SourceMed · Shelf #7933 in the ask interface
Babinski sign (FLOOR-RISK — exactly 2 primaries): ~50% sensitive in both, specific when present (99% / 85.8% by spectrum) — a negative sign excludes nothing
Shelf #7933 · Brain, stroke & mind
PREDICTIVE PERFORMANCE — FLOOR-RISK, exactly 2 primary reports: Babinski sensitivity 50.8% / 49.6% in both reports, specificity 99% vs 85.8% by spectrum, positive likelihood ratio 51.8 (labelled as such); a diagnostic-accuracy stamp, not a treatment stamp
Stamped: 2026-11-28.
Evidence published: 2014–2018.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
How accurately does the Babinski sign (extensor plantar response) identify pyramidal / corticospinal tract dysfunction against expert clinical diagnosis with imaging — what sensitivity, specificity, positive likelihood ratio and inter-observer variability did the filmed two-neurologist study of 107 patients find, and how did the sign compare with finger and foot tapping for sensitivity, specificity and student–neurologist agreement in the 375-participant three-group study? (FLOOR-RISK — rests on exactly 2 primary reports.)
Balance of the evidence
FLOOR-RISK — this shelf rests on exactly 2 primary reports, and that exact basis prints here and on every card. The two studies agree on sensitivity (~50%: 50.8% and 49.6%) and disagree on specificity (99% vs 85.8%) because their spectra differ (neurology referrals vs a three-group design including healthy relatives) — the spectra print and the figures never merge. The reliability paradox prints: the sign is highly specific when a neurologist elicits it (positive likelihood ratio 51.8, labelled as such), inter-observer variability was 0.73, yet the same examiner re-reading the filmed response agreed with themselves only moderately (intra-observer 0.571 and 0.467), and student–neurologist agreement was κ 0.45 for Babinski against κ 0.83 for finger / foot tapping (which was also more sensitive, 79.5% / 88.4%). Reference standards differ and print. This is a diagnostic-accuracy shelf, not a treatment shelf.
MeSH: Adult · Aged · Female · Humans · Male · Middle Aged · Pyramidal Tracts/pathology · ROC Curve · Reflex, Babinski/physiology · Retrospective Studies · Spinal Cord Diseases/diagnosis · Statistics, Nonparametric · Fingers · Neurologic Examination/methods · Pyramidal Tracts/injuries · Reflex, Babinski · Reproducibility of Results · Sensitivity and Specificity · Spinal Cord Injuries/diagnosis/physiopathology · Young Adult
Cards (4)
Card 1 — FLOOR-RISK report 1 of exactly 2 — filmed two-neurologist study (Isaza Jaramillo 2014, Journal of the Neurological Sciences — 107 adult neurology patients, two neurologists eliciting the sign independently and blinded against an expert reference diagnosis incorporating imaging): sensitivity 50.8% (41.5 to 60.1), specificity 99% (97.7 to 100) and positive likelihood ratio 51.8 (16.6 to 161.2) (labelled as such); inter-observer variability 0.73 (0.598 to 0.858) while intra-observer reliability was only 0.571 and 0.467 for the two examiners
Study: Diagnostic-accuracy and reliability study (FLOOR-RISK report 1 of exactly 2)
Population: 107 adult hospitalised and outpatient neurology subjects; reference standard was the blinded independent diagnosis of an expert neurologist based on history, examination, imaging and complementary tests. Each examination was filmed to quantify intra-observer variability.
Summary: FLOOR-RISK report 1 of exactly 2 — filmed two-neurologist study (Isaza Jaramillo 2014, Journal of the Neurological Sciences — 107 adult neurology patients, two neurologists eliciting the sign independently and blinded against an expert reference diagnosis incorporating imaging): sensitivity 50.8% (41.5 to 60.1), specificity 99% (97.7 to 100) and positive likelihood ratio 51.8 (16.6 to 161.2) (labelled as such); inter-observer variability 0.73 (0.598 to 0.858) while intra-observer reliability was only 0.571 and 0.467 for the two examiners
Result: Sensitivity was 50.8% (95% CI 41.5 to 60.1), specificity 99% (97.7 to 100) and positive likelihood ratio 51.8 (16.6 to 161.2) (labelled as such); inter-observer variability was 0.73 (0.598 to 0.858) and intra-observer reliability 0.571 and 0.467 for the two examiners, as published.
Watch out: FLOOR-RISK basis, printed exactly: exactly 2 primary reports — this study and the three-group study on card 2. Low sensitivity prints: absence of the sign requires further evaluation if pyramidal dysfunction is suspected.
