SourceMed · Shelf #8009 in the ask interface
Cardiac auscultation for valve disease: useful likelihood ratios in cardiologist hands, but only 35.5% of significant valve disease had an audible murmur in the general population
Shelf #8009 · Heart, vessels, blood pressure & clotting
PREDICTIVE PERFORMANCE: positive likelihood ratios 10.87 (diminished second heart sound) and 9.04 (delayed carotid upstroke) and negative likelihood ratio 0.11 (absent neck radiation) for at least moderate aortic stenosis in a low-quality-evidence meta-analysis; RCE likelihood-ratio ranges span an order of magnitude and rest mostly on cardiologist examiners; in the general-population Tromsø study only 35.5% of significant valve disease had an audible murmur to GPs (sensitivity 43% for aortic and 29% for mitral regurgitation, specificity above 94%); a diagnostic-accuracy stamp, not a screening endorsement
Stamped: 2026-11-28.
Evidence published: 1997–2025.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
How accurately does cardiac auscultation and the associated bedside examination identify valvular heart disease against echocardiography or catheterisation — what likelihood ratios does the meta-analysis give the diminished second heart sound, the delayed carotid upstroke and the absent neck radiation of the murmur for at least moderate aortic stenosis, what did the Rational Clinical Examinations find for abnormal systolic murmurs and for the early diastolic murmur of aortic regurgitation, and how did general practitioners' murmur detection perform in the 2,082-participant general-population Tromsø study?
Balance of the evidence
This is a diagnostic-accuracy shelf, not a screening-programme endorsement. Examiner spectrum is the headline caveat and prints with every figure: the meta-analysis and Rational Clinical Examination evidence rests mostly on cardiologist examiners, while the one general-population study used GP-classified recorded heart sounds and found most significant valve disease inaudible (only 35.5% with a murmur) — the two spectra may not be merged into a single accuracy claim. The syntheses are counted as syntheses, never as independent confirmations. Likelihood-ratio ranges in the 1997 RCE span an order of magnitude across studies (2.8–130) and print as ranges; target severity prints (at least moderate AS; mild-or-greater vs moderate-or-greater AR); the meta-analysis's own low-quality grading prints.
MeSH: Cardiology · Cardiomyopathy, Hypertrophic/diagnosis · Decision Support Techniques · Heart Auscultation · Heart Function Tests · Heart Murmurs/diagnosis,etiology · Heart Sounds · Heart Valve Diseases/diagnosis · Humans · Physical Examination · Predictive Value of Tests · Reproducibility of Results · Systole · Aortic Valve Insufficiency/diagnosis · Diastole · Heart Murmurs/complications,diagnosis,etiology · Middle Aged · Mitral Valve Stenosis/diagnosis · Pulse · Renal Insufficiency/complications · Male · Female · Heart Murmurs/epidemiology,diagnosis,etiology · Aged · Prevalence · Heart Auscultation/methods · Echocardiography · Norway/epidemiology · Mitral Valve Insufficiency/epidemiology,diagnosis · Adult · Heart Valve Diseases/epidemiology,diagnosis · Aged, 80 and over · Aortic Valve Stenosis/epidemiology,diagnosis · Aortic Valve Insufficiency/epidemiology,diagnosis
Cards (5)
Card 1 — Aortic-stenosis examination meta-analysis (Shellenberger 2023 — systematic review and meta-analysis, 7 observational studies, examination before catheterisation or echocardiography): a diminished second heart sound had a positive likelihood ratio (labelled as such) of 10.87 (3.94 to 30.12), a delayed carotid upstroke 9.04 (3.12 to 25.44), and absence of a systolic murmur radiating to the neck a negative likelihood ratio of 0.11 (0.06 to 0.23) for at least moderate aortic stenosis — the authors grade the evidence LOW quality
Study: Systematic review and meta-analysis — synthesis (report 1 of 4, counted as a synthesis)
Population: 7 observational studies of patients receiving a cardiovascular physical examination before left heart catheterisation or echocardiogram, for aortic stenosis of at least moderate severity.
Summary: Aortic-stenosis examination meta-analysis (Shellenberger 2023 — systematic review and meta-analysis, 7 observational studies, examination before catheterisation or echocardiography): a diminished second heart sound had a positive likelihood ratio (labelled as such) of 10.87 (3.94 to 30.12), a delayed carotid upstroke 9.04 (3.12 to 25.44), and absence of a systolic murmur radiating to the neck a negative likelihood ratio of 0.11 (0.06 to 0.23) for at least moderate aortic stenosis — the authors grade the evidence LOW quality
Result: Auscultating a diminished second heart sound (likelihood ratio 10.87, 95% CI 3.94 to 30.12) and palpating a delayed carotid upstroke (likelihood ratio 9.04, 3.12 to 25.44) were useful for detecting AS of at least moderate severity; absence of a systolic murmur radiating to the neck (likelihood ratio 0.11, 0.06 to 0.23) rules against it; the evidence is low quality, as published.
