SourceMed · Shelf #8007 in the ask interface
Elder-abuse screening and the EASI: sensitivity 0.47 in its only validation — a suspicion-raiser that misses over half of confirmed cases, in a field with no outcome-evaluated tool
Shelf #8007 · Geriatrics, frailty & deprescribing
PREDICTIVE PERFORMANCE — NOT ESTABLISHED as a rule-out: EASI sensitivity 0.47 / specificity 0.75 in its single validation (953 cognitively intact seniors); the 11-tool systematic review could recommend no tool and none was evaluated against outcomes; the long-term-care adaptation reports no accuracy data; a screening-accuracy stamp, not an outcomes stamp
Stamped: 2026-11-28.
Evidence published: 2008–2019.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
How accurately do brief elder-abuse screening instruments identify abuse of older adults — what sensitivity and specificity did the Elder Abuse Suspicion Index (EASI, 6 physician-asked questions) achieve against a blinded detailed social-work evaluation in 953 cognitively intact seniors, what does the systematic review find across the eleven instruments in use, and what did the long-term-care adaptation of the EASI change?
Balance of the evidence
Composition printed on the face: 1 validation (EASI, programme-labelled) + 1 systematic review of 11 tools (counted as a synthesis, never an independent confirmation) + 1 adaptation without accuracy data (EASI-ltc). The EASI's verified sensitivity is low (0.47 — over half of social-work-confirmed cases missed) against a suspicion-raising purpose, and no card may present it as a rule-out. The derivation population was cognitively intact ambulatory seniors — accuracy in cognitively impaired or institutional populations is not verified, and the LTC version is unvalidated for accuracy. The USPSTF evidence report's elder-abuse limb is context only: that report is carded on the IPV shelf #7975 for its IPV limb, this shelf cards the elder-abuse-specific set that shelf could not verify, and the cross-point is in prose only — no anchor is borrowed from #7975. This shelf's own review found no instrument evaluated against outcomes; that finding prints beside any accuracy headline.
MeSH: Aged · Elder Abuse/prevention & control · Family Practice · Female · Geriatric Assessment · Humans · Male · Mass Screening · Quebec · Reproducibility of Results · Sensitivity and Specificity · Surveys and Questionnaires · Elder Abuse/prevention & control,psychology · Health Services for the Aged · Nursing Diagnosis · Nursing Homes · Psychometrics · Aged, 80 and over · Canada · Cross-Sectional Studies · Elder Abuse/diagnosis · Focus Groups · Geriatric Assessment/methods · Homes for the Aged · Long-Term Care/organization & administration · Mental Status and Dementia Tests
Cards (4)
Card 1 — EASI development and validation (Yaffe 2008 — 104 family doctors administering the 6-question index to 953 cognitively intact ambulatory seniors against a later blinded Social Work Evaluation; programme-labelled, the Yaffe group's own report): estimated sensitivity 0.47 and specificity 0.75, administration under 2 minutes — over half of social-work-confirmed cases missed
Study: Development and validation study (report 1 of 3 — programme-labelled)
Population: 953 cognitively intact seniors in ambulatory care, administered the 6-question Elder Abuse Suspicion Index by 104 family doctors, compared with a detailed Social Work Evaluation administered later by social workers blinded to the EASI results.
Summary: EASI development and validation (Yaffe 2008 — 104 family doctors administering the 6-question index to 953 cognitively intact ambulatory seniors against a later blinded Social Work Evaluation; programme-labelled, the Yaffe group's own report): estimated sensitivity 0.47 and specificity 0.75, administration under 2 minutes — over half of social-work-confirmed cases missed
Result: The EASI had an estimated sensitivity of 0.47 and specificity of 0.75, usually took less than 2 minutes to ask, and 97.2% of doctors felt it would have some or big practice impact, as published.
Watch out: A sensitivity of 0.47 against a suspicion-raising purpose: this instrument cannot rule elder abuse out, and no card may present it as a rule-out. The derivation population was cognitively intact ambulatory seniors.
Source: Yaffe MJ et al. Development and validation of a tool to improve physician identification of elder abuse: the Elder Abuse Suspicion Index (EASI).. Journal of elder abuse & neglect. 2008. PMID: 18928055. Registry ID: none in the record. MeSH: Aged · Elder Abuse/prevention & control · Family Practice · Female · Geriatric Assessment · Humans · Male · Mass Screening · Quebec · Reproducibility of Results · Sensitivity and Specificity · Surveys and Questionnaires
Card 2 — Systematic review of elder-abuse screening tools (Gallione 2017 — 11 tools identified: H-S/EAST, VASS, EASI, CASE, BASE, E-IOA, EAI, EPAS, CPEABS, OAPAM, OAFEM): some tools showed moderate-to-good internal consistency and some were validated for early identification, but NONE was evaluated against measurable violence or health outcomes, and the reviewers could not recommend a single tool
Study: Systematic review — synthesis (report 2 of 3, counted as a synthesis)
Population: Systematic review of 695 screened articles yielding 11 included studies presenting 11 elder-abuse screening tools, appraised with the PRISMA statement and STROBE checklist.
