SourceMed · Shelf #7977 in the ask interface
Thyroid palpation accuracy (4 reports across two sub-questions): palpation tracks volume moderately well in goitre-enriched samples (r² ≈ 0.87) yet misses most nodules — sensitivity 20.3% for solitary nodules and 10.8% for multinodular goitre in unselected adults
Shelf #7977 · Thyroid & parathyroid
PREDICTIVE PERFORMANCE — split by sub-question (4 reports): volume estimation r² 0.856–0.872 against ultrasound in a goitre-enriched cohort, but nodule detection sensitivity only 20.3% (solitary) and 10.8% (multinodular goitre) in unselected adults; a diagnostic-accuracy stamp, not a treatment stamp
Stamped: 2026-11-28.
Evidence published: 1993–2024.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
How accurately does thyroid palpation estimate thyroid size and detect thyroid nodules against ultrasonography — what correlation with ultrasonic volume and inter-observer agreement did the prospective 316-patient study find for endocrinologist and trained-resident palpation, what does the observer-variation review conclude about clinical estimation of size, morphology and function, what sensitivity and specificity did palpation achieve for solitary nodules and multinodular goitre in the 327-patient primary-care study, and how did palpation perform for gland dimensions in 118 children in a goitre-endemic region? (diagnostic-accuracy question; composition: 4 reports across two stated sub-questions — volume estimation and nodule detection.)
Balance of the evidence
Composition prints on the face: 4 reports across two sub-questions (volume estimation; nodule detection) — this family was re-verified upward from 2 to 4 reports by adding the nodule-detection study and the paediatric dimensions study. The two limbs disagree in register: palpation tracks volume moderately well in goitre-enriched samples (r² ≈ 0.87) yet misses most nodules (sensitivity 10.8%–20.3% in unselected adults), and neither limb's figures may be printed as the other's. Examiner grade is part of the measurement (endocrinologist vs trained resident vs primary-care examiners) and prints. The paediatric study is from a goitre-endemic region with age-specific interpretation rules, and the 1997 cohort's mean volumes (≈36–37 mL, printed in the fetched abstract as 35.9 and 37.3 mL) mark a goitre-enriched spectrum, not a screening population.
MeSH: Adolescent · Adult · Aged · Aged, 80 and over · Child · Female · Goiter/*pathology · Humans · Male · Middle Aged · Observer Variation · *Palpation · Prospective Studies · Sensitivity and Specificity · Thyroid Gland/diagnostic imaging/*pathology · Ultrasonography · *Observer Variation · Reproducibility of Results · Statistics as Topic/methods · Thyroid Diseases/*diagnosis · *Goiter · Palpation · Predictive Value of Tests · Retrospective Studies · *Thyroid Neoplasms/diagnosis · *Thyroid Nodule/diagnostic imaging · Age Factors · Child, Preschool · Goiter/*diagnosis · Hypertrophy/diagnosis · Puberty/physiology · Thyroid Gland/*diagnostic imaging/pathology
Cards (5)
Card 1 — Prospective volume study (Nordmeyer 1997 — 316 patients with suspected thyroid disease): palpation-estimated volume correlated with ultrasonographic volume at r² = 0.872 (endocrinologist) and 0.856 (trained resident), with inter-observer r² = 0.893; mean ultrasonic volumes were 35.9 mL and 37.3 mL — a goitre-enriched sample
Study: Prospective volume-estimation study (report 1 of 4; volume limb)
Population: 316 patients with suspected thyroid disease, prospectively studied: thyroid volume assessed by palpation and then by ultrasonic scanning, by an endocrinologist (examiner A, 111 patients) and a resident who had undergone structured palpation training (examiner B, 215 patients); 53 patients were examined by both, and 99 glands contributed to the inter-physician ultrasound agreement (r² = 0.87). Note: the fetched PubMed record gives this journal as Experimental and Clinical Endocrinology & Diabetes, which governs over the slate file's journal naming.
Summary: Prospective volume study (Nordmeyer 1997 — 316 patients with suspected thyroid disease): palpation-estimated volume correlated with ultrasonographic volume at r² = 0.872 (endocrinologist) and 0.856 (trained resident), with inter-observer r² = 0.893; mean ultrasonic volumes were 35.9 mL and 37.3 mL — a goitre-enriched sample
Result: Examiner A's palpation correlated with ultrasound at r² = 0.872 (mean ultrasonic volume 35.9 mL, SD 27.1, range 4–152 mL) and examiner B's at r² = 0.856 (mean 37.3 mL, SD 24.2, range 4–145 mL); inter-observer palpation correspondence was r² = 0.893. The authors conclude quantitative palpation yields sufficiently precise results for clinical purposes and can be taught, as published.