Watch out: Counted as a synthesis, never as an independent confirmation of the primary studies inside it. Its PubMed record carries no MeSH terms (printed as none in the record on its source line). Target severity is at least moderate AS and prints.
Source: Shellenberger RA et al. Bedside Physical Examination for the Diagnosis of Aortic Stenosis: A Systematic Review and Meta-analysis.. CJC open. 2023. PMID: 37377515. Registry ID: none in the record. MeSH: none in the record
Card 2 — Rational Clinical Examination — abnormal systolic murmur (Etchells 1997): inter-rater reliability of systolic-murmur detection was only fair (κ 0.30–0.48); the most useful findings for aortic stenosis were a slow carotid rise (positive likelihood ratio 2.8–130), a mid-to-late-peaking murmur (8.0–101) and a decreased second heart sound (3.1–50), and absence of radiation to the right carotid best excluded it (negative likelihood ratio 0.05–0.10) — ranges spanning an order of magnitude, printed as ranges
Study: Rational Clinical Examination — synthesis (report 2 of 4, counted as a synthesis)
Population: Rational Clinical Examination review of the precision and accuracy of the clinical examination for abnormal systolic murmurs; most included studies used cardiologist examiners — the examiner spectrum prints with every figure from this report.
Summary: Rational Clinical Examination — abnormal systolic murmur (Etchells 1997): inter-rater reliability of systolic-murmur detection was only fair (κ 0.30–0.48); the most useful findings for aortic stenosis were a slow carotid rise (positive likelihood ratio 2.8–130), a mid-to-late-peaking murmur (8.0–101) and a decreased second heart sound (3.1–50), and absence of radiation to the right carotid best excluded it (negative likelihood ratio 0.05–0.10) — ranges spanning an order of magnitude, printed as ranges
Result: Reliability of detecting systolic murmurs in the clinical setting was fair (kappa 0.30–0.48). For aortic stenosis, a slow rate of rise of the carotid pulse (positive likelihood ratio 2.8–130), mid-to-late peak intensity of the murmur (8.0–101) and decreased intensity of the second heart sound (3.1–50) were most useful for ruling in, and absence of murmur radiation to the right carotid artery (negative likelihood ratio 0.05–0.10) for ruling out; smaller, lower-quality studies supported cardiologist accuracy for mitral regurgitation, tricuspid regurgitation, hypertrophic cardiomyopathy and mitral valve prolapse, as published.
Watch out: The authors' own conclusion is that the examination BY CARDIOLOGISTS is accurate and that studies of noncardiologists are needed — that sentence governs any use of these ranges for generalist practice.
Source: Etchells E et al. Does this patient have an abnormal systolic murmur?. JAMA. 1997. PMID: 9032164. Registry ID: none in the record. MeSH: Cardiology · Cardiomyopathy, Hypertrophic/diagnosis · Decision Support Techniques · Heart Auscultation · Heart Function Tests · Heart Murmurs/diagnosis,etiology · Heart Sounds · Heart Valve Diseases/diagnosis · Humans · Physical Examination · Predictive Value of Tests · Reproducibility of Results · Systole
Card 3 — Rational Clinical Examination — aortic regurgitation (Choudhry 1999 — 16 studies): cardiologists' precision for diastolic murmurs was moderate on audiotapes (κ 0.51) and good clinically (94% agreement); an early diastolic murmur had a positive likelihood ratio of 8.8–32.0 for mild-or-greater and 4.0–8.3 for moderate-or-greater regurgitation, and its absence a negative likelihood ratio of 0.2–0.3 / 0.1 respectively
Study: Rational Clinical Examination — synthesis (report 3 of 4, counted as a synthesis)
Population: 16 studies of the precision and accuracy of clinical examination for aortic regurgitation; most studies assessed cardiologists as examiners.
Summary: Rational Clinical Examination — aortic regurgitation (Choudhry 1999 — 16 studies): cardiologists' precision for diastolic murmurs was moderate on audiotapes (κ 0.51) and good clinically (94% agreement); an early diastolic murmur had a positive likelihood ratio of 8.8–32.0 for mild-or-greater and 4.0–8.3 for moderate-or-greater regurgitation, and its absence a negative likelihood ratio of 0.2–0.3 / 0.1 respectively
Result: Cardiologists' precision for detecting diastolic murmurs was moderate using audiotapes (kappa 0.51) and good in the clinical setting (simple agreement 94%). The most useful finding for ruling in AR was an early diastolic murmur (positive likelihood ratio 8.8–32.0 for mild-or-greater AR and 4.0–8.3 for moderate-or-greater AR); its absence was most useful for ruling out (negative likelihood ratio 0.2–0.3 for mild-or-greater and 0.1 for moderate-or-greater AR); most other signs showed poor sensitivity and specificity, as published.
Watch out: Counted as a synthesis. Target severity changes the likelihood ratio (mild-or-greater vs moderate-or-greater) and prints with it. The authors conclude not enough is known about less-expert clinicians.
