Serum GDF-15 reference intervals (PHYS, EMERGING): the two European derivations' upper reference limits disagree by over 50% — 866 ng/L vs 1,335 ng/L — and print side by side; no merged interval exists
Shelf #7981 · Heart, vessels, blood pressure & clotting
PHYSIOLOGY — EMERGING: 3 independent derivations, one assay family for the two European studies, materially discordant upper reference limits (866 vs 1,335 ng/L) printed side by side; no merged reference interval may be printed
Stamped: 2026-11-28.
Evidence published: 2019–2025.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
What are the reference intervals for serum growth differentiation factor 15 (GDF-15) in healthy adults — what interval did the multicentre Chinese-population study establish, what interval (2.5th–97.5th percentile) did the Irish Caucasian study derive on the Roche electrochemiluminescence assay from its eligible healthy volunteers, what upper reference limit did the 533-person screened cohort derive after exclusions, and how large is the within-subject biological variation? (PHYSIOLOGY question. Values are in ng/L (= pg/mL) throughout — the same number in both units, stated here so no conversion is needed or printed twice.)
Balance of the evidence
PHYSIOLOGY — EMERGING. Assay and population dependence is the headline: the two European derivations' upper reference limits disagree by over 50% (866 vs 1,335 ng/L) on the same assay family, driven by exclusion stringency and age mix — the discordant limits print side by side, each interval prints with its population, exclusion rules and assay, and no merged interval may be printed. The eligible-N fractions print (125 of 188; 173 of 533) — reference populations here are heavily screened subsets. Age raises GDF-15 in both European datasets and in the Chinese derivation, and prints. The Irish study's diabetic-kidney-disease limb (AUC 0.931 at a >1,136 ng/L cut-off) is a diagnostic limb in a disease cohort, NOT normative data, and is carded only as labelled context on its own card. Within-subject biological variation (CV 6.3%, reference change value 23%) is part of the physiology and prints.
MeSH: Adolescent · Adult · Cohort Studies · Cross-Sectional Studies/standards · Diabetes Mellitus/*blood/diagnosis · Diabetic Nephropathies/*blood/diagnosis · Female · Growth Differentiation Factor 15/*blood/standards · Humans · Male · Middle Aged · ROC Curve · Reference Values · White People · Young Adult · Aged · Biomarkers/blood · C-Reactive Protein/analysis · Growth Differentiation Factor 15/*blood · Natriuretic Peptide, Brain/blood · Regression Analysis
Cards (4)
Card 1 — Chinese-population derivation (Chen 2025 — 8,488 eligible subjects enrolled from six cities, 7,764 analysed after 724 outliers were excluded): age- and sex-specific reference intervals were established on the Maccura i3000 chemiluminescence assay; GDF-15 rose with age (all P < 0.001) and was higher in males than females except at ages 18–29
Study: Multicentre reference-interval derivation — Chinese population (dataset 1 of 3)
Population: Apparently healthy Chinese individuals enrolled at six representative cities under unified, stringent criteria: 8,488 eligible subjects, with 7,764 included in the analysis after Tukey-test outlier exclusion (724 excluded). Serum GDF-15 was measured on the Maccura Biotechnology i3000 automatic chemiluminescence analyser. The fetched PubMed record carries no MeSH terms — the source line states 'none in the record' — and its abstract reports that age- and sex-specific intervals were established without printing the interval values, so no numeric interval is printed on this card.
Summary: Chinese-population derivation (Chen 2025 — 8,488 eligible subjects enrolled from six cities, 7,764 analysed after 724 outliers were excluded): age- and sex-specific reference intervals were established on the Maccura i3000 chemiluminescence assay; GDF-15 rose with age (all P < 0.001) and was higher in males than females except at ages 18–29
Result: GDF-15 levels were skewed in distribution, increased with age (all P < 0.001) and were higher in males than in females (all P < 0.001, except ages 18–29, P = 0.373); the standard deviation ratio for age intervals was 0.83 and for sex <0.01 in the nested analysis of variance. The authors conclude GDF-15 levels in the Chinese population are comparable to those in European populations, with the exception of the sex-based differences, as published.
Watch out: A different assay (Maccura chemiluminescence) from the Roche electrochemiluminescence assay of the two European datasets — cross-assay comparability is asserted by the authors, not established by a shared protocol, and no interval value may be imported into this card from the other datasets.
Source: Chen K et al. A Multicenter Study for Establishing Reference Intervals of Serum GDF-15 Levels Based on the Chinese Population.. Journal of inflammation research. 2025. PMID: 40703640. Registry ID: none in the record. MeSH: none in the record
Card 2 — Irish derivation (Hamon 2019 — 188 healthy volunteers recruited, only 125 meeting inclusion criteria): the reference interval on the Roche electrochemiluminescence assay was 399 ng/L to 1,335 ng/L (upper limit 90% CI 1,152 to 1,445) — one of the two discordant upper limits printed side by side on this shelf
Study: Reference-interval derivation — Irish Caucasian population, Roche ECLIA (dataset 2 of 3)
Population: 188 healthy Irish Caucasian volunteers recruited, of whom 63 failed to meet the study inclusion criteria, leaving 125 eligible for the reference-interval derivation (2.5th–97.5th percentiles) on the Roche Diagnostics electrochemiluminescence immunoassay. The eligible fraction (125 of 188) prints — the reference population is a screened subset. A separate diabetic cohort in the same report is a disease population, not normative data.
