SourceMed · Shelf #7969 in the ask interface

Ankle ligament tests: palpation sensitive but unspecific, drawer specific but timing-dependent — 21% sensitive acutely, 61% at a week

Shelf #7969 · Bones & joints

PREDICTIVE PERFORMANCE: no test exceeds 90% on both measures; ATFL palpation sensitivity 95%–100% with specificity 0%–32%, pooled anterior drawer 54% / 87%, and drawer sensitivity 21% acutely vs 61% at 5–8 days in the same cohort — timing is part of the measurement; a diagnostic-accuracy stamp, not a management stamp

Stamped: 2026-11-28.

Evidence published: 2015–2024.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

After lateral ankle sprain, how accurately do the bedside clinical tests — anterior talofibular and calcaneofibular ligament palpation, the anterior drawer test, talar tilt and their clusters — identify ligament injury against imaging or surgery: what sensitivity and specificity ranges does the systematic review and meta-analysis report for palpation and for the pooled anterior drawer test, how much does delaying examination from the acute (0–2 day) to the delayed (5–8 day) setting change the accuracy of the drawer test and of haematoma, and how did the clinical anterior drawer test compare with stress sonography and an arthrometer against high-resolution ultrasound?

Balance of the evidence

Timing is part of the measurement on this shelf: in the same cohort the anterior drawer test's sensitivity was 21% acutely (0–2 days) and 61% at 5–8 days, and no figure prints without its post-injury timing. The meta-analysis's palpation ranges span nearly the whole scale across studies (ATFL palpation specificity 0%–32%) and print as ranges, not points. Reference standards differ (MRI complete discontinuity vs high-resolution sonographic rupture vs imaging / surgical composites) and the target differs (any injury vs complete discontinuity) — both print. The smallest study's N (30 patients) prints on its card's face. This is a diagnostic-accuracy shelf, not a management shelf.

MeSH: Ankle Injuries/diagnosis · Ankle Joint · Humans · Lateral Ligament, Ankle/injuries · Ligaments, Articular/injuries · Subtalar Joint · Adult · Ankle · Hematoma · Ankle/diagnostic imaging · Ankle Injuries/diagnostic imaging · Ankle Joint/diagnostic imaging · Arthrometry, Articular · Exercise Test · Female · Joint Instability/diagnosis · Lateral Ligament, Ankle/diagnostic imaging,injuries · Male · Middle Aged · Reproducibility of Results · Rupture · Sensitivity and Specificity · Sprains and Strains/diagnosis · Ultrasonography · Young Adult

Cards (4)

Card 1 — Systematic review and meta-analysis (Netterström-Wedin 2022, Sports Health — 14 studies, 6,302 observations, 9 clinical tests, high-bias / applicability-concern studies excluded from pooling; synthesis): no test exceeded 90% on both sensitivity and specificity; ATFL palpation was highly sensitive (95%–100%) but poorly specific (0%–32%), CFL palpation 49%–100% / 26%–79%, and the pooled anterior drawer test (6 studies, 885 observations) had sensitivity 54% (35 to 71) and specificity 87% (63 to 96)

Study: Systematic review and meta-analysis — synthesis (counted as a synthesis)

Population: Diagnostic studies comparing clinical examination (palpation, joint laxity tests) of the talocrural and subtalar joint ligaments after ankle sprain against imaging or surgery (inception to November 18, 2020); quality assessed with QUADAS-2.

