SourceMed · Shelf #7923 in the ask interface

ROSIER scale: sensitivity holds (0.88 pooled) but specificity falls from 86% to 41% across settings — false positives among mimics are the weakness

Shelf #7923 · Brain, stroke & mind

PREDICTIVE PERFORMANCE: ROSIER sensitivity 92–93% / specificity 83–86% in the originators' cohorts, pooled 0.88 / 0.66, specificity falling to 41% in Hong Kong; a diagnostic-accuracy stamp, not a treatment stamp

Stamped: 2026-11-28.

Evidence published: 2005–2020.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In patients with suspected acute stroke, how accurately does the ROSIER scale (Recognition of Stroke in the Emergency Room — two history items scored negatively (loss of consciousness, seizure activity) and five neurological signs scored positively (face, arm, leg weakness, speech disturbance, visual-field defect); total −2 to +5, positive above 0) distinguish stroke from its mimics — what sensitivity and specificity did the development cohort and the prospective validation find, what pooled figures does the 14-study meta-analysis give, and how far did specificity fall in the Hong Kong Chinese validation?

Balance of the evidence

ROSIER distinguished stroke from mimics at sensitivity 92% / specificity 86% in development and 93% / 83% on prospective validation (originators' own report), but pooled specificity across 14 studies is only 0.66 and in the Hong Kong Chinese validation specificity fell to 41% with AUC 0.723. The specificity gradient is the content, and no pooled figure prints without the mimic spectrum of its cohort. This is a diagnostic-accuracy shelf, not a treatment shelf: no card implies ROSIER-guided referral speeds thrombolysis.

MeSH: Aged · Cohort Studies · Databases, Factual · Diagnosis, Differential · Emergency Medical Services · Emergency Service, Hospital · False Negative Reactions · False Positive Reactions · Female · Humans · Ischemic Attack, Transient/diagnosis · Logistic Models · Male · Movement Disorders/diagnosis/etiology · Prospective Studies · Reproducibility of Results · Stroke/diagnosis/physiopathology · Predictive Value of Tests · Sensitivity and Specificity · Severity of Illness Index · Stroke/diagnosis · Asian People · Hong Kong · Multivariate Analysis

Cards (4)

Card 1 — Development and prospective validation (Nor 2005, The Lancet Neurology — programme-labelled: the originators' own report; development 343 suspected-stroke patients, validation 173 consecutive referrals): at a cut-off above 0, sensitivity 92% / specificity 86% internally and 93% (89 to 97) / 83% (77 to 89) prospectively

Study: Development and prospective validation — programme-labelled (originators' own report)

Population: Development: 343 suspected-stroke patients (159 stroke, 167 non-stroke, 32 TIA). Prospective validation: 173 consecutive referrals (88 stroke, 59 non-stroke, 26 TIA). Common mimics were seizures (23%), syncope (23%) and sepsis (10%).

Summary: Development and prospective validation (Nor 2005, The Lancet Neurology — programme-labelled: the originators' own report; development 343 suspected-stroke patients, validation 173 consecutive referrals): at a cut-off above 0, sensitivity 92% / specificity 86% internally and 93% (89 to 97) / 83% (77 to 89) prospectively

Result: At a cut-off above 0 the scale had sensitivity 92%, specificity 86%, PPV 88% and NPV 91% internally; prospective validation gave sensitivity 93% (95% CI 89 to 97), specificity 83% (77 to 89), PPV 90% and NPV 88%, as published.

Watch out: The derivation's referral-appropriateness observation is the originators' own and prints as such; TIA handling differed across cohorts.

Source: Nor AM et al. The Recognition of Stroke in the Emergency Room (ROSIER) scale: development and validation of a stroke recognition instrument. The Lancet. Neurology. 2005. PMID: 16239179. Registry ID: none in the record. MeSH: Aged · Cohort Studies · Databases, Factual · Diagnosis, Differential · Emergency Medical Services · Emergency Service, Hospital · False Negative Reactions · False Positive Reactions · Female · Humans · Ischemic Attack, Transient/diagnosis · Logistic Models · Male · Movement Disorders/diagnosis/etiology · Prospective Studies · Reproducibility of Results · Stroke/diagnosis/physiopathology

Card 2 — Meta-analysis (Han 2020, BMC Neurology — 14 studies, 15 datasets): pooled sensitivity 0.88 (0.83 to 0.91), specificity 0.66 (0.52 to 0.77), diagnostic odds ratio 13.86 (labelled as such) and AUC 0.88 (0.85 to 0.90)

Study: Systematic review and meta-analysis

Population: 14 studies (15 datasets) evaluating ROSIER accuracy, synthesised with a bivariate mixed-effects model.

