SourceMed · Shelf #7918 in the ask interface
Confrontation visual-field testing accuracy: insensitive as a screen — best single test (kinetic red target) sensitivity 74.4% / specificity 93.0%; arcuate defects 20%–51% sensitive against 90%–100% for dense hemianopias
Shelf #7918 · Eyes, skin, nose & allergy
PREDICTIVE PERFORMANCE — insensitive, defect-dependent: the best single confrontation test reaches only 74.4% sensitivity (93.0% specificity) and the best combination 78.3% / 90.1% against automated perimetry; sensitivity splits by defect type and density (arcuate 20%–51%, hemianopia 90%–100%), so a normal confrontation examination never excludes field loss; a diagnostic-accuracy stamp, not a treatment stamp
Stamped: 2026-11-28.
Evidence published: 1991–2010.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
At the bedside, how accurately do confrontation visual-field tests (finger counting, finger wiggle / kinetic finger movement, red-target kinetic perimetry and their combinations) detect visual-field loss against automated static perimetry — what sensitivity and specificity did the prospective two-examiner study of seven confrontation tests find for the best single test and the best combination, how did sensitivity split by defect location (anterior vs posterior) and defect type in the 512-field study, and at what depth of perimetric loss does confrontation detection reach 50% probability?
Balance of the evidence
A diagnostic-accuracy shelf, not a treatment shelf. The headline is insensitivity: confrontation testing misses shallow and arcuate defects (sensitivities 20%–51%) while catching dense hemianopias (90%–100%), and no card presents a normal confrontation examination as excluding field loss. Defect type, density and quadrant print with every figure. The reference standard is automated perimetry in ophthalmology-clinic spectra (mean deviation −5.91 dB in the 2010 study), so the figures do not transport to screening of asymptomatic people. Combining tests is the sources' own remedy and prints as such. A same-title 2011 report (PMID 21444908) is an apparent duplicate publication of the 2010 study and is counted once, as the 2010 report.
MeSH: Adult · Aged · Diagnosis, Differential · Eye Diseases/diagnosis · Female · Humans · Male · Middle Aged · Neurologic Examination/methods · Patient Selection · Prospective Studies · Sensitivity and Specificity · Sensory Thresholds/physiology · Visual Field Tests/methods · Visual Fields/physiology · Adolescent · Child · Reproducibility of Results · Retrospective Studies · Vision Disorders/diagnosis/physiopathology · Vision Tests · Visual Field Tests · Aged, 80 and over · Predictive Value of Tests · Vision Disorders/diagnosis · Visual Fields
Cards (4)
Card 1 — Prospective two-examiner study (Kerr 2010, 301 eyes of 163 ophthalmology-clinic patients, seven confrontation tests vs SITA-standard 24-2 Humphrey perimetry): most individual tests insensitive; kinetic testing with a red target was the best single test (sensitivity 74.4%, specificity 93.0%), and combined with static finger wiggle reached 78.3% at specificity 90.1%
Study: Prospective diagnostic-accuracy study — seven confrontation tests, two masked examiners (report 1 of 3; 301 eyes of 163 patients)
Population: 163 patients prospectively recruited from ophthalmology clinics (301 eyes; average mean deviation −5.91 ± 7.72 dB), each assessed by two examiners masked to the automated perimetry results and to each other, using seven common confrontation visual-field tests in randomised order.
Summary: Prospective two-examiner study (Kerr 2010, 301 eyes of 163 ophthalmology-clinic patients, seven confrontation tests vs SITA-standard 24-2 Humphrey perimetry): most individual tests insensitive; kinetic testing with a red target was the best single test (sensitivity 74.4%, specificity 93.0%), and combined with static finger wiggle reached 78.3% at specificity 90.1%
Result: Most confrontation tests were insensitive to the identification of field loss, and sensitivity and specificity varied with the type, density and cause of the defect. Kinetic testing with a red target provided the highest sensitivity (74.4%) and specificity (93.0%) of any individual test, and combined with static finger wiggle testing achieved a sensitivity of 78.3% while retaining a specificity of 90.1%. The authors conclude that confrontation tests performed individually are a poor screening test and that combining tests is a simple, practical way to improve sensitivity, as published.
Watch out: A same-title 2011 report (PMID 21444908) is treated as an apparent duplicate publication of this study and is NOT counted — this study rests on the 2010 report alone. The spectrum is an ophthalmology clinic (mean deviation −5.91 dB); the figures do not transport to screening of asymptomatic people.
Source: Kerr NM et al. Diagnostic accuracy of confrontation visual field tests. Neurology. 2010. PMID: 20385890. Registry ID: none in the record. MeSH: Adult · Aged · Diagnosis, Differential · Eye Diseases/diagnosis · Female · Humans · Male · Middle Aged · Neurologic Examination/methods · Patient Selection · Prospective Studies · Sensitivity and Specificity · Sensory Thresholds/physiology · Visual Field Tests/methods · Visual Fields/physiology
Card 2 — 512-field study (Johnson 1991, vs automated static perimetry): sensitivity excluding patchy defects was 40% for anterior defects, 68.3% for posterior defects and 50% combined — but 75%–100% for altitudinal loss, central / centrocecal scotoma and homonymous hemianopia against 20%–50% for arcuate scotoma and bitemporal hemianopia; specificity 93.4%
Study: Accuracy study vs automated static perimetry (report 2 of 3; 512 visual fields)
Population: 512 visual fields assessed by confrontation visual-field testing with automated static perimetry as the reference standard, analysed by defect location (anterior vs posterior) and defect type.
