SourceMed · Shelf #7963 in the ask interface

AD8 for dementia: 91% pooled sensitivity informant-completed, 57% for MCI self-completed — one derivation plus four overlapping syntheses; who completes the form is part of the measurement

Shelf #7963 · Brain, stroke & mind

PREDICTIVE PERFORMANCE: informant-completed AD8 pooled sensitivity 91% for dementia (specificity 64%) and 80% / 79% for MCI, against participant-completed 57% sensitivity for MCI — on 1 derivation + 4 overlapping syntheses with low overall certainty in the overview; a screening-accuracy stamp, not a treatment stamp

Stamped: 2026-11-28.

Evidence published: 2005–2023.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

How accurately does the AD8 (Ascertain Dementia 8 — eight yes / no informant items on change in memory, orientation, judgement and function; positive at ≥2) detect dementia and mild cognitive impairment against clinical diagnosis — what sensitivity and specificity did the original informant-interview derivation find for very mild dementia, what pooled figures do the two meta-analyses give for informant-completed vs participant-completed administration, and how did the instrument perform across the primary-care studies in the Swedish-context systematic review?

Balance of the evidence

Composition printed on the face: this shelf rests on 1 derivation report plus 4 syntheses whose primary-study sets overlap — the syntheses are counted as syntheses, never as independent confirmations. Who completes the form is part of the measurement: informant-completed AD8 pooled at 91% sensitivity for dementia, while participant-completed forms pooled at only 57% sensitivity for mild cognitive impairment. Target condition prints with every figure (very mild dementia vs MCI vs dementia — the pooled pairs differ by target), and the overview of reviews graded overall certainty low. This is a screening-accuracy shelf, not a treatment shelf. Cross-point: IQCODE #7921 — the other informant instrument (16/26 items rating 10-year change, informant-only); the overview carded here ranks AD8 highest for sensitivity and IQCODE most specific, and that comparator figure prints on its card.

MeSH: Aged · Aged, 80 and over · Aging/psychology · Cognition Disorders/diagnosis,psychology · Dementia/diagnosis,psychology · Female · Humans · Longitudinal Studies · Male · Memory Disorders/diagnosis,psychology · Middle Aged · Neuropsychological Tests/standards · Predictive Value of Tests · Prospective Studies · Cognitive Dysfunction/diagnosis · Dementia/psychology · Early Diagnosis · Primary Health Care/organization & administration · ROC Curve · Sensitivity and Specificity · Surveys and Questionnaires · Correlation of Data · Databases, Factual · Dementia/diagnosis · Health Facilities · Activities of Daily Living · Aging · Diagnostic Tests, Routine · Health Care Sector · Primary Health Care · Reproducibility of Results · Sweden · Systematic Reviews as Topic

Cards (6)

Card 1 — Derivation (Galvin 2005, Neurology — programme-labelled: the Galvin group's own report): at a cut-off of 2 endorsed items the AUC was 0.834 with sensitivity 74% and specificity 86% for very mild dementia (CDR 0.5, prevalence 0.38), rising to 85% sensitivity when 56 participants with mild-to-severe dementia were included

Study: Derivation study — programme-labelled (originators' own report)

Population: A 55-item informant battery was evaluated in informants of 189 longitudinal-study participants against independently obtained Clinical Dementia Rating (CDR); the final 8-item version (memory, orientation, judgement, function) was administered for a further 112 CDR-0 and 68 CDR-0.5 participants, plus 56 with mild-to-severe dementia in the extended analysis.

Summary: Derivation (Galvin 2005, Neurology — programme-labelled: the Galvin group's own report): at a cut-off of 2 endorsed items the AUC was 0.834 with sensitivity 74% and specificity 86% for very mild dementia (CDR 0.5, prevalence 0.38), rising to 85% sensitivity when 56 participants with mild-to-severe dementia were included

Result: At a cut-off of two items endorsed, the area under the curve was 0.834, sensitivity 74% and specificity 86% for very mild dementia (prevalence 0.38); including the 56 participants with mild-to-severe dementia (prevalence 0.53) increased sensitivity to 85%, as published.

Watch out: A derivation in a longitudinal memory-and-aging study sample, not a primary-care screening population; the syntheses on cards 2–5 print beside it.

