SourceMed · Shelf #7965 in the ask interface
Fugl-Meyer reliability: high item agreement early after stroke and Danish ICC 0.95 — on tolerance-based ordinal statistics, with a ceiling effect
Shelf #7965 · Brain, stroke & mind
MEASUREMENT RELIABILITY: item-level agreement 79%–100% (upper) and ≥75% (lower) early after stroke, total-score agreement only at stated point tolerances (13 points upper; 1–2 points lower), Danish upper-extremity inter-tester ICC 0.95 with MCID ≥4 points, and a documented ceiling effect; a reliability stamp, not a treatment stamp
Stamped: 2026-11-28.
Evidence published: 2002–2021.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
How reliable is the Fugl-Meyer Assessment (sensorimotor examination scored on 3-point ordinal items; 100-point motor domain, with upper-extremity and lower-extremity subscales) between and within raters early after stroke — what did the critical review conclude about the motor domain's reliability, validity and ceiling effect, what item- and total-level agreement did the two 60-patient early-subacute reliability studies find for the upper and lower extremities, and what inter-tester ICC and minimal clinically important difference did the Danish upper-extremity version establish?
Balance of the evidence
The agreement statistics here are ordinal-scale statistics — percentage agreement at stated point-tolerances and rank-based methods — and no card converts them into a single ICC for the whole instrument; the one ICC printed (0.95) belongs to the Danish upper-extremity total score in 50 inpatients. The two 60-patient studies come from the same research programme and population frame (early subacute stroke, mean age 65.9) and print as such, not as two independent spectra. Subscale prints with every figure (upper vs lower extremity are different item sets), and the 2002 review's ceiling-effect warning prints — reliability at the top of the scale is not what these studies measured. This is a measurement-reliability shelf, not a treatment shelf. Cross-point: modified Rankin Scale reliability #7931 — a global outcome grade, against this sensorimotor impairment examination.
MeSH: Disability Evaluation · Humans · Motor Skills · Outcome Assessment, Health Care · Postural Balance/physiology · Reproducibility of Results · Stroke/physiopathology · Stroke Rehabilitation · Aged · Female · Male · Stroke/complications · Stroke Rehabilitation/methods · Upper Extremity/innervation · Lower Extremity · Physical Therapists · Stroke · Upper Extremity · Denmark · Psychometrics · Recovery of Function · Translations
Cards (5)
Card 1 — Critical review (Gladstone 2002, Neurorehabilitation and Neural Repair — labelled a review; its conclusions are qualitative and no coefficient is printed from it): the 100-point motor domain showed excellent interrater and intrarater reliability and construct validity with preliminary responsiveness evidence, limited by a ceiling effect, omission of some relevant items and heavier weighting of the arm than the leg; criterion validity and minimal clinically important difference were undefined at that date
Study: Critical review of measurement properties — qualitative (no coefficient printed)
Population: The Fugl-Meyer scale — the first quantitative evaluative instrument for sensorimotor stroke recovery, based on Twitchell and Brunnstrom's sequential stages of motor return — as evaluated across the stroke population literature to 2002.
Summary: Critical review (Gladstone 2002, Neurorehabilitation and Neural Repair — labelled a review; its conclusions are qualitative and no coefficient is printed from it): the 100-point motor domain showed excellent interrater and intrarater reliability and construct validity with preliminary responsiveness evidence, limited by a ceiling effect, omission of some relevant items and heavier weighting of the arm than the leg; criterion validity and minimal clinically important difference were undefined at that date
Result: The review concludes the motor domain is a well-designed, feasible and efficient examination with excellent interrater and intrarater reliability and construct validity and preliminary evidence of responsiveness, and recommends it highly as a clinical and research tool; it calls for further study of criterion validity, sensitivity to change and minimal clinically important difference in specific subgroups, as published.
Watch out: A 2002 qualitative verdict, not a pooled coefficient; its ceiling-effect warning frames every later card — agreement near the top of the scale is not what the primary studies measured.
Source: Gladstone DJ et al. The fugl-meyer assessment of motor recovery after stroke: a critical review of its measurement properties. Neurorehabilitation and neural repair. 2002. PMID: 12234086. Registry ID: none in the record. MeSH: Disability Evaluation · Humans · Motor Skills · Outcome Assessment, Health Care · Postural Balance/physiology · Reproducibility of Results · Stroke/physiopathology · Stroke Rehabilitation
Card 2 — Upper extremity (Hernández 2019, Journal of Rehabilitation Medicine — 60 patients with early subacute stroke, mean age 65.9, scored by two physiotherapists independently on consecutive days within 10 days of stroke): item-level intra- and inter-rater agreement was high (79%–100%), with systematic disagreement in 4 shoulder-section items, and 70% agreement at subscale / total level when a 13-point difference was accepted
Study: Primary reliability study — upper extremity, early subacute stroke
Population: 60 consecutively included stroke patients (mean age 65.9 years) admitted to the Central Military Hospital of Colombia, Bogota; two physiotherapists scored the upper-extremity assessment independently on 2 consecutive days within 10 days post stroke, analysed with a rank-based method for paired ordinal data.
Summary: Upper extremity (Hernández 2019, Journal of Rehabilitation Medicine — 60 patients with early subacute stroke, mean age 65.9, scored by two physiotherapists independently on consecutive days within 10 days of stroke): item-level intra- and inter-rater agreement was high (79%–100%), with systematic disagreement in 4 shoulder-section items, and 70% agreement at subscale / total level when a 13-point difference was accepted
Result: Systematic disagreements in position or concentration were detected in 4 shoulder-section items; item-level intra- and inter-rater agreement was high (79%–100%); 70% agreement was reached for subscales and total score when a 13-point difference was accepted, as published.