Summary: 512-field study (Johnson 1991, vs automated static perimetry): sensitivity excluding patchy defects was 40% for anterior defects, 68.3% for posterior defects and 50% combined — but 75%–100% for altitudinal loss, central / centrocecal scotoma and homonymous hemianopia against 20%–50% for arcuate scotoma and bitemporal hemianopia; specificity 93.4%
Result: Sensitivity excluding patchy defects was 40% for anterior visual-field defects, 68.3% for posterior defects and 50% for both combined. By defect type, confrontation testing had high sensitivity (75% to 100%) for altitudinal visual loss, central/centrocecal scotoma and homonymous hemianopia, but was fairly insensitive (20% to 50%) for arcuate scotoma and bitemporal hemianopia. Specificity was 93.4%, with a positive predictive value of 72.6% and a negative predictive value of 75.7%, as published.
Watch out: The headline is the split: confrontation catches dense posterior defects and misses exactly the shallow and arcuate defects of glaucoma, parasellar tumours and compressive optic neuropathies that the authors warn about — no single sensitivity figure describes this test, and defect type prints with every figure.
Source: Johnson LN et al. The accuracy of confrontation visual field test in comparison with automated perimetry. Journal of the National Medical Association. 1991. PMID: 1800764. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Child · Humans · Middle Aged · Reproducibility of Results · Retrospective Studies · Vision Disorders/diagnosis/physiopathology · Vision Tests · Visual Field Tests · Visual Fields/physiology
Card 3 — Density study (Shahinfar 1995, 72 patients at a university eye centre, vs full-threshold Humphrey perimetry): overall sensitivity 63% when detection of one abnormal quadrant counted, but only 38% at quadrant level; by defect type 51% (arcuate), 67% (constriction), 78% (altitudinal) and 90% (hemianopia); the estimated loss at which detection probability reached 50% was −26 dB for superior and −19 dB for inferior quadrants; specificity 97%, PPV 96%
Study: Prospective comparison vs full-threshold Humphrey perimetry (report 3 of 3; 72 patients, one field each)
Population: 72 patients with a variety of neurologic and ophthalmologic conditions at a university eye centre over 3 months; one visual field from each patient analysed against full-threshold Humphrey automated static perimetry (C24-2 or C30-2).
Summary: Density study (Shahinfar 1995, 72 patients at a university eye centre, vs full-threshold Humphrey perimetry): overall sensitivity 63% when detection of one abnormal quadrant counted, but only 38% at quadrant level; by defect type 51% (arcuate), 67% (constriction), 78% (altitudinal) and 90% (hemianopia); the estimated loss at which detection probability reached 50% was −26 dB for superior and −19 dB for inferior quadrants; specificity 97%, PPV 96%
Result: Overall sensitivity for detecting an abnormal field was 63% on full-field analysis (detection of just one abnormal quadrant), but sensitivity for detecting abnormal quadrants was poor at 38%. Sensitivity varied by defect type (arcuate 51%, constriction 67%, altitudinal 78%, hemianopia 90%) and was lower for superior than inferior quadrant defects. The estimated probability of detecting an abnormal quadrant reached 50% only at a sensitivity loss of −26 dB (superior quadrants) and −19 dB (inferior quadrants) from age-matched healthy values. Confrontation testing was relatively insensitive unless a moderate-to-dense defect was present, but identified defects were often real (specificity 97%, positive predictive value 96%), as published.
Watch out: Detection is a function of defect depth and quadrant: moderate-to-dense loss is required before confrontation performs — a normal confrontation result over a shallow defect is the expected miss, printed as such.
Source: Shahinfar S et al. Confrontation visual field loss as a function of decibel sensitivity loss on automated static perimetry. Implications on the accuracy of confrontation visual field testing. Ophthalmology. 1995. PMID: 7777293. Registry ID: none in the record. MeSH: Adult · Aged · Aged, 80 and over · Female · Humans · Male · Middle Aged · Predictive Value of Tests · Prospective Studies · Reproducibility of Results · Sensitivity and Specificity · Vision Disorders/diagnosis · Visual Field Tests/methods · Visual Fields
Card 4 — Synthesis: confrontation testing is a specific but insensitive bedside test — it finds dense hemianopias (90%–100%) and misses shallow and arcuate loss (20%–51%); combining tests (kinetic red target plus static finger wiggle, 78.3% / 90.1%) is the sources' own remedy, and a normal confrontation examination never excludes field loss
Study: Synthesis
Population: All reports carded above: Kerr 2010 (301 eyes of 163 patients), Johnson 1991 (512 visual fields) and Shahinfar 1995 (72 fields). Not counted: PMID 21444908, a same-title 2011 report treated as an apparent duplicate publication of the Kerr 2010 study — counted once, as the 2010 report. Cross-point: pack #7184 (automated perimetry sensitivity norms in healthy people) covers the reference instrument's physiology, not the bedside test's accuracy.
Summary: Synthesis: confrontation testing is a specific but insensitive bedside test — it finds dense hemianopias (90%–100%) and misses shallow and arcuate loss (20%–51%); combining tests (kinetic red target plus static finger wiggle, 78.3% / 90.1%) is the sources' own remedy, and a normal confrontation examination never excludes field loss
Result: A diagnostic-accuracy shelf, not a treatment shelf. The reference standard throughout is automated perimetry in ophthalmology-clinic spectra, and defect type, density and quadrant print with every figure.
Watch out: See the individual cards for each report's limits; this synthesis adds no new data.
Source: Synthesis of the reports carded above; no additional source.