Source: Galvin JE et al. The AD8: a brief informant interview to detect dementia. Neurology. 2005. PMID: 16116116. Registry ID: none in the record. MeSH: Aged · Aged, 80 and over · Aging/psychology · Cognition Disorders/diagnosis,psychology · Dementia/diagnosis,psychology · Female · Humans · Longitudinal Studies · Male · Memory Disorders/diagnosis,psychology · Middle Aged · Neuropsychological Tests/standards · Predictive Value of Tests · Prospective Studies

Card 2 — Meta-analysis (Chen 2018, Family Practice — systematic review and meta-analysis, 7 studies, 3,728 participants; synthesis, overlapping primary-study sets): pooled sensitivity / specificity pairs were 0.72 / 0.67 and 0.91 / 0.78 across the cognitive-impairment severity subgroups (labelled as published), with summary AUCs of 0.83 and 0.92 and mean administration time under 3 minutes

Study: Systematic review and meta-analysis — synthesis (counted as a synthesis)

Population: Seven studies including 3,728 subjects, classified into two subgroups according to the severity of cognitive impairment; methodological quality assessed with QUADAS-2; English and non-English studies included.

Summary: Meta-analysis (Chen 2018, Family Practice — systematic review and meta-analysis, 7 studies, 3,728 participants; synthesis, overlapping primary-study sets): pooled sensitivity / specificity pairs were 0.72 / 0.67 and 0.91 / 0.78 across the cognitive-impairment severity subgroups (labelled as published), with summary AUCs of 0.83 and 0.92 and mean administration time under 3 minutes

Result: Overall sensitivity (0.72, 0.91) was superior to specificity (0.67, 0.78) across the two severity subgroups; pooled negative likelihood ratios (0.17, 0.13) were better than positive (2.52, 3.94) (labelled as such); summary AUCs were 0.83 and 0.92; meta-regression suggested location (community vs non-community) may source the heterogeneity; average administration time was under 3 minutes, as published.

Watch out: The two pooled pairs belong to different severity subgroups and never merge into a single AD8 accuracy figure.

Source: Chen HH et al. The diagnostic accuracy of the Ascertain Dementia 8 questionnaire for detecting cognitive impairment in primary care in the community, clinics and hospitals: a systematic review and meta-analysis. Family practice. 2018. PMID: 29045636. Registry ID: none in the record. MeSH: Cognitive Dysfunction/diagnosis · Dementia/psychology · Early Diagnosis · Humans · Primary Health Care/organization & administration · ROC Curve · Sensitivity and Specificity · Surveys and Questionnaires

Card 3 — Informant vs participant completion (Tanwani 2023, PLoS ONE — systematic review and meta-analysis; synthesis): informant-completed AD8 pooled at sensitivity 80% / specificity 79% for MCI (7 studies, n = 794) and 91% / 64% for dementia (9 studies, n = 2,393), against participant-completed at 57% / 71% for MCI and 82% / 75% for dementia; recurring high or unclear risk of bias in the index-test and reference-standard domains

Study: Systematic review and meta-analysis by mode of completion — synthesis (counted as a synthesis)

Population: Studies of patients aged ≥60 screened with the AD8 in any healthcare setting at a cut-off of ≥2/8, analysed separately for informant-completed (iAD8) and participant-completed (pAD8) forms against reference standards, with QUADAS-2 risk-of-bias assessment.

Summary: Informant vs participant completion (Tanwani 2023, PLoS ONE — systematic review and meta-analysis; synthesis): informant-completed AD8 pooled at sensitivity 80% / specificity 79% for MCI (7 studies, n = 794) and 91% / 64% for dementia (9 studies, n = 2,393), against participant-completed at 57% / 71% for MCI and 82% / 75% for dementia; recurring high or unclear risk of bias in the index-test and reference-standard domains

Result: iAD8: sensitivity 80% and specificity 79% for MCI (7 studies, n = 794); 91% and 64% for dementia (9 studies, n = 2,393). pAD8: 57% and 71% for MCI (4 studies, n = 836); 82% and 75% for dementia (4 studies, n = 3,015). The authors conclude iAD8 accuracy is superior to pAD8, as published.

Watch out: Who completes the form is part of the measurement — a self-completed AD8 is not the informant instrument the derivation validated.

Source: Tanwani R et al. Diagnostic accuracy of Ascertain Dementia 8-item Questionnaire by participant and informant-A systematic review and meta-analysis. PloS one. 2023. PMID: 37699028. Registry ID: none in the record. MeSH: Aged · Aged, 80 and over · Humans · Middle Aged · Cognitive Dysfunction/diagnosis · Correlation of Data · Databases, Factual · Dementia/diagnosis · Health Facilities

Card 4 — Primary-care contexts (Svensson 2020, Scandinavian Journal of Primary Health Care — systematic review, 5 studies, 13,345 participants; synthesis): sensitivity ranged 88%–100%, specificity 67%–91%, PPV 28%–63% and NPV 96%–100% for symptomatic dementia

Study: Systematic review of diagnostic-accuracy studies in community / primary-care contexts — synthesis (counted as a synthesis)

Population: Five diagnostic-accuracy studies with a total of 13,345 participants, in populations selected within the community or primary care, against internationally approved dementia criteria; QUADAS-2 quality assessment with narrative analysis.

