SourceMed · Shelf #7967 in the ask interface

Insomnia Severity Index: pooled 88% / 85% — but the cut-off migrates from ≥8 in cancer survivors to ≥11–14 in psychiatric outpatients

Shelf #7967 · Lungs, breathing & sleep

PREDICTIVE PERFORMANCE: ISI pooled sensitivity 88% / specificity 85% (specificity interval 0.68 to 0.94) in the three-tool meta-analysis, with usable cut-offs migrating from ≥8 (cancer survivors, SCID-5) to ≥11–14 (psychiatric outpatients, DSM-5 / ICD-10); PSQI carded only as the synthesis's limb (94% / 76%); a screening-accuracy stamp, not a treatment stamp

Stamped: 2026-11-28.

Evidence published: 2016–2021.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

How accurately do the Insomnia Severity Index (ISI, 7 items, 0–28) and its fellow self-report sleep questionnaires detect insomnia disorder against interview or diagnostic standards — what pooled sensitivity and specificity does the three-tool meta-analysis give the ISI, the Athens Insomnia Scale and the Pittsburgh Sleep Quality Index, what cut-off did the ISI need in young adult cancer survivors against the SCID-5, and how did the ISI compare with five other sleep scales in psychiatric outpatients against ICD-10 and DSM-5 criteria?

Balance of the evidence

The cut-off is the content of this shelf and it migrates by population — ≥8 in young adult cancer survivors against the SCID-5, ≥11 (DSM-5) to ≥14 (ICD-10) in psychiatric outpatients — and no figure prints without its population and reference standard. The meta-analysis's specificity intervals are wide (ISI 0.68 to 0.94) and print. The Pittsburgh Sleep Quality Index is carded ONLY as a stated limb of the three-tool meta-analysis on card 1 (pooled sensitivity 94% / specificity 76% for insomnia screening), never as a separate shelf, and its pooled pair describes insomnia screening, not sleep-quality grading. This is a screening-accuracy shelf, not a treatment shelf.

MeSH: Adult · Asian People/psychology · Case-Control Studies · Cross-Sectional Studies · Female · Humans · Male · Prevalence · Sensitivity and Specificity · Sleep Initiation and Maintenance Disorders/diagnosis,psychology · Cancer Survivors · Diagnostic and Statistical Manual of Mental Disorders · Mass Screening · Neoplasms · Sleep Initiation and Maintenance Disorders/diagnosis · Young Adult · Comorbidity · International Classification of Diseases · Mental Disorders/therapy · Self Report · Sleep Initiation and Maintenance Disorders/classification,diagnosis,epidemiology · Surveys and Questionnaires

Cards (4)

Card 1 — Three-tool meta-analysis (Chiu 2016, Journal of Psychosomatic Research — 19 studies, 4,693 participants; synthesis): pooled sensitivity / specificity were 88% (0.79 to 0.93) / 85% (0.68 to 0.94) for the ISI, 91% (0.87 to 0.93) / 87% (0.68 to 0.95) for the Athens Insomnia Scale and 94% (0.86 to 0.98) / 76% (0.64 to 0.85) for the PSQI, with diagnostic odds ratios (labelled as such) of 41.93, 67.7 and 53 and no significant difference among the three tools

Study: Meta-analysis of diagnostic accuracy — three-tool synthesis (PSQI as stated limb only)

Population: 19 studies comprising 4,693 adult participants assessing the ISI, Athens Insomnia Scale or Pittsburgh Sleep Quality Index against a reference standard for insomnia (searches to May 20, 2015). The PSQI is carded here only as this synthesis's stated limb, per the row's ruling — there is no separate PSQI shelf.

Summary: Three-tool meta-analysis (Chiu 2016, Journal of Psychosomatic Research — 19 studies, 4,693 participants; synthesis): pooled sensitivity / specificity were 88% (0.79 to 0.93) / 85% (0.68 to 0.94) for the ISI, 91% (0.87 to 0.93) / 87% (0.68 to 0.95) for the Athens Insomnia Scale and 94% (0.86 to 0.98) / 76% (0.64 to 0.85) for the PSQI, with diagnostic odds ratios (labelled as such) of 41.93, 67.7 and 53 and no significant difference among the three tools

Result: Pooled sensitivity was 88% (95% CI 0.79 to 0.93) for the ISI, 91% (0.87 to 0.93) for the AIS and 94% (0.86 to 0.98) for the PSQI; pooled specificity was 85% (0.68 to 0.94), 87% (0.68 to 0.95) and 76% (0.64 to 0.85); pooled diagnostic odds ratios (labelled as such) were 41.93 (8.77 to 200.33), 67.7 (23.4 to 196.1) and 53 (15.5 to 186.2). Summary estimates did not differ significantly among the three tools, as published. (Journal as printed in the record fetched at build: Journal of Psychosomatic Research — the slate file's 'Sleep Medicine Reviews' is corrected by the record.)

Watch out: The specificity intervals are wide (ISI 0.68 to 0.94) and the diagnostic odds ratio intervals span an order of magnitude — pooled points never print without them.

Source: Chiu HY et al. A meta-analysis of diagnostic accuracy of three screening tools for insomnia. Journal of psychosomatic research. 2016. PMID: 27411756. Registry ID: none in the record. MeSH: Adult · Asian People/psychology · Case-Control Studies · Cross-Sectional Studies · Female · Humans · Male · Prevalence · Sensitivity and Specificity · Sleep Initiation and Maintenance Disorders/diagnosis,psychology

Card 2 — Young adult cancer survivors (Michaud 2021, Sleep Medicine — 250 survivors, 52 with SCID-5 insomnia disorder): AUC 0.91; a cut-off of ≥8 met the study's screening criteria (sensitivity 0.85, specificity 0.77), ≥7 gave 0.96 / 0.70, and cut-offs of ≥12–14 were recommended where overall accuracy is prioritised; the authors warn cut-offs derived in one population do not generalise

Study: Primary validation — young adult cancer survivors vs SCID-5

Population: 250 young adult cancer survivors completing the ISI and the SCID-5 insomnia module; 52 met criteria for SCID-5 insomnia disorder; a cut-off with sensitivity ≥0.85 and specificity ≥0.75 was deemed acceptable for screening.