Watch out: A correlation in a goitre-enriched sample (mean volumes ≈36–37 mL) is not accuracy in a screening population, and a volume correlation says nothing about nodule detection — the two limbs of this shelf must never be printed as each other.
Source: Nordmeyer JP et al. How accurate is the assessment of thyroid volume by palpation? A prospective study of 316 patients.. Experimental and clinical endocrinology & diabetes : official journal, German Society of Endocrinology [and] German Diabetes Association. 1997. PMID: 9439935. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Aged, 80 and over · Child · Female · Goiter/*pathology · Humans · Male · Middle Aged · Observer Variation · *Palpation · Prospective Studies · Sensitivity and Specificity · Thyroid Gland/diagnostic imaging/*pathology · Ultrasonography
Card 2 — Observer-variation review (Jarløv 2000 — thesis review): clinical estimation of thyroid size, morphology and functional status was all subject to considerable observer variation, worst for the solitary nodule; a rough small / medium / large division was reproducible and rather accurate, while exact volume estimation by palpation was neither accurate nor reproducible
Study: Observer-variation thesis review (report 2 of 4 — labelled a review; no accuracy pair may be printed from it)
Population: A thesis review of observer variation across thyroid diagnostic modalities — clinical estimation, scintigraphy and ultrasound interpretation — expressing reproducibility as kappa coefficients. Labelled a review; no primary accuracy dataset is carded from it.
Summary: Observer-variation review (Jarløv 2000 — thesis review): clinical estimation of thyroid size, morphology and functional status was all subject to considerable observer variation, worst for the solitary nodule; a rough small / medium / large division was reproducible and rather accurate, while exact volume estimation by palpation was neither accurate nor reproducible
Result: Clinical estimation of thyroid functional status, and of gland size and morphology, was subject to considerable observer variation, greatest for palpation of a solitary nodule, where even experienced doctors had difficulty reproducing their own evaluations; by contrast, interpretation of routine thyroid blood tests was highly reproducible, and even ultrasound morphology descriptions by two specialists were not reproducible. Palpation of size was neither accurate nor reproducible when an exact volume was aimed at, while a rough division into small, medium and large goitres was reproducible and rather accurate, as published.
Watch out: No accuracy pair may be printed from this review. Its caution also cuts the other way: ultrasound, the reference standard on the other cards, itself carries observer variation in morphology description.
Source: Jarløv AE et al. Observer variation in the diagnosis of thyroid disorders. Criteria for and impact on diagnostic decision-making.. Danish medical bulletin. 2000. PMID: 11155660. Registry ID: none in the record. MeSH: Humans · *Observer Variation · Reproducibility of Results · Statistics as Topic/methods · Thyroid Diseases/*diagnosis
Card 3 — Nodule detection (Jacome 2024 — retrospective, random sample of 327 adults, 65.1% women, 54.4% primary care, documented examination before first thyroid ultrasound): palpation sensitivity was 20.3% (specificity 79.1%, PPV 17.6%) for solitary nodules and 10.8% (specificity 96.5%, PPV 73.9%) for multinodular goitre; among 154 palpable-nodule cases, 60% had additional nodules on ultrasound
Study: Retrospective nodule-detection study (report 3 of 4; nodule limb)
Population: 327 adult patients (mean age 50.8 years, SD 16.9; 65.1% female, 84.1% white, 54.4% treated in primary care) who underwent first-time thyroid ultrasound between January 2015 and September 2017 after a documented thyroid physical examination.
Summary: Nodule detection (Jacome 2024 — retrospective, random sample of 327 adults, 65.1% women, 54.4% primary care, documented examination before first thyroid ultrasound): palpation sensitivity was 20.3% (specificity 79.1%, PPV 17.6%) for solitary nodules and 10.8% (specificity 96.5%, PPV 73.9%) for multinodular goitre; among 154 palpable-nodule cases, 60% had additional nodules on ultrasound
Result: For solitary thyroid nodules the physical examination had sensitivity 20.3%, specificity 79.1%, accuracy 68.5%, negative predictive value 81.8% and positive predictive value 17.6%; for multinodular goitre, sensitivity 10.8%, specificity 96.5%, accuracy 55.4%, negative predictive value 53.9% and positive predictive value 73.9%. Among 154 cases with palpable nodules, 60% had additional nodules on subsequent ultrasound, as published.