Source: Isaza Jaramillo SP et al. Accuracy of the Babinski sign in the identification of pyramidal tract dysfunction. Journal of the neurological sciences. 2014. PMID: 24906707. Registry ID: none in the record. MeSH: Adult · Aged · Female · Humans · Male · Middle Aged · Pyramidal Tracts/pathology · ROC Curve · Reflex, Babinski/physiology · Retrospective Studies · Spinal Cord Diseases/diagnosis · Statistics, Nonparametric
Card 2 — FLOOR-RISK report 2 of exactly 2 — three-group study (Appasamy 2018, Neurology India — 375 participants in three groups of 125: corticospinal lesions, non-CST neurological illness, healthy relatives): the Babinski sign had sensitivity 49.6% and specificity 85.8%, against finger / foot tapping at 79.5% / 88.4%; inter-observer agreement between medical students and a neurologist was κ 0.83 for tapping but only κ 0.45 for the Babinski sign
Study: Three-group accuracy and reliability study (FLOOR-RISK report 2 of exactly 2)
Population: 375 participants in three groups of 125: individuals with corticospinal tract lesions (clinical plus neuroimaging), individuals with non-CST neurological illness, and healthy relatives.
Summary: FLOOR-RISK report 2 of exactly 2 — three-group study (Appasamy 2018, Neurology India — 375 participants in three groups of 125: corticospinal lesions, non-CST neurological illness, healthy relatives): the Babinski sign had sensitivity 49.6% and specificity 85.8%, against finger / foot tapping at 79.5% / 88.4%; inter-observer agreement between medical students and a neurologist was κ 0.83 for tapping but only κ 0.45 for the Babinski sign
Result: Babinski sensitivity was 49.6% and specificity 85.8%; finger and foot tapping sensitivity was 79.5% and specificity 88.4%; student–neurologist agreement was κ 0.83 for tapping and κ 0.45 for the Babinski sign, as published.
Watch out: FLOOR-RISK basis, printed exactly: exactly 2 primary reports carry this shelf. Specificity here (85.8%) is lower than card 1's (99%) because the spectrum includes healthy relatives and non-CST illness — the figures never merge.
Source: Appasamy PT et al. Accuracy and reliability of Babinski sign versus finger and foot tapping in the diagnosis of corticospinal tract lesions. Neurology India. 2018. PMID: 30233007. Registry ID: none in the record. MeSH: Adult · Female · Fingers · Humans · Male · Middle Aged · Neurologic Examination/methods · Pyramidal Tracts/injuries · Reflex, Babinski · Reproducibility of Results · Sensitivity and Specificity · Spinal Cord Injuries/diagnosis/physiopathology · Young Adult
Card 3 — Cross-report summary of the two carded reports — not an additional report (source line repeats the filmed two-neurologist study for reference): both reports put sensitivity at ~50% — the sign misses about half of pyramidal / corticospinal dysfunction in both spectra — while specificity is spectrum-bound (99% in neurology referrals, 85.8% in a three-group design)
Study: Cross-report summary of the two carded reports — not an additional report (FLOOR-RISK)
Population: The two reports carded above only: Isaza Jaramillo 2014 (107 neurology patients) and Appasamy 2018 (375 participants in three groups). No third primary report was carried through verification for this row — that is the FLOOR-RISK basis, stated here so the count can never be misread.
Summary: Cross-report summary of the two carded reports — not an additional report (source line repeats the filmed two-neurologist study for reference): both reports put sensitivity at ~50% — the sign misses about half of pyramidal / corticospinal dysfunction in both spectra — while specificity is spectrum-bound (99% in neurology referrals, 85.8% in a three-group design)
Result: Read together: a positive Babinski sign elicited by a neurologist is strong evidence of pyramidal tract dysfunction, but a negative sign excludes nothing in either study, and the sign's reliability (intra-observer 0.467–0.571; student–neurologist κ 0.45) is weaker than its reputation and weaker than tapping tests in the same study.
Watch out: This card adds no evidence; it exists so the 2-report basis and the sensitivity agreement / specificity disagreement structure are unmissable on the face of the shelf.
Source: Isaza Jaramillo SP et al. Accuracy of the Babinski sign in the identification of pyramidal tract dysfunction. Journal of the neurological sciences. 2014. PMID: 24906707. Registry ID: none in the record. MeSH: Adult · Aged · Female · Humans · Male · Middle Aged · Pyramidal Tracts/pathology · ROC Curve · Reflex, Babinski/physiology · Retrospective Studies · Spinal Cord Diseases/diagnosis · Statistics, Nonparametric
Card 4 — Synthesis: FLOOR-RISK — this shelf rests on exactly 2 primary reports, and that exact basis prints here and on every card. Within that base: the Babinski sign is specific (99% / 85.8% by spectrum) but only ~50% sensitive in both reports, with moderate self-agreement — a positive sign rules in far better than a negative sign rules out
Study: Synthesis
Population: All reports carded on this shelf: Isaza Jaramillo 2014 and Appasamy 2018 — exactly 2 primary reports.
Summary: Synthesis: FLOOR-RISK — this shelf rests on exactly 2 primary reports, and that exact basis prints here and on every card. Within that base: the Babinski sign is specific (99% / 85.8% by spectrum) but only ~50% sensitive in both reports, with moderate self-agreement — a positive sign rules in far better than a negative sign rules out
Result: This is a diagnostic-accuracy shelf (FLOOR-RISK), not a treatment shelf. Failed verification of this exact 2-report basis would have stopped the build; the basis verified as stated, so the shelf is built as FLOOR-RISK with the basis on its face.
Watch out: See the individual cards for each report's limits; this synthesis adds no new data.
Source: Synthesis of the reports carded above; no additional source.