Elbow extension test (FLOOR-RISK — exactly 2 reports): sensitivity 96.8%, NPV 98.4% adults / 95.8% children — but 17 fractures occurred in fully-extending patients

Shelf #7927 · Bones & joints

PREDICTIVE PERFORMANCE — FLOOR-RISK, exactly 2 reports (1 primary + 1 systematic review whose set includes it): elbow extension sensitivity 96.8% / specificity 48.5%, NPV 98.4% adults / 95.8% children, 17 fractures missed in fully-extending patients; a diagnostic-accuracy stamp, not a discharge endorsement

Stamped: 2026-11-28.

Evidence published: 2008–2023.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

After elbow trauma, how accurately does the elbow extension test (ability to fully extend the elbow, alone and combined with point tenderness and range-of-motion variants) rule out fracture against radiography or clinical follow-up — what sensitivity, specificity and negative predictive values did the multicentre prospective study of 1,740 eligible adults and children find overall and by age group, and what sensitivity range and specificity range does the systematic review report across its 12 studies? (FLOOR-RISK — rests on exactly 2 reports: one large multicentre primary and one systematic review whose 12-study set includes that primary.)

Balance of the evidence

FLOOR-RISK — this shelf rests on exactly 2 reports (one large multicentre primary, 1,740 eligible participants, and one systematic review of 12 studies whose set includes that primary), and that exact basis prints here and on every card. Overall sensitivity was 96.8% and specificity 48.5% in the primary; negative predictive value was 98.4% in adults and 95.8% in children. The miss pattern prints: 17 fractures occurred in fully-extending patients and 2 adults with olecranon fractures needed a change in treatment — a negative test reduces but does not eliminate fracture probability, particularly in children. Adult and child figures never mix. This is a diagnostic-accuracy shelf, not a discharge-pathway endorsement.

MeSH: Adult · Aged · Child · Child, Preschool · Fractures, Bone/diagnosis/physiopathology · Humans · Infant · Middle Aged · Physical Examination/methods/standards · Prospective Studies · Range of Motion, Articular/physiology · Young Adult · Elbow Injuries

Cards (4)

Card 1 — FLOOR-RISK report 1 of exactly 2 — multicentre prospective study (Appelboam 2008, BMJ — 5 English emergency departments, 1,740 eligible adults and children; 602 could fully extend the elbow and 17 of them had a fracture): overall sensitivity 96.8% (95.0 to 98.2) and specificity 48.5% (45.6 to 51.4); NPV 98.4% (96.3 to 99.5) in adults and 95.8% (92.6 to 97.8) in children, negative likelihood ratios 0.03 and 0.11 respectively (labelled as such)

Study: Multicentre prospective validation study (FLOOR-RISK report 1 of exactly 2)

Population: 1,740 eligible participants (of 2,127 presenting) with acute elbow injury at 5 English emergency departments; reference standard radiography or clinical follow-up at 7–10 days.

Summary: FLOOR-RISK report 1 of exactly 2 — multicentre prospective study (Appelboam 2008, BMJ — 5 English emergency departments, 1,740 eligible adults and children; 602 could fully extend the elbow and 17 of them had a fracture): overall sensitivity 96.8% (95.0 to 98.2) and specificity 48.5% (45.6 to 51.4); NPV 98.4% (96.3 to 99.5) in adults and 95.8% (92.6 to 97.8) in children, negative likelihood ratios 0.03 and 0.11 respectively (labelled as such)

Result: Overall sensitivity was 96.8% (95% CI 95.0 to 98.2) and specificity 48.5% (45.6 to 51.4); negative predictive value was 98.4% (96.3 to 99.5) in adults and 95.8% (92.6 to 97.8) in children, with negative likelihood ratios of 0.03 and 0.11 respectively (labelled as such), as published. Two adult patients with olecranon fractures needed a change in treatment.

Watch out: FLOOR-RISK basis, printed exactly: exactly 2 reports — this primary and the systematic review on card 2, whose 12-study set includes this primary. The 17 missed fractures print beside any sensitivity headline.

Source: Appelboam A et al. Elbow extension test to rule out elbow fracture: multicentre, prospective validation and observational study of diagnostic accuracy in adults and children. BMJ (Clinical research ed.). 2008. PMID: 19066257. Registry ID: none in the record. MeSH: Adult · Aged · Child · Child, Preschool · Fractures, Bone/diagnosis/physiopathology · Humans · Infant · Middle Aged · Physical Examination/methods/standards · Prospective Studies · Range of Motion, Articular/physiology · Young Adult · Elbow Injuries

Card 2 — FLOOR-RISK report 2 of exactly 2 — systematic review (Breda 2023, Clinics in Shoulder and Elbow — 12 studies, 4,485 patients): in adults the tests were very sensitive (up to 98.6% (95.0 to 99.8)) while specificity ranged widely (24.0% to 69.4%); overall study quality was medium risk of bias. This report has no MeSH in its PubMed record — stated on its source line

Study: Systematic review of clinical tests (FLOOR-RISK report 2 of exactly 2)

Population: 12 studies, 4,485 patients with suspected traumatic elbow fracture, covering the elbow extension test, full range-of-motion test and extension-plus-point-tenderness variants against imaging.

