SourceMed · Shelf #7971 in the ask interface
Pulsus paradoxus for cardiac tamponade: 79% sensitive and only 40% specific in a 21-patient prospective study, present in under half of post-cardiac-surgery tamponade — its absence does not exclude tamponade
Shelf #7971 · Heart, vessels, blood pressure & clotting
PREDICTIVE PERFORMANCE — limited for the classic sign: pulsus paradoxus 79% sensitive / 40% specific in N=21 prospective patients and present in only 48% of N=29 post-surgical tamponade cases; oximetry paradoxus AUC 0.90 in N=74; a diagnostic-accuracy stamp, not a treatment stamp
Stamped: 2026-11-28.
Evidence published: 1986–2019.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients with pericardial effusion, how accurately does pulsus paradoxus (an inspiratory systolic-pressure fall >10 mmHg) identify cardiac tamponade against haemodynamic / echocardiographic standards — what sensitivity and specificity did the prospective 21-patient study find for pulsus paradoxus vs right-ventricular diastolic collapse, how often was pulsus paradoxus present in post-cardiac-surgery tamponade where effusions were mostly localised, and how accurately does the pulse-oximetry waveform version (oximetry paradoxus) perform against the sphygmomanometer measurement? (diagnostic-accuracy question.)
Balance of the evidence
This is a diagnostic-accuracy shelf whose finding is largely negative for the classic sign: pulsus paradoxus was 79% sensitive and only 40% specific in the prospective 21-patient study (small N prints on the face), and present in only 48% of 29 post-cardiac-surgery tamponade cases, where 66% of effusions were localised posterior effusions — a spectrum that does not transport to medical tamponade without that flag. No card presents its absence as excluding tamponade or its presence as confirming it. The oximetry version is a different measurement of the same physiology and prints as the comparison limb (AUC 0.90; derivation / validation split 37 / 37).
MeSH: Adult · Aged · Cardiac Output · Cardiac Tamponade/*diagnosis · *Diastole · Echocardiography · Female · Heart/*physiopathology · *Heart Function Tests · Heart Rate · Humans · Male · Middle Aged · *Myocardial Contraction · Pulmonary Wedge Pressure · Stroke Volume · Aged, 80 and over · *Cardiac Surgical Procedures · Cardiac Tamponade/*diagnosis/diagnostic imaging/physiopathology · Hemodynamics · Postoperative Complications/*diagnosis/diagnostic imaging/physiopathology · Retrospective Studies · Sensitivity and Specificity · Ultrasonography · Cardiac Tamponade/*diagnosis/therapy · *Oximetry · Pericardial Window Techniques · Pericardiocentesis · Plethysmography · Point-of-Care Systems · Prospective Studies · Respiration · Sphygmomanometers
Cards (4)
Card 1 — Prospective study (Singh 1986 — 21 consecutive patients with effusion and suspected tamponade): pulsus paradoxus was 79% sensitive and 40% specific for tamponade, against right-ventricular diastolic collapse at 93% / 100%
Study: Prospective haemodynamic / echocardiographic study (report 1 of 3; small N = 21 prints on the face)
Population: 21 consecutive patients with pericardial effusion and suspected cardiac tamponade, studied prospectively with simultaneous haemodynamic and echocardiographic evaluation before and after pericardiocentesis; tamponade was defined by diastolic equilibration of intrapericardial, right atrial and pulmonary capillary wedge pressures, elevated to more than 10 mmHg. Small N — 21 patients — prints on the face.
Summary: Prospective study (Singh 1986 — 21 consecutive patients with effusion and suspected tamponade): pulsus paradoxus was 79% sensitive and 40% specific for tamponade, against right-ventricular diastolic collapse at 93% / 100%
Result: Pulsus paradoxus was 79% sensitive and 40% specific for cardiac tamponade, with predictive values of 81% (positive) and 40% (negative). Right-ventricular diastolic collapse performed better on every measure: 93% sensitive, 100% specific, predictive values 100% / 83%, as published.
Watch out: Small N (21) and a suspected-tamponade spectrum enriched for disease; the 40% specificity means a positive pulsus paradoxus is weak evidence, and 79% sensitivity means its absence cannot exclude tamponade.
Source: Singh S et al. Usefulness of right ventricular diastolic collapse in diagnosing cardiac tamponade and comparison to pulsus paradoxus.. The American journal of cardiology. 1986. PMID: 3953452. Registry ID: none in the record. MeSH: Adult · Aged · Cardiac Output · Cardiac Tamponade/*diagnosis · *Diastole · Echocardiography · Female · Heart/*physiopathology · *Heart Function Tests · Heart Rate · Humans · Male · Middle Aged · *Myocardial Contraction · Pulmonary Wedge Pressure · Stroke Volume
Card 2 — Post-cardiac-surgery tamponade (Chuttani 1994 — retrospective series of 29 patients): pulsus paradoxus was present in only 48% overall — 50% with circumferential and 47% with regional effusions — and hypotension in only 24%
Study: Retrospective post-cardiac-surgery series (report 2 of 3; small N = 29 prints on the face; sensitivity-side evidence only)
Population: 29 patients with cardiac tamponade after cardiac surgery, evaluated retrospectively for the relative frequency of clinical, echocardiographic and haemodynamic signs; 66% had a localised posterior pericardial effusion and 34% a circumferential effusion. Small N — 29 patients — prints on the face. This report gives sign frequencies in confirmed tamponade (sensitivity-side evidence only), not specificity.
