlargement. The Journal of the Association of Physicians of India. 2000. PMID: 11229121. Registry ID: none in the record. MeSH: Adult · Female · Humans · Male · Palpation · Percussion · Sensitivity and Specificity · Splenomegaly/diagnosis
Card 5 — Sonographic versions beat the hands-on originals (Cessford 2018; N not documented): sonographic Castell's 91.7% sensitive (61.5% to 99.8%) vs traditional Castell's 83.3% (51.6% to 97.9%), but slower (28.8 vs 18.8 seconds); sonographic spleen tip 58.3% vs palpation 33.3%, both 100% specific
Study: Comparative study — sonographic versions of the same manoeuvres (report 5 of 5; comparison limb; N not documented in the abstract)
Population: Patients recruited from an urban haematology clinic, each examined by two clinicians trained in bedside sonography using conventional Castell's method and spleen-tip palpation plus the sonographic versions of both, against professional sonographer measurements as the reference standard. The abstract does not state the cohort size: N not documented, printed as such.
Summary: Sonographic versions beat the hands-on originals (Cessford 2018; N not documented): sonographic Castell's 91.7% sensitive (61.5% to 99.8%) vs traditional Castell's 83.3% (51.6% to 97.9%), but slower (28.8 vs 18.8 seconds); sonographic spleen tip 58.3% vs palpation 33.3%, both 100% specific
Result: The sonographic Castell's method had greater sensitivity (91.7%, 95% CI 61.5% to 99.8%) than the traditional Castell's method (83.3%, 51.6% to 97.9%) but took longer (28.8 ± 18.6 vs 18.8 ± 8.1 seconds; P=.01). Palpable and sonographic spleen-tip results were both 100% specific, with the sonographic spleen tip more sensitive (58.3%, 27.7% to 84.8%, vs 33.3%, 9.9% to 65.1%). The authors recommend combining traditional examination and sonographic techniques at the bedside, as published.
Watch out: Carded as the comparison limb, not as a sixth palpation estimate — it answers a neighbouring question (probe versions of the manoeuvres), its intervals are wide, and its N is not documented; all three facts print.
Source: Cessford T et al. Comparing Physical Examination With Sonographic Versions of the Same Examination Techniques for Splenomegaly. Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine. 2018. PMID: 29219201. Registry ID: none in the record. MeSH: Aged · Ambulatory Care Facilities · Female · Humans · Male · Middle Aged · Palpation · Physical Examination/methods · Reproducibility of Results · Sensitivity and Specificity · Spleen/diagnostic imaging · Splenomegaly/diagnosis/diagnostic imaging · Ultrasonography/methods
Card 6 — Synthesis: bedside spleen examination is specific when concordant (97%) but insensitive and examiner-bound — the same manoeuvre ranged 0%–64.3% sensitive across eight examiners, body habitus moves every figure, and probe versions of the same manoeuvres outperform the hands-on originals
Study: Synthesis
Population: All reports carded above: Barkun 1991 (N not documented), Tamayo 1993 (N=27, 8 examiners), Chongtham 1997 (N=80), Dubey 2000 (N=100) and Cessford 2018 (sonographic comparison limb; N not documented). Refusal recorded: the field's synthesising source, the 1993 Rational Clinical Examination (PMID 8411607), exists but its PubMed record has no abstract, so it is unanchorable under this desk's verification rule — it is recorded here so the count never treats it as nonexistent, and no figure on this shelf rests on it. Cross-point: pack #7721 (normal spleen dimensions on imaging) covers the reference-standard neighbour question, not bedside examination accuracy.
Summary: Synthesis: bedside spleen examination is specific when concordant (97%) but insensitive and examiner-bound — the same manoeuvre ranged 0%–64.3% sensitive across eight examiners, body habitus moves every figure, and probe versions of the same manoeuvres outperform the hands-on originals
Result: A diagnostic-accuracy shelf, not a treatment shelf. Reference standards differ slightly across studies (ultrasonographic enlargement vs ≥13 cm length) and print; combining palpation with percussion is every primary study's own remedy.
Watch out: See the individual cards for each report's limits; this synthesis adds no new data.
Source: Synthesis of the reports carded above; no additional source.