Summary: FLOOR-RISK report 2 of exactly 2 — systematic review (Breda 2023, Clinics in Shoulder and Elbow — 12 studies, 4,485 patients): in adults the tests were very sensitive (up to 98.6% (95.0 to 99.8)) while specificity ranged widely (24.0% to 69.4%); overall study quality was medium risk of bias. This report has no MeSH in its PubMed record — stated on its source line

Result: In adults the tests were very sensitive, with values up to 98.6% (95% CI 95.0 to 99.8), while specificity ranged from 24.0% to 69.4%; the authors conclude a negative test usefully excludes fracture in most cases while positive results are uninformative, as published.

Watch out: FLOOR-RISK basis, printed exactly: this review's 12-study set includes the primary on card 1 — the two reports are not independent confirmations. Specificity's wide range prints as a range, never a pooled point.

Source: Breda G et al. Diagnostic accuracy of clinical tests to rule out elbow fracture: a systematic review. Clinics in shoulder and elbow. 2023. PMID: 35971600. Registry ID: none in the record. MeSH: none in the record

Card 3 — Cross-report summary of the two carded reports — not an additional report (source line repeats the multicentre primary for reference): sensitivity is high in both reports (96.8% overall; up to 98.6% in adults in the review) and specificity is low and variable in both (48.5%; 24.0%–69.4%) — the test's value is only in its negative result, and even that missed 17 fractures

Study: Cross-report summary of the two carded reports — not an additional report (FLOOR-RISK)

Population: The two reports carded above only: Appelboam 2008 (1,740 eligible participants) and Breda 2023 (12 studies, 4,485 patients). No third report was carried through verification for this row — that is the FLOOR-RISK basis, stated here so the count can never be misread.

Summary: Cross-report summary of the two carded reports — not an additional report (source line repeats the multicentre primary for reference): sensitivity is high in both reports (96.8% overall; up to 98.6% in adults in the review) and specificity is low and variable in both (48.5%; 24.0%–69.4%) — the test's value is only in its negative result, and even that missed 17 fractures

Result: Read together: a patient who cannot fully extend the elbow has a nearly 50% chance of fracture in the primary cohort and needs radiography; a patient who can fully extend still carried a 1.6% (adults) to 4.2% (children) fracture probability, and safety-netting return advice is part of the primary report's own conclusion.

Watch out: This card adds no evidence; it exists so the 2-report basis and the miss pattern are unmissable on the face of the shelf.

Source: Appelboam A et al. Elbow extension test to rule out elbow fracture: multicentre, prospective validation and observational study of diagnostic accuracy in adults and children. BMJ (Clinical research ed.). 2008. PMID: 19066257. Registry ID: none in the record. MeSH: Adult · Aged · Child · Child, Preschool · Fractures, Bone/diagnosis/physiopathology · Humans · Infant · Middle Aged · Physical Examination/methods/standards · Prospective Studies · Range of Motion, Articular/physiology · Young Adult · Elbow Injuries

Card 4 — Synthesis: FLOOR-RISK — this shelf rests on exactly 2 reports (one large multicentre primary and one systematic review whose set includes that primary), and that exact basis prints here and on every card. Within that base: full elbow extension is sensitive (96.8%) but not fracture-proof — 17 fractures in fully-extending patients, NPV 95.8% in children — and a positive (non-extending) result is uninformative because specificity is 48.5% and variable

Study: Synthesis

Population: All reports carded on this shelf: Appelboam 2008 and Breda 2023 — exactly 2 reports, the review's set including the primary.

Summary: Synthesis: FLOOR-RISK — this shelf rests on exactly 2 reports (one large multicentre primary and one systematic review whose set includes that primary), and that exact basis prints here and on every card. Within that base: full elbow extension is sensitive (96.8%) but not fracture-proof — 17 fractures in fully-extending patients, NPV 95.8% in children — and a positive (non-extending) result is uninformative because specificity is 48.5% and variable

Result: This is a diagnostic-accuracy shelf (FLOOR-RISK), not a discharge-pathway endorsement. Failed verification of this exact 2-report basis would have stopped the build; the basis verified as stated, so the shelf is built as FLOOR-RISK with the basis on its face.

Watch out: See the individual cards for each report's limits; this synthesis adds no new data.

Source: Synthesis of the reports carded above; no additional source.