Summary: Post-cardiac-surgery tamponade (Chuttani 1994 — retrospective series of 29 patients): pulsus paradoxus was present in only 48% overall — 50% with circumferential and 47% with regional effusions — and hypotension in only 24%
Result: Pulsus paradoxus was noted in 48% of the whole group (50% circumferential, 47% regional), hypotension in 24%, right-ventricular diastolic collapse in 27% overall but only 5% in regional tamponade — against left-ventricular diastolic collapse in 89% of regional cases — and elevated pressures with equalisation in 81%, as published. The authors conclude post-surgical tamponade usually presents atypically.
Watch out: Post-surgical, mostly localised-effusion spectrum: these frequencies do not transport to medical tamponade. Frequencies in confirmed cases are not an accuracy pair — no specificity may be printed from this report.
Source: Chuttani K et al. Diagnosis of cardiac tamponade after cardiac surgery: relative value of clinical, echocardiographic, and hemodynamic signs.. American heart journal. 1994. PMID: 8154431. Registry ID: none in the record. MeSH: Adult · Aged · Aged, 80 and over · *Cardiac Surgical Procedures · Cardiac Tamponade/*diagnosis/diagnostic imaging/physiopathology · Female · Hemodynamics · Humans · Male · Middle Aged · Postoperative Complications/*diagnosis/diagnostic imaging/physiopathology · Retrospective Studies · Sensitivity and Specificity · Ultrasonography
Card 3 — Oximetry paradoxus (Doukky 2019 — multicentre, 74 subjects, 19 with tamponade): AUC 0.90 (0.84 to 0.97), superior to sphygmomanometer pulsus paradoxus (AUC difference 0.16, p = 0.022); validated thresholds 1.2, 1.5 and 1.7 trade sensitivity against specificity
Study: Multicentre derivation and validation study (report 3 of 3; derivation / validation split 37 / 37)
Population: 74 subjects enrolled across centres (51% men; mean age 54 ± 15 years), 19 with cardiac tamponade confirmed or excluded by blinded echocardiography or right-heart catheterisation; the oximetry paradoxus ratio (maximum-to-minimum pulse-oximetry waveform amplitude over a respiratory cycle, averaged over 3 cycles) was derived in 37 subjects (9 tamponade cases) and validated in an independent 37 (10 cases) — the derivation / validation split prints.
Summary: Oximetry paradoxus (Doukky 2019 — multicentre, 74 subjects, 19 with tamponade): AUC 0.90 (0.84 to 0.97), superior to sphygmomanometer pulsus paradoxus (AUC difference 0.16, p = 0.022); validated thresholds 1.2, 1.5 and 1.7 trade sensitivity against specificity
Result: Oximetry paradoxus AUC was 0.90 (95% CI 0.84 to 0.97), superior to sphygmomanometer-measured pulsus paradoxus (AUC difference 0.16, p = 0.022). The three validated thresholds were 1.2 (100% sensitivity, 44% specificity), 1.5 (80% / 81%) and 1.7 (80% / 89%), and oximetry paradoxus fell significantly after pericardial drainage, as published.
Watch out: A different measurement of the same physiology, carded as the comparison limb — not a validation of the sphygmomanometer sign. Only 19 tamponade cases in total; threshold performance comes from a 37-subject validation cohort.
Source: Doukky R et al. Usefulness of Oximetry Paradoxus to Diagnose Cardiac Tamponade.. The American journal of cardiology. 2019. PMID: 30477799. Registry ID: none in the record. MeSH: Cardiac Tamponade/*diagnosis/therapy · Echocardiography · Female · Humans · Male · Middle Aged · *Oximetry · Pericardial Window Techniques · Pericardiocentesis · Plethysmography · Point-of-Care Systems · Prospective Studies · Respiration · Sensitivity and Specificity · Sphygmomanometers
Card 4 — Synthesis: the classic pulsus paradoxus is neither sensitive enough nor specific enough to rule tamponade in or out — 79% / 40% prospectively, present in under half of post-surgical cases — while the oximetry waveform version (AUC 0.90) performed better in a small derivation / validation study
Study: Synthesis
Population: All reports carded on this shelf: Singh 1986 (prospective, N = 21), Chuttani 1994 (post-surgical series, N = 29) and Doukky 2019 (multicentre derivation / validation, N = 74). Both primary cohorts are small and their Ns print on the face of this shelf.
Summary: Synthesis: the classic pulsus paradoxus is neither sensitive enough nor specific enough to rule tamponade in or out — 79% / 40% prospectively, present in under half of post-surgical cases — while the oximetry waveform version (AUC 0.90) performed better in a small derivation / validation study
Result: This is a diagnostic-accuracy shelf: no card presents the absence of pulsus paradoxus as excluding tamponade or its presence as confirming it, and the post-surgical localised-effusion figures do not transport to medical tamponade without their spectrum flag.
Watch out: See the individual cards for each report's limits; this synthesis adds no new data.
Source: Synthesis of the reports carded above; no additional source.