Summary: Young adult cancer survivors (Michaud 2021, Sleep Medicine — 250 survivors, 52 with SCID-5 insomnia disorder): AUC 0.91; a cut-off of ≥8 met the study's screening criteria (sensitivity 0.85, specificity 0.77), ≥7 gave 0.96 / 0.70, and cut-offs of ≥12–14 were recommended where overall accuracy is prioritised; the authors warn cut-offs derived in one population do not generalise

Result: The ISI had excellent discrimination (AUC 0.91). A cut-off of ≥8 met the screening criteria (sensitivity 0.85, specificity 0.77); ≥7 gave higher sensitivity (0.96) but lower specificity (0.70); cut-offs ≥12 and ≥14 were recommended for applications prioritising overall accuracy. The authors state cut-off scores derived from different populations are not generalizable, as published. (Journal as printed in the record fetched at build: Sleep Medicine — the slate file's 'Journal of Clinical Sleep Medicine' is corrected by the record.)

Watch out: A survivor-population cut-off: ≥8 here against ≥11–14 in the psychiatric outpatients on card 3 — the migration is the finding.

Source: Michaud AL et al. Validation of the Insomnia Severity Index (ISI) for identifying insomnia in young adult cancer survivors: comparison with a structured clinical diagnostic interview of the DSM-5 (SCID-5). Sleep medicine. 2021. PMID: 33640841. Registry ID: none in the record. MeSH: Cancer Survivors · Diagnostic and Statistical Manual of Mental Disorders · Humans · Mass Screening · Neoplasms · Sleep Initiation and Maintenance Disorders/diagnosis · Young Adult

Card 3 — Psychiatric outpatients (Seow 2018, Sleep Medicine — 400 outpatients completing six sleep scales against interview-established ICD-10 and DSM-5 insomnia): the ISI was the most accurate of the six (AUC 0.88 (0.84 to 0.92) for ICD-10 and 0.82 (0.78 to 0.86) for DSM-5), with optimal cut-offs of ≥14 (ICD-10) and ≥11 (DSM-5) in this population

Study: Primary validation — psychiatric outpatients, six-scale comparison

Population: 400 psychiatric outpatients completing the PSQI, ISI, Epworth Sleepiness Scale, Flinders Fatigue Scale, Functional Outcomes of Sleep Questionnaire and Dysfunctional Beliefs and Attitudes about Sleep Scale, against insomnia status established with the interviewer-administered Brief Insomnia Questionnaire. (Journal as printed in the record fetched at build: Sleep Medicine — the slate file's 'Journal of Psychosomatic Research' is corrected by the record.)

Summary: Psychiatric outpatients (Seow 2018, Sleep Medicine — 400 outpatients completing six sleep scales against interview-established ICD-10 and DSM-5 insomnia): the ISI was the most accurate of the six (AUC 0.88 (0.84 to 0.92) for ICD-10 and 0.82 (0.78 to 0.86) for DSM-5), with optimal cut-offs of ≥14 (ICD-10) and ≥11 (DSM-5) in this population

Result: ROC analysis showed the ISI to be the most accurate of the six measures on both criteria — AUC 0.88 (95% CI 0.84 to 0.92) for ICD-10 and 0.82 (0.78 to 0.86) for DSM-5, both graded 'good' accuracy — with cut-off scores of ≥14 and ≥11 providing optimal sensitivity and specificity for ICD-10 and DSM-5 detection respectively, as published.

Watch out: The optimal cut-off differs by the diagnostic system used within the same cohort (≥14 ICD-10 vs ≥11 DSM-5) — reference standard prints with every figure.

Source: Seow LSE et al. Identifying the best sleep measure to screen clinical insomnia in a psychiatric population. Sleep medicine. 2018. PMID: 29425582. Registry ID: none in the record. MeSH: Adult · Comorbidity · Cross-Sectional Studies · Diagnostic and Statistical Manual of Mental Disorders · Female · Humans · International Classification of Diseases · Male · Mass Screening · Mental Disorders/therapy · Prevalence · Self Report · Sensitivity and Specificity · Sleep Initiation and Maintenance Disorders/classification,diagnosis,epidemiology · Surveys and Questionnaires

Card 4 — Synthesis: the ISI screens for insomnia with pooled sensitivity 88% / specificity 85% in the three-tool meta-analysis — statistically indistinguishable from the AIS and the PSQI limb — but its usable cut-off migrates from ≥8 in cancer survivors to ≥11–14 in psychiatric outpatients, so no ISI figure is meaningful without its population and reference standard

Study: Synthesis

Population: All reports carded on this shelf: Chiu 2016 (three-tool synthesis), Michaud 2021 and Seow 2018.

Summary: Synthesis: the ISI screens for insomnia with pooled sensitivity 88% / specificity 85% in the three-tool meta-analysis — statistically indistinguishable from the AIS and the PSQI limb — but its usable cut-off migrates from ≥8 in cancer survivors to ≥11–14 in psychiatric outpatients, so no ISI figure is meaningful without its population and reference standard

Result: This is a screening-accuracy shelf, not a treatment shelf. The PSQI appears only as the synthesis's stated limb on card 1, never as a separate shelf.

Watch out: See the individual cards for each report's limits; this synthesis adds no new data.

Source: Synthesis of the reports carded above; no additional source.