Watch out: Retrospective and examination-documentation dependent. These are nodule-detection figures in unselected adults — they must not be softened by the volume limb's r² ≈ 0.87, which answers a different sub-question in a different spectrum.
Source: Jacome CS et al. Physical Examination of the Thyroid: Accuracy in Detecting Thyroid Nodules and Frequency of Additional Findings.. Endocrine practice : official journal of the American College of Endocrinology and the American Association of Clinical Endocrinologists. 2024. PMID: 37805101. Registry ID: none in the record. MeSH: Adult · Female · Humans · Male · Middle Aged · *Goiter · Palpation · Predictive Value of Tests · Retrospective Studies · Sensitivity and Specificity · *Thyroid Neoplasms/diagnosis · *Thyroid Nodule/diagnostic imaging · Ultrasonography · Aged
Card 4 — Children in a goitre-endemic region (Kasatkina 1993 — 118 children aged 5 and 14, two palpation modifications against ultrasonographic volumetry): with age-specific interpretation criteria, palpation sensitivity was 63% (±6), specificity 67% (±6) and accuracy 65% (±4) for enlargement, while sensitivity for nodules up to 10 mm was null — 0 of 6 sonographic nodules detected
Study: Paediatric dimensions study — goitre-endemic region (report 4 of 4; paediatric limb)
Population: 118 children aged 5 and 14 of both sexes living in regions endemic for goitre; two modifications of the palpation method were compared with ultrasonographic volumetry, with age-specific corrections to the interpretation criteria (first-degree enlargement in preschool children most often indicated hypertrophy, whereas at pubertal age it was a variant of normal size).
Summary: Children in a goitre-endemic region (Kasatkina 1993 — 118 children aged 5 and 14, two palpation modifications against ultrasonographic volumetry): with age-specific interpretation criteria, palpation sensitivity was 63% (±6), specificity 67% (±6) and accuracy 65% (±4) for enlargement, while sensitivity for nodules up to 10 mm was null — 0 of 6 sonographic nodules detected
Result: With age-specific interpretation, palpation sensitivity for enlargement was 63% (±6), specificity 67% (±6) and accuracy 65% (±4); isthmus thickness was virtually the same regardless of enlargement. Sensitivity for nodules up to 10 mm in diameter was null — sonographic signs of encapsulated formations were seen in 6 of 81 examined adolescents and palpation detected none of them, as published.
Watch out: A goitre-endemic paediatric spectrum with age-specific interpretation rules — these figures do not transport to non-endemic or adult populations. The null small-nodule sensitivity agrees in direction with the adult nodule limb.
Source: Kasatkina EP et al. Ultrasonographic evaluation of the thyroid palpation method in determining its dimensions in children and adolescents].. Problemy endokrinologii. 1993. PMID: 8108341. Registry ID: none in the record. MeSH: Adolescent · Age Factors · Child, Preschool · Female · Goiter/*diagnosis · Humans · Hypertrophy/diagnosis · Male · *Palpation · Predictive Value of Tests · Puberty/physiology · Sensitivity and Specificity · Thyroid Gland/*diagnostic imaging/pathology · Ultrasonography
Card 5 — Synthesis: thyroid palpation's two limbs must be kept apart — it tracks volume moderately well in goitre-enriched, trained-examiner settings (r² ≈ 0.87, inter-observer 0.893) yet misses most nodules in unselected adults (sensitivity 10.8%–20.3%) and all small nodules in the paediatric study, with considerable observer variation throughout
Study: Synthesis
Population: All reports carded on this shelf: Nordmeyer 1997 (316 patients, volume limb), Jarløv 2000 (observer-variation review), Jacome 2024 (327 adults, nodule limb) and Kasatkina 1993 (118 children, paediatric limb) — 4 reports across two stated sub-questions.
Summary: Synthesis: thyroid palpation's two limbs must be kept apart — it tracks volume moderately well in goitre-enriched, trained-examiner settings (r² ≈ 0.87, inter-observer 0.893) yet misses most nodules in unselected adults (sensitivity 10.8%–20.3%) and all small nodules in the paediatric study, with considerable observer variation throughout
Result: This is a diagnostic-accuracy shelf: neither limb's figures may be printed as the other's.
Watch out: See the individual cards for each report's limits; this synthesis adds no new data.
Source: Synthesis of the reports carded above; no additional source.