SourceMed · Shelf #7978 in the ask interface
Amsler grid for neovascular AMD (FLOOR-RISK — exactly 2 overlapping syntheses, counted as syntheses): pooled sensitivity only 67% in the larger meta-analysis vs 0.78 in the earlier one, specificity 99% / 0.97 — one in three conversions missed at the lower estimate
Shelf #7978 · Eyes, skin, nose & allergy
PREDICTIVE PERFORMANCE — FLOOR-RISK, exactly 2 overlapping syntheses (counted as syntheses, never independent cohorts): Amsler grid pooled sensitivity 67% (specificity 99% vs healthy comparators) in 10 studies / 1,890 eyes vs 0.78 / 0.97 in the earlier synthesis; a test-accuracy stamp, not a monitoring-programme endorsement
Stamped: 2026-11-28.
Evidence published: 2014–2023.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
How accurately does the Amsler grid (patient-reported distortion / scotoma on a printed grid) detect neovascular age-related macular degeneration against ophthalmic examination — what pooled sensitivity and specificity does the JAMA Ophthalmology meta-analysis give across its 10 studies and 1,890 eyes, and what pooled figures does the earlier meta-analysis give the Amsler grid vs preferential hyperacuity perimetry? (test-accuracy question. FLOOR-RISK: this shelf rests on exactly 2 syntheses whose primary-study sets overlap, counted as syntheses — the exact basis prints on the title, question, balance, stamp, every card and the Synthesis. Cross-point: fundus photography for diabetic retinopathy, the camera-measurement eye row, is pack #7979.)
Balance of the evidence
FLOOR-RISK — this shelf rests on exactly 2 syntheses whose primary-study sets overlap, and that exact basis prints here and on every card; the count prints as 2 syntheses, never as independent cohorts (the SCOFF precedent). The clinical tension prints: the grid is widely recommended for home monitoring of non-neovascular AMD, yet the larger meta-analysis pools sensitivity at only 67% — one in three neovascular conversions missed — in predominantly case-control spectra that flatter accuracy (all but two studies in the earlier synthesis were case-control). The two syntheses' sensitivity estimates (0.67 vs 0.78) differ with their study sets and neither may be printed as settled. This is a test-accuracy shelf, not a monitoring-programme endorsement. Cross-point: fundus photography for diabetic retinopathy (pack #7979) is a camera measurement in a different disease — a different index test and setting.
MeSH: Humans · Middle Aged · Aged · Aged, 80 and over · Angiogenesis Inhibitors · Visual Acuity · Vascular Endothelial Growth Factor A · *Wet Macular Degeneration/diagnosis · Visual Field Tests/methods · Sensitivity and Specificity · *Geographic Atrophy · False Positive Reactions · Predictive Value of Tests · Reproducibility of Results · Vision Screening/*methods · Visual Acuity/*physiology · Visual Field Tests/*methods · Wet Macular Degeneration/*diagnosis
Cards (4)
Card 1 — FLOOR-RISK synthesis 1 of exactly 2 (Bjerager 2023 — 10 studies, 1,890 eyes): Amsler grid sensitivity for neovascular AMD was 67% (95% CI 51% to 79%) and specificity 99% (85% to 100%) against healthy comparators, and 71% / 63% when comparators were patients with nonneovascular AMD
Study: Systematic review and diagnostic meta-analysis (FLOOR-RISK synthesis 1 of exactly 2, overlapping sets)
Population: 10 studies with a total of 1,890 eyes (mean participant age ranging from 62 to 83 years); groups had neovascular AMD vs either healthy eyes or eyes with nonneovascular AMD, with the Amsler grid as index test and ophthalmic examination as the reference standard. FLOOR-RISK basis: this is one of exactly 2 overlapping syntheses on this shelf, counted as a synthesis.
Summary: FLOOR-RISK synthesis 1 of exactly 2 (Bjerager 2023 — 10 studies, 1,890 eyes): Amsler grid sensitivity for neovascular AMD was 67% (95% CI 51% to 79%) and specificity 99% (85% to 100%) against healthy comparators, and 71% / 63% when comparators were patients with nonneovascular AMD
Result: Sensitivity and specificity for neovascular AMD were 67% (95% CI 51% to 79%) and 99% (85% to 100%) when comparators were healthy control participants, and 71% and 63% respectively when control participants were patients with nonneovascular AMD, as published. The authors conclude the grid's sensitivity may be at levels typically not recommended for monitoring, and that at-risk patients should be encouraged to undergo regular ophthalmic examination regardless of Amsler grid self-assessment results.
Watch out: The comparator moves specificity from 99% (healthy) to 63% (nonneovascular AMD — the actual monitoring population); printing only the 99% figure would misstate the test. One of exactly 2 overlapping syntheses — not an independent confirmation of the other.
Source: Bjerager J et al. Diagnostic Accuracy of the Amsler Grid Test for Detecting Neovascular Age-Related Macular Degeneration: A Systematic Review and Meta-analysis.. JAMA ophthalmology. 2023. PMID: 36795396. Registry ID: none in the record. MeSH: Humans · Middle Aged · Aged · Aged, 80 and over · Angiogenesis Inhibitors · Visual Acuity · Vascular Endothelial Growth Factor A · *Wet Macular Degeneration/diagnosis · Visual Field Tests/methods · Sensitivity and Specificity · *Geographic Atrophy
Card 2 — FLOOR-RISK synthesis 2 of exactly 2 (Faes 2014 — 12 studies, 903 patients, 27 two-by-two tables): pooled Amsler grid sensitivity was 0.78 (0.64 to 0.87) and specificity 0.97 (0.91 to 0.99), with likelihood ratios labelled as such (positive 23.1, negative 0.23), against preferential hyperacuity perimetry at 0.85 / 0.87; all but two studies had a case-control design
Study: Systematic review and meta-analysis (FLOOR-RISK synthesis 2 of exactly 2, overlapping sets)
Population: 12 included studies enrolling 903 patients, allowing 27 two-by-two tables (12 on the Amsler grid and its modifications, 12 on preferential hyperacuity perimetry, the remainder on other charts); all but two studies had a case-control design. FLOOR-RISK basis: this is the second of exactly 2 overlapping syntheses on this shelf, counted as a synthesis.