Summary: Systematic review of elder-abuse screening tools (Gallione 2017 — 11 tools identified: H-S/EAST, VASS, EASI, CASE, BASE, E-IOA, EAI, EPAS, CPEABS, OAPAM, OAFEM): some tools showed moderate-to-good internal consistency and some were validated for early identification, but NONE was evaluated against measurable violence or health outcomes, and the reviewers could not recommend a single tool
Result: Eleven screening tools were presented, all aimed at healthcare professionals; some demonstrated moderate-to-good internal consistency and some were validated for early identification, but none had been evaluated against measurable violence or health outcomes, and the reviewers were not able to recommend a single tool, as published.
Watch out: Counted as a synthesis, never as an independent confirmation of the EASI validation. Its no-outcomes finding prints beside any accuracy headline on this shelf.
Source: Gallione C et al. Screening tools for identification of elder abuse: a systematic review.. Journal of clinical nursing. 2017. PMID: 28042891. Registry ID: none in the record. MeSH: Aged · Elder Abuse/prevention & control,psychology · Health Services for the Aged · Humans · Nursing Diagnosis · Nursing Homes · Psychometrics
Card 3 — Long-term-care adaptation (Ballard 2019 — expert consultation n=19; focus groups n=7 + 7) — ADAPTATION WITHOUT ACCURACY DATA: the 9-question EASI-ltc adds three neglect/psychological-abuse questions and a context-specific preamble to the original EASI; it reports no accuracy data and none may be printed from it
Study: Mixed-methods adaptation study — no accuracy data (report 3 of 3)
Population: Canadian elder-abuse experts consulted online (n = 19) and two purposively selected focus groups (n = 7 local elder-abuse experts; n = 7 experienced front-line long-term-care clinicians), adapting the EASI — originally created for ambulatory older adults with MMSE scores of 24 or above — for cognitively intact long-term-care residents.
Summary: Long-term-care adaptation (Ballard 2019 — expert consultation n=19; focus groups n=7 + 7) — ADAPTATION WITHOUT ACCURACY DATA: the 9-question EASI-ltc adds three neglect/psychological-abuse questions and a context-specific preamble to the original EASI; it reports no accuracy data and none may be printed from it
Result: The adaptation produced the nine-question EASI-ltc, with three new questions addressing neglect and psychological abuse and a context-specific preamble, as published. No sensitivity, specificity or other accuracy figure is reported in this study.
Watch out: Labelled an adaptation study on the face: the EASI-ltc is unvalidated for accuracy, and accuracy in cognitively impaired or institutional populations is not what the original derivation verifies.
Source: Ballard SA et al. Adapting the Elder Abuse Suspicion Index© for Use in Long-Term Care: A Mixed-Methods Approach.. Journal of applied gerontology : the official journal of the Southern Gerontological Society. 2019. PMID: 29165023. Registry ID: none in the record. MeSH: Aged · Aged, 80 and over · Canada · Cross-Sectional Studies · Elder Abuse/diagnosis · Female · Focus Groups · Geriatric Assessment/methods · Homes for the Aged · Humans · Long-Term Care/organization & administration · Male · Mental Status and Dementia Tests · Nursing Homes
Card 4 — Synthesis — 1 validation + 1 systematic review + 1 adaptation without accuracy data: a low-sensitivity suspicion index, a field whose own review recommends no single tool, and no instrument evaluated against outcomes
Study: Synthesis
Population: Three reports, composition printed here and on the face: the EASI validation, an 11-tool systematic review (counted as a synthesis), and the EASI-ltc adaptation (no accuracy data). Context in prose only, not counted and not borrowed as an anchor: the USPSTF evidence report carded on the intimate-partner-violence shelf #7975 for its IPV limb also covers elder abuse in scope — the elder-abuse-specific set carded here is the set the IPV shelf could not verify, and the two shelves cross-point in prose only.
Summary: Synthesis — 1 validation + 1 systematic review + 1 adaptation without accuracy data: a low-sensitivity suspicion index, a field whose own review recommends no single tool, and no instrument evaluated against outcomes
Result: The EASI's verified sensitivity is 0.47 — over half of social-work-confirmed cases missed — against a stated purpose of raising suspicion and prompting referral, in under 2 minutes. Across all 11 tools in use, none has been evaluated against measurable violence or health outcomes. The long-term-care version exists as an adaptation only.
Watch out: This is a screening-accuracy shelf whose own review found no instrument evaluated against outcomes — that finding prints beside any accuracy headline.
Source: Synthesis of the reports carded above; no additional source.