Summary: Systematic review and meta-analysis (Netterström-Wedin 2022, Sports Health — 14 studies, 6,302 observations, 9 clinical tests, high-bias / applicability-concern studies excluded from pooling; synthesis): no test exceeded 90% on both sensitivity and specificity; ATFL palpation was highly sensitive (95%–100%) but poorly specific (0%–32%), CFL palpation 49%–100% / 26%–79%, and the pooled anterior drawer test (6 studies, 885 observations) had sensitivity 54% (35 to 71) and specificity 87% (63 to 96)

Result: No test had both sensitivity and specificity exceeding 90%. Palpation of the anterior talofibular ligament was highly sensitive (95%–100%) but poorly specific (0%–32%) (min–max, n = 6 studies); calcaneofibular ligament palpation ranged 49%–100% / 26%–79% (n = 6). Pooled anterior drawer test (6 studies, 885 observations): sensitivity 54% (95% CI 35% to 71%), specificity 87% (63% to 96%). The authors conclude the ATFL is best assessed with a cluster of palpation (rule out) and anterior drawer testing (rule in), that the talar tilt test can rule in CFL injury, and that generalisability is limited by insufficient blinding reporting and poor study quality, as published.

Watch out: The palpation figures are min–max ranges across studies spanning nearly the whole scale — they print as ranges, never as pooled points.

Source: Netterström-Wedin F et al. Diagnostic Accuracy of Clinical Tests Assessing Ligamentous Injury of the Talocrural and Subtalar Joints: A Systematic Review With Meta-Analysis. Sports health. 2022. PMID: 34286639. Registry ID: PROSPERO CRD42020187848 (registration as printed in the record). MeSH: Ankle Injuries/diagnosis · Ankle Joint · Humans · Lateral Ligament, Ankle/injuries · Ligaments, Articular/injuries · Subtalar Joint

Card 2 — Acute vs delayed examination (Baltes 2024, Knee Surgery, Sports Traumatology, Arthroscopy — prospective study of 43 acute ankle injuries in adult athletes, 23 (53%) with complete lateral-ligament discontinuity on 3T MRI): acutely, lateral swelling had 100% sensitivity (82 to 100) and the anterior drawer test 100% specificity (77 to 100) but only 21% sensitivity (7 to 46), which rose to 61% (39 to 80) in the delayed (5–8 day) setting, while haematoma sensitivity rose from 43% to 91%; clinical suspicion's positive likelihood ratio (labelled as such) was 4.35 acutely and 6.09 delayed

Study: Prospective paired accuracy study — acute vs delayed settings, MRI reference

Population: 43 acute ankle injuries in adult athletes (≥18 years) assessed within 2 days of injury and again at 5–8 days, from 117 injuries screened; fractures and cases without timely 3T MRI were excluded; MRI was the reference standard for complete discontinuity of the lateral ligaments.

Summary: Acute vs delayed examination (Baltes 2024, Knee Surgery, Sports Traumatology, Arthroscopy — prospective study of 43 acute ankle injuries in adult athletes, 23 (53%) with complete lateral-ligament discontinuity on 3T MRI): acutely, lateral swelling had 100% sensitivity (82 to 100) and the anterior drawer test 100% specificity (77 to 100) but only 21% sensitivity (7 to 46), which rose to 61% (39 to 80) in the delayed (5–8 day) setting, while haematoma sensitivity rose from 43% to 91%; clinical suspicion's positive likelihood ratio (labelled as such) was 4.35 acutely and 6.09 delayed

Result: In the acute setting lateral swelling had 100% sensitivity (95% CI 82 to 100), haematoma 85% specificity (61 to 96) and the anterior drawer test 100% specificity (77 to 100) with 21% sensitivity (7 to 46). In the delayed setting, haematoma sensitivity improved from 43% (24 to 65) to 91% (70 to 98; p<0.01) and anterior drawer sensitivity from 21% (7 to 46) to 61% (39 to 80; p=0.02). Clinical suspicion's positive likelihood ratio (labelled as such) was 4.35 (0.55 to 34.17) acutely and 6.09 (1.57 to 23.60) delayed, as published.

Watch out: The target is complete discontinuity, not any ligament injury; the same test at two timings is two different measurements — timing prints with every figure. N = 43 prints on the face.