Summary: Irish derivation (Hamon 2019 — 188 healthy volunteers recruited, only 125 meeting inclusion criteria): the reference interval on the Roche electrochemiluminescence assay was 399 ng/L to 1,335 ng/L (upper limit 90% CI 1,152 to 1,445) — one of the two discordant upper limits printed side by side on this shelf
Result: The reference interval for serum GDF-15 was 399 ng/L (90% CI 399 to 399) to 1,335 ng/L (90% CI 1,152 to 1,445), as published. Labelled context only — not a reference value: in the report's separate diabetic-kidney-disease limb, the area under the ROC curve was 0.931 and a cut-off of >1,136 ng/L gave sensitivity 94.4% and specificity 79% for diabetic kidney disease; that is a diagnostic limb in a disease cohort and must never be printed as a reference limit.
Watch out: Upper limit 1,335 ng/L — compare card 3's 866 ng/L on the same assay family: the >50% discordance is the headline of this shelf and neither limit may be printed without the other in any summary. Heavily screened subset (125 of 188).
Source: Hamon SM et al. Defining reference intervals for a serum growth differentiation factor-15 (GDF-15) assay in a Caucasian population and its potential utility in diabetic kidney disease (DKD).. Clinical chemistry and laboratory medicine. 2019. PMID: 30218600. Registry ID: none in the record. MeSH: Adolescent · Adult · Cohort Studies · Cross-Sectional Studies/standards · Diabetes Mellitus/*blood/diagnosis · Diabetic Nephropathies/*blood/diagnosis · Female · Growth Differentiation Factor 15/*blood/standards · Humans · Male · Middle Aged · ROC Curve · Reference Values · White People · Young Adult
Card 3 — Screened-cohort derivation (Krintus 2019 — 533 questionnaire-screened adults, only 173 retained after stringent exclusions): the upper reference limit was 866 ng/L (90% CI 733 to 999) with no sex difference; within-subject CV was 6.3% and the reference change value 23% in the 26-volunteer biological-variation substudy
Study: Reference-interval derivation with biological-variation substudy (dataset 3 of 3)
Population: 533 questionnaire-screened, presumably healthy adults used to identify determinants of serum GDF-15; after stringent exclusion criteria a final group of 173 individuals established the reference interval (eligible fraction 173 of 533 prints). Twenty-six healthy volunteers formed the biological-variation substudy. Age, B-type natriuretic peptide, C-reactive protein and smoking status were significant determinants in multiple regression.
Summary: Screened-cohort derivation (Krintus 2019 — 533 questionnaire-screened adults, only 173 retained after stringent exclusions): the upper reference limit was 866 ng/L (90% CI 733 to 999) with no sex difference; within-subject CV was 6.3% and the reference change value 23% in the 26-volunteer biological-variation substudy
Result: The upper reference limit was 866 ng/L (90% CI 733 to 999), with no sex-related difference; although GDF-15 tended to increase with age, the dependence was too weak to justify an age-related upper limit. Within-subject CV was 6.3% (95% CI 4.5% to 8.5%), the reference change value was 23%, and two specimens are required for a mean result within ±10% of an individual's homeostatic set point, as published.
Watch out: Upper limit 866 ng/L — compare card 2's 1,335 ng/L: the discordance is driven by exclusion stringency (173 of 533 retained here) and age mix, and no merged interval may be printed. The low within-subject variation (6.3%) is what makes the 23% reference change value usable for longitudinal interpretation.
Source: Krintus M et al. A study of biological and lifestyle factors, including within-subject variation, affecting concentrations of growth differentiation factor 15 in serum.. Clinical chemistry and laboratory medicine. 2019. PMID: 30471215. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Biomarkers/blood · C-Reactive Protein/analysis · Cohort Studies · Female · Growth Differentiation Factor 15/*blood · Humans · Male · Middle Aged · Natriuretic Peptide, Brain/blood · Regression Analysis · Young Adult
Card 4 — Synthesis (PHYSIOLOGY — EMERGING): three derivations establish that GDF-15 rises with age and that within-subject variation is small (CV 6.3%, reference change value 23%), but they do not establish one reference interval — the European upper limits of 866 and 1,335 ng/L disagree by over 50% and print side by side, and the Chinese derivation's intervals are assay- and population-specific
Study: Synthesis
Population: All datasets carded on this shelf: Chen 2025 (7,764 analysed, Chinese population, Maccura assay), Hamon 2019 (125 eligible of 188, Irish Caucasian, Roche ECLIA) and Krintus 2019 (173 retained of 533 screened, Roche assay family). Values are in ng/L (= pg/mL) throughout.
Summary: Synthesis (PHYSIOLOGY — EMERGING): three derivations establish that GDF-15 rises with age and that within-subject variation is small (CV 6.3%, reference change value 23%), but they do not establish one reference interval — the European upper limits of 866 and 1,335 ng/L disagree by over 50% and print side by side, and the Chinese derivation's intervals are assay- and population-specific
Result: PHYSIOLOGY — EMERGING framing: no merged reference interval is printed anywhere on this shelf, by design.
Watch out: See the individual cards for each report's limits; this synthesis adds no new data.
Source: Synthesis of the reports carded above; no additional source.