Summary: Meta-analysis (Han 2020, BMC Neurology — 14 studies, 15 datasets): pooled sensitivity 0.88 (0.83 to 0.91), specificity 0.66 (0.52 to 0.77), diagnostic odds ratio 13.86 (labelled as such) and AUC 0.88 (0.85 to 0.90)

Result: Pooled sensitivity was 0.88 (95% CI 0.83 to 0.91), specificity 0.66 (0.52 to 0.77), diagnostic odds ratio 13.86 (labelled as such) and AUC 0.88 (0.85 to 0.90); at a 60% pre-test probability a positive score raised post-test probability to 79% and a negative lowered it to 22%, as published.

Watch out: Pooled specificity (0.66) sits well below the originators' figures — the gradient, not any single figure, is the finding.

Source: Han F et al. A systematic review and meta-analysis to evaluate the diagnostic accuracy of recognition of stroke in the emergency department (ROSIER) scale. BMC neurology. 2020. PMID: 32811447. Registry ID: none in the record. MeSH: Emergency Service, Hospital · Humans · Predictive Value of Tests · Sensitivity and Specificity · Severity of Illness Index · Stroke/diagnosis

Card 3 — Hong Kong validation (Jiang 2014, PLoS ONE — prospective, 715 suspected-stroke patients, 52% acute cerebrovascular disease): at >0 sensitivity 87% (83 to 90) but specificity only 41% (36 to 47), AUC 0.723 — materially worse discrimination, driven by the specificity fall

Study: Prospective external validation — Hong Kong

Population: 715 suspected-stroke patients in a Hong Kong emergency department; 371 (52%) had acute cerebrovascular disease and 344 were mimics (spinal neuropathy, dementia, labyrinthitis and sepsis predominating).

Summary: Hong Kong validation (Jiang 2014, PLoS ONE — prospective, 715 suspected-stroke patients, 52% acute cerebrovascular disease): at >0 sensitivity 87% (83 to 90) but specificity only 41% (36 to 47), AUC 0.723 — materially worse discrimination, driven by the specificity fall

Result: At the >0 cut-off sensitivity was 87% (95% CI 83 to 90), specificity 41% (36 to 47), PPV 62%, NPV 75% and AUC 0.723, as published.

Watch out: Mimic spectrum differs by setting and prints with the figures; this cohort's mimics were not the derivation's seizure/syncope/sepsis mix.

Source: Jiang HL et al. Evaluation of the Recognition of Stroke in the Emergency Room (ROSIER) scale in Chinese patients in Hong Kong. PloS one. 2014. PMID: 25343496. Registry ID: none in the record. MeSH: Aged · Asian People · Emergency Service, Hospital · Female · Hong Kong · Humans · Logistic Models · Male · Multivariate Analysis · Severity of Illness Index · Stroke/diagnosis

Card 4 — Synthesis: ROSIER sensitivity holds up (87–93% across cohorts, 0.88 pooled) but specificity does not transport (86% development, 83% validation, 0.66 pooled, 41% in Hong Kong) — the scale's weakness is false positives among mimics

Study: Synthesis

Population: All reports carded on this shelf: Nor 2005, Han 2020 and Jiang 2014.

Summary: Synthesis: ROSIER sensitivity holds up (87–93% across cohorts, 0.88 pooled) but specificity does not transport (86% development, 83% validation, 0.66 pooled, 41% in Hong Kong) — the scale's weakness is false positives among mimics

Result: This is a diagnostic-accuracy shelf, not a treatment shelf.

Watch out: See the individual cards for each report's limits; this synthesis adds no new data.

Source: Synthesis of the reports carded above; no additional source.