Watch out: The 13-point tolerance behind the total-score agreement figure prints with it — agreement at zero tolerance is not what this study reports. Same programme and population frame as card 3.
Source: Hernández ED et al. Intra- and inter-rater reliability of Fugl-Meyer Assessment of Upper Extremity in stroke. Journal of rehabilitation medicine. 2019. PMID: 31448807. Registry ID: none in the record. MeSH: Aged · Female · Humans · Male · Reproducibility of Results · Stroke/complications · Stroke Rehabilitation/methods · Upper Extremity/innervation
Card 3 — Lower extremity (Hernández 2021, Brazilian Journal of Physical Therapy — 60 patients, mean age 65.9, scored by three trained physiotherapists in random pairs on two consecutive days, 4–9 days post stroke): item-level percentage agreement was ≥75%, and summed-score intrarater reliability reached the ≥70% agreement threshold when a 1- or 2-point difference was accepted
Study: Primary reliability study — lower extremity, early after stroke
Population: 60 stroke patients (mean age 65.9 years; median lower-extremity score 29 points) scored simultaneously but independently by three experienced, trained physical therapists randomly assigned in pairs, on two consecutive days between 4 and 9 days post stroke, analysed with a rank-based ordinal method.
Summary: Lower extremity (Hernández 2021, Brazilian Journal of Physical Therapy — 60 patients, mean age 65.9, scored by three trained physiotherapists in random pairs on two consecutive days, 4–9 days post stroke): item-level percentage agreement was ≥75%, and summed-score intrarater reliability reached the ≥70% agreement threshold when a 1- or 2-point difference was accepted
Result: Item-level reliability was high (percentage agreement ≥75%); two items (ankle dorsiflexion during flexor synergy, normal reflex activity) showed some systematic intrarater disagreement; satisfactory intrarater reliability (agreement ≥70%) was reached for all summed scores when a 1- or 2-point difference was accepted, as published.
Watch out: Same research programme and population frame as card 2 (early subacute, mean age 65.9) — the two studies are not independent spectra.
Source: Hernández ED et al. Intra- and inter-rater reliability of Fugl-Meyer Assessment of Lower Extremity early after stroke. Brazilian journal of physical therapy. 2021. PMID: 33358073. Registry ID: none in the record. MeSH: Aged · Humans · Lower Extremity · Physical Therapists · Reproducibility of Results · Stroke · Stroke Rehabilitation · Upper Extremity
Card 4 — Danish upper-extremity version (Lundquist 2017, Disability and Rehabilitation — 50 acute-to-subacute inpatients): inter-tester ICC 0.95, responsiveness AUC 0.87 (sensitivity 77% / specificity 89% for improvement), minimal clinically important difference ≥4 points, and concurrent validity against the Motor Assessment Scale r = 0.94–0.95
Study: Primary reliability / responsiveness study — Danish translation, upper extremity
Population: 50 inpatients aged >18 in the acute-to-subacute stage of stroke at Skive Neurorehabilitation, Denmark (May 2014–February 2015); each patient tested by two examiners; responsiveness by ROC analysis of change scores; concurrent validity against the Motor Assessment Scale by Spearman correlation.
Summary: Danish upper-extremity version (Lundquist 2017, Disability and Rehabilitation — 50 acute-to-subacute inpatients): inter-tester ICC 0.95, responsiveness AUC 0.87 (sensitivity 77% / specificity 89% for improvement), minimal clinically important difference ≥4 points, and concurrent validity against the Motor Assessment Scale r = 0.94–0.95
Result: Inter-tester ICC was 0.95; AUC 0.87 with sensitivity 77% and specificity 89% for correctly determining improvement; minimal clinically important difference ≥4 points; concurrent validity r = 0.94–0.95, as published.
Watch out: The ICC of 0.95 belongs to this Danish upper-extremity total score in 50 inpatients — it is not an ICC for the whole Fugl-Meyer instrument.
Source: Lundquist CB et al. The Fugl-Meyer assessment of the upper extremity: reliability, responsiveness and validity of the Danish version. Disability and rehabilitation. 2017. PMID: 27062881. Registry ID: none in the record. MeSH: Aged · Denmark · Disability Evaluation · Female · Humans · Male · Psychometrics · Recovery of Function · Reproducibility of Results · Stroke Rehabilitation · Translations · Upper Extremity
Card 5 — Synthesis: the Fugl-Meyer motor domain is highly reliable between and within raters early after stroke on ordinal agreement measures (item agreement 75%–100%; Danish upper-extremity ICC 0.95, MCID ≥4 points), with a documented ceiling effect — but its agreement figures are tolerance-based percentages, not a single instrument-wide coefficient
Study: Synthesis
Population: All reports carded on this shelf: Gladstone 2002 (critical review), Hernández 2019, Hernández 2021 and Lundquist 2017.
Summary: Synthesis: the Fugl-Meyer motor domain is highly reliable between and within raters early after stroke on ordinal agreement measures (item agreement 75%–100%; Danish upper-extremity ICC 0.95, MCID ≥4 points), with a documented ceiling effect — but its agreement figures are tolerance-based percentages, not a single instrument-wide coefficient
Result: This is a measurement-reliability shelf, not a treatment shelf. Cross-point: modified Rankin Scale reliability #7931.
Watch out: See the individual cards for each report's limits; this synthesis adds no new data.
Source: Synthesis of the reports carded above; no additional source.