Summary: FLOOR-RISK synthesis 2 of exactly 2 (Faes 2014 — 12 studies, 903 patients, 27 two-by-two tables): pooled Amsler grid sensitivity was 0.78 (0.64 to 0.87) and specificity 0.97 (0.91 to 0.99), with likelihood ratios labelled as such (positive 23.1, negative 0.23), against preferential hyperacuity perimetry at 0.85 / 0.87; all but two studies had a case-control design
Result: Pooled Amsler grid sensitivity was 0.78 (95% CI 0.64 to 0.87) and specificity 0.97 (0.91 to 0.99), with positive likelihood ratio 23.1 (8.4 to 64.0) and negative 0.23 (0.14 to 0.39), labelled as such; preferential hyperacuity perimetry pooled at sensitivity 0.85 and specificity 0.87. The authors present both tests as promising for ruling out wet AMD in the screening setting, while noting transfer to real clinical practice still needs to be established, as published.
Watch out: Predominantly case-control spectra flatter accuracy. Its 0.78 sensitivity estimate and the 2023 synthesis's 0.67 differ with their study sets — neither may be printed as settled, and the two syntheses overlap and are not independent.
Source: Faes L et al. Diagnostic accuracy of the Amsler grid and the preferential hyperacuity perimetry in the screening of patients with age-related macular degeneration: systematic review and meta-analysis.. Eye (London, England). 2014. PMID: 24788016. Registry ID: none in the record. MeSH: False Positive Reactions · Humans · Predictive Value of Tests · Reproducibility of Results · Vision Screening/*methods · Visual Acuity/*physiology · Visual Field Tests/*methods · Wet Macular Degeneration/*diagnosis
Card 3 — Cross-synthesis summary of the two carded syntheses — not an additional synthesis (FLOOR-RISK): sensitivity 0.67 vs 0.78 and specificity 0.97–0.99 against healthy comparators, falling to 63% specificity against the nonneovascular-AMD population the test is actually used in
Study: Cross-synthesis summary of the two carded syntheses — not an additional synthesis (FLOOR-RISK)
Population: The same two syntheses carded above (Bjerager 2023, 10 studies / 1,890 eyes; Faes 2014, 12 studies / 903 patients). This card adds no report, no dataset and no source — it exists so the FLOOR-RISK shelf reaches its card floor without inventing a third evidence unit.
Summary: Cross-synthesis summary of the two carded syntheses — not an additional synthesis (FLOOR-RISK): sensitivity 0.67 vs 0.78 and specificity 0.97–0.99 against healthy comparators, falling to 63% specificity against the nonneovascular-AMD population the test is actually used in
Result: Read together, the two overlapping syntheses agree that specificity against healthy comparators is high (0.97–0.99) and disagree on sensitivity (0.67 vs 0.78); against patients with nonneovascular AMD — the home-monitoring population — the 2023 synthesis gives specificity of only 63%. At the larger synthesis's 67% sensitivity, roughly one in three neovascular conversions would be missed by the grid.
Watch out: FLOOR-RISK basis restated: exactly 2 overlapping syntheses, counted as syntheses. This summary card is explicitly not a third synthesis and must never be counted as one.
Source: Bjerager J et al. Diagnostic Accuracy of the Amsler Grid Test for Detecting Neovascular Age-Related Macular Degeneration: A Systematic Review and Meta-analysis.. JAMA ophthalmology. 2023. PMID: 36795396. Registry ID: none in the record. MeSH: Humans · Middle Aged · Aged · Aged, 80 and over · Angiogenesis Inhibitors · Visual Acuity · Vascular Endothelial Growth Factor A · *Wet Macular Degeneration/diagnosis · Visual Field Tests/methods · Sensitivity and Specificity · *Geographic Atrophy
Card 4 — Synthesis (FLOOR-RISK — exactly 2 overlapping syntheses, counted as syntheses): the Amsler grid is highly specific against healthy eyes but misses a substantial minority of neovascular AMD — pooled sensitivity 67% in the larger, later synthesis vs 0.78 in the earlier one — so a normal grid cannot substitute for regular ophthalmic examination in at-risk patients
Study: Synthesis
Population: All reports carded on this shelf: Bjerager 2023 and Faes 2014 — exactly 2 syntheses whose primary-study sets overlap, counted as syntheses, plus a labelled cross-synthesis summary card that is not an additional synthesis. Cross-point: fundus photography for diabetic retinopathy is pack #7979.
Summary: Synthesis (FLOOR-RISK — exactly 2 overlapping syntheses, counted as syntheses): the Amsler grid is highly specific against healthy eyes but misses a substantial minority of neovascular AMD — pooled sensitivity 67% in the larger, later synthesis vs 0.78 in the earlier one — so a normal grid cannot substitute for regular ophthalmic examination in at-risk patients
Result: This is a test-accuracy shelf, not a monitoring-programme endorsement: the exact FLOOR-RISK basis prints on the title, question, balance, stamp, every card and this Synthesis.
Watch out: See the individual cards for each report's limits; this synthesis adds no new data.
Source: Synthesis of the reports carded above; no additional source.