Summary: Primary-care contexts (Svensson 2020, Scandinavian Journal of Primary Health Care — systematic review, 5 studies, 13,345 participants; synthesis): sensitivity ranged 88%–100%, specificity 67%–91%, PPV 28%–63% and NPV 96%–100% for symptomatic dementia

Result: Sensitivity ranged 88%–100%, specificity 67%–91%, positive predictive values 28%–63% and negative predictive values 96%–100%; the review concludes the AD8 identifies true positives and predicts low-risk dementia well — better at identifying people at risk of not having dementia than at confirming those who do, as published.

Watch out: PPV of 28%–63% in these spectra means most positive screens in primary care are not dementia — the range prints, not a pooled point.

Source: Svensson A et al. Performance of the Eight-item Informant Interview to Differentiate Aging and Dementia within a context similar to the Swedish primary healthcare sector: a systematic review of diagnostic test accuracy studies. Scandinavian journal of primary health care. 2020. PMID: 33216659. Registry ID: none in the record. MeSH: Activities of Daily Living · Aged · Aged, 80 and over · Aging · Dementia/diagnosis · Diagnostic Tests, Routine · Female · Health Care Sector · Humans · Male · Primary Health Care · Reproducibility of Results · Sensitivity and Specificity · Surveys and Questionnaires · Sweden

Card 5 — Overview of reviews (Taylor-Rowan 2023, Psychological Medicine — overview of 25 systematic reviews, 93 studies, 13 tools; synthesis): in the pooled analysis (37 studies, 11,052 participants) the AD8 ranked highest for sensitivity (90%, 95% credible interval 82 to 95) while the IQCODE was most specific (81%, 66 to 90) — with overall certainty graded low

Study: Overview of systematic reviews — synthesis (counted as a synthesis)

Population: 25 systematic reviews of informant-based questionnaires for cognitive impairment or dementia, pooled with network approaches across 13 tools; certainty evaluated with GRADE; most studies were in secondary-care settings, and only AD8 and IQCODE have been extensively evaluated.

Summary: Overview of reviews (Taylor-Rowan 2023, Psychological Medicine — overview of 25 systematic reviews, 93 studies, 13 tools; synthesis): in the pooled analysis (37 studies, 11,052 participants) the AD8 ranked highest for sensitivity (90%, 95% credible interval 82 to 95) while the IQCODE was most specific (81%, 66 to 90) — with overall certainty graded low

Result: The AD8 ranked highest for sensitivity (90%; 95% credible interval 82 to 95; best-test probability 36%) and the IQCODE most specific (81%; 66 to 90; best-test probability 29%). GRADE certainty was low overall, as published.

Watch out: The IQCODE figure on this card is the comparator limb; the IQCODE's own shelf is #7921 and the two rows cross-point. Low overall certainty prints beside the ranking.

Source: Taylor-Rowan M et al. Informant-based screening tools for dementia: an overview of systematic reviews. Psychological medicine. 2023. PMID: 34030753. Registry ID: none in the record. MeSH: Humans · Aged · Dementia/diagnosis,psychology · Systematic Reviews as Topic · Sensitivity and Specificity · Cognitive Dysfunction/diagnosis · Surveys and Questionnaires

Card 6 — Synthesis: across one derivation and four overlapping syntheses, the AD8 is a sensitive, informant-dependent screen — 91% pooled sensitivity for dementia when an informant completes it, 57% for MCI when the participant does — with low overall certainty in the overview and primary-care PPVs of only 28%–63%

Study: Synthesis

Population: All reports carded on this shelf: Galvin 2005 (derivation), Chen 2018, Tanwani 2023, Svensson 2020 and Taylor-Rowan 2023 (four syntheses with overlapping primary-study sets).

Summary: Synthesis: across one derivation and four overlapping syntheses, the AD8 is a sensitive, informant-dependent screen — 91% pooled sensitivity for dementia when an informant completes it, 57% for MCI when the participant does — with low overall certainty in the overview and primary-care PPVs of only 28%–63%

Result: This is a screening-accuracy shelf, not a treatment shelf. The four syntheses are counted as syntheses, never as independent confirmations.

Watch out: See the individual cards for each report's limits; this synthesis adds no new data.

Source: Synthesis of the reports carded above; no additional source.