Source: Baltes TPA et al. Acute clinical evaluation for the diagnosis of lateral ankle ligament injuries is useful: A comparison between the acute and delayed settings. Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA. 2024. PMID: 38385771. Registry ID: none in the record. MeSH: Adult · Humans · Ankle · Lateral Ligament, Ankle/injuries · Ankle Joint · Ankle Injuries/diagnosis · Hematoma

Card 3 — Clinical test vs devices (Wiebking 2015, Foot and Ankle Surgery — 30 patients, 15 with ligament rupture and 15 with sprain, against high-resolution sonography; small N prints on the face): the clinical anterior drawer examination achieved sensitivity 0.93 and specificity 0.67, against stress sonography at 0.27 / 0.87 (3 mm cut-off) and the arthrometer at 0.8 / 0.4 (3.95 mm cut-off)

Study: Primary accuracy study — small N (30 patients), sonographic reference standard

Population: 30 patients (mean age 35 ± 14 years) with lateral ligament lesion of the ankle involving the anterior talofibular ligament — 15 with ligamentous rupture and 15 with ankle sprain; high-resolution sonography was the gold standard.

Summary: Clinical test vs devices (Wiebking 2015, Foot and Ankle Surgery — 30 patients, 15 with ligament rupture and 15 with sprain, against high-resolution sonography; small N prints on the face): the clinical anterior drawer examination achieved sensitivity 0.93 and specificity 0.67, against stress sonography at 0.27 / 0.87 (3 mm cut-off) and the arthrometer at 0.8 / 0.4 (3.95 mm cut-off)

Result: Stress sonography (Hoffmann method, 3 mm cut-off) had sensitivity 0.27 and specificity 0.87; the arthrometer (3.95 mm cut-off) 0.8 and 0.4; the clinical anterior drawer investigation 0.93 and 0.67. The authors conclude clinical examination under adequate analgesia seems to remain the most reliable tool, while calling for studies with higher case numbers, as published. (Journal as printed in the record fetched at build: Foot and Ankle Surgery — the slate file's 'BMC Musculoskeletal Disorders' is corrected by the record.)

Watch out: N = 30 with a 15 / 15 rupture / sprain spectrum — an enriched case mix that flatters sensitivity; the authors' own call for larger studies prints with the figures.

Source: Wiebking U et al. An accuracy evaluation of clinical, arthrometric, and stress-sonographic acute ankle instability examinations. Foot and ankle surgery : official journal of the European Society of Foot and Ankle Surgeons. 2015. PMID: 25682406. Registry ID: none in the record. MeSH: Adult · Ankle/diagnostic imaging · Ankle Injuries/diagnostic imaging · Ankle Joint/diagnostic imaging · Arthrometry, Articular · Exercise Test · Female · Humans · Joint Instability/diagnosis · Lateral Ligament, Ankle/diagnostic imaging,injuries · Ligaments, Articular/injuries · Male · Middle Aged · Reproducibility of Results · Rupture · Sensitivity and Specificity · Sprains and Strains/diagnosis · Ultrasonography · Young Adult

Card 4 — Synthesis: no bedside ankle test is both sensitive and specific — ATFL palpation rules out (sensitivity 95%–100%, specificity 0%–32%), the anterior drawer rules in (pooled specificity 87%) but its sensitivity is timing-dependent (21% acutely, 61% at a week, 0.93 in one 30-patient sonography-referenced study) — so the examination's accuracy is a property of test, timing and target together

Study: Synthesis

Population: All reports carded on this shelf: Netterström-Wedin 2022 (synthesis), Baltes 2024 and Wiebking 2015.

Summary: Synthesis: no bedside ankle test is both sensitive and specific — ATFL palpation rules out (sensitivity 95%–100%, specificity 0%–32%), the anterior drawer rules in (pooled specificity 87%) but its sensitivity is timing-dependent (21% acutely, 61% at a week, 0.93 in one 30-patient sonography-referenced study) — so the examination's accuracy is a property of test, timing and target together

Result: This is a diagnostic-accuracy shelf, not a management shelf.

Watch out: See the individual cards for each report's limits; this synthesis adds no new data.

Source: Synthesis of the reports carded above; no additional source.