Source: Choudhry NK et al. The rational clinical examination. Does this patient have aortic regurgitation?. JAMA. 1999. PMID: 10376577. Registry ID: none in the record. MeSH: Aortic Valve Insufficiency/diagnosis · Diastole · Heart Auscultation · Heart Murmurs/complications,diagnosis,etiology · Humans · Middle Aged · Mitral Valve Stenosis/diagnosis · Physical Examination · Pulse · Renal Insufficiency/complications
Card 4 — Tromsø general-population study (Davidsen 2025 — 2,082 participants aged ≥40 with echocardiography; GPs blinded to echo results): murmurs detected in 23%, significant valve disease present in 19% but only 35.5% of those had an audible murmur; systolic murmurs had sensitivity 100% and specificity 78% for aortic stenosis, sensitivity 43% for aortic regurgitation and 29% for mitral regurgitation, with specificity above 94% for distinct murmurs and above 99% for the rare diastolic murmurs (n = 9)
Study: General-population diagnostic accuracy study (report 4 of 4)
Population: 2,082 participants aged 40 and over (mean age 63) in the seventh Tromsø Study, with heart sounds recorded at four chest locations and classified by general practitioners blinded to echocardiographic results; significant valve disease was at least mild aortic stenosis or at least moderate aortic or mitral regurgitation.
Summary: Tromsø general-population study (Davidsen 2025 — 2,082 participants aged ≥40 with echocardiography; GPs blinded to echo results): murmurs detected in 23%, significant valve disease present in 19% but only 35.5% of those had an audible murmur; systolic murmurs had sensitivity 100% and specificity 78% for aortic stenosis, sensitivity 43% for aortic regurgitation and 29% for mitral regurgitation, with specificity above 94% for distinct murmurs and above 99% for the rare diastolic murmurs (n = 9)
Result: GPs detected murmurs in 487 participants (23%); significant valve disease was identified in 392 (19%), but only 139 of them (35.5%) had an audible murmur. Systolic murmurs detected all cases of AS (sensitivity 100%, specificity 78%); sensitivity was 43% for AR and 29% for MR, while specificity of distinct murmurs exceeded 94% across valve types and diastolic murmurs (n = 9) were over 99% specific. Among participants with murmurs, age 70 or over (odds ratio 2.0, labelled as such), male sex (odds ratio 3.3) and previous myocardial infarction (odds ratio 2.3) were independently associated with valve disease, as published.
Watch out: The examiner spectrum here is the opposite of the RCE cards: GP-classified recorded heart sounds in an unselected population, where most significant valve disease was inaudible. The two spectra may not be merged into a single accuracy claim.
Source: Davidsen AH et al. Heart murmurs in the general population: diagnostic value and prevalence from the Tromsø Study.. Heart (British Cardiac Society). 2025. PMID: 40750340. Registry ID: none in the record. MeSH: Humans · Male · Female · Middle Aged · Heart Murmurs/epidemiology,diagnosis,etiology · Aged · Prevalence · Heart Auscultation/methods · Echocardiography · Norway/epidemiology · Mitral Valve Insufficiency/epidemiology,diagnosis · Adult · Predictive Value of Tests · Heart Valve Diseases/epidemiology,diagnosis · Aged, 80 and over · Aortic Valve Stenosis/epidemiology,diagnosis · Aortic Valve Insufficiency/epidemiology,diagnosis
Card 5 — Synthesis — examiner spectrum is the headline: cardiologist-examiner syntheses give useful likelihood ratios, while the one general-population GP study found most significant valve disease inaudible (only 35.5% with a murmur)
Study: Synthesis
Population: Four reports: an aortic-stenosis meta-analysis and two Rational Clinical Examination syntheses (all counted as syntheses, never as independent confirmations), plus one general-population primary study (Tromsø, n = 2,082). Carotid bruit accuracy is a different sign and question, homed separately, and cross-points in prose only.
Summary: Synthesis — examiner spectrum is the headline: cardiologist-examiner syntheses give useful likelihood ratios, while the one general-population GP study found most significant valve disease inaudible (only 35.5% with a murmur)
Result: For at least moderate aortic stenosis, a diminished second heart sound (positive likelihood ratio 10.87) and delayed carotid upstroke (9.04) help rule in and absent neck radiation (0.11) helps rule out, on low-quality evidence; the 1997 RCE's ranges for the same signs span an order of magnitude (2.8–130). For aortic regurgitation, an early diastolic murmur rules in (8.8–32.0 for mild-or-greater) in cardiologist hands. In general practice conditions, auscultation was highly specific but insensitive for regurgitant lesions (sensitivity 43% AR, 29% MR) and missed most significant valve disease overall.
Watch out: This is a diagnostic-accuracy shelf, not a screening-programme endorsement: high specificity with low sensitivity in the population study means a heard murmur matters and an unheard one reassures far less.
Source: Synthesis of the reports carded above; no additional source.